EMS-ESP has a command API which can be used to read and write values to EMS device and call specific commands.

There are 3 methods commands can be invoked:

Definitions

  • <device> is the short-name of either
    • an EMS Device such as boiler, thermostat, mixer, heatpump, solar or gateway
    • the EMS-ESP system itself as system
    • the Dallas temperature sensors as dallassensor
  • <command> is the name of either
    • a generic command, or
    • an EMS device entity also referred to as an <entity>. See the table below for the complete list
  • <id> is an optional identifier and has different meanings depending on the context
  • <data> is used to represent the value to read or write. It can be either:
    • a single value. This can be of any type; integer, float, string or boolean
    • as a JSON object containing the following optional key/values:
      • "cmd" is the <command>. The key "cmd" may also be substituted for "entity".
      • "value" is the value and can be either a text string in quotes, an integer, float of boolean. "data" is an alias that can also be used instead for the key.
      • "hc", "wwc" and "id" are all are used to represent a value or in the context of an EMS Device a heating or warm water circuit.

Note: A boolean value can be represented in many forms:

  • as a True value, "TRUE", "yes", true, "true", "on", 1
  • as a False value, "FALSE", "no", false, "false", "off", 0

Console

  • Commands can be executed using the call command
  • You need to be admin to use the call command. First su and enter the password
  • For a list of all available commands you can use show commands
  • The syntax is call <device> <command> <data> <id>

For more information on how to use the Telnet Console see the Console section.

HTTP API

Things to note:

  • The REST API follows the OpenAPI Specification
  • The URL path always starts with http://<hostname>/api/
  • <hostname> is either an IP address or the mDNS name, which default is ems-esp.local
  • Some commands require can be dangerous and require security authentication, unless disabled via an EMS-ESP setting. The authentication is in the form of an Access Token which is generated from the Web UI's Security tab. The 152 character long string must be included in the HTTP header like "Authorization: Bearer {ACCESS_TOKEN}". The tokens have no expiry date
  • With HTTP PUSH/PUT/PATCH commands an HTTP body may be required. This can be in the form of either plain text or as a JSON object <data>
  • HTTPS with self-signed certificates are not yet supported

Reading and Writing EMS Device information

The URL path is http://<hostname>/api/<device>/

endpoint HTTP method action authentication required? body
info GET outputs current EMS device information in verbose no
values GET outputs current EMS device information in short format no
(empty) GET same as values above no
commands GET lists the available commands or entities to call no
entities GET lists the matching Home Assistant entities (HA only) no
{entity} GET outputs details of a specific entity, for reading no
{entity}/{hc} GET same as the read command above but for a specific heating circuit no
{entity} POST updates a entity value, for writing yes <data>
{entity}/{hc} POST same as the write command above but for a specific heating circuit yes <data>

Examples:

URL body action
http://ems-esp.local/api/thermostat/temp 22 sets the selected room temperature of the master thermostat on heating circuit 1
http://ems-esp.local/api/thermostat {"cmd":"mode", "data":"auto"} sets the thermostat mode to auto for heating circuit 1
http://ems-esp.local/api/thermostat {"cmd":"seltemp", "data":23, "hc":3} sets the room temperature to 23 degrees for for heating circuit 3
http://ems-esp.local/api/thermostat/hc2 {"cmd":"seltemp", "data":20.5} sets the room temperature to 20.5 degrees for for heating circuit 2

System Commands

The URL path is http://<hostname>/api/system/<endpoint>

endpoint HTTP method action authentication required? body
info GET outputs current system information no
fetch GET forces at refresh of all device values no
restart GET restarts EMS-ESP yes
commands GET lists the available system commands no
send POST send telegram to the EMS bus yes "XX XX...XX"
publish POST MQTT publish all values, and optional HA-configuration or specific for a device yes [ha] | [device]
watch POST watch incoming telegrams yes <on |off | raw | <type-id(hex)>
syslog_level POST set syslog level yes <level>

Fetching Dallas temperature sensor information

The URL path is http://<hostname>/api/dallassensor/

endpoint HTTP method action authentication required? body
info GET outputs connected Dallas sensors and readings no

Fetching analog sensor information

The URL path is http://<hostname>/api/analogsensor/

endpoint HTTP method action authentication required? body
info GET outputs configured analog sensors and readings no
commands GET lists the available system commands no
setvalue POST set value/offset of counter or output pin, +/- sign corrects value yes {"value":<val>, "id":<gpio>}

EMS Device Entity Names

The tables below list the available commands (or entities) for each specific EMS device. These replace the <entity> in the URL.

