CS800i, Logatherm WLW | boiler | 8 | reset | reset | cmd [-|maintenance|error|history|message] | | True | sensor.boiler_reset | sensor.boiler_reset | 5 | 0 | 1 | 0 | 1 |
CS800i, Logatherm WLW | boiler | 8 | heatingoff | force heating off | boolean | | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | 5 | 0 | 1 | 1 | 1 |
CS800i, Logatherm WLW | boiler | 8 | heatingactive | heating active | boolean | | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | 5 | 0 | 1 | 2 | 1 |
CS800i, Logatherm WLW | boiler | 8 | tapwateractive | tapwater active | boolean | | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | 5 | 0 | 1 | 3 | 1 |
CS800i, Logatherm WLW | boiler | 8 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp | 5 | 0 | 1 | 4 | 1 |
CS800i, Logatherm WLW | boiler | 8 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod | 5 | 0 | 1 | 5 | 1 |
CS800i, Logatherm WLW | boiler | 8 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp | 5 | 0 | 1/10 | 6 | 1 |
CS800i, Logatherm WLW | boiler | 8 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp | 5 | 0 | 1/10 | 7 | 1 |
CS800i, Logatherm WLW | boiler | 8 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp | 5 | 0 | 1/10 | 8 | 1 |
CS800i, Logatherm WLW | boiler | 8 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp | 5 | 0 | 1/10 | 9 | 1 |
CS800i, Logatherm WLW | boiler | 8 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress | 5 | 0 | 1/10 | 10 | 1 |
CS800i, Logatherm WLW | boiler | 8 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp | 5 | 0 | 1/10 | 11 | 1 |
CS800i, Logatherm WLW | boiler | 8 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp | 5 | 0 | 1/10 | 12 | 1 |
CS800i, Logatherm WLW | boiler | 8 | heatingactivated | heating activated | boolean | | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | 5 | 0 | 1 | 13 | 1 |
CS800i, Logatherm WLW | boiler | 8 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp | 5 | 0 | 1 | 14 | 1 |
CS800i, Logatherm WLW | boiler | 8 | heatingpump | heating pump | boolean | | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | 5 | 0 | 1 | 15 | 1 |
CS800i, Logatherm WLW | boiler | 8 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax | 5 | 0 | 1 | 16 | 1 |
CS800i, Logatherm WLW | boiler | 8 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin | 5 | 0 | 1 | 17 | 1 |
CS800i, Logatherm WLW | boiler | 8 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | 5 | 0 | 1 | 18 | 1 |
CS800i, Logatherm WLW | boiler | 8 | pumpcharacter | boiler pump characteristic | enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] | | True | select.boiler_boiler_pump_characteristic | select.boiler_pumpcharacter | 5 | 0 | 1 | 19 | 1 |
CS800i, Logatherm WLW | boiler | 8 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay | 5 | 0 | 1 | 20 | 1 |
CS800i, Logatherm WLW | boiler | 8 | pumpontemp | pump logic temperature | uint8 (>=0<=60) | C | True | number.boiler_pump_logic_temperature | number.boiler_pumpontemp | 5 | 0 | 1 | 21 | 1 |
CS800i, Logatherm WLW | boiler | 8 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow | 5 | 0 | 1 | 22 | 1 |
CS800i, Logatherm WLW | boiler | 8 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow | 5 | 0 | 1 | 23 | 1 |
CS800i, Logatherm WLW | boiler | 8 | burnstarts | burner starts | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | 5 | 0 | 1 | 24 | 2 |
CS800i, Logatherm WLW | boiler | 8 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin | 5 | 0 | 1 | 26 | 2 |
CS800i, Logatherm WLW | boiler | 8 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin | 5 | 0 | 1 | 28 | 2 |
CS800i, Logatherm WLW | boiler | 8 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin | 5 | 0 | 1 | 30 | 2 |
CS800i, Logatherm WLW | boiler | 8 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | 5 | 0 | 1 | 32 | 2 |
CS800i, Logatherm WLW | boiler | 8 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime | 5 | 0 | 1 | 34 | 2 |
CS800i, Logatherm WLW | boiler | 8 | lastcode | last error code | string | | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | 5 | 0 | 1 | 36 | 28 |
CS800i, Logatherm WLW | boiler | 8 | servicecode | service code | string | | False | sensor.boiler_service_code | sensor.boiler_servicecode | 5 | 0 | 1 | 64 | 2 |
CS800i, Logatherm WLW | boiler | 8 | servicecodenumber | service code number | uint16 (>=0<=31999) | | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | 5 | 0 | 1 | 66 | 1 |
CS800i, Logatherm WLW | boiler | 8 | maintenancemessage | maintenance message | string | | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | 5 | 0 | 1 | 67 | 2 |
CS800i, Logatherm WLW | boiler | 8 | maintenance | maintenance scheduled | enum [off|time|date|manual] | | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | 5 | 0 | 1 | 69 | 1 |
CS800i, Logatherm WLW | boiler | 8 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime | 5 | 0 | 1 | 70 | 1 |
CS800i, Logatherm WLW | boiler | 8 | maintenancedate | next maintenance date | string | | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | 5 | 0 | 1 | 71 | 6 |
CS800i, Logatherm WLW | boiler | 8 | emergencyops | emergency operation | boolean | | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | 5 | 0 | 1 | 77 | 1 |
CS800i, Logatherm WLW | boiler | 8 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp | 5 | 0 | 1 | 78 | 1 |
CS800i, Logatherm WLW | boiler | 8 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal | 5 | 0 | 1/100 | 79 | 2 |
CS800i, Logatherm WLW | boiler | 8 | nrg | energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_dhw_energy | sensor.boiler_dhw_nrg | 5 | 9 | 1/100 | 0 | 2 |
CS800i, Logatherm WLW | boiler | 8 | nrgheat | energy heating | uint24 (>=0<=167772) | kWh | False | sensor.boiler_energy_heating | sensor.boiler_nrgheat | 5 | 0 | 1/100 | 81 | 2 |
CS800i, Logatherm WLW | boiler | 8 | nrgcool | energy cooling | uint24 (>=0<=167772) | kWh | False | sensor.boiler_energy_cooling | sensor.boiler_nrgcool | 5 | 0 | 1/100 | 83 | 2 |
CS800i, Logatherm WLW | boiler | 8 | metertotal | meter total | uint24 (>=0<=167772) | kWh | False | sensor.boiler_meter_total | sensor.boiler_metertotal | 5 | 0 | 1/100 | 85 | 2 |
CS800i, Logatherm WLW | boiler | 8 | metercomp | meter compressor | uint24 (>=0<=167772) | kWh | False | sensor.boiler_meter_compressor | sensor.boiler_metercomp | 5 | 0 | 1/100 | 87 | 2 |
CS800i, Logatherm WLW | boiler | 8 | metereheat | meter e-heater | uint24 (>=0<=167772) | kWh | False | sensor.boiler_meter_e-heater | sensor.boiler_metereheat | 5 | 0 | 1/100 | 89 | 2 |
CS800i, Logatherm WLW | boiler | 8 | meterheat | meter heating | uint24 (>=0<=167772) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat | 5 | 0 | 1/100 | 91 | 2 |
CS800i, Logatherm WLW | boiler | 8 | metercool | meter cooling | uint24 (>=0<=167772) | kWh | False | sensor.boiler_meter_cooling | sensor.boiler_metercool | 5 | 0 | 1/100 | 93 | 2 |
CS800i, Logatherm WLW | boiler | 8 | meter | meter | uint24 (>=0<=167772) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meter | 5 | 9 | 1/100 | 2 | 2 |
CS800i, Logatherm WLW | boiler | 8 | uptimetotal | heatpump total uptime | time (>=0<=279620) | minutes | False | sensor.boiler_heatpump_total_uptime | sensor.boiler_uptimetotal | 5 | 0 | 1/60 | 95 | 2 |
CS800i, Logatherm WLW | boiler | 8 | uptimecontrol | total operating time heat | time (>=0<=279620) | minutes | False | sensor.boiler_total_operating_time_heat | sensor.boiler_uptimecontrol | 5 | 0 | 1/60 | 97 | 2 |
CS800i, Logatherm WLW | boiler | 8 | uptimecompheating | operating time compressor heating | time (>=0<=279620) | minutes | False | sensor.boiler_operating_time_compressor_heating | sensor.boiler_uptimecompheating | 5 | 0 | 1/60 | 99 | 2 |
CS800i, Logatherm WLW | boiler | 8 | uptimecompcooling | operating time compressor cooling | time (>=0<=279620) | minutes | False | sensor.boiler_operating_time_compressor_cooling | sensor.boiler_uptimecompcooling | 5 | 0 | 1/60 | 101 | 2 |
CS800i, Logatherm WLW | boiler | 8 | uptimecomp | operating time compressor | time (>=0<=279620) | minutes | False | sensor.boiler_dhw_operating_time_compressor | sensor.boiler_dhw_uptimecomp | 5 | 9 | 1/60 | 4 | 2 |
CS800i, Logatherm WLW | boiler | 8 | uptimecomppool | operating time compressor pool | time (>=0<=279620) | minutes | False | sensor.boiler_operating_time_compressor_pool | sensor.boiler_uptimecomppool | 5 | 0 | 1/60 | 103 | 2 |
CS800i, Logatherm WLW | boiler | 8 | totalcompstarts | total compressor control starts | uint24 (>=0<=16777213) | | False | sensor.boiler_total_compressor_control_starts | sensor.boiler_totalcompstarts | 5 | 0 | 1 | 105 | 2 |
CS800i, Logatherm WLW | boiler | 8 | heatingstarts | heating control starts | uint24 (>=0<=16777213) | | False | sensor.boiler_heating_control_starts | sensor.boiler_heatingstarts | 5 | 0 | 1 | 107 | 2 |
CS800i, Logatherm WLW | boiler | 8 | coolingstarts | cooling control starts | uint24 (>=0<=16777213) | | False | sensor.boiler_cooling_control_starts | sensor.boiler_coolingstarts | 5 | 0 | 1 | 109 | 2 |
CS800i, Logatherm WLW | boiler | 8 | starts2 | control starts2 | uint24 (>=0<=16777213) | | False | sensor.boiler_dhw_control_starts2 | sensor.boiler_dhw_starts2 | 5 | 9 | 1 | 6 | 2 |
CS800i, Logatherm WLW | boiler | 8 | poolstarts | pool control starts | uint24 (>=0<=16777213) | | False | sensor.boiler_pool_control_starts | sensor.boiler_poolstarts | 5 | 0 | 1 | 111 | 2 |
CS800i, Logatherm WLW | boiler | 8 | nrgconstotal | total energy consumption | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_energy_consumption | sensor.boiler_nrgconstotal | 5 | 0 | 1 | 113 | 2 |
CS800i, Logatherm WLW | boiler | 8 | nrgconscomptotal | total energy consumption compressor | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_energy_consumption_compressor | sensor.boiler_nrgconscomptotal | 5 | 0 | 1 | 115 | 2 |
CS800i, Logatherm WLW | boiler | 8 | nrgconscompheating | energy consumption compressor heating | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_energy_consumption_compressor_heating | sensor.boiler_nrgconscompheating | 5 | 0 | 1 | 117 | 2 |
CS800i, Logatherm WLW | boiler | 8 | nrgconscomp | energy consumption compressor | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_dhw_energy_consumption_compressor | sensor.boiler_dhw_nrgconscomp | 5 | 9 | 1 | 8 | 2 |
CS800i, Logatherm WLW | boiler | 8 | nrgconscompcooling | energy consumption compressor cooling | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_energy_consumption_compressor_cooling | sensor.boiler_nrgconscompcooling | 5 | 0 | 1 | 119 | 2 |
CS800i, Logatherm WLW | boiler | 8 | nrgconscomppool | energy consumption compressor pool | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_energy_consumption_compressor_pool | sensor.boiler_nrgconscomppool | 5 | 0 | 1 | 121 | 2 |
CS800i, Logatherm WLW | boiler | 8 | auxelecheatnrgconstotal | total aux elec. heater energy consumption | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_aux_elec._heater_energy_consumption | sensor.boiler_auxelecheatnrgconstotal | 5 | 0 | 1 | 123 | 2 |
CS800i, Logatherm WLW | boiler | 8 | auxelecheatnrgconsheating | aux elec. heater energy consumption heating | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_aux_elec._heater_energy_consumption_heating | sensor.boiler_auxelecheatnrgconsheating | 5 | 0 | 1 | 125 | 2 |
CS800i, Logatherm WLW | boiler | 8 | auxelecheatnrgcons | aux elec. heater energy consumption | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_dhw_aux_elec._heater_energy_consumption | sensor.boiler_dhw_auxelecheatnrgcons | 5 | 9 | 1 | 10 | 2 |
CS800i, Logatherm WLW | boiler | 8 | auxelecheatnrgconspool | aux elec. heater energy consumption pool | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_aux_elec._heater_energy_consumption_pool | sensor.boiler_auxelecheatnrgconspool | 5 | 0 | 1 | 127 | 2 |
CS800i, Logatherm WLW | boiler | 8 | nrgsupptotal | total energy supplied | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_energy_supplied | sensor.boiler_nrgsupptotal | 5 | 0 | 1 | 129 | 2 |
CS800i, Logatherm WLW | boiler | 8 | nrgsuppheating | total energy supplied heating | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_energy_supplied_heating | sensor.boiler_nrgsuppheating | 5 | 0 | 1 | 131 | 2 |
CS800i, Logatherm WLW | boiler | 8 | nrgsupp | total energy warm supplied | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_dhw_total_energy_warm_supplied | sensor.boiler_dhw_nrgsupp | 5 | 9 | 1 | 12 | 2 |
CS800i, Logatherm WLW | boiler | 8 | nrgsuppcooling | total energy supplied cooling | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_energy_supplied_cooling | sensor.boiler_nrgsuppcooling | 5 | 0 | 1 | 133 | 2 |
CS800i, Logatherm WLW | boiler | 8 | nrgsupppool | total energy supplied pool | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_energy_supplied_pool | sensor.boiler_nrgsupppool | 5 | 0 | 1 | 135 | 2 |
CS800i, Logatherm WLW | boiler | 8 | hppower | compressor power output | uint8 (>=0<=25) | kW | False | sensor.boiler_compressor_power_output | sensor.boiler_hppower | 5 | 0 | 1/10 | 137 | 1 |
CS800i, Logatherm WLW | boiler | 8 | hpmaxpower | compressor max power | uint8 (>=0<=100) | % | True | number.boiler_compressor_max_power | number.boiler_hpmaxpower | 5 | 0 | 1 | 138 | 1 |
CS800i, Logatherm WLW | boiler | 8 | pvmaxcomp | pv compressor max power | uint8 (>=0<=25) | kW | True | number.boiler_pv_compressor_max_power | number.boiler_pvmaxcomp | 5 | 0 | 1/10 | 139 | 1 |
CS800i, Logatherm WLW | boiler | 8 | hpsetdiffpress | set differental pressure | uint8 (>=150<=750) | mbar | True | number.boiler_set_differental_pressure | number.boiler_hpsetdiffpress | 5 | 0 | 50 | 140 | 1 |
CS800i, Logatherm WLW | boiler | 8 | hpcompon | hp compressor | boolean | | False | binary_sensor.boiler_hp_compressor | binary_sensor.boiler_hpcompon | 5 | 0 | 1 | 141 | 1 |
CS800i, Logatherm WLW | boiler | 8 | hpactivity | compressor activity | enum [none|heating|cooling|hot water|pool|unknown|defrost] | | False | sensor.boiler_compressor_activity | sensor.boiler_hpactivity | 5 | 0 | 1 | 142 | 1 |
CS800i, Logatherm WLW | boiler | 8 | hpbrinepumpspd | brine pump speed | uint8 (>=0<=100) | % | False | sensor.boiler_brine_pump_speed | sensor.boiler_hpbrinepumpspd | 5 | 0 | 1 | 143 | 1 |
CS800i, Logatherm WLW | boiler | 8 | hpswitchvalve | switch valve | boolean | | False | binary_sensor.boiler_switch_valve | binary_sensor.boiler_hpswitchvalve | 5 | 0 | 1 | 144 | 1 |
CS800i, Logatherm WLW | boiler | 8 | hpcompspd | compressor speed | uint8 (>=0<=100) | % | False | sensor.boiler_compressor_speed | sensor.boiler_hpcompspd | 5 | 0 | 1 | 145 | 1 |
CS800i, Logatherm WLW | boiler | 8 | hpcircspd | circulation pump speed | uint8 (>=0<=100) | % | False | sensor.boiler_circulation_pump_speed | sensor.boiler_hpcircspd | 5 | 0 | 1 | 146 | 1 |
CS800i, Logatherm WLW | boiler | 8 | hpbrinein | brine in/evaporator | int16 (>=-3199<=3199) | C | False | sensor.boiler_brine_in/evaporator | sensor.boiler_hpbrinein | 5 | 0 | 1/10 | 147 | 1 |
CS800i, Logatherm WLW | boiler | 8 | hpbrineout | brine out/condenser | int16 (>=-3199<=3199) | C | False | sensor.boiler_brine_out/condenser | sensor.boiler_hpbrineout | 5 | 0 | 1/10 | 148 | 1 |
CS800i, Logatherm WLW | boiler | 8 | hptc0 | heat carrier return (TC0) | int16 (>=-3199<=3199) | C | False | sensor.boiler_heat_carrier_return_(TC0) | sensor.boiler_hptc0 | 5 | 0 | 1/10 | 149 | 1 |
CS800i, Logatherm WLW | boiler | 8 | hptc1 | heat carrier forward (TC1) | int16 (>=-3199<=3199) | C | False | sensor.boiler_heat_carrier_forward_(TC1) | sensor.boiler_hptc1 | 5 | 0 | 1/10 | 150 | 1 |
CS800i, Logatherm WLW | boiler | 8 | hptc3 | condenser temperature (TC3) | int16 (>=-3199<=3199) | C | False | sensor.boiler_condenser_temperature_(TC3) | sensor.boiler_hptc3 | 5 | 0 | 1/10 | 151 | 1 |
CS800i, Logatherm WLW | boiler | 8 | hptr1 | compressor temperature (TR1) | int16 (>=-3199<=3199) | C | False | sensor.boiler_compressor_temperature_(TR1) | sensor.boiler_hptr1 | 5 | 0 | 1/10 | 152 | 1 |
CS800i, Logatherm WLW | boiler | 8 | hptr3 | refrigerant temperature liquid side (condenser output) (TR3) | int16 (>=-3199<=3199) | C | False | sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3) | sensor.boiler_hptr3 | 5 | 0 | 1/10 | 153 | 1 |
CS800i, Logatherm WLW | boiler | 8 | hptr4 | evaporator inlet temperature (TR4) | int16 (>=-3199<=3199) | C | False | sensor.boiler_evaporator_inlet_temperature_(TR4) | sensor.boiler_hptr4 | 5 | 0 | 1/10 | 154 | 1 |
CS800i, Logatherm WLW | boiler | 8 | hptr5 | compressor inlet temperature (TR5) | int16 (>=-3199<=3199) | C | False | sensor.boiler_compressor_inlet_temperature_(TR5) | sensor.boiler_hptr5 | 5 | 0 | 1/10 | 155 | 1 |
CS800i, Logatherm WLW | boiler | 8 | hptr6 | compressor outlet temperature (TR6) | int16 (>=-3199<=3199) | C | False | sensor.boiler_compressor_outlet_temperature_(TR6) | sensor.boiler_hptr6 | 5 | 0 | 1/10 | 156 | 1 |
CS800i, Logatherm WLW | boiler | 8 | hptr7 | refrigerant temperature gas side (condenser input) (TR7) | int16 (>=-3199<=3199) | C | False | sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7) | sensor.boiler_hptr7 | 5 | 0 | 1/10 | 157 | 1 |
CS800i, Logatherm WLW | boiler | 8 | hptl2 | air inlet temperature (TL2) | int16 (>=-3199<=3199) | C | False | sensor.boiler_air_inlet_temperature_(TL2) | sensor.boiler_hptl2 | 5 | 0 | 1/10 | 158 | 1 |
CS800i, Logatherm WLW | boiler | 8 | hppl1 | low pressure side temperature (PL1) | int16 (>=-3199<=3199) | C | False | sensor.boiler_low_pressure_side_temperature_(PL1) | sensor.boiler_hppl1 | 5 | 0 | 1/10 | 159 | 1 |
CS800i, Logatherm WLW | boiler | 8 | hpph1 | high pressure side temperature (PH1) | int16 (>=-3199<=3199) | C | False | sensor.boiler_high_pressure_side_temperature_(PH1) | sensor.boiler_hpph1 | 5 | 0 | 1/10 | 160 | 1 |
CS800i, Logatherm WLW | boiler | 8 | hpta4 | drain pan temp (TA4) | int16 (>=-3199<=3199) | C | False | sensor.boiler_drain_pan_temp_(TA4) | sensor.boiler_hpta4 | 5 | 0 | 1/10 | 161 | 1 |
CS800i, Logatherm WLW | boiler | 8 | hptw1 | reservoir temp (TW1) | int16 (>=-3199<=3199) | C | False | sensor.boiler_reservoir_temp_(TW1) | sensor.boiler_hptw1 | 5 | 0 | 1/10 | 162 | 1 |
CS800i, Logatherm WLW | boiler | 8 | poolsettemp | pool set temperature | uint8 (>=0<=127) | C | True | number.boiler_pool_set_temperature | number.boiler_poolsettemp | 5 | 0 | 1/2 | 163 | 1 |
CS800i, Logatherm WLW | boiler | 8 | hp4way | 4-way valve (VR4) | enum [cooling & defrost|heating & dhw] | | False | sensor.boiler_4-way_valve_(VR4) | sensor.boiler_hp4way | 5 | 0 | 1 | 164 | 1 |
CS800i, Logatherm WLW | boiler | 8 | hpin1 | input 1 state | boolean | | False | binary_sensor.boiler_input_1_state | binary_sensor.boiler_hpin1 | 5 | 0 | 1 | 165 | 1 |
CS800i, Logatherm WLW | boiler | 8 | hpin1opt | input 1 options | string | | True | sensor.boiler_input_1_options | sensor.boiler_hpin1opt | 5 | 0 | 1 | 166 | 8 |
CS800i, Logatherm WLW | boiler | 8 | hpin2 | input 2 state | boolean | | False | binary_sensor.boiler_input_2_state | binary_sensor.boiler_hpin2 | 5 | 0 | 1 | 174 | 1 |
CS800i, Logatherm WLW | boiler | 8 | hpin2opt | input 2 options | string | | True | sensor.boiler_input_2_options | sensor.boiler_hpin2opt | 5 | 0 | 1 | 175 | 8 |
CS800i, Logatherm WLW | boiler | 8 | hpin3 | input 3 state | boolean | | False | binary_sensor.boiler_input_3_state | binary_sensor.boiler_hpin3 | 5 | 0 | 1 | 183 | 1 |
CS800i, Logatherm WLW | boiler | 8 | hpin3opt | input 3 options | string | | True | sensor.boiler_input_3_options | sensor.boiler_hpin3opt | 5 | 0 | 1 | 184 | 8 |
CS800i, Logatherm WLW | boiler | 8 | hpin4 | input 4 state | boolean | | False | binary_sensor.boiler_input_4_state | binary_sensor.boiler_hpin4 | 5 | 0 | 1 | 192 | 1 |
CS800i, Logatherm WLW | boiler | 8 | hpin4opt | input 4 options | string | | True | sensor.boiler_input_4_options | sensor.boiler_hpin4opt | 5 | 0 | 1 | 193 | 8 |
CS800i, Logatherm WLW | boiler | 8 | maxheatcomp | heat limit compressor | enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] | | True | select.boiler_heat_limit_compressor | select.boiler_maxheatcomp | 5 | 0 | 1 | 201 | 1 |
CS800i, Logatherm WLW | boiler | 8 | maxheatheat | heat limit heating | enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] | | True | select.boiler_heat_limit_heating | select.boiler_maxheatheat | 5 | 0 | 1 | 202 | 1 |
CS800i, Logatherm WLW | boiler | 8 | maxheat | heat limit | enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] | | True | select.boiler_dhw_heat_limit | select.boiler_dhw_maxheat | 5 | 9 | 1 | 14 | 1 |
CS800i, Logatherm WLW | boiler | 8 | mandefrost | manual defrost | boolean | | True | switch.boiler_manual_defrost | switch.boiler_mandefrost | 5 | 0 | 1 | 203 | 1 |
CS800i, Logatherm WLW | boiler | 8 | pvcooling | cooling only with PV | boolean | | True | switch.boiler_cooling_only_with_PV | switch.boiler_pvcooling | 5 | 0 | 1 | 204 | 1 |
CS800i, Logatherm WLW | boiler | 8 | auxheateronly | aux heater only | boolean | | True | switch.boiler_aux_heater_only | switch.boiler_auxheateronly | 5 | 0 | 1 | 205 | 1 |
CS800i, Logatherm WLW | boiler | 8 | auxheateroff | disable aux heater | boolean | | True | switch.boiler_disable_aux_heater | switch.boiler_auxheateroff | 5 | 0 | 1 | 206 | 1 |
CS800i, Logatherm WLW | boiler | 8 | auxheaterstatus | aux heater status | uint8 (>=0<=100) | % | False | sensor.boiler_aux_heater_status | sensor.boiler_auxheaterstatus | 5 | 0 | 1 | 207 | 1 |
CS800i, Logatherm WLW | boiler | 8 | auxheaterdelay | aux heater on delay | uint16 (>=10<=1000) | K*min | True | number.boiler_aux_heater_on_delay | number.boiler_auxheaterdelay | 5 | 0 | 10 | 208 | 1 |
CS800i, Logatherm WLW | boiler | 8 | auxmaxlimit | aux heater max limit | uint8 (>=0<=10) | K | True | number.boiler_aux_heater_max_limit | number.boiler_auxmaxlimit | 5 | 0 | 1/10 | 209 | 1 |
CS800i, Logatherm WLW | boiler | 8 | auxlimitstart | aux heater limit start | uint8 (>=0<=10) | K | True | number.boiler_aux_heater_limit_start | number.boiler_auxlimitstart | 5 | 0 | 1/10 | 210 | 1 |
CS800i, Logatherm WLW | boiler | 8 | auxheatrmode | aux heater mode | enum [eco|comfort] | | True | select.boiler_aux_heater_mode | select.boiler_auxheatrmode | 5 | 0 | 1 | 211 | 1 |
CS800i, Logatherm WLW | boiler | 8 | hphystheat | on/off hyst heat | uint16 (>=50<=1500) | K*min | True | number.boiler_on/off_hyst_heat | number.boiler_hphystheat | 5 | 0 | 5 | 212 | 1 |
CS800i, Logatherm WLW | boiler | 8 | hphystcool | on/off hyst cool | uint16 (>=50<=1500) | K*min | True | number.boiler_on/off_hyst_cool | number.boiler_hphystcool | 5 | 0 | 5 | 213 | 1 |
CS800i, Logatherm WLW | boiler | 8 | hphystpool | on/off hyst pool | uint16 (>=50<=1500) | K*min | True | number.boiler_on/off_hyst_pool | number.boiler_hphystpool | 5 | 0 | 5 | 214 | 1 |
CS800i, Logatherm WLW | boiler | 8 | silentmode | silent mode | enum [off|auto|on] | | True | select.boiler_silent_mode | select.boiler_silentmode | 5 | 0 | 1 | 215 | 1 |
CS800i, Logatherm WLW | boiler | 8 | silentfrom | silent mode from | uint8 (>=0<=3810) | minutes | True | number.boiler_silent_mode_from | number.boiler_silentfrom | 5 | 0 | 15 | 216 | 1 |
CS800i, Logatherm WLW | boiler | 8 | silentto | silent mode to | uint8 (>=0<=3810) | minutes | True | number.boiler_silent_mode_to | number.boiler_silentto | 5 | 0 | 15 | 217 | 1 |
CS800i, Logatherm WLW | boiler | 8 | mintempsilent | min outside temp for silent mode | int8 (>=-126<=126) | C | True | number.boiler_min_outside_temp_for_silent_mode | number.boiler_mintempsilent | 5 | 0 | 1 | 218 | 1 |
