Just a heads-up, if you notice error messages like:
$ ./ml prod bootstrap
ERROR: ADMIN-INVALIDCONFIG: (err:FOER0000) Invalid configuration: Field or Word Query cannot have stemmed-searches set to 'off'
See MarkLogic Server error log for more details.
ERROR: ... Bootstrap FAILED
and
$ ./ml prod bootstrap
ERROR: ADMIN-INVALIDFIELDCONFIG: (err:FOER0000) Field must have equal or greater stemmed searches setting than its database "advanced" setting
See MarkLogic Server error log for more details.
ERROR: ... Bootstrap FAILED
then that is because your database has a field with a stemming set to lower than the database setting, maybe off. You can flip the setting manually over from Admin interface or upgrade to 7.0-3 to get round this issue..
The text was updated successfully, but these errors were encountered:
Just a heads-up, if you notice error messages like:
and
then that is because your database has a field with a stemming set to lower than the database setting, maybe off. You can flip the setting manually over from Admin interface or upgrade to 7.0-3 to get round this issue..