IO.SYS
is from the Windows MillenniumNETTOOLS
, included on the Windows Me CD. (Contained withinTOOLS\NETTOOLS\FAC\CBS.DTA
; a CAB file.)This file contains the XMS driver,
IFSHLP
driver and Windows boot logo, and does not require any additional lines added toCONFIG.SYS
orAUTOEXEC.BAT
to start Windows. It also contains the Windows Millennium Boot Menu accessible by holding CTRL on startup, allowing the user to choose Normal, Safe Mode, Command Line Only, etc.Decompressed with Rudolph Loew's IO8DCOMP, and the "Now preparing to start your new computer..." string displayed on startup has been replaced with "Starting Windows Millennium Edition...".
-
COMMAND.COM
is not bundled, but locally patchedAn unmodified version of
COMMAND.COM
could be taken from the Windows MillenniumNETTOOLS
on the Windows Me CD instead, requiring no patching. This version ofCOMMAND.COM
is contained withinTOOLS\NETTOOLS\FAC\LTOOLS.DTA
; a CAB file.The reason for not bundling it is to apply the patches to the locally installed
COMMAND.COM
instead, retainingCOMMAND.COM
in the localized language.The patches are applied in INSTALL.BAT
-
REGENV32.EXE
is not bundled either, for the same reason as mentioned forCOMMAND.COM
REGENV32
reads Windows environment variables from the registry and overwrites the contents ofAUTOEXEC.BAT
andCONFIG.SYS
on each restart. These patches instead haveREGENV32
write toAUTOEXEC.WIN
andCONFIG.WIN
, leaving the contents ofAUTOEXEC.BAT
andCONFIG.SYS
intact so the user can make alterations or add additional lines as needed.The patches are applied in INSTALL.BAT
-
SYS.COM
is from Windows Millennium Developer Release 1 (Build 2332).This file is unmodified. Its behaviour is otherwise the same as
SYS.COM
in Windows 98 Second Edition, however the version information in the DR1 build is already updated for MS-DOS 8.0, so no patches are required to overcome the "Incorrect DOS version" error.SYS.COM
allows the user to copy MS-DOS system files to a specified drive letter and make it bootable. TheSYS
command included in the retail release of Windows Millennium disables this feature and instructs the user to create a Startup Disk in Control Panel > Add/Remove Programs instead. ReplacingSYS.COM
restores its original functionality. -
WIN.COM
is from Windows 98 Second Edition.At present, this file is unmodified. The Windows Me version may still be usable however, so this is not finalised.
In Windows Me, Microsoft removed the undocumented switches needed to exit MS-DOS mode and back to Windows - specifically the /WX switch. When booting into MS-DOS mode with a custom
AUTOEXEC
andCONFIG
, the existingAUTOEXEC.BAT
andCONFIG.SYS
are moved out of the way intoAUTOEXEC.WOS
andCONFIG.WOS
respectively. The /WX switch moves the temporary.WOS
files back into.BAT
and.SYS
, and restarts into Windows. Without this switch, the computer just continues to reboot into MS-DOS mode with each restart, or the computer just hangs when "exit" or "win" is typed.It may be possible to re-add these undocumented switches back into Windows Me's
WIN.COM
. -
WINOA386.MOD
is from either Windows 98 Second Edition or Windows Millennium Developer Release 1 (Build 2332).The Millennium DR1 file is an unmodified, direct replacement. It seems to work fine, however it's still being tested. (It appears to be extremely similar to the 98 version though, even when comparing their contents in hex side-by-side.)
The Windows 98 file is patched, and requires the replacement of two bytes - Offset 0x2CE2 replace 0A with 5A, and Offset 0x2D4C replace 00 with 5A - to clear a mismatched Windows version error. However it also seems to work fine.
"WINOA386.MOD
provides a console for MS-DOS within the 32 bit Windows environment and gives access to the command line disk operating system commands which MS-DOS offers. The
WINOA386` file included in the retail release of Windows Millennium returns warnings that Real Mode MS-DOS is no longer supported, and prevents restarting into MS-DOS mode when called from the Shut Down window. Using the DR1 or 98 version of this file removes this limitation. -
PIFMGR.DLL
is from either Windows 98 Second Edition or Windows Millennium Developer Release 1 (Build 2332).Both the Millennium DR1 and Windows 98 files are unmodified, direct drop-in replacements. Both contain different code internally, but appear to otherwise behave the same.
This file handles the use of .PIF files, MS-DOS application properties (from Right Click > Properties), the creation of temporary
AUTOEXEC.BAT
andCONFIG.SYS
files when restarting into MS-DOS mode, and specifies the commands that should be issued toWIN.COM
when leaving MS-DOS mode.The
PIFMGR.DLL
included in the retail release of Windows Millennium returns an error when restarting into MS-DOS mode that theAUTOEXEC.APP
andCONFIG.APP
temporary files were unable to be created in the C:\ directory due to permissions (existing files marked read-only) or lack of free space. Using the DR1 or 98 version of this file resolves this error.
There is one more optional file:
-
IO8EMMOK.SYS
by Dr. Pu-Feng DuThe
IO.SYS
built-in XMS driver replacesHIMEM.SYS
in MS-DOS 8.0. I'm sketchy on the details, but essentially unlike earlier versions of DOS, to maximise free conventional memory MS-DOS 8.0 and the XMS driver itself are always loaded above 1MB. This High Memory Area is addressable with the A20 line enabled (Gate-A20 ON). However most applications expect the XMS driver to be somewhere within the first 1MB, and turn Gate A20 OFF before calling into the XMS driver. However because MS-DOS 8.0 and the XMS driver are above 1MB, turning Gate A20 OFF makes the driver (and all of DOS, in fact) inaccessible in memory, and so the system hangs.Worst of all, the XMS driver itself is responsible for turning Gate A20 on and off as needed, so if it isn't accessible, then it can't switch the gate on as needed when DOS requires it either.
The most notable example of this is
EMM386.EXE
, the EMS driver included with MS-DOS that some applications depend on. Attempting to loadEMM386
inCONFIG.SYS
immediately halts the system and prevents Windows or MS-DOS from booting.IO8EMMOK
places a small wrapper in the addressable area under 1MB. When a call to the XMS driver is made, it enables Gate A20, forwards the call, and disables Gate A20 again. This allows the XMS driver to remain accessible and in control of the gate, allowing DOS to continue running, and EMM386 to function as normal.This allows applications and games that require EMS memory to run within the Real Mode DOS environment, and not just within the Windows protected mode environment. (In theory, this even allows Windows 3.11 to be run in 386 Enhanced Mode, in tandem with Windows Millennium on MS-DOS 8.)
`HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\Policies\WinOldApp\NoRealMode` is deleted. This allows the "Restart in MS-DOS mode" option to appear in the Shut Down dialog.
The `HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\MS-DOSOptions\HIMEM` key is deleted. Because `IO.SYS` calls on its own integrated XMS driver, loading `HIMEM` in `CONFIG.SYS` is no longer required. Removing this key prevents the `DEVICE=C:\WINDOWS\Himem.Sys` line from being added by default when right clicking an MS-DOS program, and selecting Properties > Program > Advanced > MS-DOS Mode > Specify a new MS-DOS configuration.
`HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\MS-DOSOptions\IO8EMMOK\` has been added to call `WINDOWS\IO8EMMOK.SYS` before `EMM386.EXE` by default when creating a custom `AUTOEXEC` and `CONFIG` in the MS-DOS application properties window.
An uninstall functionality is implemented, so all of the changed files and registry modifications will be reverted when uninstalling `MS-DOS Mode for Windows Millennium Edition" from the Software control panel.