CS800i, Logatherm WLW | boiler | 8 | tempparmode | outside temp parallel mode | int8 (>=-126<=126) | C | True | number.boiler_outside_temp_parallel_mode | number.boiler_tempparmode | 5 | 0 | 1 | 219 | 1 |
CS800i, Logatherm WLW | boiler | 8 | auxheatmix | aux heater mixing valve | int8 (>=-100<=100) | % | False | sensor.boiler_aux_heater_mixing_valve | sensor.boiler_auxheatmix | 5 | 0 | 1 | 220 | 1 |
CS800i, Logatherm WLW | boiler | 8 | tempdiffheat | temp diff TC3/TC0 heat | uint8 (>=2<=10) | K | True | number.boiler_temp_diff_TC3/TC0_heat | number.boiler_tempdiffheat | 5 | 0 | 1/10 | 221 | 1 |
CS800i, Logatherm WLW | boiler | 8 | tempdiffcool | temp diff TC3/TC0 cool | uint8 (>=2<=10) | K | True | number.boiler_temp_diff_TC3/TC0_cool | number.boiler_tempdiffcool | 5 | 0 | 1/10 | 222 | 1 |
CS800i, Logatherm WLW | boiler | 8 | vpcooling | valve/pump cooling | boolean | | True | switch.boiler_valve/pump_cooling | switch.boiler_vpcooling | 5 | 0 | 1 | 223 | 1 |
CS800i, Logatherm WLW | boiler | 8 | heatcable | heating cable | boolean | | True | switch.boiler_heating_cable | switch.boiler_heatcable | 5 | 0 | 1 | 224 | 1 |
CS800i, Logatherm WLW | boiler | 8 | vc0valve | VC0 valve | boolean | | True | switch.boiler_VC0_valve | switch.boiler_vc0valve | 5 | 0 | 1 | 225 | 1 |
CS800i, Logatherm WLW | boiler | 8 | primepump | primary heatpump | boolean | | True | switch.boiler_primary_heatpump | switch.boiler_primepump | 5 | 0 | 1 | 226 | 1 |
CS800i, Logatherm WLW | boiler | 8 | primepumpmod | primary heatpump modulation | uint8 (>=0<=100) | % | True | number.boiler_primary_heatpump_modulation | number.boiler_primepumpmod | 5 | 0 | 1 | 227 | 1 |
CS800i, Logatherm WLW | boiler | 8 | hp3way | 3-way valve | boolean | | True | switch.boiler_3-way_valve | switch.boiler_hp3way | 5 | 0 | 1 | 228 | 1 |
CS800i, Logatherm WLW | boiler | 8 | elheatstep1 | el. heater step 1 | boolean | | True | switch.boiler_el._heater_step_1 | switch.boiler_elheatstep1 | 5 | 0 | 1 | 229 | 1 |
CS800i, Logatherm WLW | boiler | 8 | elheatstep2 | el. heater step 2 | boolean | | True | switch.boiler_el._heater_step_2 | switch.boiler_elheatstep2 | 5 | 0 | 1 | 230 | 1 |
CS800i, Logatherm WLW | boiler | 8 | elheatstep3 | el. heater step 3 | boolean | | True | switch.boiler_el._heater_step_3 | switch.boiler_elheatstep3 | 5 | 0 | 1 | 231 | 1 |
CS800i, Logatherm WLW | boiler | 8 | hpea0 | condensate reservoir heating (EA0) | boolean | | False | binary_sensor.boiler_condensate_reservoir_heating_(EA0) | binary_sensor.boiler_hpea0 | 5 | 0 | 1 | 232 | 1 |
CS800i, Logatherm WLW | boiler | 8 | hppumpmode | primary heatpump mode | enum [auto|continuous] | | True | select.boiler_primary_heatpump_mode | select.boiler_hppumpmode | 5 | 0 | 1 | 233 | 1 |
CS800i, Logatherm WLW | boiler | 8 | fan | fan | uint8 (>=20<=100) | % | True | number.boiler_fan | number.boiler_fan | 5 | 0 | 1 | 234 | 1 |
CS800i, Logatherm WLW | boiler | 8 | shutdown | shutdown | cmd [off|on] | | True | sensor.boiler_shutdown | sensor.boiler_shutdown | 5 | 0 | 1 | 235 | 1 |
CS800i, Logatherm WLW | boiler | 8 | hpcurrpower | compressor current power | uint16 (>=0<=31999) | W | False | sensor.boiler_compressor_current_power | sensor.boiler_hpcurrpower | 5 | 0 | 1 | 236 | 1 |
CS800i, Logatherm WLW | boiler | 8 | hppowerlimit | power limit | uint16 (>=0<=31999) | W | True | number.boiler_power_limit | number.boiler_hppowerlimit | 5 | 0 | 1 | 237 | 1 |
CS800i, Logatherm WLW | boiler | 8 | pc0flow | Flow PC0 | int16 (>=-31999<=31999) | l/h | False | sensor.boiler_Flow_PC0 | sensor.boiler_pc0flow | 5 | 0 | 1 | 238 | 1 |
CS800i, Logatherm WLW | boiler | 8 | pc1flow | Flow PC1 | int16 (>=-31999<=31999) | l/h | False | sensor.boiler_Flow_PC1 | sensor.boiler_pc1flow | 5 | 0 | 1 | 239 | 1 |
CS800i, Logatherm WLW | boiler | 8 | pc1on | PC1 | boolean | | False | binary_sensor.boiler_PC1 | binary_sensor.boiler_pc1on | 5 | 0 | 1 | 240 | 1 |
CS800i, Logatherm WLW | boiler | 8 | pc1rate | PC1 rate | uint8 (>=0<=100) | % | False | sensor.boiler_PC1_rate | sensor.boiler_pc1rate | 5 | 0 | 1 | 241 | 1 |
CS800i, Logatherm WLW | boiler | 8 | alternatingop | alternating operation | boolean | | True | switch.boiler_dhw_alternating_operation | switch.boiler_dhw_alternatingop | 5 | 9 | 1 | 15 | 1 |
CS800i, Logatherm WLW | boiler | 8 | altopprioheat | prioritise heating during dhw | uint8 (>=20<=120) | minutes | True | number.boiler_dhw_prioritise_heating_during_dhw | number.boiler_dhw_altopprioheat | 5 | 9 | 1 | 16 | 1 |
CS800i, Logatherm WLW | boiler | 8 | altopprio | prioritise dhw during heating | uint8 (>=30<=120) | minutes | True | number.boiler_dhw_prioritise_dhw_during_heating | number.boiler_dhw_altopprio | 5 | 9 | 1 | 17 | 1 |
CS800i, Logatherm WLW | boiler | 8 | comfoff | comfort switch off | uint8 (>=15<=65) | C | True | number.boiler_dhw_comfort_switch_off | number.boiler_dhw_comfoff | 5 | 9 | 1 | 18 | 1 |
CS800i, Logatherm WLW | boiler | 8 | ecooff | eco switch off | uint8 (>=15<=65) | C | True | number.boiler_dhw_eco_switch_off | number.boiler_dhw_ecooff | 5 | 9 | 1 | 19 | 1 |
CS800i, Logatherm WLW | boiler | 8 | ecoplusoff | eco+ switch off | uint8 (>=48<=63) | C | True | number.boiler_dhw_eco+_switch_off | number.boiler_dhw_ecoplusoff | 5 | 9 | 1 | 20 | 1 |
CS800i, Logatherm WLW | boiler | 8 | comfdiff | comfort diff | uint8 (>=6<=12) | K | True | number.boiler_dhw_comfort_diff | number.boiler_dhw_comfdiff | 5 | 9 | 1 | 21 | 1 |
CS800i, Logatherm WLW | boiler | 8 | ecodiff | eco diff | uint8 (>=6<=12) | K | True | number.boiler_dhw_eco_diff | number.boiler_dhw_ecodiff | 5 | 9 | 1 | 22 | 1 |
CS800i, Logatherm WLW | boiler | 8 | ecoplusdiff | eco+ diff | uint8 (>=6<=12) | K | True | number.boiler_dhw_eco+_diff | number.boiler_dhw_ecoplusdiff | 5 | 9 | 1 | 23 | 1 |
CS800i, Logatherm WLW | boiler | 8 | comfstop | comfort stop temp | uint8 (>=0<=254) | C | True | number.boiler_dhw_comfort_stop_temp | number.boiler_dhw_comfstop | 5 | 9 | 1 | 24 | 1 |
CS800i, Logatherm WLW | boiler | 8 | ecostop | eco stop temp | uint8 (>=0<=254) | C | True | number.boiler_dhw_eco_stop_temp | number.boiler_dhw_ecostop | 5 | 9 | 1 | 25 | 1 |
CS800i, Logatherm WLW | boiler | 8 | ecoplusstop | eco+ stop temp | uint8 (>=0<=254) | C | True | number.boiler_dhw_eco+_stop_temp | number.boiler_dhw_ecoplusstop | 5 | 9 | 1 | 26 | 1 |
CS800i, Logatherm WLW | boiler | 8 | hpcircpump | circulation pump available during dhw | boolean | | True | switch.boiler_dhw_circulation_pump_available_during_dhw | switch.boiler_dhw_hpcircpump | 5 | 9 | 1 | 27 | 1 |
CS800i, Logatherm WLW | boiler | 8 | tapactivated | turn on/off | boolean | | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | 5 | 9 | 1 | 28 | 1 |
CS800i, Logatherm WLW | boiler | 8 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp | 5 | 9 | 1 | 29 | 1 |
CS800i, Logatherm WLW | boiler | 8 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp | 5 | 9 | 1 | 30 | 1 |
CS800i, Logatherm WLW | boiler | 8 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow | 5 | 9 | 1 | 31 | 1 |
CS800i, Logatherm WLW | boiler | 8 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus | 5 | 9 | 1 | 32 | 1 |
CS800i, Logatherm WLW | boiler | 8 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff | 5 | 9 | 1 | 33 | 1 |
CS800i, Logatherm WLW | boiler | 8 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle | 5 | 9 | 1 | 34 | 1 |
CS800i, Logatherm WLW | boiler | 8 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp | 5 | 9 | 1/10 | 35 | 1 |
CS800i, Logatherm WLW | boiler | 8 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | 5 | 9 | 1 | 36 | 1 |
CS800i, Logatherm WLW | boiler | 8 | comfort | comfort | enum [hot|eco|intelligent] | | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | 5 | 9 | 1 | 37 | 1 |
CS800i, Logatherm WLW | boiler | 8 | comfort1 | comfort mode | enum [high comfort|eco] | | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | 5 | 9 | 1 | 38 | 1 |
CS800i, Logatherm WLW | boiler | 8 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset | 5 | 9 | 1 | 39 | 1 |
CS800i, Logatherm WLW | boiler | 8 | chargeoptimization | charge optimization | boolean | | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | 5 | 9 | 1 | 40 | 1 |
CS800i, Logatherm WLW | boiler | 8 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower | 5 | 9 | 1 | 41 | 1 |
CS800i, Logatherm WLW | boiler | 8 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp | 5 | 9 | 1 | 42 | 1 |
CS800i, Logatherm WLW | boiler | 8 | circpump | circulation pump available | boolean | | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | 5 | 9 | 1 | 43 | 1 |
CS800i, Logatherm WLW | boiler | 8 | chargetype | charging type | enum [chargepump|3-way valve] | | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | 5 | 9 | 1 | 44 | 1 |
CS800i, Logatherm WLW | boiler | 8 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston | 5 | 9 | 1 | 45 | 1 |
CS800i, Logatherm WLW | boiler | 8 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff | 5 | 9 | 1 | 46 | 1 |
CS800i, Logatherm WLW | boiler | 8 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp | 5 | 9 | 1 | 47 | 1 |
CS800i, Logatherm WLW | boiler | 8 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | 5 | 9 | 1 | 48 | 1 |
CS800i, Logatherm WLW | boiler | 8 | circ | circulation active | boolean | | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | 5 | 9 | 1 | 49 | 1 |
CS800i, Logatherm WLW | boiler | 8 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp | 5 | 9 | 1/10 | 50 | 1 |
CS800i, Logatherm WLW | boiler | 8 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 | 5 | 9 | 1/10 | 51 | 1 |
CS800i, Logatherm WLW | boiler | 8 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow | 5 | 9 | 1/10 | 52 | 1 |
CS800i, Logatherm WLW | boiler | 8 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 | 5 | 9 | 1/10 | 53 | 1 |
CS800i, Logatherm WLW | boiler | 8 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 | 5 | 9 | 1/10 | 54 | 1 |
CS800i, Logatherm WLW | boiler | 8 | activated | activated | boolean | | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | 5 | 9 | 1 | 55 | 1 |
CS800i, Logatherm WLW | boiler | 8 | onetime | one time charging | boolean | | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | 5 | 9 | 1 | 56 | 1 |
CS800i, Logatherm WLW | boiler | 8 | disinfecting | disinfecting | boolean | | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | 5 | 9 | 1 | 57 | 1 |
CS800i, Logatherm WLW | boiler | 8 | charging | charging | boolean | | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | 5 | 9 | 1 | 58 | 1 |
CS800i, Logatherm WLW | boiler | 8 | recharging | recharging | boolean | | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | 5 | 9 | 1 | 59 | 1 |
CS800i, Logatherm WLW | boiler | 8 | tempok | temperature ok | boolean | | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | 5 | 9 | 1 | 60 | 1 |
CS800i, Logatherm WLW | boiler | 8 | active | active | boolean | | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | 5 | 9 | 1 | 61 | 1 |
CS800i, Logatherm WLW | boiler | 8 | 3wayvalve | 3-way valve active | boolean | | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | 5 | 9 | 1 | 62 | 1 |
CS800i, Logatherm WLW | boiler | 8 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp | 5 | 9 | 1/10 | 63 | 1 |
CS800i, Logatherm WLW | boiler | 8 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp | 5 | 9 | 1/10 | 64 | 1 |
CS800i, Logatherm WLW | boiler | 8 | starts | starts | uint24 (>=0<=16777213) | | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | 5 | 9 | 1 | 65 | 2 |
CS800i, Logatherm WLW | boiler | 8 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm | 5 | 9 | 1 | 67 | 2 |
C1200W | boiler | 12 | reset | reset | cmd [-|maintenance|error|history|message] | | True | sensor.boiler_reset | sensor.boiler_reset | 5 | 0 | 1 | 0 | 1 |
C1200W | boiler | 12 | heatingoff | force heating off | boolean | | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | 5 | 0 | 1 | 1 | 1 |
C1200W | boiler | 12 | heatingactive | heating active | boolean | | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | 5 | 0 | 1 | 2 | 1 |
C1200W | boiler | 12 | tapwateractive | tapwater active | boolean | | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | 5 | 0 | 1 | 3 | 1 |
C1200W | boiler | 12 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp | 5 | 0 | 1 | 4 | 1 |
C1200W | boiler | 12 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod | 5 | 0 | 1 | 5 | 1 |
C1200W | boiler | 12 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp | 5 | 0 | 1/10 | 6 | 1 |
C1200W | boiler | 12 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp | 5 | 0 | 1/10 | 7 | 1 |
C1200W | boiler | 12 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp | 5 | 0 | 1/10 | 8 | 1 |
C1200W | boiler | 12 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp | 5 | 0 | 1/10 | 9 | 1 |
C1200W | boiler | 12 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress | 5 | 0 | 1/10 | 10 | 1 |
C1200W | boiler | 12 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp | 5 | 0 | 1/10 | 11 | 1 |
C1200W | boiler | 12 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp | 5 | 0 | 1/10 | 12 | 1 |
C1200W | boiler | 12 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp | 5 | 0 | 1/10 | 242 | 1 |
C1200W | boiler | 12 | burngas | gas | boolean | | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | 5 | 0 | 1 | 243 | 1 |
C1200W | boiler | 12 | burngas2 | gas stage 2 | boolean | | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | 5 | 0 | 1 | 244 | 1 |
C1200W | boiler | 12 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr | 5 | 0 | 1/10 | 245 | 1 |
C1200W | boiler | 12 | fanwork | fan | boolean | | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | 5 | 0 | 1 | 246 | 1 |
C1200W | boiler | 12 | ignwork | ignition | boolean | | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | 5 | 0 | 1 | 247 | 1 |
C1200W | boiler | 12 | oilpreheat | oil preheating | boolean | | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | 5 | 0 | 1 | 248 | 1 |
C1200W | boiler | 12 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower | 5 | 0 | 1 | 249 | 1 |
C1200W | boiler | 12 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower | 5 | 0 | 1 | 250 | 1 |
C1200W | boiler | 12 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod | 5 | 0 | 1 | 251 | 1 |
C1200W | boiler | 12 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow | 5 | 0 | 1 | 252 | 1 |
C1200W | boiler | 12 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock | 5 | 0 | 1/10 | 253 | 1 |
C1200W | boiler | 12 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston | 5 | 0 | 1 | 254 | 1 |
C1200W | boiler | 12 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff | 5 | 0 | 1 | 255 | 1 |
C1200W | boiler | 12 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston | 5 | 0 | 1 | 256 | 1 |
C1200W | boiler | 12 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff | 5 | 0 | 1 | 257 | 1 |
C1200W | boiler | 12 | curveon | heatingcurve on | boolean | | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | 5 | 0 | 1 | 258 | 1 |
C1200W | boiler | 12 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase | 5 | 0 | 1 | 259 | 1 |
C1200W | boiler | 12 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend | 5 | 0 | 1 | 260 | 1 |
C1200W | boiler | 12 | summertemp | summer temperature | uint8 (>=0<=45) | C | True | number.boiler_summer_temperature | number.boiler_summertemp | 5 | 0 | 1 | 261 | 1 |
C1200W | boiler | 12 | nofrostmode | nofrost mode | boolean | | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | 5 | 0 | 1 | 262 | 1 |
C1200W | boiler | 12 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp | 5 | 0 | 1 | 263 | 1 |
C1200W | boiler | 12 | heatingactivated | heating activated | boolean | | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | 5 | 0 | 1 | 13 | 1 |
C1200W | boiler | 12 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp | 5 | 0 | 1 | 14 | 1 |
C1200W | boiler | 12 | heatingpump | heating pump | boolean | | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | 5 | 0 | 1 | 15 | 1 |
C1200W | boiler | 12 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax | 5 | 0 | 1 | 16 | 1 |
C1200W | boiler | 12 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin | 5 | 0 | 1 | 17 | 1 |
C1200W | boiler | 12 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | 5 | 0 | 1 | 18 | 1 |
C1200W | boiler | 12 | pumpcharacter | boiler pump characteristic | enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] | | True | select.boiler_boiler_pump_characteristic | select.boiler_pumpcharacter | 5 | 0 | 1 | 19 | 1 |
C1200W | boiler | 12 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay | 5 | 0 | 1 | 20 | 1 |
C1200W | boiler | 12 | pumpontemp | pump logic temperature | uint8 (>=0<=60) | C | True | number.boiler_pump_logic_temperature | number.boiler_pumpontemp | 5 | 0 | 1 | 21 | 1 |
C1200W | boiler | 12 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow | 5 | 0 | 1 | 22 | 1 |
C1200W | boiler | 12 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow | 5 | 0 | 1 | 23 | 1 |
C1200W | boiler | 12 | burnstarts | burner starts | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | 5 | 0 | 1 | 24 | 2 |
C1200W | boiler | 12 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin | 5 | 0 | 1 | 26 | 2 |
C1200W | boiler | 12 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin | 5 | 0 | 1 | 28 | 2 |
C1200W | boiler | 12 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin | 5 | 0 | 1 | 30 | 2 |
C1200W | boiler | 12 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | 5 | 0 | 1 | 32 | 2 |
C1200W | boiler | 12 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime | 5 | 0 | 1 | 34 | 2 |
C1200W | boiler | 12 | lastcode | last error code | string | | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | 5 | 0 | 1 | 36 | 28 |
C1200W | boiler | 12 | servicecode | service code | string | | False | sensor.boiler_service_code | sensor.boiler_servicecode | 5 | 0 | 1 | 64 | 2 |
C1200W | boiler | 12 | servicecodenumber | service code number | uint16 (>=0<=31999) | | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | 5 | 0 | 1 | 66 | 1 |
C1200W | boiler | 12 | maintenancemessage | maintenance message | string | | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | 5 | 0 | 1 | 67 | 2 |
C1200W | boiler | 12 | maintenance | maintenance scheduled | enum [off|time|date|manual] | | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | 5 | 0 | 1 | 69 | 1 |
C1200W | boiler | 12 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime | 5 | 0 | 1 | 70 | 1 |
C1200W | boiler | 12 | maintenancedate | next maintenance date | string | | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | 5 | 0 | 1 | 71 | 6 |
C1200W | boiler | 12 | emergencyops | emergency operation | boolean | | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | 5 | 0 | 1 | 77 | 1 |
C1200W | boiler | 12 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp | 5 | 0 | 1 | 78 | 1 |
C1200W | boiler | 12 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat | 5 | 0 | 1/10 | 91 | 2 |
C1200W | boiler | 12 | meter | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meter | 5 | 9 | 1/10 | 2 | 2 |
C1200W | boiler | 12 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat | 5 | 0 | 1/10 | 264 | 2 |
C1200W | boiler | 12 | gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeter | 5 | 9 | 1/10 | 69 | 2 |
C1200W | boiler | 12 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 | 5 | 0 | 1/10 | 266 | 2 |
C1200W | boiler | 12 | nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrg2 | 5 | 9 | 1/10 | 71 | 2 |
C1200W | boiler | 12 | tapactivated | turn on/off | boolean | | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | 5 | 9 | 1 | 28 | 1 |
C1200W | boiler | 12 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp | 5 | 9 | 1 | 29 | 1 |
C1200W | boiler | 12 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp | 5 | 9 | 1 | 30 | 1 |
C1200W | boiler | 12 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow | 5 | 9 | 1 | 31 | 1 |
C1200W | boiler | 12 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus | 5 | 9 | 1 | 32 | 1 |
C1200W | boiler | 12 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff | 5 | 9 | 1 | 33 | 1 |
C1200W | boiler | 12 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle | 5 | 9 | 1 | 34 | 1 |
C1200W | boiler | 12 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp | 5 | 9 | 1/10 | 35 | 1 |
C1200W | boiler | 12 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | 5 | 9 | 1 | 36 | 1 |
C1200W | boiler | 12 | comfort | comfort | enum [hot|eco|intelligent] | | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | 5 | 9 | 1 | 37 | 1 |
C1200W | boiler | 12 | comfort1 | comfort mode | enum [high comfort|eco] | | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | 5 | 9 | 1 | 38 | 1 |
C1200W | boiler | 12 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset | 5 | 9 | 1 | 39 | 1 |
C1200W | boiler | 12 | chargeoptimization | charge optimization | boolean | | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | 5 | 9 | 1 | 40 | 1 |
C1200W | boiler | 12 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower | 5 | 9 | 1 | 41 | 1 |
C1200W | boiler | 12 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp | 5 | 9 | 1 | 42 | 1 |
C1200W | boiler | 12 | circpump | circulation pump available | boolean | | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | 5 | 9 | 1 | 43 | 1 |
C1200W | boiler | 12 | chargetype | charging type | enum [chargepump|3-way valve] | | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | 5 | 9 | 1 | 44 | 1 |
C1200W | boiler | 12 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston | 5 | 9 | 1 | 45 | 1 |
C1200W | boiler | 12 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff | 5 | 9 | 1 | 46 | 1 |
C1200W | boiler | 12 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp | 5 | 9 | 1 | 47 | 1 |
C1200W | boiler | 12 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | 5 | 9 | 1 | 48 | 1 |
C1200W | boiler | 12 | circ | circulation active | boolean | | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | 5 | 9 | 1 | 49 | 1 |
C1200W | boiler | 12 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp | 5 | 9 | 1/10 | 50 | 1 |
C1200W | boiler | 12 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 | 5 | 9 | 1/10 | 51 | 1 |
C1200W | boiler | 12 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow | 5 | 9 | 1/10 | 52 | 1 |
C1200W | boiler | 12 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 | 5 | 9 | 1/10 | 53 | 1 |
C1200W | boiler | 12 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 | 5 | 9 | 1/10 | 54 | 1 |
C1200W | boiler | 12 | activated | activated | boolean | | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | 5 | 9 | 1 | 55 | 1 |
C1200W | boiler | 12 | onetime | one time charging | boolean | | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | 5 | 9 | 1 | 56 | 1 |
C1200W | boiler | 12 | disinfecting | disinfecting | boolean | | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | 5 | 9 | 1 | 57 | 1 |
C1200W | boiler | 12 | charging | charging | boolean | | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | 5 | 9 | 1 | 58 | 1 |
C1200W | boiler | 12 | recharging | recharging | boolean | | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | 5 | 9 | 1 | 59 | 1 |
C1200W | boiler | 12 | tempok | temperature ok | boolean | | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | 5 | 9 | 1 | 60 | 1 |
C1200W | boiler | 12 | active | active | boolean | | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | 5 | 9 | 1 | 61 | 1 |
C1200W | boiler | 12 | 3wayvalve | 3-way valve active | boolean | | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | 5 | 9 | 1 | 62 | 1 |
