From 93439789d4f5fcf962a6a7b95a98843eac9d9d5e Mon Sep 17 00:00:00 2001 From: Marc MERLIN Date: Sun, 23 Oct 2016 21:36:07 -0700 Subject: [PATCH] minor omnistat fixes. set_filter_reminder is in hours of runtime, reset to 30 days. added info on newer omnistat stats. --- code/support/hai-omnistat/omnistat.pl | 4 ++-- lib/Omnistat.pm | 2 ++ 2 files changed, 4 insertions(+), 2 deletions(-) diff --git a/code/support/hai-omnistat/omnistat.pl b/code/support/hai-omnistat/omnistat.pl index c5cbcd006..dff3361fb 100644 --- a/code/support/hai-omnistat/omnistat.pl +++ b/code/support/hai-omnistat/omnistat.pl @@ -234,8 +234,8 @@ Omnistat::omnistat_log( "$omniname[$omnistat] Omnistat: replace the filter", 0 ); - # reset the timer to 6 months - $omnistat[$omnistat]->set_filter_reminder(180); + # reset the timer to 30 days of runtime (59 max) + $omnistat[$omnistat]->set_filter_reminder(30); } else { Omnistat::omnistat_log( diff --git a/lib/Omnistat.pm b/lib/Omnistat.pm index 2de1eb3fc..39fb5ea0f 100644 --- a/lib/Omnistat.pm +++ b/lib/Omnistat.pm @@ -380,6 +380,8 @@ RC-112 34 RC-120 48 RC-121 49 RC-122 50 +RC-1000: 110 +RC-2000: 120 Outside Temperature: writing to the outside temperature register will cause the thermostat to display the outside temperature every 4 seconds. The thermostat will stop displaying the outside temperature if this