Boiler: boiler

[!NOTE] The boiler commands below will vary depending on boiler type/brand and system configuration Some commands will not work because they are overwritten by controller or thermostat. In this case there are thermostat commands for this setting.

command data id comments
comfort <hot |eco | intelligent>
flowtemp <degrees> Limited to heatingtemp, set by thermostat if present
wwsettemp <degrees> Only if thermostat does not manage it
boilhyston <degrees> Start burner below flowtemp (negative value), allowed range depends on boiler type
boilhystoff <degrees> Stop burner above flowtemp (positive value), allowed range depends on boiler type
burnperiod <minutes>
burnminpower <%> Changeable only for modulated burners
burnmaxpower <%> Changeable only for modulated burners
pumpdelay <minutes>
wwactivated <off | on>
wwtapactivated <off | on> Special function working in boiler test-mode
wwonetime <off | on> Overwritten by some thermostats, see thermostat commands
wwcircpump <off | on>
wwcirc <off | on> Overwritten by some thermostats, see thermostat commands
wwcircmode <n> (1=1x3min, .. 6=6x3min, 7=on)
wwflowtempoffset <degrees> Offset to boiler temperature while preparing warm water
wwmaxpower <%> Maximum power for warm water heating
heatingactivated <off | on> Not changeable for some systems. i.g. Set by MC10 rotary control
heatingtemp <degrees> Upper limit for flowtemp, not changeable for some systems or overwritten (MC10)
maintenance <off | <hours> | <dd.mm.yyyy> | reset> set maintenance to date or time or reset message
pumpmodmin <%> Changeable only for modulated pumps
pumpmodmax <%> Changeable only for modulated pumps
reset <error | maintenance> Use reset error only if there is an active error!

Thermostats: thermostat

[!NOTE] The actual thermostat commands below will vary depending on which Thermostat brand and model you have.

command data id comments
datetime <ntp | dd.mm.yyyy-hh:mm:ss-dw-dst> RC35, RC100, RC300, dw:day of week: 0-mo,.. dst:daylight saving 0/1
wwmode <off | on | auto> RC100, RC300, RC30, RC35
wwsettemp <degrees> RC100, RC300
wwsettemplow <degrees> RC100, RC300
wwcircmode <off | on | auto | own> RC30, RC35, RC100, RC300
wwonetime <off | on> RC100, RC300
clockoffset <seconds> RC30
language <n> RC30 (0=de, 1=nl, 2=fr, 3=it)
display <n> RC30 (0=int temp, 1= int set, 2=ext temp, 3=burner, 4=ww, 5=mode, 6=time, 7=date, 8=smoke)
minexttemp <degrees> RC30, RC35, RC100, RC300
calinttemp <degrees> RC30, RC35
building <light | medium | heavy> RC30, RC35, RC100, RC300
temp <degrees> heating circuit actual setpoint depending on mode
mode <auto | night | day | nofrost | heat | eco> heating circuit
manualtemp <degrees> heating circuit RC100, RC300
ecotemp <degrees> heating circuit RC100, RC300, Junkers
heattemp <degrees> heating circuit Junkers
comforttemp <degrees> heating circuit RC100, RC300
summermode <winter | auto | summer> heating circuit RC100, RC300
summertemp <degrees> heating circuit RC30, RC35, RC100, RC300
nighttemp <degrees> heating circuit RC20, RC30, RC35
daytemp <degrees> heating circuit RC20, RC30, RC35
daytemp2 <degrees> heating circuit RC20
daytemp3 <degrees> heating circuit RC20
daytemp4 <degrees> heating circuit RC20
nofrosttemp <degrees> heating circuit RC30, RC35, RC100, RC300, Junkers
remotetemp <degrees> heating circuit RC30, RC35
control <off | RC20 | RC3x> heating circuit RC30, RC35 (roomcontrol for hc)
pause <hours> heating circuit RC30, RC35
party <hours> heating circuit RC30, RC35
holiday <dd.mm.yyyy-dd.mm.yyyy | dd.mm.yyyy+dd.mm.yyyy> heating circuit RC30, RC35, use - for 'away from home', + for 'at home'
designtemp <degrees> heating circuit RC30, RC35, RC100, RC300
offsettemp <degrees> heating circuit RC30, RC35, RC100, RC300
holidaytemp <degrees> heating circuit RC30, RC35
roominfluence <degrees> heating circuit RC30, RC35, RC100, RC300
minflowtemp <degrees> heating circuit RC30, RC35, RC100, RC300
maxflowtemp <degrees> heating circuit RC30, RC35, RC100, RC300
flowtempoffset <degrees> heating circuit RC30, RC35
program <0 - 10 | 1 - 9 | 1 - 2> heating circuit RC30, RC35, RC20, RC100, RC300
controlmode <room | outdoor> heating circuit RC30, RC35, RC100, RC300
reducemode <nofrost | reduce | room | outdoor> heating circuit RC30, RC35
roomtemp <degrees> heating circuit only v2.2: fake HA-thermostat roomtemp, use -1 to clear
switchtime <nn.d.o.hh:mm> heating circuit only v3: set one of the programs switch times, nn=number(00-42), d=day(0-6), o=on(0,1), hh:mm=time, d=7 or o=7 clears