C1200W | boiler | 12 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp | 5 | 9 | 1/10 | 63 | 1 |
C1200W | boiler | 12 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp | 5 | 9 | 1/10 | 64 | 1 |
C1200W | boiler | 12 | starts | starts | uint24 (>=0<=16777213) | | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | 5 | 9 | 1 | 65 | 2 |
C1200W | boiler | 12 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm | 5 | 9 | 1 | 67 | 2 |
C1200W | boiler | 12 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower | 5 | 0 | 1 | 268 | 1 |
C1200W | boiler | 12 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal | 5 | 0 | 1/100 | 79 | 2 |
C1200W | boiler | 12 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat | 5 | 0 | 1/100 | 81 | 2 |
C1200W | boiler | 12 | nrg | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrg | 5 | 9 | 1/100 | 0 | 2 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | reset | reset | cmd [-|maintenance|error|history|message] | | True | sensor.boiler_reset | sensor.boiler_reset | 5 | 0 | 1 | 0 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | heatingoff | force heating off | boolean | | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | 5 | 0 | 1 | 1 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | heatingactive | heating active | boolean | | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | 5 | 0 | 1 | 2 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | tapwateractive | tapwater active | boolean | | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | 5 | 0 | 1 | 3 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp | 5 | 0 | 1 | 4 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod | 5 | 0 | 1 | 5 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp | 5 | 0 | 1/10 | 6 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp | 5 | 0 | 1/10 | 7 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp | 5 | 0 | 1/10 | 8 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp | 5 | 0 | 1/10 | 9 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress | 5 | 0 | 1/10 | 10 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp | 5 | 0 | 1/10 | 11 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp | 5 | 0 | 1/10 | 12 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp | 5 | 0 | 1/10 | 242 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | burngas | gas | boolean | | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | 5 | 0 | 1 | 243 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | burngas2 | gas stage 2 | boolean | | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | 5 | 0 | 1 | 244 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr | 5 | 0 | 1/10 | 245 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | fanwork | fan | boolean | | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | 5 | 0 | 1 | 246 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | ignwork | ignition | boolean | | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | 5 | 0 | 1 | 247 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | oilpreheat | oil preheating | boolean | | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | 5 | 0 | 1 | 248 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower | 5 | 0 | 1 | 249 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower | 5 | 0 | 1 | 250 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod | 5 | 0 | 1 | 251 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow | 5 | 0 | 1 | 252 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock | 5 | 0 | 1/10 | 253 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston | 5 | 0 | 1 | 254 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff | 5 | 0 | 1 | 255 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston | 5 | 0 | 1 | 256 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff | 5 | 0 | 1 | 257 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | curveon | heatingcurve on | boolean | | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | 5 | 0 | 1 | 258 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase | 5 | 0 | 1 | 259 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend | 5 | 0 | 1 | 260 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | summertemp | summer temperature | uint8 (>=0<=45) | C | True | number.boiler_summer_temperature | number.boiler_summertemp | 5 | 0 | 1 | 261 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | nofrostmode | nofrost mode | boolean | | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | 5 | 0 | 1 | 262 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp | 5 | 0 | 1 | 263 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | heatingactivated | heating activated | boolean | | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | 5 | 0 | 1 | 13 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp | 5 | 0 | 1 | 14 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | heatingpump | heating pump | boolean | | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | 5 | 0 | 1 | 15 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax | 5 | 0 | 1 | 16 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin | 5 | 0 | 1 | 17 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | 5 | 0 | 1 | 18 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | pumpcharacter | boiler pump characteristic | enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] | | True | select.boiler_boiler_pump_characteristic | select.boiler_pumpcharacter | 5 | 0 | 1 | 19 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay | 5 | 0 | 1 | 20 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | pumpontemp | pump logic temperature | uint8 (>=0<=60) | C | True | number.boiler_pump_logic_temperature | number.boiler_pumpontemp | 5 | 0 | 1 | 21 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow | 5 | 0 | 1 | 22 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow | 5 | 0 | 1 | 23 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | burnstarts | burner starts | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | 5 | 0 | 1 | 24 | 2 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin | 5 | 0 | 1 | 26 | 2 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin | 5 | 0 | 1 | 28 | 2 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin | 5 | 0 | 1 | 30 | 2 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | 5 | 0 | 1 | 32 | 2 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime | 5 | 0 | 1 | 34 | 2 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | lastcode | last error code | string | | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | 5 | 0 | 1 | 36 | 28 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | servicecode | service code | string | | False | sensor.boiler_service_code | sensor.boiler_servicecode | 5 | 0 | 1 | 64 | 2 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | servicecodenumber | service code number | uint16 (>=0<=31999) | | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | 5 | 0 | 1 | 66 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | maintenancemessage | maintenance message | string | | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | 5 | 0 | 1 | 67 | 2 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | maintenance | maintenance scheduled | enum [off|time|date|manual] | | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | 5 | 0 | 1 | 69 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime | 5 | 0 | 1 | 70 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | maintenancedate | next maintenance date | string | | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | 5 | 0 | 1 | 71 | 6 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | emergencyops | emergency operation | boolean | | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | 5 | 0 | 1 | 77 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp | 5 | 0 | 1 | 78 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat | 5 | 0 | 1/10 | 91 | 2 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | meter | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meter | 5 | 9 | 1/10 | 2 | 2 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat | 5 | 0 | 1/10 | 264 | 2 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeter | 5 | 9 | 1/10 | 69 | 2 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 | 5 | 0 | 1/10 | 266 | 2 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrg2 | 5 | 9 | 1/10 | 71 | 2 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | tapactivated | turn on/off | boolean | | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | 5 | 9 | 1 | 28 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp | 5 | 9 | 1 | 29 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp | 5 | 9 | 1 | 30 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow | 5 | 9 | 1 | 31 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus | 5 | 9 | 1 | 32 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff | 5 | 9 | 1 | 33 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle | 5 | 9 | 1 | 34 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp | 5 | 9 | 1/10 | 35 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | 5 | 9 | 1 | 36 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | comfort | comfort | enum [hot|eco|intelligent] | | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | 5 | 9 | 1 | 37 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | comfort1 | comfort mode | enum [high comfort|eco] | | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | 5 | 9 | 1 | 38 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset | 5 | 9 | 1 | 39 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | chargeoptimization | charge optimization | boolean | | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | 5 | 9 | 1 | 40 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower | 5 | 9 | 1 | 41 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp | 5 | 9 | 1 | 42 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | circpump | circulation pump available | boolean | | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | 5 | 9 | 1 | 43 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | chargetype | charging type | enum [chargepump|3-way valve] | | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | 5 | 9 | 1 | 44 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston | 5 | 9 | 1 | 45 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff | 5 | 9 | 1 | 46 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp | 5 | 9 | 1 | 47 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | 5 | 9 | 1 | 48 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | circ | circulation active | boolean | | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | 5 | 9 | 1 | 49 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp | 5 | 9 | 1/10 | 50 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 | 5 | 9 | 1/10 | 51 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow | 5 | 9 | 1/10 | 52 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 | 5 | 9 | 1/10 | 53 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 | 5 | 9 | 1/10 | 54 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | activated | activated | boolean | | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | 5 | 9 | 1 | 55 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | onetime | one time charging | boolean | | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | 5 | 9 | 1 | 56 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | disinfecting | disinfecting | boolean | | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | 5 | 9 | 1 | 57 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | charging | charging | boolean | | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | 5 | 9 | 1 | 58 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | recharging | recharging | boolean | | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | 5 | 9 | 1 | 59 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | tempok | temperature ok | boolean | | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | 5 | 9 | 1 | 60 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | active | active | boolean | | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | 5 | 9 | 1 | 61 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | 3wayvalve | 3-way valve active | boolean | | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | 5 | 9 | 1 | 62 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp | 5 | 9 | 1/10 | 63 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp | 5 | 9 | 1/10 | 64 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | starts | starts | uint24 (>=0<=16777213) | | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | 5 | 9 | 1 | 65 | 2 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm | 5 | 9 | 1 | 67 | 2 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower | 5 | 0 | 1 | 268 | 1 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal | 5 | 0 | 1/100 | 79 | 2 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat | 5 | 0 | 1/100 | 81 | 2 |
BK13/BK15, Smartline, GB1*2 | boiler | 64 | nrg | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrg | 5 | 9 | 1/100 | 0 | 2 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | reset | reset | cmd [-|maintenance|error|history|message] | | True | sensor.boiler_reset | sensor.boiler_reset | 5 | 0 | 1 | 0 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | heatingoff | force heating off | boolean | | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | 5 | 0 | 1 | 1 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | heatingactive | heating active | boolean | | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | 5 | 0 | 1 | 2 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | tapwateractive | tapwater active | boolean | | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | 5 | 0 | 1 | 3 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp | 5 | 0 | 1 | 4 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod | 5 | 0 | 1 | 5 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp | 5 | 0 | 1/10 | 6 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp | 5 | 0 | 1/10 | 7 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp | 5 | 0 | 1/10 | 8 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp | 5 | 0 | 1/10 | 9 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress | 5 | 0 | 1/10 | 10 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp | 5 | 0 | 1/10 | 11 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp | 5 | 0 | 1/10 | 12 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp | 5 | 0 | 1/10 | 242 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | burngas | gas | boolean | | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | 5 | 0 | 1 | 243 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | burngas2 | gas stage 2 | boolean | | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | 5 | 0 | 1 | 244 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr | 5 | 0 | 1/10 | 245 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | fanwork | fan | boolean | | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | 5 | 0 | 1 | 246 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | ignwork | ignition | boolean | | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | 5 | 0 | 1 | 247 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | oilpreheat | oil preheating | boolean | | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | 5 | 0 | 1 | 248 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower | 5 | 0 | 1 | 249 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower | 5 | 0 | 1 | 250 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod | 5 | 0 | 1 | 251 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow | 5 | 0 | 1 | 252 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock | 5 | 0 | 1/10 | 253 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston | 5 | 0 | 1 | 254 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff | 5 | 0 | 1 | 255 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston | 5 | 0 | 1 | 256 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff | 5 | 0 | 1 | 257 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | curveon | heatingcurve on | boolean | | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | 5 | 0 | 1 | 258 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase | 5 | 0 | 1 | 259 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend | 5 | 0 | 1 | 260 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | summertemp | summer temperature | uint8 (>=0<=45) | C | True | number.boiler_summer_temperature | number.boiler_summertemp | 5 | 0 | 1 | 261 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | nofrostmode | nofrost mode | boolean | | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | 5 | 0 | 1 | 262 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp | 5 | 0 | 1 | 263 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | heatingactivated | heating activated | boolean | | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | 5 | 0 | 1 | 13 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp | 5 | 0 | 1 | 14 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | heatingpump | heating pump | boolean | | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | 5 | 0 | 1 | 15 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax | 5 | 0 | 1 | 16 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin | 5 | 0 | 1 | 17 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | 5 | 0 | 1 | 18 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | pumpcharacter | boiler pump characteristic | enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] | | True | select.boiler_boiler_pump_characteristic | select.boiler_pumpcharacter | 5 | 0 | 1 | 19 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay | 5 | 0 | 1 | 20 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | pumpontemp | pump logic temperature | uint8 (>=0<=60) | C | True | number.boiler_pump_logic_temperature | number.boiler_pumpontemp | 5 | 0 | 1 | 21 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow | 5 | 0 | 1 | 22 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow | 5 | 0 | 1 | 23 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | burnstarts | burner starts | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | 5 | 0 | 1 | 24 | 2 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin | 5 | 0 | 1 | 26 | 2 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin | 5 | 0 | 1 | 28 | 2 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin | 5 | 0 | 1 | 30 | 2 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | 5 | 0 | 1 | 32 | 2 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime | 5 | 0 | 1 | 34 | 2 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | lastcode | last error code | string | | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | 5 | 0 | 1 | 36 | 28 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | servicecode | service code | string | | False | sensor.boiler_service_code | sensor.boiler_servicecode | 5 | 0 | 1 | 64 | 2 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | servicecodenumber | service code number | uint16 (>=0<=31999) | | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | 5 | 0 | 1 | 66 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | maintenancemessage | maintenance message | string | | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | 5 | 0 | 1 | 67 | 2 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | maintenance | maintenance scheduled | enum [off|time|date|manual] | | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | 5 | 0 | 1 | 69 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime | 5 | 0 | 1 | 70 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | maintenancedate | next maintenance date | string | | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | 5 | 0 | 1 | 71 | 6 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | emergencyops | emergency operation | boolean | | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | 5 | 0 | 1 | 77 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp | 5 | 0 | 1 | 78 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat | 5 | 0 | 1/10 | 91 | 2 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | meter | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meter | 5 | 9 | 1/10 | 2 | 2 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat | 5 | 0 | 1/10 | 264 | 2 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeter | 5 | 9 | 1/10 | 69 | 2 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 | 5 | 0 | 1/10 | 266 | 2 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrg2 | 5 | 9 | 1/10 | 71 | 2 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | tapactivated | turn on/off | boolean | | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | 5 | 9 | 1 | 28 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp | 5 | 9 | 1 | 29 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp | 5 | 9 | 1 | 30 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow | 5 | 9 | 1 | 31 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus | 5 | 9 | 1 | 32 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff | 5 | 9 | 1 | 33 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle | 5 | 9 | 1 | 34 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp | 5 | 9 | 1/10 | 35 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | 5 | 9 | 1 | 36 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | comfort | comfort | enum [hot|eco|intelligent] | | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | 5 | 9 | 1 | 37 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | comfort1 | comfort mode | enum [high comfort|eco] | | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | 5 | 9 | 1 | 38 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset | 5 | 9 | 1 | 39 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | chargeoptimization | charge optimization | boolean | | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | 5 | 9 | 1 | 40 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower | 5 | 9 | 1 | 41 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp | 5 | 9 | 1 | 42 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | circpump | circulation pump available | boolean | | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | 5 | 9 | 1 | 43 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | chargetype | charging type | enum [chargepump|3-way valve] | | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | 5 | 9 | 1 | 44 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston | 5 | 9 | 1 | 45 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff | 5 | 9 | 1 | 46 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp | 5 | 9 | 1 | 47 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | 5 | 9 | 1 | 48 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | circ | circulation active | boolean | | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | 5 | 9 | 1 | 49 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp | 5 | 9 | 1/10 | 50 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 | 5 | 9 | 1/10 | 51 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow | 5 | 9 | 1/10 | 52 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 | 5 | 9 | 1/10 | 53 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 | 5 | 9 | 1/10 | 54 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | activated | activated | boolean | | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | 5 | 9 | 1 | 55 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | onetime | one time charging | boolean | | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | 5 | 9 | 1 | 56 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | disinfecting | disinfecting | boolean | | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | 5 | 9 | 1 | 57 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | charging | charging | boolean | | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | 5 | 9 | 1 | 58 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | recharging | recharging | boolean | | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | 5 | 9 | 1 | 59 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | tempok | temperature ok | boolean | | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | 5 | 9 | 1 | 60 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | active | active | boolean | | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | 5 | 9 | 1 | 61 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | 3wayvalve | 3-way valve active | boolean | | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | 5 | 9 | 1 | 62 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp | 5 | 9 | 1/10 | 63 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp | 5 | 9 | 1/10 | 64 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | starts | starts | uint24 (>=0<=16777213) | | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | 5 | 9 | 1 | 65 | 2 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm | 5 | 9 | 1 | 67 | 2 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower | 5 | 0 | 1 | 268 | 1 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal | 5 | 0 | 1/100 | 79 | 2 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat | 5 | 0 | 1/100 | 81 | 2 |
