# Version 3.0
#######################################
########## Hardware settings ##########
#######################################
NR_OF_BATTERIES = 2 # Nr. of physical batteries to be aggregated
NR_OF_CELLS_PER_BATTERY = 22
NR_OF_MPPTS = 1 # Nr. of MPPTs
DC_LOADS = False # If DC loads with Smart Shunt present, can be used for total current measurement
INVERT_SMARTSHUNT = False # False: Current subtracted, True: Current added
#######################################
############ DBus settings ############
#######################################
BATTERY_SERVICE_NAME = 'com.victronenergy.battery' # Key world to identify services of physical Serial Batteries (and SmartShunt if available)
BATTERY_PRODUCT_NAME_PATH = '/ProductName' # Path of Battery Product Name
BATTERY_PRODUCT_NAME = 'SerialBattery' # Key world to identify the batteries (to exclude SmartShunt)
BATTERY_INSTANCE_NAME_PATH = '/CustomName' # if CustomName doesn't exist, set '/ProductName'
MULTI_KEY_WORD = 'com.victronenergy.vebus' # Key world to identify service of Multis/Quattros (or cluster of them)
MPPT_KEY_WORD = 'com.victronenergy.solarcharger' # Key world to identify services of solar chargers
SMARTSHUNT_NAME_KEY_WORD = 'SmartShunt' # Key world to identify services of SmartShunt
SEARCH_TRIALS = 10 # Trials to identify of all batteries before exit and restart
READ_TRIALS = 10 # Trials to get consistent data of all batteries before exit and restart
#######################################
############ DBus settings ############
#######################################
CURRENT_FROM_VICTRON = True # If True, the current measurement by Multis/Quattros and MPPTs is taken instead of BMS
OWN_SOC = True # If True, the self calculated charge indicators are taken instead of BMS
CHARGE_SAVE_PRECISION = 0.0025 # Trade-off between save precision and file access frequency
#######################################
##### Charge/Discharge parameters #####
#######################################
# Please note: Victron ESS disables CCL if DC-coupled PV feed-in is active
OWN_CHARGE_PARAMETERS = True # Calculate own charge/discharge control parameters (True) from following settings
# or use them from battery driver (False)
USE_MAX_CVL = False # Use the highest requested charge Voltage from all Packs. If False lowest Voltage will be used (Balance all Packs, Balance only fastest Pack)
CHARGE_VOLTAGE = 2.3 # Constant voltage charge = this value * nr. of cells
BALANCING_VOLTAGE = 2.45 # This voltage per cell will be set periodically and kept until balancing below CELL_DIFF_MAX and next charge cycle
BALANCING_REPETITION = 10 # in days
MAX_CELL_VOLTAGE = 2.5 # If reached by 1-st cell, the CVL is dynamically limited. DC-coupled PV feed-in will be disabled to enable the CCL.
DISCHARGE_VOLTAGE = 2.0 # If reached, discharge current set to zero
MIN_CELL_VOLTAGE = 1.9 # If reached, discharge current set to zero
CELL_DIFF_MAX = 0.025 # If lower: re-enable DC-coupled PV feed in (if was enabled before); go back from BALANCING_VOLTAGE to CHARGE_VOLTAGE
MAX_CHARGE_CURRENT = 300 # Max. charge current at normal conditions
MAX_DISCHARGE_CURRENT = 200 # Max. discharge current at normal conditions
# settings limiting charge and discharge current if at least one cell gets full or empty
# the lists may have any length, but the same length for voltage and current
# linear interpolation is used for values between
CELL_FULL_LIMITING_VOLTAGE = [CHARGE_VOLTAGE, BALANCING_VOLTAGE, MAX_CELL_VOLTAGE] # [min, .... ,max]
CELL_FULL_LIMITED_CURRENT = [1, 0.05, 0]
CELL_EMPTY_LIMITING_VOLTAGE = [DISCHARGE_VOLTAGE - 0.1, DISCHARGE_VOLTAGE, MIN_CELL_VOLTAGE] # [min, .... ,max]
CELL_EMPTY_LIMITED_CURRENT = [0, 0.05, 1]
#######################################
####### Logging and reporting #########
#######################################
SEND_CELL_VOLTAGES = 0 # 0: Disable Cell Info in dbus, 1: Format: /Cell/BatteryName_Cell<ID>
LOGGING = 2 # 0: no logging, 1: print to console, 2: print to file
LOG_PERIOD = 600 # in seconds; if 0, periodic logging is disabled