Skip to content

Commit

Permalink
PowerCap: Fix mode for energy counter
Browse files Browse the repository at this point in the history
As per the documentation of powercap sysfs, energy_uj field is read only,
if it can't be reset. Currently it always allows write but will fail,
if there is no reset callback.
Changing mode field, to read only if there is no reset callback.

Signed-off-by: Srinivas Pandruvada <[email protected]>
Reported-by: Dirk Brandewie <[email protected]>
Signed-off-by: Rafael J. Wysocki <[email protected]>
  • Loading branch information
spandruvada authored and rafaeljw committed Dec 5, 2013
1 parent 08ff4cb commit 95677a9
Showing 1 changed file with 6 additions and 1 deletion.
7 changes: 6 additions & 1 deletion drivers/powercap/powercap_sys.c
Original file line number Diff line number Diff line change
Expand Up @@ -377,9 +377,14 @@ static void create_power_zone_common_attributes(
if (power_zone->ops->get_max_energy_range_uj)
power_zone->zone_dev_attrs[count++] =
&dev_attr_max_energy_range_uj.attr;
if (power_zone->ops->get_energy_uj)
if (power_zone->ops->get_energy_uj) {
if (power_zone->ops->reset_energy_uj)
dev_attr_energy_uj.attr.mode = S_IWUSR | S_IRUGO;
else
dev_attr_energy_uj.attr.mode = S_IRUGO;
power_zone->zone_dev_attrs[count++] =
&dev_attr_energy_uj.attr;
}
if (power_zone->ops->get_power_uw)
power_zone->zone_dev_attrs[count++] =
&dev_attr_power_uw.attr;
Expand Down