Logano GB1*5, Logamatic MC10 | boiler | 72 | nrg | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrg | 5 | 9 | 1/100 | 0 | 2 |
Cascade CM10 | boiler | 81 | reset | reset | cmd [-|maintenance|error|history|message] | | True | sensor.boiler_reset | sensor.boiler_reset | 5 | 0 | 1 | 0 | 1 |
Cascade CM10 | boiler | 81 | heatingoff | force heating off | boolean | | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | 5 | 0 | 1 | 1 | 1 |
Cascade CM10 | boiler | 81 | heatingactive | heating active | boolean | | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | 5 | 0 | 1 | 2 | 1 |
Cascade CM10 | boiler | 81 | tapwateractive | tapwater active | boolean | | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | 5 | 0 | 1 | 3 | 1 |
Cascade CM10 | boiler | 81 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp | 5 | 0 | 1 | 4 | 1 |
Cascade CM10 | boiler | 81 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod | 5 | 0 | 1 | 5 | 1 |
Cascade CM10 | boiler | 81 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp | 5 | 0 | 1/10 | 6 | 1 |
Cascade CM10 | boiler | 81 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp | 5 | 0 | 1/10 | 7 | 1 |
Cascade CM10 | boiler | 81 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp | 5 | 0 | 1/10 | 8 | 1 |
Cascade CM10 | boiler | 81 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp | 5 | 0 | 1/10 | 9 | 1 |
Cascade CM10 | boiler | 81 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress | 5 | 0 | 1/10 | 10 | 1 |
Cascade CM10 | boiler | 81 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp | 5 | 0 | 1/10 | 11 | 1 |
Cascade CM10 | boiler | 81 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp | 5 | 0 | 1/10 | 12 | 1 |
Cascade CM10 | boiler | 81 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp | 5 | 0 | 1/10 | 242 | 1 |
Cascade CM10 | boiler | 81 | burngas | gas | boolean | | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | 5 | 0 | 1 | 243 | 1 |
Cascade CM10 | boiler | 81 | burngas2 | gas stage 2 | boolean | | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | 5 | 0 | 1 | 244 | 1 |
Cascade CM10 | boiler | 81 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr | 5 | 0 | 1/10 | 245 | 1 |
Cascade CM10 | boiler | 81 | fanwork | fan | boolean | | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | 5 | 0 | 1 | 246 | 1 |
Cascade CM10 | boiler | 81 | ignwork | ignition | boolean | | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | 5 | 0 | 1 | 247 | 1 |
Cascade CM10 | boiler | 81 | oilpreheat | oil preheating | boolean | | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | 5 | 0 | 1 | 248 | 1 |
Cascade CM10 | boiler | 81 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower | 5 | 0 | 1 | 249 | 1 |
Cascade CM10 | boiler | 81 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower | 5 | 0 | 1 | 250 | 1 |
Cascade CM10 | boiler | 81 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod | 5 | 0 | 1 | 251 | 1 |
Cascade CM10 | boiler | 81 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow | 5 | 0 | 1 | 252 | 1 |
Cascade CM10 | boiler | 81 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock | 5 | 0 | 1/10 | 253 | 1 |
Cascade CM10 | boiler | 81 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston | 5 | 0 | 1 | 254 | 1 |
Cascade CM10 | boiler | 81 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff | 5 | 0 | 1 | 255 | 1 |
Cascade CM10 | boiler | 81 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston | 5 | 0 | 1 | 256 | 1 |
Cascade CM10 | boiler | 81 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff | 5 | 0 | 1 | 257 | 1 |
Cascade CM10 | boiler | 81 | curveon | heatingcurve on | boolean | | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | 5 | 0 | 1 | 258 | 1 |
Cascade CM10 | boiler | 81 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase | 5 | 0 | 1 | 259 | 1 |
Cascade CM10 | boiler | 81 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend | 5 | 0 | 1 | 260 | 1 |
Cascade CM10 | boiler | 81 | summertemp | summer temperature | uint8 (>=0<=45) | C | True | number.boiler_summer_temperature | number.boiler_summertemp | 5 | 0 | 1 | 261 | 1 |
Cascade CM10 | boiler | 81 | nofrostmode | nofrost mode | boolean | | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | 5 | 0 | 1 | 262 | 1 |
Cascade CM10 | boiler | 81 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp | 5 | 0 | 1 | 263 | 1 |
Cascade CM10 | boiler | 81 | heatingactivated | heating activated | boolean | | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | 5 | 0 | 1 | 13 | 1 |
Cascade CM10 | boiler | 81 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp | 5 | 0 | 1 | 14 | 1 |
Cascade CM10 | boiler | 81 | heatingpump | heating pump | boolean | | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | 5 | 0 | 1 | 15 | 1 |
Cascade CM10 | boiler | 81 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax | 5 | 0 | 1 | 16 | 1 |
Cascade CM10 | boiler | 81 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin | 5 | 0 | 1 | 17 | 1 |
Cascade CM10 | boiler | 81 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | 5 | 0 | 1 | 18 | 1 |
Cascade CM10 | boiler | 81 | pumpcharacter | boiler pump characteristic | enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] | | True | select.boiler_boiler_pump_characteristic | select.boiler_pumpcharacter | 5 | 0 | 1 | 19 | 1 |
Cascade CM10 | boiler | 81 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay | 5 | 0 | 1 | 20 | 1 |
Cascade CM10 | boiler | 81 | pumpontemp | pump logic temperature | uint8 (>=0<=60) | C | True | number.boiler_pump_logic_temperature | number.boiler_pumpontemp | 5 | 0 | 1 | 21 | 1 |
Cascade CM10 | boiler | 81 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow | 5 | 0 | 1 | 22 | 1 |
Cascade CM10 | boiler | 81 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow | 5 | 0 | 1 | 23 | 1 |
Cascade CM10 | boiler | 81 | burnstarts | burner starts | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | 5 | 0 | 1 | 24 | 2 |
Cascade CM10 | boiler | 81 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin | 5 | 0 | 1 | 26 | 2 |
Cascade CM10 | boiler | 81 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin | 5 | 0 | 1 | 28 | 2 |
Cascade CM10 | boiler | 81 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin | 5 | 0 | 1 | 30 | 2 |
Cascade CM10 | boiler | 81 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | 5 | 0 | 1 | 32 | 2 |
Cascade CM10 | boiler | 81 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime | 5 | 0 | 1 | 34 | 2 |
Cascade CM10 | boiler | 81 | lastcode | last error code | string | | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | 5 | 0 | 1 | 36 | 28 |
Cascade CM10 | boiler | 81 | servicecode | service code | string | | False | sensor.boiler_service_code | sensor.boiler_servicecode | 5 | 0 | 1 | 64 | 2 |
Cascade CM10 | boiler | 81 | servicecodenumber | service code number | uint16 (>=0<=31999) | | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | 5 | 0 | 1 | 66 | 1 |
Cascade CM10 | boiler | 81 | maintenancemessage | maintenance message | string | | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | 5 | 0 | 1 | 67 | 2 |
Cascade CM10 | boiler | 81 | maintenance | maintenance scheduled | enum [off|time|date|manual] | | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | 5 | 0 | 1 | 69 | 1 |
Cascade CM10 | boiler | 81 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime | 5 | 0 | 1 | 70 | 1 |
Cascade CM10 | boiler | 81 | maintenancedate | next maintenance date | string | | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | 5 | 0 | 1 | 71 | 6 |
Cascade CM10 | boiler | 81 | emergencyops | emergency operation | boolean | | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | 5 | 0 | 1 | 77 | 1 |
Cascade CM10 | boiler | 81 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp | 5 | 0 | 1 | 78 | 1 |
Cascade CM10 | boiler | 81 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat | 5 | 0 | 1/10 | 91 | 2 |
Cascade CM10 | boiler | 81 | meter | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meter | 5 | 9 | 1/10 | 2 | 2 |
Cascade CM10 | boiler | 81 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat | 5 | 0 | 1/10 | 264 | 2 |
Cascade CM10 | boiler | 81 | gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeter | 5 | 9 | 1/10 | 69 | 2 |
Cascade CM10 | boiler | 81 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 | 5 | 0 | 1/10 | 266 | 2 |
Cascade CM10 | boiler | 81 | nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrg2 | 5 | 9 | 1/10 | 71 | 2 |
Cascade CM10 | boiler | 81 | tapactivated | turn on/off | boolean | | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | 5 | 9 | 1 | 28 | 1 |
Cascade CM10 | boiler | 81 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp | 5 | 9 | 1 | 29 | 1 |
Cascade CM10 | boiler | 81 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp | 5 | 9 | 1 | 30 | 1 |
Cascade CM10 | boiler | 81 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow | 5 | 9 | 1 | 31 | 1 |
Cascade CM10 | boiler | 81 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus | 5 | 9 | 1 | 32 | 1 |
Cascade CM10 | boiler | 81 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff | 5 | 9 | 1 | 33 | 1 |
Cascade CM10 | boiler | 81 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle | 5 | 9 | 1 | 34 | 1 |
Cascade CM10 | boiler | 81 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp | 5 | 9 | 1/10 | 35 | 1 |
Cascade CM10 | boiler | 81 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | 5 | 9 | 1 | 36 | 1 |
Cascade CM10 | boiler | 81 | comfort | comfort | enum [hot|eco|intelligent] | | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | 5 | 9 | 1 | 37 | 1 |
Cascade CM10 | boiler | 81 | comfort1 | comfort mode | enum [high comfort|eco] | | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | 5 | 9 | 1 | 38 | 1 |
Cascade CM10 | boiler | 81 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset | 5 | 9 | 1 | 39 | 1 |
Cascade CM10 | boiler | 81 | chargeoptimization | charge optimization | boolean | | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | 5 | 9 | 1 | 40 | 1 |
Cascade CM10 | boiler | 81 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower | 5 | 9 | 1 | 41 | 1 |
Cascade CM10 | boiler | 81 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp | 5 | 9 | 1 | 42 | 1 |
Cascade CM10 | boiler | 81 | circpump | circulation pump available | boolean | | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | 5 | 9 | 1 | 43 | 1 |
Cascade CM10 | boiler | 81 | chargetype | charging type | enum [chargepump|3-way valve] | | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | 5 | 9 | 1 | 44 | 1 |
Cascade CM10 | boiler | 81 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston | 5 | 9 | 1 | 45 | 1 |
Cascade CM10 | boiler | 81 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff | 5 | 9 | 1 | 46 | 1 |
Cascade CM10 | boiler | 81 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp | 5 | 9 | 1 | 47 | 1 |
Cascade CM10 | boiler | 81 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | 5 | 9 | 1 | 48 | 1 |
Cascade CM10 | boiler | 81 | circ | circulation active | boolean | | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | 5 | 9 | 1 | 49 | 1 |
Cascade CM10 | boiler | 81 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp | 5 | 9 | 1/10 | 50 | 1 |
Cascade CM10 | boiler | 81 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 | 5 | 9 | 1/10 | 51 | 1 |
Cascade CM10 | boiler | 81 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow | 5 | 9 | 1/10 | 52 | 1 |
Cascade CM10 | boiler | 81 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 | 5 | 9 | 1/10 | 53 | 1 |
Cascade CM10 | boiler | 81 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 | 5 | 9 | 1/10 | 54 | 1 |
Cascade CM10 | boiler | 81 | activated | activated | boolean | | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | 5 | 9 | 1 | 55 | 1 |
Cascade CM10 | boiler | 81 | onetime | one time charging | boolean | | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | 5 | 9 | 1 | 56 | 1 |
Cascade CM10 | boiler | 81 | disinfecting | disinfecting | boolean | | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | 5 | 9 | 1 | 57 | 1 |
Cascade CM10 | boiler | 81 | charging | charging | boolean | | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | 5 | 9 | 1 | 58 | 1 |
Cascade CM10 | boiler | 81 | recharging | recharging | boolean | | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | 5 | 9 | 1 | 59 | 1 |
Cascade CM10 | boiler | 81 | tempok | temperature ok | boolean | | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | 5 | 9 | 1 | 60 | 1 |
Cascade CM10 | boiler | 81 | active | active | boolean | | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | 5 | 9 | 1 | 61 | 1 |
Cascade CM10 | boiler | 81 | 3wayvalve | 3-way valve active | boolean | | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | 5 | 9 | 1 | 62 | 1 |
Cascade CM10 | boiler | 81 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp | 5 | 9 | 1/10 | 63 | 1 |
Cascade CM10 | boiler | 81 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp | 5 | 9 | 1/10 | 64 | 1 |
Cascade CM10 | boiler | 81 | starts | starts | uint24 (>=0<=16777213) | | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | 5 | 9 | 1 | 65 | 2 |
Cascade CM10 | boiler | 81 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm | 5 | 9 | 1 | 67 | 2 |
Cascade CM10 | boiler | 81 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower | 5 | 0 | 1 | 268 | 1 |
Cascade CM10 | boiler | 81 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal | 5 | 0 | 1/100 | 79 | 2 |
Cascade CM10 | boiler | 81 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat | 5 | 0 | 1/100 | 81 | 2 |
Cascade CM10 | boiler | 81 | nrg | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrg | 5 | 9 | 1/100 | 0 | 2 |
Logamax Plus GB022 | boiler | 84 | reset | reset | cmd [-|maintenance|error|history|message] | | True | sensor.boiler_reset | sensor.boiler_reset | 5 | 0 | 1 | 0 | 1 |
Logamax Plus GB022 | boiler | 84 | heatingoff | force heating off | boolean | | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | 5 | 0 | 1 | 1 | 1 |
Logamax Plus GB022 | boiler | 84 | heatingactive | heating active | boolean | | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | 5 | 0 | 1 | 2 | 1 |
Logamax Plus GB022 | boiler | 84 | tapwateractive | tapwater active | boolean | | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | 5 | 0 | 1 | 3 | 1 |
Logamax Plus GB022 | boiler | 84 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp | 5 | 0 | 1 | 4 | 1 |
Logamax Plus GB022 | boiler | 84 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod | 5 | 0 | 1 | 5 | 1 |
Logamax Plus GB022 | boiler | 84 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp | 5 | 0 | 1/10 | 6 | 1 |
Logamax Plus GB022 | boiler | 84 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp | 5 | 0 | 1/10 | 7 | 1 |
Logamax Plus GB022 | boiler | 84 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp | 5 | 0 | 1/10 | 8 | 1 |
Logamax Plus GB022 | boiler | 84 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp | 5 | 0 | 1/10 | 9 | 1 |
Logamax Plus GB022 | boiler | 84 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress | 5 | 0 | 1/10 | 10 | 1 |
Logamax Plus GB022 | boiler | 84 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp | 5 | 0 | 1/10 | 11 | 1 |
Logamax Plus GB022 | boiler | 84 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp | 5 | 0 | 1/10 | 12 | 1 |
Logamax Plus GB022 | boiler | 84 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp | 5 | 0 | 1/10 | 242 | 1 |
Logamax Plus GB022 | boiler | 84 | burngas | gas | boolean | | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | 5 | 0 | 1 | 243 | 1 |
Logamax Plus GB022 | boiler | 84 | burngas2 | gas stage 2 | boolean | | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | 5 | 0 | 1 | 244 | 1 |
Logamax Plus GB022 | boiler | 84 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr | 5 | 0 | 1/10 | 245 | 1 |
Logamax Plus GB022 | boiler | 84 | fanwork | fan | boolean | | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | 5 | 0 | 1 | 246 | 1 |
Logamax Plus GB022 | boiler | 84 | ignwork | ignition | boolean | | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | 5 | 0 | 1 | 247 | 1 |
Logamax Plus GB022 | boiler | 84 | oilpreheat | oil preheating | boolean | | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | 5 | 0 | 1 | 248 | 1 |
Logamax Plus GB022 | boiler | 84 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower | 5 | 0 | 1 | 249 | 1 |
Logamax Plus GB022 | boiler | 84 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower | 5 | 0 | 1 | 250 | 1 |
Logamax Plus GB022 | boiler | 84 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod | 5 | 0 | 1 | 251 | 1 |
Logamax Plus GB022 | boiler | 84 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow | 5 | 0 | 1 | 252 | 1 |
Logamax Plus GB022 | boiler | 84 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock | 5 | 0 | 1/10 | 253 | 1 |
Logamax Plus GB022 | boiler | 84 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston | 5 | 0 | 1 | 254 | 1 |
Logamax Plus GB022 | boiler | 84 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff | 5 | 0 | 1 | 255 | 1 |
Logamax Plus GB022 | boiler | 84 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston | 5 | 0 | 1 | 256 | 1 |
Logamax Plus GB022 | boiler | 84 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff | 5 | 0 | 1 | 257 | 1 |
Logamax Plus GB022 | boiler | 84 | curveon | heatingcurve on | boolean | | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | 5 | 0 | 1 | 258 | 1 |
Logamax Plus GB022 | boiler | 84 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase | 5 | 0 | 1 | 259 | 1 |
Logamax Plus GB022 | boiler | 84 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend | 5 | 0 | 1 | 260 | 1 |
Logamax Plus GB022 | boiler | 84 | summertemp | summer temperature | uint8 (>=0<=45) | C | True | number.boiler_summer_temperature | number.boiler_summertemp | 5 | 0 | 1 | 261 | 1 |
Logamax Plus GB022 | boiler | 84 | nofrostmode | nofrost mode | boolean | | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | 5 | 0 | 1 | 262 | 1 |
Logamax Plus GB022 | boiler | 84 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp | 5 | 0 | 1 | 263 | 1 |
Logamax Plus GB022 | boiler | 84 | heatingactivated | heating activated | boolean | | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | 5 | 0 | 1 | 13 | 1 |
Logamax Plus GB022 | boiler | 84 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp | 5 | 0 | 1 | 14 | 1 |
Logamax Plus GB022 | boiler | 84 | heatingpump | heating pump | boolean | | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | 5 | 0 | 1 | 15 | 1 |
Logamax Plus GB022 | boiler | 84 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax | 5 | 0 | 1 | 16 | 1 |
Logamax Plus GB022 | boiler | 84 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin | 5 | 0 | 1 | 17 | 1 |
Logamax Plus GB022 | boiler | 84 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | 5 | 0 | 1 | 18 | 1 |
Logamax Plus GB022 | boiler | 84 | pumpcharacter | boiler pump characteristic | enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] | | True | select.boiler_boiler_pump_characteristic | select.boiler_pumpcharacter | 5 | 0 | 1 | 19 | 1 |
Logamax Plus GB022 | boiler | 84 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay | 5 | 0 | 1 | 20 | 1 |
Logamax Plus GB022 | boiler | 84 | pumpontemp | pump logic temperature | uint8 (>=0<=60) | C | True | number.boiler_pump_logic_temperature | number.boiler_pumpontemp | 5 | 0 | 1 | 21 | 1 |
Logamax Plus GB022 | boiler | 84 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow | 5 | 0 | 1 | 22 | 1 |
Logamax Plus GB022 | boiler | 84 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow | 5 | 0 | 1 | 23 | 1 |
Logamax Plus GB022 | boiler | 84 | burnstarts | burner starts | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | 5 | 0 | 1 | 24 | 2 |
Logamax Plus GB022 | boiler | 84 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin | 5 | 0 | 1 | 26 | 2 |
Logamax Plus GB022 | boiler | 84 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin | 5 | 0 | 1 | 28 | 2 |
Logamax Plus GB022 | boiler | 84 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin | 5 | 0 | 1 | 30 | 2 |
Logamax Plus GB022 | boiler | 84 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | 5 | 0 | 1 | 32 | 2 |
Logamax Plus GB022 | boiler | 84 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime | 5 | 0 | 1 | 34 | 2 |
Logamax Plus GB022 | boiler | 84 | lastcode | last error code | string | | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | 5 | 0 | 1 | 36 | 28 |
Logamax Plus GB022 | boiler | 84 | servicecode | service code | string | | False | sensor.boiler_service_code | sensor.boiler_servicecode | 5 | 0 | 1 | 64 | 2 |
Logamax Plus GB022 | boiler | 84 | servicecodenumber | service code number | uint16 (>=0<=31999) | | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | 5 | 0 | 1 | 66 | 1 |
Logamax Plus GB022 | boiler | 84 | maintenancemessage | maintenance message | string | | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | 5 | 0 | 1 | 67 | 2 |
Logamax Plus GB022 | boiler | 84 | maintenance | maintenance scheduled | enum [off|time|date|manual] | | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | 5 | 0 | 1 | 69 | 1 |
Logamax Plus GB022 | boiler | 84 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime | 5 | 0 | 1 | 70 | 1 |
Logamax Plus GB022 | boiler | 84 | maintenancedate | next maintenance date | string | | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | 5 | 0 | 1 | 71 | 6 |
Logamax Plus GB022 | boiler | 84 | emergencyops | emergency operation | boolean | | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | 5 | 0 | 1 | 77 | 1 |
Logamax Plus GB022 | boiler | 84 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp | 5 | 0 | 1 | 78 | 1 |
Logamax Plus GB022 | boiler | 84 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat | 5 | 0 | 1/10 | 91 | 2 |