Examples

...via the command line

# GETs do not need authentication
% curl http://ems-esp.local/api/thermostat/temp

# POSTs (with -d) need authentication tokens
% curl http://ems-esp.local/api/thermostat/temp \
  -H 'Content-Type: application/json' \
  -H 'Authorization: Bearer eyJhbGciOiJIUzI1NiIsInR5cCI6IkpXVCJ8.eyJ1c2VybmFtZSI6ImFkbWluIiwiYWRtaW4iOnRydWUsInZlcnNpb24iOiIzLjEuMWIwIn0.qeGT53Aom4rDYeIT1Pr4BSMdeWyf4_zN9ue2c51ZnM0' \
  -d '{ "value" : 22.5 }'

# GET with authentication using query parameter with token
% curl http://ems-esp.local/api/system/publish\?access_token\="eyJhbGciOiJIUzI1NiIsInR5cCI6IkpXVCJ8.eyJ1c2VybmFtZSI6ImFkbWluIiwiYWRtaW4iOnRydWUsInZlcnNpb24iOiIzLjEuMWIwIn0.qeGT53Aom4rDYeIT1Pr4BSMdeWyf4_zN9ue2c51ZnM0"

# GET to restart EMS-ESP
curl http://ems-esp.local/api/system/restart -H 'Authorization: Bearer eyJhbGciOiJIUzI1NiIsInR5cCI6IkpXVCJ8.eyJ1c2VybmFtZSI6ImFkbWluIiwiYWRtaW4iOnRydWUsInZlcnNpb24iOiIzLjEuMWIwIn0.qeGT53Aom4rDYeIT1Pr4BSMdeWyf4_zN9ue2c51ZnM0'

...using a Python script

import requests
import json

url = "http://ems-esp.local/api/thermostat/temp"
token = "eyJhbGciOiJIUzI1NiIsInR5cCI6IkpXVCJ8.eyJ1c2VybmFtZSI6ImFkbWluIiwiYWRtaW4iOnRydWUsInZlcnNpb24iOiIzLjEuMWIwIn0.qeGT53Aom4rDYeIT1Pr4BSMdeWyf4_zN9ue2c51ZnM0"
body = json.dumps({ "value": 22.5 })
headers = { 'Content-Type': 'application/json', 'Authorization': 'Bearer ' + token }

response = requests.post(url, headers=headers, data=body, verify=False)

print(response.json())

MQTT

MQTT uses the same format as the API.

The topic matches the URL path except the <hostname> is replaced with the MQTT Base name as defined in the Settings (default is ems-esp).

The payload is the same as the <data> as described above and used in the API.

Examples:

topic payload action
ems-esp/system/send "XX XX...XX" send raw ems-command
ems-esp/thermostat/seltemp fetches the seltemp entity values and publishes it in the topic ems-esp/response
ems-esp/thermostat/seltemp 23 change the selected setpoint temperature to 23 degreees on the master thermostat on hc1
ems-esp/thermostat/mode "auto" sets the thermostat mode to auto for hc1
ems-esp/thermostat {\"cmd\":\"mode\",\"value\":\"heat\",\"id\":1} sets the thermostat mode to heat for hc1