You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Hello,
i wan't to read 3 way valve position
But values are resulting error
bai ValveMode = (ERR: invalid position for 3108b509030d2a04 / 00) [ZZ=08, lastup=2025-01-15 17:03:54, active read]
Actual behavior
bai ValveMode = (ERR: invalid position for 3108b509030d2a04 / 00) [ZZ=08, lastup=2025-01-15 17:03:54, active read]
Expected behavior
it thould return 3 Way Valve position
ebusd version
24.1
ebusd arguments
N/A
Operating system
other
CPU architecture
x64
Dockerized
latest
Hardware interface
Adapter Shield v5 via WiFi
Related integration
No response
Logs
from findall script
r5,bai,ValveStarts,3WV Schaltspiele: Anzahl der 3WV Umschaltungen,,08,b509,0d1a00,value,s,UIN,,,Anzahl Starts
from runall script
bai ValveMode = ERR: invalid position in decode
version: ebusd 24.1.24.1
update check: OK, device firmware v5-c6 1[4c15] up to date
device: 192.168.19.174:9999, TCP, enhanced, firmware 1.1[4c15].1[4c15]
signal: acquired
symbol rate: 23
max symbol rate: 177
min arbitration micros: 1
max arbitration micros: 30
min symbol latency: 5
max symbol latency: 44
scan: finished
reconnects: 0
masters: 4
messages: 699
conditional: 3
poll: 247
update: 16
address 03: master #11
address 08: slave #11, scanned "MF=Vaillant;ID=BAI00;SW=0104;HW=7803", loaded "vaillant/bai.308523.inc", "vaillant/08.bai.csv"
address 10: master #2
address 15: slave #2, scanned "MF=Vaillant;ID=70000;SW=0614;HW=6903", loaded "vaillant/15.700.csv"
address 31: master #8, ebusd
address 36: slave #8, ebusd
address f1: master #10
address f6: slave #10, scanned "MF=Vaillant;ID=NETX2;SW=4035;HW=5703"
The text was updated successfully, but these errors were encountered:
the target answers with zero length, so it basically does not support the message I guess.
anyway, not an ebusd issue, so closing. use ebusd-configuration instead for message defs
Description
Hello,
i wan't to read 3 way valve position
But values are resulting error
bai ValveMode = (ERR: invalid position for 3108b509030d2a04 / 00) [ZZ=08, lastup=2025-01-15 17:03:54, active read]
Actual behavior
bai ValveMode = (ERR: invalid position for 3108b509030d2a04 / 00) [ZZ=08, lastup=2025-01-15 17:03:54, active read]
Expected behavior
it thould return 3 Way Valve position
ebusd version
24.1
ebusd arguments
N/A
Operating system
other
CPU architecture
x64
Dockerized
latest
Hardware interface
Adapter Shield v5 via WiFi
Related integration
No response
Logs
from findall script
r5,bai,ValveStarts,3WV Schaltspiele: Anzahl der 3WV Umschaltungen,,08,b509,0d1a00,value,s,UIN,,,Anzahl Starts
from runall script
bai ValveMode = ERR: invalid position in decode
version: ebusd 24.1.24.1
update check: OK, device firmware v5-c6 1[4c15] up to date
device: 192.168.19.174:9999, TCP, enhanced, firmware 1.1[4c15].1[4c15]
signal: acquired
symbol rate: 23
max symbol rate: 177
min arbitration micros: 1
max arbitration micros: 30
min symbol latency: 5
max symbol latency: 44
scan: finished
reconnects: 0
masters: 4
messages: 699
conditional: 3
poll: 247
update: 16
address 03: master #11
address 08: slave #11, scanned "MF=Vaillant;ID=BAI00;SW=0104;HW=7803", loaded "vaillant/bai.308523.inc", "vaillant/08.bai.csv"
address 10: master #2
address 15: slave #2, scanned "MF=Vaillant;ID=70000;SW=0614;HW=6903", loaded "vaillant/15.700.csv"
address 31: master #8, ebusd
address 36: slave #8, ebusd
address f1: master #10
address f6: slave #10, scanned "MF=Vaillant;ID=NETX2;SW=4035;HW=5703"