Logamax Plus GB022 | boiler | 84 | meter | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meter | 5 | 9 | 1/10 | 2 | 2 |
Logamax Plus GB022 | boiler | 84 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat | 5 | 0 | 1/10 | 264 | 2 |
Logamax Plus GB022 | boiler | 84 | gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeter | 5 | 9 | 1/10 | 69 | 2 |
Logamax Plus GB022 | boiler | 84 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 | 5 | 0 | 1/10 | 266 | 2 |
Logamax Plus GB022 | boiler | 84 | nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrg2 | 5 | 9 | 1/10 | 71 | 2 |
Logamax Plus GB022 | boiler | 84 | tapactivated | turn on/off | boolean | | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | 5 | 9 | 1 | 28 | 1 |
Logamax Plus GB022 | boiler | 84 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp | 5 | 9 | 1 | 29 | 1 |
Logamax Plus GB022 | boiler | 84 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp | 5 | 9 | 1 | 30 | 1 |
Logamax Plus GB022 | boiler | 84 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow | 5 | 9 | 1 | 31 | 1 |
Logamax Plus GB022 | boiler | 84 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus | 5 | 9 | 1 | 32 | 1 |
Logamax Plus GB022 | boiler | 84 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff | 5 | 9 | 1 | 33 | 1 |
Logamax Plus GB022 | boiler | 84 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle | 5 | 9 | 1 | 34 | 1 |
Logamax Plus GB022 | boiler | 84 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp | 5 | 9 | 1/10 | 35 | 1 |
Logamax Plus GB022 | boiler | 84 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | 5 | 9 | 1 | 36 | 1 |
Logamax Plus GB022 | boiler | 84 | comfort | comfort | enum [hot|eco|intelligent] | | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | 5 | 9 | 1 | 37 | 1 |
Logamax Plus GB022 | boiler | 84 | comfort1 | comfort mode | enum [high comfort|eco] | | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | 5 | 9 | 1 | 38 | 1 |
Logamax Plus GB022 | boiler | 84 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset | 5 | 9 | 1 | 39 | 1 |
Logamax Plus GB022 | boiler | 84 | chargeoptimization | charge optimization | boolean | | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | 5 | 9 | 1 | 40 | 1 |
Logamax Plus GB022 | boiler | 84 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower | 5 | 9 | 1 | 41 | 1 |
Logamax Plus GB022 | boiler | 84 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp | 5 | 9 | 1 | 42 | 1 |
Logamax Plus GB022 | boiler | 84 | circpump | circulation pump available | boolean | | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | 5 | 9 | 1 | 43 | 1 |
Logamax Plus GB022 | boiler | 84 | chargetype | charging type | enum [chargepump|3-way valve] | | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | 5 | 9 | 1 | 44 | 1 |
Logamax Plus GB022 | boiler | 84 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston | 5 | 9 | 1 | 45 | 1 |
Logamax Plus GB022 | boiler | 84 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff | 5 | 9 | 1 | 46 | 1 |
Logamax Plus GB022 | boiler | 84 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp | 5 | 9 | 1 | 47 | 1 |
Logamax Plus GB022 | boiler | 84 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | 5 | 9 | 1 | 48 | 1 |
Logamax Plus GB022 | boiler | 84 | circ | circulation active | boolean | | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | 5 | 9 | 1 | 49 | 1 |
Logamax Plus GB022 | boiler | 84 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp | 5 | 9 | 1/10 | 50 | 1 |
Logamax Plus GB022 | boiler | 84 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 | 5 | 9 | 1/10 | 51 | 1 |
Logamax Plus GB022 | boiler | 84 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow | 5 | 9 | 1/10 | 52 | 1 |
Logamax Plus GB022 | boiler | 84 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 | 5 | 9 | 1/10 | 53 | 1 |
Logamax Plus GB022 | boiler | 84 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 | 5 | 9 | 1/10 | 54 | 1 |
Logamax Plus GB022 | boiler | 84 | activated | activated | boolean | | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | 5 | 9 | 1 | 55 | 1 |
Logamax Plus GB022 | boiler | 84 | onetime | one time charging | boolean | | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | 5 | 9 | 1 | 56 | 1 |
Logamax Plus GB022 | boiler | 84 | disinfecting | disinfecting | boolean | | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | 5 | 9 | 1 | 57 | 1 |
Logamax Plus GB022 | boiler | 84 | charging | charging | boolean | | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | 5 | 9 | 1 | 58 | 1 |
Logamax Plus GB022 | boiler | 84 | recharging | recharging | boolean | | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | 5 | 9 | 1 | 59 | 1 |
Logamax Plus GB022 | boiler | 84 | tempok | temperature ok | boolean | | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | 5 | 9 | 1 | 60 | 1 |
Logamax Plus GB022 | boiler | 84 | active | active | boolean | | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | 5 | 9 | 1 | 61 | 1 |
Logamax Plus GB022 | boiler | 84 | 3wayvalve | 3-way valve active | boolean | | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | 5 | 9 | 1 | 62 | 1 |
Logamax Plus GB022 | boiler | 84 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp | 5 | 9 | 1/10 | 63 | 1 |
Logamax Plus GB022 | boiler | 84 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp | 5 | 9 | 1/10 | 64 | 1 |
Logamax Plus GB022 | boiler | 84 | starts | starts | uint24 (>=0<=16777213) | | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | 5 | 9 | 1 | 65 | 2 |
Logamax Plus GB022 | boiler | 84 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm | 5 | 9 | 1 | 67 | 2 |
Logamax Plus GB022 | boiler | 84 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower | 5 | 0 | 1 | 268 | 1 |
Logamax Plus GB022 | boiler | 84 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal | 5 | 0 | 1/100 | 79 | 2 |
Logamax Plus GB022 | boiler | 84 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat | 5 | 0 | 1/100 | 81 | 2 |
Logamax Plus GB022 | boiler | 84 | nrg | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrg | 5 | 9 | 1/100 | 0 | 2 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | reset | reset | cmd [-|maintenance|error|history|message] | | True | sensor.boiler_reset | sensor.boiler_reset | 5 | 0 | 1 | 0 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | heatingoff | force heating off | boolean | | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | 5 | 0 | 1 | 1 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | heatingactive | heating active | boolean | | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | 5 | 0 | 1 | 2 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | tapwateractive | tapwater active | boolean | | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | 5 | 0 | 1 | 3 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp | 5 | 0 | 1 | 4 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod | 5 | 0 | 1 | 5 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp | 5 | 0 | 1/10 | 6 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp | 5 | 0 | 1/10 | 7 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp | 5 | 0 | 1/10 | 8 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp | 5 | 0 | 1/10 | 9 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress | 5 | 0 | 1/10 | 10 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp | 5 | 0 | 1/10 | 11 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp | 5 | 0 | 1/10 | 12 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp | 5 | 0 | 1/10 | 242 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | burngas | gas | boolean | | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | 5 | 0 | 1 | 243 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | burngas2 | gas stage 2 | boolean | | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | 5 | 0 | 1 | 244 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr | 5 | 0 | 1/10 | 245 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | fanwork | fan | boolean | | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | 5 | 0 | 1 | 246 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | ignwork | ignition | boolean | | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | 5 | 0 | 1 | 247 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | oilpreheat | oil preheating | boolean | | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | 5 | 0 | 1 | 248 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower | 5 | 0 | 1 | 249 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower | 5 | 0 | 1 | 250 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod | 5 | 0 | 1 | 251 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow | 5 | 0 | 1 | 252 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock | 5 | 0 | 1/10 | 253 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston | 5 | 0 | 1 | 254 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff | 5 | 0 | 1 | 255 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston | 5 | 0 | 1 | 256 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff | 5 | 0 | 1 | 257 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | curveon | heatingcurve on | boolean | | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | 5 | 0 | 1 | 258 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase | 5 | 0 | 1 | 259 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend | 5 | 0 | 1 | 260 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | summertemp | summer temperature | uint8 (>=0<=45) | C | True | number.boiler_summer_temperature | number.boiler_summertemp | 5 | 0 | 1 | 261 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | nofrostmode | nofrost mode | boolean | | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | 5 | 0 | 1 | 262 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp | 5 | 0 | 1 | 263 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | heatingactivated | heating activated | boolean | | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | 5 | 0 | 1 | 13 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp | 5 | 0 | 1 | 14 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | heatingpump | heating pump | boolean | | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | 5 | 0 | 1 | 15 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax | 5 | 0 | 1 | 16 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin | 5 | 0 | 1 | 17 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | 5 | 0 | 1 | 18 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | pumpcharacter | boiler pump characteristic | enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] | | True | select.boiler_boiler_pump_characteristic | select.boiler_pumpcharacter | 5 | 0 | 1 | 19 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay | 5 | 0 | 1 | 20 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | pumpontemp | pump logic temperature | uint8 (>=0<=60) | C | True | number.boiler_pump_logic_temperature | number.boiler_pumpontemp | 5 | 0 | 1 | 21 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow | 5 | 0 | 1 | 22 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow | 5 | 0 | 1 | 23 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | burnstarts | burner starts | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | 5 | 0 | 1 | 24 | 2 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin | 5 | 0 | 1 | 26 | 2 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin | 5 | 0 | 1 | 28 | 2 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin | 5 | 0 | 1 | 30 | 2 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | 5 | 0 | 1 | 32 | 2 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime | 5 | 0 | 1 | 34 | 2 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | lastcode | last error code | string | | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | 5 | 0 | 1 | 36 | 28 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | servicecode | service code | string | | False | sensor.boiler_service_code | sensor.boiler_servicecode | 5 | 0 | 1 | 64 | 2 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | servicecodenumber | service code number | uint16 (>=0<=31999) | | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | 5 | 0 | 1 | 66 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | maintenancemessage | maintenance message | string | | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | 5 | 0 | 1 | 67 | 2 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | maintenance | maintenance scheduled | enum [off|time|date|manual] | | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | 5 | 0 | 1 | 69 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime | 5 | 0 | 1 | 70 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | maintenancedate | next maintenance date | string | | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | 5 | 0 | 1 | 71 | 6 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | emergencyops | emergency operation | boolean | | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | 5 | 0 | 1 | 77 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp | 5 | 0 | 1 | 78 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat | 5 | 0 | 1/10 | 91 | 2 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | meter | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meter | 5 | 9 | 1/10 | 2 | 2 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat | 5 | 0 | 1/10 | 264 | 2 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeter | 5 | 9 | 1/10 | 69 | 2 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 | 5 | 0 | 1/10 | 266 | 2 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrg2 | 5 | 9 | 1/10 | 71 | 2 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | tapactivated | turn on/off | boolean | | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | 5 | 9 | 1 | 28 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp | 5 | 9 | 1 | 29 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp | 5 | 9 | 1 | 30 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow | 5 | 9 | 1 | 31 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus | 5 | 9 | 1 | 32 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff | 5 | 9 | 1 | 33 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle | 5 | 9 | 1 | 34 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp | 5 | 9 | 1/10 | 35 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | 5 | 9 | 1 | 36 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | comfort | comfort | enum [hot|eco|intelligent] | | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | 5 | 9 | 1 | 37 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | comfort1 | comfort mode | enum [high comfort|eco] | | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | 5 | 9 | 1 | 38 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset | 5 | 9 | 1 | 39 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | chargeoptimization | charge optimization | boolean | | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | 5 | 9 | 1 | 40 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower | 5 | 9 | 1 | 41 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp | 5 | 9 | 1 | 42 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | circpump | circulation pump available | boolean | | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | 5 | 9 | 1 | 43 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | chargetype | charging type | enum [chargepump|3-way valve] | | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | 5 | 9 | 1 | 44 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston | 5 | 9 | 1 | 45 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff | 5 | 9 | 1 | 46 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp | 5 | 9 | 1 | 47 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | 5 | 9 | 1 | 48 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | circ | circulation active | boolean | | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | 5 | 9 | 1 | 49 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp | 5 | 9 | 1/10 | 50 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 | 5 | 9 | 1/10 | 51 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow | 5 | 9 | 1/10 | 52 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 | 5 | 9 | 1/10 | 53 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 | 5 | 9 | 1/10 | 54 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | activated | activated | boolean | | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | 5 | 9 | 1 | 55 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | onetime | one time charging | boolean | | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | 5 | 9 | 1 | 56 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | disinfecting | disinfecting | boolean | | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | 5 | 9 | 1 | 57 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | charging | charging | boolean | | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | 5 | 9 | 1 | 58 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | recharging | recharging | boolean | | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | 5 | 9 | 1 | 59 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | tempok | temperature ok | boolean | | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | 5 | 9 | 1 | 60 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | active | active | boolean | | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | 5 | 9 | 1 | 61 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | 3wayvalve | 3-way valve active | boolean | | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | 5 | 9 | 1 | 62 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp | 5 | 9 | 1/10 | 63 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp | 5 | 9 | 1/10 | 64 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | starts | starts | uint24 (>=0<=16777213) | | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | 5 | 9 | 1 | 65 | 2 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm | 5 | 9 | 1 | 67 | 2 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower | 5 | 0 | 1 | 268 | 1 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal | 5 | 0 | 1/100 | 79 | 2 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat | 5 | 0 | 1/100 | 81 | 2 |
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 | boiler | 95 | nrg | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrg | 5 | 9 | 1/100 | 0 | 2 |
Topline, GB162 | boiler | 115 | reset | reset | cmd [-|maintenance|error|history|message] | | True | sensor.boiler_reset | sensor.boiler_reset | 5 | 0 | 1 | 0 | 1 |
Topline, GB162 | boiler | 115 | heatingoff | force heating off | boolean | | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | 5 | 0 | 1 | 1 | 1 |
Topline, GB162 | boiler | 115 | heatingactive | heating active | boolean | | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | 5 | 0 | 1 | 2 | 1 |
Topline, GB162 | boiler | 115 | tapwateractive | tapwater active | boolean | | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | 5 | 0 | 1 | 3 | 1 |
Topline, GB162 | boiler | 115 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp | 5 | 0 | 1 | 4 | 1 |
Topline, GB162 | boiler | 115 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod | 5 | 0 | 1 | 5 | 1 |
Topline, GB162 | boiler | 115 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp | 5 | 0 | 1/10 | 6 | 1 |
Topline, GB162 | boiler | 115 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp | 5 | 0 | 1/10 | 7 | 1 |
Topline, GB162 | boiler | 115 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp | 5 | 0 | 1/10 | 8 | 1 |
Topline, GB162 | boiler | 115 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp | 5 | 0 | 1/10 | 9 | 1 |
Topline, GB162 | boiler | 115 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress | 5 | 0 | 1/10 | 10 | 1 |
Topline, GB162 | boiler | 115 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp | 5 | 0 | 1/10 | 11 | 1 |
Topline, GB162 | boiler | 115 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp | 5 | 0 | 1/10 | 12 | 1 |
Topline, GB162 | boiler | 115 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp | 5 | 0 | 1/10 | 242 | 1 |
Topline, GB162 | boiler | 115 | burngas | gas | boolean | | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | 5 | 0 | 1 | 243 | 1 |
Topline, GB162 | boiler | 115 | burngas2 | gas stage 2 | boolean | | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | 5 | 0 | 1 | 244 | 1 |
Topline, GB162 | boiler | 115 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr | 5 | 0 | 1/10 | 245 | 1 |
Topline, GB162 | boiler | 115 | fanwork | fan | boolean | | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | 5 | 0 | 1 | 246 | 1 |
Topline, GB162 | boiler | 115 | ignwork | ignition | boolean | | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | 5 | 0 | 1 | 247 | 1 |
Topline, GB162 | boiler | 115 | oilpreheat | oil preheating | boolean | | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | 5 | 0 | 1 | 248 | 1 |
Topline, GB162 | boiler | 115 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower | 5 | 0 | 1 | 249 | 1 |
Topline, GB162 | boiler | 115 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower | 5 | 0 | 1 | 250 | 1 |
Topline, GB162 | boiler | 115 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod | 5 | 0 | 1 | 251 | 1 |
Topline, GB162 | boiler | 115 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow | 5 | 0 | 1 | 252 | 1 |
Topline, GB162 | boiler | 115 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock | 5 | 0 | 1/10 | 253 | 1 |
Topline, GB162 | boiler | 115 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston | 5 | 0 | 1 | 254 | 1 |
Topline, GB162 | boiler | 115 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff | 5 | 0 | 1 | 255 | 1 |
Topline, GB162 | boiler | 115 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston | 5 | 0 | 1 | 256 | 1 |
Topline, GB162 | boiler | 115 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff | 5 | 0 | 1 | 257 | 1 |
Topline, GB162 | boiler | 115 | curveon | heatingcurve on | boolean | | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | 5 | 0 | 1 | 258 | 1 |
Topline, GB162 | boiler | 115 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase | 5 | 0 | 1 | 259 | 1 |
Topline, GB162 | boiler | 115 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend | 5 | 0 | 1 | 260 | 1 |
Topline, GB162 | boiler | 115 | summertemp | summer temperature | uint8 (>=0<=45) | C | True | number.boiler_summer_temperature | number.boiler_summertemp | 5 | 0 | 1 | 261 | 1 |
Topline, GB162 | boiler | 115 | nofrostmode | nofrost mode | boolean | | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | 5 | 0 | 1 | 262 | 1 |
Topline, GB162 | boiler | 115 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp | 5 | 0 | 1 | 263 | 1 |
Topline, GB162 | boiler | 115 | heatingactivated | heating activated | boolean | | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | 5 | 0 | 1 | 13 | 1 |
Topline, GB162 | boiler | 115 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp | 5 | 0 | 1 | 14 | 1 |
Topline, GB162 | boiler | 115 | heatingpump | heating pump | boolean | | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | 5 | 0 | 1 | 15 | 1 |
Topline, GB162 | boiler | 115 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax | 5 | 0 | 1 | 16 | 1 |
Topline, GB162 | boiler | 115 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin | 5 | 0 | 1 | 17 | 1 |
Topline, GB162 | boiler | 115 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | 5 | 0 | 1 | 18 | 1 |
