Radiograph images suddenly become very bright after slightly lower the window level in Weasis #373

Closed
yufoon2002 opened this issue Feb 8, 2023 · 4 comments

Comments

@yufoon2002
Copy link

When I try to open certain radiographs in weasis, while I try to slightly lower the window level by dragging the mouse downwards, the images sudden becomes very bright and the window level and width becomes difficult to manipulate again afterwards. This happens in the latest Weasis 4.0.3 and also the earlier versions of Weasis. I test those radiographs in other dicom viewers in which the manipulaton of window level and window width works properly. I have attached a sample dicom for illustration. Thank you. very much for your help.

https://drive.google.com/file/d/1BTG9zmA_xXBAjbiuoJWEY9jAawFhQ7Px/view?usp=sharing

@nroduit
Copy link
Owner

nroduit commented Feb 9, 2023

Thank you for reporting this problem. Indeed in this case the min/max values of the Level are not correct. It seems to be due to the fact that the VOI LUT has a higher range than the data which is really exceptional.

@yufoon2002
Copy link
Author

yufoon2002 commented Feb 10, 2023

Thank you for reporting this problem. Indeed in this case the min/max values of the Level are not correct. It seems to be due to the fact that the VOI LUT has a higher range than the data which is really exceptional.

Thank you very much for your reply. Manipulation of images in Weasis is great most of the time for most of the images, but it happens that the above mentioned odd situation of bizzare windowing appearance occurs after minor manipulation of the the window level occasionally. I guess this may be due to some odd / infrequent setting by the acquiring radiographic machine or the operators. Anyway it would be great if enhancement in this issue can be made in the next release. Thank you very much again for your help.

@nroduit
Copy link
Owner

nroduit commented Feb 10, 2023

It has been fixed and will be in the next release.

@yufoon2002
Copy link
Author

It has been fixed and will be in the next release.

Thank you very much for your help.

@nroduit nroduit closed this as completed Feb 17, 2023
nroduit added a commit that referenced this issue Feb 18, 2023
@nroduit nroduit added this to the 4.1.0 milestone Apr 26, 2023