-- FileName : check_dg_redo_apply.sql
--
-- Description : This sql script used to check redo data apply on
--
-- Oracle Data Guard physical standby database.
--
-- Author : Quanwen Zhao
--
-- Create Date : 2017/07/11
--
-- -----------------------------------------------------------------
SET heading ON
SET trimspool ON
SET newpage NONE
SET echo OFF
SET feedback OFF
SET verify OFF
SET define OFF
SET termout OFF
SET timing OFF
SET colsep "|"
SET linesize 400
SET pagesize 200
----------------------------------------------------------------
-- Query value of current date oracle physical standby database
----------------------------------------------------------------
COL current_scn FOR 9999999999999999
SELECT scn_to_timestamp(current_scn) FROM v$database;
PROMPT
---------------------------------------------------------------------------------
-- Query max value of sequence# and applied's status is yes by 'v$archived_log'
---------------------------------------------------------------------------------
SELECT MAX(sequence#) FROM v$archived_log WHERE applied='YES';
PROMPT
--------------------------------------------------------------------------------
-- Query max value of sequence# and applied's status is no by 'v$archived_log'
--------------------------------------------------------------------------------
SELECT MAX(sequence#) FROM v$archived_log WHERE applied='NO';
PROMPT
----------------------------------------------------------------------------
-- Query value of 'process','pid','status' and etc. by 'v$managed_standby'
----------------------------------------------------------------------------
SELECT process,pid,status,sequence#,block#,blocks,delay_mins FROM v$managed_standby;
PROMPT
----------------------------------------------------------------------
-- Query value of 'sequence#','status','archived' by 'v$standby_log'
----------------------------------------------------------------------
SELECT sequence#,status,archived FROM v$standby_log;
PROMPT
-------------------------------------------
-- Query all value by 'v$dataguard_stats'
-------------------------------------------
COL name FOR a24
COL value FOR a12
COL unit FOR a28
COL time_computed FOR a20
COL datum_time FOR a20
SELECT * FROM v$dataguard_stats;