Topline, GB162 | boiler | 115 | pumpcharacter | boiler pump characteristic | enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] | | True | select.boiler_boiler_pump_characteristic | select.boiler_pumpcharacter | 5 | 0 | 1 | 19 | 1 |
Topline, GB162 | boiler | 115 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay | 5 | 0 | 1 | 20 | 1 |
Topline, GB162 | boiler | 115 | pumpontemp | pump logic temperature | uint8 (>=0<=60) | C | True | number.boiler_pump_logic_temperature | number.boiler_pumpontemp | 5 | 0 | 1 | 21 | 1 |
Topline, GB162 | boiler | 115 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow | 5 | 0 | 1 | 22 | 1 |
Topline, GB162 | boiler | 115 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow | 5 | 0 | 1 | 23 | 1 |
Topline, GB162 | boiler | 115 | burnstarts | burner starts | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | 5 | 0 | 1 | 24 | 2 |
Topline, GB162 | boiler | 115 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin | 5 | 0 | 1 | 26 | 2 |
Topline, GB162 | boiler | 115 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin | 5 | 0 | 1 | 28 | 2 |
Topline, GB162 | boiler | 115 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin | 5 | 0 | 1 | 30 | 2 |
Topline, GB162 | boiler | 115 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | 5 | 0 | 1 | 32 | 2 |
Topline, GB162 | boiler | 115 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime | 5 | 0 | 1 | 34 | 2 |
Topline, GB162 | boiler | 115 | lastcode | last error code | string | | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | 5 | 0 | 1 | 36 | 28 |
Topline, GB162 | boiler | 115 | servicecode | service code | string | | False | sensor.boiler_service_code | sensor.boiler_servicecode | 5 | 0 | 1 | 64 | 2 |
Topline, GB162 | boiler | 115 | servicecodenumber | service code number | uint16 (>=0<=31999) | | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | 5 | 0 | 1 | 66 | 1 |
Topline, GB162 | boiler | 115 | maintenancemessage | maintenance message | string | | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | 5 | 0 | 1 | 67 | 2 |
Topline, GB162 | boiler | 115 | maintenance | maintenance scheduled | enum [off|time|date|manual] | | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | 5 | 0 | 1 | 69 | 1 |
Topline, GB162 | boiler | 115 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime | 5 | 0 | 1 | 70 | 1 |
Topline, GB162 | boiler | 115 | maintenancedate | next maintenance date | string | | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | 5 | 0 | 1 | 71 | 6 |
Topline, GB162 | boiler | 115 | emergencyops | emergency operation | boolean | | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | 5 | 0 | 1 | 77 | 1 |
Topline, GB162 | boiler | 115 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp | 5 | 0 | 1 | 78 | 1 |
Topline, GB162 | boiler | 115 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat | 5 | 0 | 1/10 | 91 | 2 |
Topline, GB162 | boiler | 115 | meter | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meter | 5 | 9 | 1/10 | 2 | 2 |
Topline, GB162 | boiler | 115 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat | 5 | 0 | 1/10 | 264 | 2 |
Topline, GB162 | boiler | 115 | gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeter | 5 | 9 | 1/10 | 69 | 2 |
Topline, GB162 | boiler | 115 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 | 5 | 0 | 1/10 | 266 | 2 |
Topline, GB162 | boiler | 115 | nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrg2 | 5 | 9 | 1/10 | 71 | 2 |
Topline, GB162 | boiler | 115 | tapactivated | turn on/off | boolean | | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | 5 | 9 | 1 | 28 | 1 |
Topline, GB162 | boiler | 115 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp | 5 | 9 | 1 | 29 | 1 |
Topline, GB162 | boiler | 115 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp | 5 | 9 | 1 | 30 | 1 |
Topline, GB162 | boiler | 115 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow | 5 | 9 | 1 | 31 | 1 |
Topline, GB162 | boiler | 115 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus | 5 | 9 | 1 | 32 | 1 |
Topline, GB162 | boiler | 115 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff | 5 | 9 | 1 | 33 | 1 |
Topline, GB162 | boiler | 115 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle | 5 | 9 | 1 | 34 | 1 |
Topline, GB162 | boiler | 115 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp | 5 | 9 | 1/10 | 35 | 1 |
Topline, GB162 | boiler | 115 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | 5 | 9 | 1 | 36 | 1 |
Topline, GB162 | boiler | 115 | comfort | comfort | enum [hot|eco|intelligent] | | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | 5 | 9 | 1 | 37 | 1 |
Topline, GB162 | boiler | 115 | comfort1 | comfort mode | enum [high comfort|eco] | | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | 5 | 9 | 1 | 38 | 1 |
Topline, GB162 | boiler | 115 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset | 5 | 9 | 1 | 39 | 1 |
Topline, GB162 | boiler | 115 | chargeoptimization | charge optimization | boolean | | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | 5 | 9 | 1 | 40 | 1 |
Topline, GB162 | boiler | 115 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower | 5 | 9 | 1 | 41 | 1 |
Topline, GB162 | boiler | 115 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp | 5 | 9 | 1 | 42 | 1 |
Topline, GB162 | boiler | 115 | circpump | circulation pump available | boolean | | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | 5 | 9 | 1 | 43 | 1 |
Topline, GB162 | boiler | 115 | chargetype | charging type | enum [chargepump|3-way valve] | | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | 5 | 9 | 1 | 44 | 1 |
Topline, GB162 | boiler | 115 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston | 5 | 9 | 1 | 45 | 1 |
Topline, GB162 | boiler | 115 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff | 5 | 9 | 1 | 46 | 1 |
Topline, GB162 | boiler | 115 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp | 5 | 9 | 1 | 47 | 1 |
Topline, GB162 | boiler | 115 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | 5 | 9 | 1 | 48 | 1 |
Topline, GB162 | boiler | 115 | circ | circulation active | boolean | | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | 5 | 9 | 1 | 49 | 1 |
Topline, GB162 | boiler | 115 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp | 5 | 9 | 1/10 | 50 | 1 |
Topline, GB162 | boiler | 115 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 | 5 | 9 | 1/10 | 51 | 1 |
Topline, GB162 | boiler | 115 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow | 5 | 9 | 1/10 | 52 | 1 |
Topline, GB162 | boiler | 115 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 | 5 | 9 | 1/10 | 53 | 1 |
Topline, GB162 | boiler | 115 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 | 5 | 9 | 1/10 | 54 | 1 |
Topline, GB162 | boiler | 115 | activated | activated | boolean | | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | 5 | 9 | 1 | 55 | 1 |
Topline, GB162 | boiler | 115 | onetime | one time charging | boolean | | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | 5 | 9 | 1 | 56 | 1 |
Topline, GB162 | boiler | 115 | disinfecting | disinfecting | boolean | | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | 5 | 9 | 1 | 57 | 1 |
Topline, GB162 | boiler | 115 | charging | charging | boolean | | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | 5 | 9 | 1 | 58 | 1 |
Topline, GB162 | boiler | 115 | recharging | recharging | boolean | | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | 5 | 9 | 1 | 59 | 1 |
Topline, GB162 | boiler | 115 | tempok | temperature ok | boolean | | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | 5 | 9 | 1 | 60 | 1 |
Topline, GB162 | boiler | 115 | active | active | boolean | | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | 5 | 9 | 1 | 61 | 1 |
Topline, GB162 | boiler | 115 | 3wayvalve | 3-way valve active | boolean | | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | 5 | 9 | 1 | 62 | 1 |
Topline, GB162 | boiler | 115 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp | 5 | 9 | 1/10 | 63 | 1 |
Topline, GB162 | boiler | 115 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp | 5 | 9 | 1/10 | 64 | 1 |
Topline, GB162 | boiler | 115 | starts | starts | uint24 (>=0<=16777213) | | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | 5 | 9 | 1 | 65 | 2 |
Topline, GB162 | boiler | 115 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm | 5 | 9 | 1 | 67 | 2 |
Topline, GB162 | boiler | 115 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower | 5 | 0 | 1 | 268 | 1 |
Topline, GB162 | boiler | 115 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal | 5 | 0 | 1/100 | 79 | 2 |
Topline, GB162 | boiler | 115 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat | 5 | 0 | 1/100 | 81 | 2 |
Topline, GB162 | boiler | 115 | nrg | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrg | 5 | 9 | 1/100 | 0 | 2 |
Cascade MCM10 | boiler | 121 | reset | reset | cmd [-|maintenance|error|history|message] | | True | sensor.boiler_reset | sensor.boiler_reset | 5 | 0 | 1 | 0 | 1 |
Cascade MCM10 | boiler | 121 | heatingoff | force heating off | boolean | | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | 5 | 0 | 1 | 1 | 1 |
Cascade MCM10 | boiler | 121 | heatingactive | heating active | boolean | | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | 5 | 0 | 1 | 2 | 1 |
Cascade MCM10 | boiler | 121 | tapwateractive | tapwater active | boolean | | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | 5 | 0 | 1 | 3 | 1 |
Cascade MCM10 | boiler | 121 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp | 5 | 0 | 1 | 4 | 1 |
Cascade MCM10 | boiler | 121 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod | 5 | 0 | 1 | 5 | 1 |
Cascade MCM10 | boiler | 121 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp | 5 | 0 | 1/10 | 6 | 1 |
Cascade MCM10 | boiler | 121 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp | 5 | 0 | 1/10 | 7 | 1 |
Cascade MCM10 | boiler | 121 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp | 5 | 0 | 1/10 | 8 | 1 |
Cascade MCM10 | boiler | 121 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp | 5 | 0 | 1/10 | 9 | 1 |
Cascade MCM10 | boiler | 121 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress | 5 | 0 | 1/10 | 10 | 1 |
Cascade MCM10 | boiler | 121 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp | 5 | 0 | 1/10 | 11 | 1 |
Cascade MCM10 | boiler | 121 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp | 5 | 0 | 1/10 | 12 | 1 |
Cascade MCM10 | boiler | 121 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp | 5 | 0 | 1/10 | 242 | 1 |
Cascade MCM10 | boiler | 121 | burngas | gas | boolean | | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | 5 | 0 | 1 | 243 | 1 |
Cascade MCM10 | boiler | 121 | burngas2 | gas stage 2 | boolean | | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | 5 | 0 | 1 | 244 | 1 |
Cascade MCM10 | boiler | 121 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr | 5 | 0 | 1/10 | 245 | 1 |
Cascade MCM10 | boiler | 121 | fanwork | fan | boolean | | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | 5 | 0 | 1 | 246 | 1 |
Cascade MCM10 | boiler | 121 | ignwork | ignition | boolean | | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | 5 | 0 | 1 | 247 | 1 |
Cascade MCM10 | boiler | 121 | oilpreheat | oil preheating | boolean | | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | 5 | 0 | 1 | 248 | 1 |
Cascade MCM10 | boiler | 121 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower | 5 | 0 | 1 | 249 | 1 |
Cascade MCM10 | boiler | 121 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower | 5 | 0 | 1 | 250 | 1 |
Cascade MCM10 | boiler | 121 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod | 5 | 0 | 1 | 251 | 1 |
Cascade MCM10 | boiler | 121 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow | 5 | 0 | 1 | 252 | 1 |
Cascade MCM10 | boiler | 121 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock | 5 | 0 | 1/10 | 253 | 1 |
Cascade MCM10 | boiler | 121 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston | 5 | 0 | 1 | 254 | 1 |
Cascade MCM10 | boiler | 121 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff | 5 | 0 | 1 | 255 | 1 |
Cascade MCM10 | boiler | 121 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston | 5 | 0 | 1 | 256 | 1 |
Cascade MCM10 | boiler | 121 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff | 5 | 0 | 1 | 257 | 1 |
Cascade MCM10 | boiler | 121 | curveon | heatingcurve on | boolean | | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | 5 | 0 | 1 | 258 | 1 |
Cascade MCM10 | boiler | 121 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase | 5 | 0 | 1 | 259 | 1 |
Cascade MCM10 | boiler | 121 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend | 5 | 0 | 1 | 260 | 1 |
Cascade MCM10 | boiler | 121 | summertemp | summer temperature | uint8 (>=0<=45) | C | True | number.boiler_summer_temperature | number.boiler_summertemp | 5 | 0 | 1 | 261 | 1 |
Cascade MCM10 | boiler | 121 | nofrostmode | nofrost mode | boolean | | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | 5 | 0 | 1 | 262 | 1 |
Cascade MCM10 | boiler | 121 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp | 5 | 0 | 1 | 263 | 1 |
Cascade MCM10 | boiler | 121 | heatingactivated | heating activated | boolean | | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | 5 | 0 | 1 | 13 | 1 |
Cascade MCM10 | boiler | 121 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp | 5 | 0 | 1 | 14 | 1 |
Cascade MCM10 | boiler | 121 | heatingpump | heating pump | boolean | | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | 5 | 0 | 1 | 15 | 1 |
Cascade MCM10 | boiler | 121 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax | 5 | 0 | 1 | 16 | 1 |
Cascade MCM10 | boiler | 121 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin | 5 | 0 | 1 | 17 | 1 |
Cascade MCM10 | boiler | 121 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | 5 | 0 | 1 | 18 | 1 |
Cascade MCM10 | boiler | 121 | pumpcharacter | boiler pump characteristic | enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] | | True | select.boiler_boiler_pump_characteristic | select.boiler_pumpcharacter | 5 | 0 | 1 | 19 | 1 |
Cascade MCM10 | boiler | 121 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay | 5 | 0 | 1 | 20 | 1 |
Cascade MCM10 | boiler | 121 | pumpontemp | pump logic temperature | uint8 (>=0<=60) | C | True | number.boiler_pump_logic_temperature | number.boiler_pumpontemp | 5 | 0 | 1 | 21 | 1 |
Cascade MCM10 | boiler | 121 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow | 5 | 0 | 1 | 22 | 1 |
Cascade MCM10 | boiler | 121 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow | 5 | 0 | 1 | 23 | 1 |
Cascade MCM10 | boiler | 121 | burnstarts | burner starts | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | 5 | 0 | 1 | 24 | 2 |
Cascade MCM10 | boiler | 121 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin | 5 | 0 | 1 | 26 | 2 |
Cascade MCM10 | boiler | 121 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin | 5 | 0 | 1 | 28 | 2 |
Cascade MCM10 | boiler | 121 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin | 5 | 0 | 1 | 30 | 2 |
Cascade MCM10 | boiler | 121 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | 5 | 0 | 1 | 32 | 2 |
Cascade MCM10 | boiler | 121 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime | 5 | 0 | 1 | 34 | 2 |
Cascade MCM10 | boiler | 121 | lastcode | last error code | string | | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | 5 | 0 | 1 | 36 | 28 |
Cascade MCM10 | boiler | 121 | servicecode | service code | string | | False | sensor.boiler_service_code | sensor.boiler_servicecode | 5 | 0 | 1 | 64 | 2 |
Cascade MCM10 | boiler | 121 | servicecodenumber | service code number | uint16 (>=0<=31999) | | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | 5 | 0 | 1 | 66 | 1 |
Cascade MCM10 | boiler | 121 | maintenancemessage | maintenance message | string | | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | 5 | 0 | 1 | 67 | 2 |
Cascade MCM10 | boiler | 121 | maintenance | maintenance scheduled | enum [off|time|date|manual] | | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | 5 | 0 | 1 | 69 | 1 |
Cascade MCM10 | boiler | 121 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime | 5 | 0 | 1 | 70 | 1 |
Cascade MCM10 | boiler | 121 | maintenancedate | next maintenance date | string | | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | 5 | 0 | 1 | 71 | 6 |
Cascade MCM10 | boiler | 121 | emergencyops | emergency operation | boolean | | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | 5 | 0 | 1 | 77 | 1 |
Cascade MCM10 | boiler | 121 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp | 5 | 0 | 1 | 78 | 1 |
Cascade MCM10 | boiler | 121 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat | 5 | 0 | 1/10 | 91 | 2 |
Cascade MCM10 | boiler | 121 | meter | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meter | 5 | 9 | 1/10 | 2 | 2 |
Cascade MCM10 | boiler | 121 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat | 5 | 0 | 1/10 | 264 | 2 |
Cascade MCM10 | boiler | 121 | gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeter | 5 | 9 | 1/10 | 69 | 2 |
Cascade MCM10 | boiler | 121 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 | 5 | 0 | 1/10 | 266 | 2 |
Cascade MCM10 | boiler | 121 | nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrg2 | 5 | 9 | 1/10 | 71 | 2 |
Cascade MCM10 | boiler | 121 | tapactivated | turn on/off | boolean | | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | 5 | 9 | 1 | 28 | 1 |
Cascade MCM10 | boiler | 121 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp | 5 | 9 | 1 | 29 | 1 |
Cascade MCM10 | boiler | 121 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp | 5 | 9 | 1 | 30 | 1 |
Cascade MCM10 | boiler | 121 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow | 5 | 9 | 1 | 31 | 1 |
Cascade MCM10 | boiler | 121 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus | 5 | 9 | 1 | 32 | 1 |
Cascade MCM10 | boiler | 121 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff | 5 | 9 | 1 | 33 | 1 |
Cascade MCM10 | boiler | 121 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle | 5 | 9 | 1 | 34 | 1 |
Cascade MCM10 | boiler | 121 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp | 5 | 9 | 1/10 | 35 | 1 |
Cascade MCM10 | boiler | 121 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | 5 | 9 | 1 | 36 | 1 |
Cascade MCM10 | boiler | 121 | comfort | comfort | enum [hot|eco|intelligent] | | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | 5 | 9 | 1 | 37 | 1 |
Cascade MCM10 | boiler | 121 | comfort1 | comfort mode | enum [high comfort|eco] | | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | 5 | 9 | 1 | 38 | 1 |
Cascade MCM10 | boiler | 121 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset | 5 | 9 | 1 | 39 | 1 |
Cascade MCM10 | boiler | 121 | chargeoptimization | charge optimization | boolean | | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | 5 | 9 | 1 | 40 | 1 |
Cascade MCM10 | boiler | 121 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower | 5 | 9 | 1 | 41 | 1 |
Cascade MCM10 | boiler | 121 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp | 5 | 9 | 1 | 42 | 1 |
Cascade MCM10 | boiler | 121 | circpump | circulation pump available | boolean | | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | 5 | 9 | 1 | 43 | 1 |
Cascade MCM10 | boiler | 121 | chargetype | charging type | enum [chargepump|3-way valve] | | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | 5 | 9 | 1 | 44 | 1 |
Cascade MCM10 | boiler | 121 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston | 5 | 9 | 1 | 45 | 1 |
Cascade MCM10 | boiler | 121 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff | 5 | 9 | 1 | 46 | 1 |
Cascade MCM10 | boiler | 121 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp | 5 | 9 | 1 | 47 | 1 |
Cascade MCM10 | boiler | 121 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | 5 | 9 | 1 | 48 | 1 |
Cascade MCM10 | boiler | 121 | circ | circulation active | boolean | | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | 5 | 9 | 1 | 49 | 1 |
Cascade MCM10 | boiler | 121 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp | 5 | 9 | 1/10 | 50 | 1 |
Cascade MCM10 | boiler | 121 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 | 5 | 9 | 1/10 | 51 | 1 |
Cascade MCM10 | boiler | 121 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow | 5 | 9 | 1/10 | 52 | 1 |
Cascade MCM10 | boiler | 121 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 | 5 | 9 | 1/10 | 53 | 1 |
Cascade MCM10 | boiler | 121 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 | 5 | 9 | 1/10 | 54 | 1 |
Cascade MCM10 | boiler | 121 | activated | activated | boolean | | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | 5 | 9 | 1 | 55 | 1 |
Cascade MCM10 | boiler | 121 | onetime | one time charging | boolean | | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | 5 | 9 | 1 | 56 | 1 |
Cascade MCM10 | boiler | 121 | disinfecting | disinfecting | boolean | | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | 5 | 9 | 1 | 57 | 1 |
Cascade MCM10 | boiler | 121 | charging | charging | boolean | | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | 5 | 9 | 1 | 58 | 1 |
Cascade MCM10 | boiler | 121 | recharging | recharging | boolean | | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | 5 | 9 | 1 | 59 | 1 |
Cascade MCM10 | boiler | 121 | tempok | temperature ok | boolean | | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | 5 | 9 | 1 | 60 | 1 |
Cascade MCM10 | boiler | 121 | active | active | boolean | | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | 5 | 9 | 1 | 61 | 1 |
Cascade MCM10 | boiler | 121 | 3wayvalve | 3-way valve active | boolean | | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | 5 | 9 | 1 | 62 | 1 |
Cascade MCM10 | boiler | 121 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp | 5 | 9 | 1/10 | 63 | 1 |
Cascade MCM10 | boiler | 121 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp | 5 | 9 | 1/10 | 64 | 1 |
Cascade MCM10 | boiler | 121 | starts | starts | uint24 (>=0<=16777213) | | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | 5 | 9 | 1 | 65 | 2 |
Cascade MCM10 | boiler | 121 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm | 5 | 9 | 1 | 67 | 2 |
Cascade MCM10 | boiler | 121 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower | 5 | 0 | 1 | 268 | 1 |
Cascade MCM10 | boiler | 121 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal | 5 | 0 | 1/100 | 79 | 2 |
Cascade MCM10 | boiler | 121 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat | 5 | 0 | 1/100 | 81 | 2 |
Cascade MCM10 | boiler | 121 | nrg | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrg | 5 | 9 | 1/100 | 0 | 2 |
Proline | boiler | 122 | reset | reset | cmd [-|maintenance|error|history|message] | | True | sensor.boiler_reset | sensor.boiler_reset | 5 | 0 | 1 | 0 | 1 |
Proline | boiler | 122 | heatingoff | force heating off | boolean | | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | 5 | 0 | 1 | 1 | 1 |
Proline | boiler | 122 | heatingactive | heating active | boolean | | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | 5 | 0 | 1 | 2 | 1 |
Proline | boiler | 122 | tapwateractive | tapwater active | boolean | | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | 5 | 0 | 1 | 3 | 1 |
Proline | boiler | 122 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp | 5 | 0 | 1 | 4 | 1 |
Proline | boiler | 122 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod | 5 | 0 | 1 | 5 | 1 |
Proline | boiler | 122 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp | 5 | 0 | 1/10 | 6 | 1 |
Proline | boiler | 122 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp | 5 | 0 | 1/10 | 7 | 1 |
