Battery Capacity is "0.00kWh" #236
Comments
Almost identical for me with a SH10RT v112. Fully patched. What is the register that the capacity is read from? |
Reference to #184 (comment) I found and tested that the capacity can be found in input register 13038 - the following works after a restart of home assistant
I've never made a PR before but would love to contribute if possible :) |
Unfortunately 13038 was not the adress for my battery_capacity on my inverter. Also my battery_capacity info in the modbus_sungrow.yaml has input_type: "holding", not "input" |
@mathiasolofsson, @liquidblack you can set the capacity in iSolarCloud. There are two settings and under plant configuration is not enough. you have to set it in advanced settings too. For this you nid an installer account on your plant. |
@liquidblack works perfect with SH10RT-V11.2, thx! |
Thanks @mathiasolofsson - it was a bit of dance to get the account set up - for anyone else reading this I needed to added a separate account, create the account, remove the share, re-add the share and then it showed up. I'll do some testing to see if the information shows up on the battery. My open question then becomes - which value should be used if the system "knows" that it's a 9.6kWh battery but I have to set it in another place (to whatever I like) - shouldn't the inbuilt value be the one that's used? |
@liquidblack, sry don't know. The deteced value is under "plant configuration" which might not be available over modbus? or do you own a SH10RT-V112 and get this value by reading input register 13038? |
Hello, I had the same issue, Battery capacity showed 0 in Dashboard. Setting the right Value in iSolarcloud with installer account like @mastameista suggested worked.
|
This issue is stale because it has been open for 30 days with no activity. |
@RafAustralia has some alternative registers to try for battery capacity at #354 |
Before you create an issue, make sure to update to the current version of modbus_sungrow.yaml
Describe the bug:
Value for battery capacity is not existing in HA(battery_capacity).
In my Sungrow Plant Configuration on the iSolarapp the battery capacity is shown as 9.6kWh.
I have a SH6.0RT-V112 inverter with a 9.6kWh sungrow battery.
Your Sungrow inverter:
Model: [e.g. SH-10.RT v112]
The inverter is connected via (mark one)
Are you using a Modbus Proxy (mark one)
Home Assistant version:
modbus_sungrow.yaml:
** Inverter Firmware Status:**