Proline | boiler | 122 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp | 5 | 0 | 1/10 | 8 | 1 |
Proline | boiler | 122 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp | 5 | 0 | 1/10 | 9 | 1 |
Proline | boiler | 122 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress | 5 | 0 | 1/10 | 10 | 1 |
Proline | boiler | 122 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp | 5 | 0 | 1/10 | 11 | 1 |
Proline | boiler | 122 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp | 5 | 0 | 1/10 | 12 | 1 |
Proline | boiler | 122 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp | 5 | 0 | 1/10 | 242 | 1 |
Proline | boiler | 122 | burngas | gas | boolean | | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | 5 | 0 | 1 | 243 | 1 |
Proline | boiler | 122 | burngas2 | gas stage 2 | boolean | | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | 5 | 0 | 1 | 244 | 1 |
Proline | boiler | 122 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr | 5 | 0 | 1/10 | 245 | 1 |
Proline | boiler | 122 | fanwork | fan | boolean | | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | 5 | 0 | 1 | 246 | 1 |
Proline | boiler | 122 | ignwork | ignition | boolean | | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | 5 | 0 | 1 | 247 | 1 |
Proline | boiler | 122 | oilpreheat | oil preheating | boolean | | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | 5 | 0 | 1 | 248 | 1 |
Proline | boiler | 122 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower | 5 | 0 | 1 | 249 | 1 |
Proline | boiler | 122 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower | 5 | 0 | 1 | 250 | 1 |
Proline | boiler | 122 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod | 5 | 0 | 1 | 251 | 1 |
Proline | boiler | 122 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow | 5 | 0 | 1 | 252 | 1 |
Proline | boiler | 122 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock | 5 | 0 | 1/10 | 253 | 1 |
Proline | boiler | 122 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston | 5 | 0 | 1 | 254 | 1 |
Proline | boiler | 122 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff | 5 | 0 | 1 | 255 | 1 |
Proline | boiler | 122 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston | 5 | 0 | 1 | 256 | 1 |
Proline | boiler | 122 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff | 5 | 0 | 1 | 257 | 1 |
Proline | boiler | 122 | curveon | heatingcurve on | boolean | | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | 5 | 0 | 1 | 258 | 1 |
Proline | boiler | 122 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase | 5 | 0 | 1 | 259 | 1 |
Proline | boiler | 122 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend | 5 | 0 | 1 | 260 | 1 |
Proline | boiler | 122 | summertemp | summer temperature | uint8 (>=0<=45) | C | True | number.boiler_summer_temperature | number.boiler_summertemp | 5 | 0 | 1 | 261 | 1 |
Proline | boiler | 122 | nofrostmode | nofrost mode | boolean | | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | 5 | 0 | 1 | 262 | 1 |
Proline | boiler | 122 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp | 5 | 0 | 1 | 263 | 1 |
Proline | boiler | 122 | heatingactivated | heating activated | boolean | | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | 5 | 0 | 1 | 13 | 1 |
Proline | boiler | 122 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp | 5 | 0 | 1 | 14 | 1 |
Proline | boiler | 122 | heatingpump | heating pump | boolean | | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | 5 | 0 | 1 | 15 | 1 |
Proline | boiler | 122 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax | 5 | 0 | 1 | 16 | 1 |
Proline | boiler | 122 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin | 5 | 0 | 1 | 17 | 1 |
Proline | boiler | 122 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | 5 | 0 | 1 | 18 | 1 |
Proline | boiler | 122 | pumpcharacter | boiler pump characteristic | enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] | | True | select.boiler_boiler_pump_characteristic | select.boiler_pumpcharacter | 5 | 0 | 1 | 19 | 1 |
Proline | boiler | 122 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay | 5 | 0 | 1 | 20 | 1 |
Proline | boiler | 122 | pumpontemp | pump logic temperature | uint8 (>=0<=60) | C | True | number.boiler_pump_logic_temperature | number.boiler_pumpontemp | 5 | 0 | 1 | 21 | 1 |
Proline | boiler | 122 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow | 5 | 0 | 1 | 22 | 1 |
Proline | boiler | 122 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow | 5 | 0 | 1 | 23 | 1 |
Proline | boiler | 122 | burnstarts | burner starts | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | 5 | 0 | 1 | 24 | 2 |
Proline | boiler | 122 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin | 5 | 0 | 1 | 26 | 2 |
Proline | boiler | 122 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin | 5 | 0 | 1 | 28 | 2 |
Proline | boiler | 122 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin | 5 | 0 | 1 | 30 | 2 |
Proline | boiler | 122 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | 5 | 0 | 1 | 32 | 2 |
Proline | boiler | 122 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime | 5 | 0 | 1 | 34 | 2 |
Proline | boiler | 122 | lastcode | last error code | string | | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | 5 | 0 | 1 | 36 | 28 |
Proline | boiler | 122 | servicecode | service code | string | | False | sensor.boiler_service_code | sensor.boiler_servicecode | 5 | 0 | 1 | 64 | 2 |
Proline | boiler | 122 | servicecodenumber | service code number | uint16 (>=0<=31999) | | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | 5 | 0 | 1 | 66 | 1 |
Proline | boiler | 122 | maintenancemessage | maintenance message | string | | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | 5 | 0 | 1 | 67 | 2 |
Proline | boiler | 122 | maintenance | maintenance scheduled | enum [off|time|date|manual] | | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | 5 | 0 | 1 | 69 | 1 |
Proline | boiler | 122 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime | 5 | 0 | 1 | 70 | 1 |
Proline | boiler | 122 | maintenancedate | next maintenance date | string | | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | 5 | 0 | 1 | 71 | 6 |
Proline | boiler | 122 | emergencyops | emergency operation | boolean | | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | 5 | 0 | 1 | 77 | 1 |
Proline | boiler | 122 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp | 5 | 0 | 1 | 78 | 1 |
Proline | boiler | 122 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat | 5 | 0 | 1/10 | 91 | 2 |
Proline | boiler | 122 | meter | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meter | 5 | 9 | 1/10 | 2 | 2 |
Proline | boiler | 122 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat | 5 | 0 | 1/10 | 264 | 2 |
Proline | boiler | 122 | gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeter | 5 | 9 | 1/10 | 69 | 2 |
Proline | boiler | 122 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 | 5 | 0 | 1/10 | 266 | 2 |
Proline | boiler | 122 | nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrg2 | 5 | 9 | 1/10 | 71 | 2 |
Proline | boiler | 122 | tapactivated | turn on/off | boolean | | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | 5 | 9 | 1 | 28 | 1 |
Proline | boiler | 122 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp | 5 | 9 | 1 | 29 | 1 |
Proline | boiler | 122 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp | 5 | 9 | 1 | 30 | 1 |
Proline | boiler | 122 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow | 5 | 9 | 1 | 31 | 1 |
Proline | boiler | 122 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus | 5 | 9 | 1 | 32 | 1 |
Proline | boiler | 122 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff | 5 | 9 | 1 | 33 | 1 |
Proline | boiler | 122 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle | 5 | 9 | 1 | 34 | 1 |
Proline | boiler | 122 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp | 5 | 9 | 1/10 | 35 | 1 |
Proline | boiler | 122 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | 5 | 9 | 1 | 36 | 1 |
Proline | boiler | 122 | comfort | comfort | enum [hot|eco|intelligent] | | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | 5 | 9 | 1 | 37 | 1 |
Proline | boiler | 122 | comfort1 | comfort mode | enum [high comfort|eco] | | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | 5 | 9 | 1 | 38 | 1 |
Proline | boiler | 122 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset | 5 | 9 | 1 | 39 | 1 |
Proline | boiler | 122 | chargeoptimization | charge optimization | boolean | | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | 5 | 9 | 1 | 40 | 1 |
Proline | boiler | 122 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower | 5 | 9 | 1 | 41 | 1 |
Proline | boiler | 122 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp | 5 | 9 | 1 | 42 | 1 |
Proline | boiler | 122 | circpump | circulation pump available | boolean | | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | 5 | 9 | 1 | 43 | 1 |
Proline | boiler | 122 | chargetype | charging type | enum [chargepump|3-way valve] | | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | 5 | 9 | 1 | 44 | 1 |
Proline | boiler | 122 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston | 5 | 9 | 1 | 45 | 1 |
Proline | boiler | 122 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff | 5 | 9 | 1 | 46 | 1 |
Proline | boiler | 122 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp | 5 | 9 | 1 | 47 | 1 |
Proline | boiler | 122 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | 5 | 9 | 1 | 48 | 1 |
Proline | boiler | 122 | circ | circulation active | boolean | | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | 5 | 9 | 1 | 49 | 1 |
Proline | boiler | 122 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp | 5 | 9 | 1/10 | 50 | 1 |
Proline | boiler | 122 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 | 5 | 9 | 1/10 | 51 | 1 |
Proline | boiler | 122 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow | 5 | 9 | 1/10 | 52 | 1 |
Proline | boiler | 122 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 | 5 | 9 | 1/10 | 53 | 1 |
Proline | boiler | 122 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 | 5 | 9 | 1/10 | 54 | 1 |
Proline | boiler | 122 | activated | activated | boolean | | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | 5 | 9 | 1 | 55 | 1 |
Proline | boiler | 122 | onetime | one time charging | boolean | | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | 5 | 9 | 1 | 56 | 1 |
Proline | boiler | 122 | disinfecting | disinfecting | boolean | | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | 5 | 9 | 1 | 57 | 1 |
Proline | boiler | 122 | charging | charging | boolean | | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | 5 | 9 | 1 | 58 | 1 |
Proline | boiler | 122 | recharging | recharging | boolean | | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | 5 | 9 | 1 | 59 | 1 |
Proline | boiler | 122 | tempok | temperature ok | boolean | | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | 5 | 9 | 1 | 60 | 1 |
Proline | boiler | 122 | active | active | boolean | | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | 5 | 9 | 1 | 61 | 1 |
Proline | boiler | 122 | 3wayvalve | 3-way valve active | boolean | | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | 5 | 9 | 1 | 62 | 1 |
Proline | boiler | 122 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp | 5 | 9 | 1/10 | 63 | 1 |
Proline | boiler | 122 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp | 5 | 9 | 1/10 | 64 | 1 |
Proline | boiler | 122 | starts | starts | uint24 (>=0<=16777213) | | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | 5 | 9 | 1 | 65 | 2 |
Proline | boiler | 122 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm | 5 | 9 | 1 | 67 | 2 |
Proline | boiler | 122 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower | 5 | 0 | 1 | 268 | 1 |
Proline | boiler | 122 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal | 5 | 0 | 1/100 | 79 | 2 |
Proline | boiler | 122 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat | 5 | 0 | 1/100 | 81 | 2 |
Proline | boiler | 122 | nrg | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrg | 5 | 9 | 1/100 | 0 | 2 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | reset | reset | cmd [-|maintenance|error|history|message] | | True | sensor.boiler_reset | sensor.boiler_reset | 5 | 0 | 1 | 0 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | heatingoff | force heating off | boolean | | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | 5 | 0 | 1 | 1 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | heatingactive | heating active | boolean | | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | 5 | 0 | 1 | 2 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | tapwateractive | tapwater active | boolean | | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | 5 | 0 | 1 | 3 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp | 5 | 0 | 1 | 4 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod | 5 | 0 | 1 | 5 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp | 5 | 0 | 1/10 | 6 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp | 5 | 0 | 1/10 | 7 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp | 5 | 0 | 1/10 | 8 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp | 5 | 0 | 1/10 | 9 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress | 5 | 0 | 1/10 | 10 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp | 5 | 0 | 1/10 | 11 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp | 5 | 0 | 1/10 | 12 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp | 5 | 0 | 1/10 | 242 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | burngas | gas | boolean | | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | 5 | 0 | 1 | 243 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | burngas2 | gas stage 2 | boolean | | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | 5 | 0 | 1 | 244 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr | 5 | 0 | 1/10 | 245 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | fanwork | fan | boolean | | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | 5 | 0 | 1 | 246 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | ignwork | ignition | boolean | | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | 5 | 0 | 1 | 247 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | oilpreheat | oil preheating | boolean | | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | 5 | 0 | 1 | 248 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower | 5 | 0 | 1 | 249 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower | 5 | 0 | 1 | 250 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod | 5 | 0 | 1 | 251 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow | 5 | 0 | 1 | 252 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock | 5 | 0 | 1/10 | 253 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston | 5 | 0 | 1 | 254 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff | 5 | 0 | 1 | 255 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston | 5 | 0 | 1 | 256 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff | 5 | 0 | 1 | 257 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | curveon | heatingcurve on | boolean | | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | 5 | 0 | 1 | 258 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase | 5 | 0 | 1 | 259 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend | 5 | 0 | 1 | 260 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | summertemp | summer temperature | uint8 (>=0<=45) | C | True | number.boiler_summer_temperature | number.boiler_summertemp | 5 | 0 | 1 | 261 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | nofrostmode | nofrost mode | boolean | | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | 5 | 0 | 1 | 262 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp | 5 | 0 | 1 | 263 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | heatingactivated | heating activated | boolean | | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | 5 | 0 | 1 | 13 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp | 5 | 0 | 1 | 14 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | heatingpump | heating pump | boolean | | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | 5 | 0 | 1 | 15 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax | 5 | 0 | 1 | 16 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin | 5 | 0 | 1 | 17 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | 5 | 0 | 1 | 18 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | pumpcharacter | boiler pump characteristic | enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] | | True | select.boiler_boiler_pump_characteristic | select.boiler_pumpcharacter | 5 | 0 | 1 | 19 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay | 5 | 0 | 1 | 20 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | pumpontemp | pump logic temperature | uint8 (>=0<=60) | C | True | number.boiler_pump_logic_temperature | number.boiler_pumpontemp | 5 | 0 | 1 | 21 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow | 5 | 0 | 1 | 22 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow | 5 | 0 | 1 | 23 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | burnstarts | burner starts | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | 5 | 0 | 1 | 24 | 2 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin | 5 | 0 | 1 | 26 | 2 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin | 5 | 0 | 1 | 28 | 2 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin | 5 | 0 | 1 | 30 | 2 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | 5 | 0 | 1 | 32 | 2 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime | 5 | 0 | 1 | 34 | 2 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | lastcode | last error code | string | | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | 5 | 0 | 1 | 36 | 28 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | servicecode | service code | string | | False | sensor.boiler_service_code | sensor.boiler_servicecode | 5 | 0 | 1 | 64 | 2 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | servicecodenumber | service code number | uint16 (>=0<=31999) | | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | 5 | 0 | 1 | 66 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | maintenancemessage | maintenance message | string | | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | 5 | 0 | 1 | 67 | 2 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | maintenance | maintenance scheduled | enum [off|time|date|manual] | | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | 5 | 0 | 1 | 69 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime | 5 | 0 | 1 | 70 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | maintenancedate | next maintenance date | string | | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | 5 | 0 | 1 | 71 | 6 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | emergencyops | emergency operation | boolean | | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | 5 | 0 | 1 | 77 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp | 5 | 0 | 1 | 78 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat | 5 | 0 | 1/10 | 91 | 2 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | meter | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meter | 5 | 9 | 1/10 | 2 | 2 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat | 5 | 0 | 1/10 | 264 | 2 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeter | 5 | 9 | 1/10 | 69 | 2 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 | 5 | 0 | 1/10 | 266 | 2 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrg2 | 5 | 9 | 1/10 | 71 | 2 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | tapactivated | turn on/off | boolean | | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | 5 | 9 | 1 | 28 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp | 5 | 9 | 1 | 29 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp | 5 | 9 | 1 | 30 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow | 5 | 9 | 1 | 31 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus | 5 | 9 | 1 | 32 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff | 5 | 9 | 1 | 33 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle | 5 | 9 | 1 | 34 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp | 5 | 9 | 1/10 | 35 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | 5 | 9 | 1 | 36 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | comfort | comfort | enum [hot|eco|intelligent] | | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | 5 | 9 | 1 | 37 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | comfort1 | comfort mode | enum [high comfort|eco] | | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | 5 | 9 | 1 | 38 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset | 5 | 9 | 1 | 39 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | chargeoptimization | charge optimization | boolean | | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | 5 | 9 | 1 | 40 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower | 5 | 9 | 1 | 41 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp | 5 | 9 | 1 | 42 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | circpump | circulation pump available | boolean | | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | 5 | 9 | 1 | 43 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | chargetype | charging type | enum [chargepump|3-way valve] | | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | 5 | 9 | 1 | 44 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston | 5 | 9 | 1 | 45 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff | 5 | 9 | 1 | 46 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp | 5 | 9 | 1 | 47 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | 5 | 9 | 1 | 48 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | circ | circulation active | boolean | | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | 5 | 9 | 1 | 49 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp | 5 | 9 | 1/10 | 50 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 | 5 | 9 | 1/10 | 51 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow | 5 | 9 | 1/10 | 52 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 | 5 | 9 | 1/10 | 53 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 | 5 | 9 | 1/10 | 54 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | activated | activated | boolean | | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | 5 | 9 | 1 | 55 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | onetime | one time charging | boolean | | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | 5 | 9 | 1 | 56 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | disinfecting | disinfecting | boolean | | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | 5 | 9 | 1 | 57 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | charging | charging | boolean | | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | 5 | 9 | 1 | 58 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | recharging | recharging | boolean | | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | 5 | 9 | 1 | 59 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | tempok | temperature ok | boolean | | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | 5 | 9 | 1 | 60 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | active | active | boolean | | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | 5 | 9 | 1 | 61 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | 3wayvalve | 3-way valve active | boolean | | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | 5 | 9 | 1 | 62 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp | 5 | 9 | 1/10 | 63 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp | 5 | 9 | 1/10 | 64 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | starts | starts | uint24 (>=0<=16777213) | | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | 5 | 9 | 1 | 65 | 2 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm | 5 | 9 | 1 | 67 | 2 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower | 5 | 0 | 1 | 268 | 1 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal | 5 | 0 | 1/100 | 79 | 2 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat | 5 | 0 | 1/100 | 81 | 2 |
GB*72, Trendline, Cerapur, Greenstar Si | boiler | 123 | nrg | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrg | 5 | 9 | 1/100 | 0 | 2 |
GB212 | boiler | 131 | reset | reset | cmd [-|maintenance|error|history|message] | | True | sensor.boiler_reset | sensor.boiler_reset | 5 | 0 | 1 | 0 | 1 |
GB212 | boiler | 131 | heatingoff | force heating off | boolean | | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | 5 | 0 | 1 | 1 | 1 |
GB212 | boiler | 131 | heatingactive | heating active | boolean | | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | 5 | 0 | 1 | 2 | 1 |
GB212 | boiler | 131 | tapwateractive | tapwater active | boolean | | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | 5 | 0 | 1 | 3 | 1 |
GB212 | boiler | 131 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp | 5 | 0 | 1 | 4 | 1 |
GB212 | boiler | 131 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod | 5 | 0 | 1 | 5 | 1 |
GB212 | boiler | 131 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp | 5 | 0 | 1/10 | 6 | 1 |
GB212 | boiler | 131 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp | 5 | 0 | 1/10 | 7 | 1 |
GB212 | boiler | 131 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp | 5 | 0 | 1/10 | 8 | 1 |
GB212 | boiler | 131 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp | 5 | 0 | 1/10 | 9 | 1 |
GB212 | boiler | 131 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress | 5 | 0 | 1/10 | 10 | 1 |
GB212 | boiler | 131 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp | 5 | 0 | 1/10 | 11 | 1 |
GB212 | boiler | 131 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp | 5 | 0 | 1/10 | 12 | 1 |
GB212 | boiler | 131 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp | 5 | 0 | 1/10 | 242 | 1 |
GB212 | boiler | 131 | burngas | gas | boolean | | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | 5 | 0 | 1 | 243 | 1 |
GB212 | boiler | 131 | burngas2 | gas stage 2 | boolean | | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | 5 | 0 | 1 | 244 | 1 |
GB212 | boiler | 131 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr | 5 | 0 | 1/10 | 245 | 1 |
GB212 | boiler | 131 | fanwork | fan | boolean | | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | 5 | 0 | 1 | 246 | 1 |
GB212 | boiler | 131 | ignwork | ignition | boolean | | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | 5 | 0 | 1 | 247 | 1 |
GB212 | boiler | 131 | oilpreheat | oil preheating | boolean | | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | 5 | 0 | 1 | 248 | 1 |
GB212 | boiler | 131 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower | 5 | 0 | 1 | 249 | 1 |
GB212 | boiler | 131 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower | 5 | 0 | 1 | 250 | 1 |
GB212 | boiler | 131 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod | 5 | 0 | 1 | 251 | 1 |
GB212 | boiler | 131 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow | 5 | 0 | 1 | 252 | 1 |
GB212 | boiler | 131 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock | 5 | 0 | 1/10 | 253 | 1 |
GB212 | boiler | 131 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston | 5 | 0 | 1 | 254 | 1 |
GB212 | boiler | 131 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff | 5 | 0 | 1 | 255 | 1 |
GB212 | boiler | 131 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston | 5 | 0 | 1 | 256 | 1 |
GB212 | boiler | 131 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff | 5 | 0 | 1 | 257 | 1 |
GB212 | boiler | 131 | curveon | heatingcurve on | boolean | | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | 5 | 0 | 1 | 258 | 1 |
GB212 | boiler | 131 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase | 5 | 0 | 1 | 259 | 1 |
GB212 | boiler | 131 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend | 5 | 0 | 1 | 260 | 1 |
GB212 | boiler | 131 | summertemp | summer temperature | uint8 (>=0<=45) | C | True | number.boiler_summer_temperature | number.boiler_summertemp | 5 | 0 | 1 | 261 | 1 |
GB212 | boiler | 131 | nofrostmode | nofrost mode | boolean | | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | 5 | 0 | 1 | 262 | 1 |
GB212 | boiler | 131 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp | 5 | 0 | 1 | 263 | 1 |
GB212 | boiler | 131 | heatingactivated | heating activated | boolean | | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | 5 | 0 | 1 | 13 | 1 |
GB212 | boiler | 131 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp | 5 | 0 | 1 | 14 | 1 |
GB212 | boiler | 131 | heatingpump | heating pump | boolean | | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | 5 | 0 | 1 | 15 | 1 |
GB212 | boiler | 131 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax | 5 | 0 | 1 | 16 | 1 |
GB212 | boiler | 131 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin | 5 | 0 | 1 | 17 | 1 |
GB212 | boiler | 131 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | 5 | 0 | 1 | 18 | 1 |
GB212 | boiler | 131 | pumpcharacter | boiler pump characteristic | enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] | | True | select.boiler_boiler_pump_characteristic | select.boiler_pumpcharacter | 5 | 0 | 1 | 19 | 1 |
GB212 | boiler | 131 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay | 5 | 0 | 1 | 20 | 1 |
GB212 | boiler | 131 | pumpontemp | pump logic temperature | uint8 (>=0<=60) | C | True | number.boiler_pump_logic_temperature | number.boiler_pumpontemp | 5 | 0 | 1 | 21 | 1 |
GB212 | boiler | 131 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow | 5 | 0 | 1 | 22 | 1 |
GB212 | boiler | 131 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow | 5 | 0 | 1 | 23 | 1 |
GB212 | boiler | 131 | burnstarts | burner starts | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | 5 | 0 | 1 | 24 | 2 |
GB212 | boiler | 131 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin | 5 | 0 | 1 | 26 | 2 |
GB212 | boiler | 131 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin | 5 | 0 | 1 | 28 | 2 |
GB212 | boiler | 131 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin | 5 | 0 | 1 | 30 | 2 |
GB212 | boiler | 131 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | 5 | 0 | 1 | 32 | 2 |
GB212 | boiler | 131 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime | 5 | 0 | 1 | 34 | 2 |
GB212 | boiler | 131 | lastcode | last error code | string | | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | 5 | 0 | 1 | 36 | 28 |
GB212 | boiler | 131 | servicecode | service code | string | | False | sensor.boiler_service_code | sensor.boiler_servicecode | 5 | 0 | 1 | 64 | 2 |
GB212 | boiler | 131 | servicecodenumber | service code number | uint16 (>=0<=31999) | | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | 5 | 0 | 1 | 66 | 1 |
GB212 | boiler | 131 | maintenancemessage | maintenance message | string | | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | 5 | 0 | 1 | 67 | 2 |
GB212 | boiler | 131 | maintenance | maintenance scheduled | enum [off|time|date|manual] | | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | 5 | 0 | 1 | 69 | 1 |
GB212 | boiler | 131 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime | 5 | 0 | 1 | 70 | 1 |
GB212 | boiler | 131 | maintenancedate | next maintenance date | string | | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | 5 | 0 | 1 | 71 | 6 |
GB212 | boiler | 131 | emergencyops | emergency operation | boolean | | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | 5 | 0 | 1 | 77 | 1 |
GB212 | boiler | 131 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp | 5 | 0 | 1 | 78 | 1 |
GB212 | boiler | 131 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat | 5 | 0 | 1/10 | 91 | 2 |
GB212 | boiler | 131 | meter | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meter | 5 | 9 | 1/10 | 2 | 2 |
GB212 | boiler | 131 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat | 5 | 0 | 1/10 | 264 | 2 |
GB212 | boiler | 131 | gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeter | 5 | 9 | 1/10 | 69 | 2 |
GB212 | boiler | 131 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 | 5 | 0 | 1/10 | 266 | 2 |
GB212 | boiler | 131 | nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrg2 | 5 | 9 | 1/10 | 71 | 2 |
GB212 | boiler | 131 | tapactivated | turn on/off | boolean | | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | 5 | 9 | 1 | 28 | 1 |
GB212 | boiler | 131 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp | 5 | 9 | 1 | 29 | 1 |
GB212 | boiler | 131 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp | 5 | 9 | 1 | 30 | 1 |
GB212 | boiler | 131 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow | 5 | 9 | 1 | 31 | 1 |
GB212 | boiler | 131 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus | 5 | 9 | 1 | 32 | 1 |
GB212 | boiler | 131 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff | 5 | 9 | 1 | 33 | 1 |
GB212 | boiler | 131 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle | 5 | 9 | 1 | 34 | 1 |
GB212 | boiler | 131 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp | 5 | 9 | 1/10 | 35 | 1 |
GB212 | boiler | 131 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | 5 | 9 | 1 | 36 | 1 |
GB212 | boiler | 131 | comfort | comfort | enum [hot|eco|intelligent] | | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | 5 | 9 | 1 | 37 | 1 |
GB212 | boiler | 131 | comfort1 | comfort mode | enum [high comfort|eco] | | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | 5 | 9 | 1 | 38 | 1 |
GB212 | boiler | 131 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset | 5 | 9 | 1 | 39 | 1 |
GB212 | boiler | 131 | chargeoptimization | charge optimization | boolean | | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | 5 | 9 | 1 | 40 | 1 |
GB212 | boiler | 131 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower | 5 | 9 | 1 | 41 | 1 |
GB212 | boiler | 131 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp | 5 | 9 | 1 | 42 | 1 |
GB212 | boiler | 131 | circpump | circulation pump available | boolean | | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | 5 | 9 | 1 | 43 | 1 |
GB212 | boiler | 131 | chargetype | charging type | enum [chargepump|3-way valve] | | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | 5 | 9 | 1 | 44 | 1 |
GB212 | boiler | 131 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston | 5 | 9 | 1 | 45 | 1 |
GB212 | boiler | 131 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff | 5 | 9 | 1 | 46 | 1 |
GB212 | boiler | 131 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp | 5 | 9 | 1 | 47 | 1 |
GB212 | boiler | 131 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | 5 | 9 | 1 | 48 | 1 |
GB212 | boiler | 131 | circ | circulation active | boolean | | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | 5 | 9 | 1 | 49 | 1 |
GB212 | boiler | 131 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp | 5 | 9 | 1/10 | 50 | 1 |
GB212 | boiler | 131 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 | 5 | 9 | 1/10 | 51 | 1 |
GB212 | boiler | 131 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow | 5 | 9 | 1/10 | 52 | 1 |
GB212 | boiler | 131 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 | 5 | 9 | 1/10 | 53 | 1 |
GB212 | boiler | 131 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 | 5 | 9 | 1/10 | 54 | 1 |
GB212 | boiler | 131 | activated | activated | boolean | | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | 5 | 9 | 1 | 55 | 1 |
GB212 | boiler | 131 | onetime | one time charging | boolean | | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | 5 | 9 | 1 | 56 | 1 |
GB212 | boiler | 131 | disinfecting | disinfecting | boolean | | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | 5 | 9 | 1 | 57 | 1 |
GB212 | boiler | 131 | charging | charging | boolean | | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | 5 | 9 | 1 | 58 | 1 |
GB212 | boiler | 131 | recharging | recharging | boolean | | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | 5 | 9 | 1 | 59 | 1 |
GB212 | boiler | 131 | tempok | temperature ok | boolean | | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | 5 | 9 | 1 | 60 | 1 |
GB212 | boiler | 131 | active | active | boolean | | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | 5 | 9 | 1 | 61 | 1 |
GB212 | boiler | 131 | 3wayvalve | 3-way valve active | boolean | | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | 5 | 9 | 1 | 62 | 1 |
GB212 | boiler | 131 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp | 5 | 9 | 1/10 | 63 | 1 |
GB212 | boiler | 131 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp | 5 | 9 | 1/10 | 64 | 1 |
GB212 | boiler | 131 | starts | starts | uint24 (>=0<=16777213) | | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | 5 | 9 | 1 | 65 | 2 |
GB212 | boiler | 131 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm | 5 | 9 | 1 | 67 | 2 |
GB212 | boiler | 131 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower | 5 | 0 | 1 | 268 | 1 |
GB212 | boiler | 131 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal | 5 | 0 | 1/100 | 79 | 2 |
GB212 | boiler | 131 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat | 5 | 0 | 1/100 | 81 | 2 |
GB212 | boiler | 131 | nrg | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrg | 5 | 9 | 1/100 | 0 | 2 |
GC7000F | boiler | 132 | reset | reset | cmd [-|maintenance|error|history|message] | | True | sensor.boiler_reset | sensor.boiler_reset | 5 | 0 | 1 | 0 | 1 |
GC7000F | boiler | 132 | heatingoff | force heating off | boolean | | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | 5 | 0 | 1 | 1 | 1 |
GC7000F | boiler | 132 | heatingactive | heating active | boolean | | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | 5 | 0 | 1 | 2 | 1 |
GC7000F | boiler | 132 | tapwateractive | tapwater active | boolean | | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | 5 | 0 | 1 | 3 | 1 |
GC7000F | boiler | 132 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp | 5 | 0 | 1 | 4 | 1 |
GC7000F | boiler | 132 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod | 5 | 0 | 1 | 5 | 1 |
GC7000F | boiler | 132 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp | 5 | 0 | 1/10 | 6 | 1 |
GC7000F | boiler | 132 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp | 5 | 0 | 1/10 | 7 | 1 |
GC7000F | boiler | 132 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp | 5 | 0 | 1/10 | 8 | 1 |
GC7000F | boiler | 132 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp | 5 | 0 | 1/10 | 9 | 1 |
GC7000F | boiler | 132 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress | 5 | 0 | 1/10 | 10 | 1 |
GC7000F | boiler | 132 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp | 5 | 0 | 1/10 | 11 | 1 |
GC7000F | boiler | 132 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp | 5 | 0 | 1/10 | 12 | 1 |
GC7000F | boiler | 132 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp | 5 | 0 | 1/10 | 242 | 1 |
GC7000F | boiler | 132 | burngas | gas | boolean | | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | 5 | 0 | 1 | 243 | 1 |
GC7000F | boiler | 132 | burngas2 | gas stage 2 | boolean | | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | 5 | 0 | 1 | 244 | 1 |
GC7000F | boiler | 132 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr | 5 | 0 | 1/10 | 245 | 1 |
GC7000F | boiler | 132 | fanwork | fan | boolean | | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | 5 | 0 | 1 | 246 | 1 |
GC7000F | boiler | 132 | ignwork | ignition | boolean | | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | 5 | 0 | 1 | 247 | 1 |
GC7000F | boiler | 132 | oilpreheat | oil preheating | boolean | | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | 5 | 0 | 1 | 248 | 1 |
GC7000F | boiler | 132 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower | 5 | 0 | 1 | 249 | 1 |
GC7000F | boiler | 132 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower | 5 | 0 | 1 | 250 | 1 |
GC7000F | boiler | 132 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod | 5 | 0 | 1 | 251 | 1 |
GC7000F | boiler | 132 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow | 5 | 0 | 1 | 252 | 1 |
GC7000F | boiler | 132 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock | 5 | 0 | 1/10 | 253 | 1 |
GC7000F | boiler | 132 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston | 5 | 0 | 1 | 254 | 1 |
GC7000F | boiler | 132 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff | 5 | 0 | 1 | 255 | 1 |
GC7000F | boiler | 132 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston | 5 | 0 | 1 | 256 | 1 |
GC7000F | boiler | 132 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff | 5 | 0 | 1 | 257 | 1 |
GC7000F | boiler | 132 | curveon | heatingcurve on | boolean | | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | 5 | 0 | 1 | 258 | 1 |
GC7000F | boiler | 132 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase | 5 | 0 | 1 | 259 | 1 |
GC7000F | boiler | 132 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend | 5 | 0 | 1 | 260 | 1 |
GC7000F | boiler | 132 | summertemp | summer temperature | uint8 (>=0<=45) | C | True | number.boiler_summer_temperature | number.boiler_summertemp | 5 | 0 | 1 | 261 | 1 |
GC7000F | boiler | 132 | nofrostmode | nofrost mode | boolean | | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | 5 | 0 | 1 | 262 | 1 |
GC7000F | boiler | 132 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp | 5 | 0 | 1 | 263 | 1 |
GC7000F | boiler | 132 | heatingactivated | heating activated | boolean | | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | 5 | 0 | 1 | 13 | 1 |
GC7000F | boiler | 132 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp | 5 | 0 | 1 | 14 | 1 |
GC7000F | boiler | 132 | heatingpump | heating pump | boolean | | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | 5 | 0 | 1 | 15 | 1 |
GC7000F | boiler | 132 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax | 5 | 0 | 1 | 16 | 1 |
GC7000F | boiler | 132 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin | 5 | 0 | 1 | 17 | 1 |
GC7000F | boiler | 132 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | 5 | 0 | 1 | 18 | 1 |
GC7000F | boiler | 132 | pumpcharacter | boiler pump characteristic | enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] | | True | select.boiler_boiler_pump_characteristic | select.boiler_pumpcharacter | 5 | 0 | 1 | 19 | 1 |
GC7000F | boiler | 132 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay | 5 | 0 | 1 | 20 | 1 |
GC7000F | boiler | 132 | pumpontemp | pump logic temperature | uint8 (>=0<=60) | C | True | number.boiler_pump_logic_temperature | number.boiler_pumpontemp | 5 | 0 | 1 | 21 | 1 |
GC7000F | boiler | 132 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow | 5 | 0 | 1 | 22 | 1 |
GC7000F | boiler | 132 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow | 5 | 0 | 1 | 23 | 1 |
GC7000F | boiler | 132 | burnstarts | burner starts | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | 5 | 0 | 1 | 24 | 2 |
GC7000F | boiler | 132 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin | 5 | 0 | 1 | 26 | 2 |
GC7000F | boiler | 132 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin | 5 | 0 | 1 | 28 | 2 |
GC7000F | boiler | 132 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin | 5 | 0 | 1 | 30 | 2 |
GC7000F | boiler | 132 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | 5 | 0 | 1 | 32 | 2 |
GC7000F | boiler | 132 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime | 5 | 0 | 1 | 34 | 2 |
GC7000F | boiler | 132 | lastcode | last error code | string | | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | 5 | 0 | 1 | 36 | 28 |
GC7000F | boiler | 132 | servicecode | service code | string | | False | sensor.boiler_service_code | sensor.boiler_servicecode | 5 | 0 | 1 | 64 | 2 |
GC7000F | boiler | 132 | servicecodenumber | service code number | uint16 (>=0<=31999) | | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | 5 | 0 | 1 | 66 | 1 |
GC7000F | boiler | 132 | maintenancemessage | maintenance message | string | | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | 5 | 0 | 1 | 67 | 2 |
GC7000F | boiler | 132 | maintenance | maintenance scheduled | enum [off|time|date|manual] | | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | 5 | 0 | 1 | 69 | 1 |
GC7000F | boiler | 132 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime | 5 | 0 | 1 | 70 | 1 |
GC7000F | boiler | 132 | maintenancedate | next maintenance date | string | | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | 5 | 0 | 1 | 71 | 6 |
GC7000F | boiler | 132 | emergencyops | emergency operation | boolean | | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | 5 | 0 | 1 | 77 | 1 |
GC7000F | boiler | 132 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp | 5 | 0 | 1 | 78 | 1 |
GC7000F | boiler | 132 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat | 5 | 0 | 1/10 | 91 | 2 |
GC7000F | boiler | 132 | meter | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meter | 5 | 9 | 1/10 | 2 | 2 |
GC7000F | boiler | 132 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat | 5 | 0 | 1/10 | 264 | 2 |
GC7000F | boiler | 132 | gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeter | 5 | 9 | 1/10 | 69 | 2 |
GC7000F | boiler | 132 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 | 5 | 0 | 1/10 | 266 | 2 |
GC7000F | boiler | 132 | nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrg2 | 5 | 9 | 1/10 | 71 | 2 |
GC7000F | boiler | 132 | tapactivated | turn on/off | boolean | | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | 5 | 9 | 1 | 28 | 1 |
GC7000F | boiler | 132 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp | 5 | 9 | 1 | 29 | 1 |
GC7000F | boiler | 132 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp | 5 | 9 | 1 | 30 | 1 |
GC7000F | boiler | 132 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow | 5 | 9 | 1 | 31 | 1 |
GC7000F | boiler | 132 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus | 5 | 9 | 1 | 32 | 1 |
GC7000F | boiler | 132 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff | 5 | 9 | 1 | 33 | 1 |
GC7000F | boiler | 132 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle | 5 | 9 | 1 | 34 | 1 |
GC7000F | boiler | 132 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp | 5 | 9 | 1/10 | 35 | 1 |
GC7000F | boiler | 132 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | 5 | 9 | 1 | 36 | 1 |
GC7000F | boiler | 132 | comfort | comfort | enum [hot|eco|intelligent] | | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | 5 | 9 | 1 | 37 | 1 |
GC7000F | boiler | 132 | comfort1 | comfort mode | enum [high comfort|eco] | | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | 5 | 9 | 1 | 38 | 1 |
GC7000F | boiler | 132 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset | 5 | 9 | 1 | 39 | 1 |
GC7000F | boiler | 132 | chargeoptimization | charge optimization | boolean | | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | 5 | 9 | 1 | 40 | 1 |
GC7000F | boiler | 132 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower | 5 | 9 | 1 | 41 | 1 |
GC7000F | boiler | 132 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp | 5 | 9 | 1 | 42 | 1 |
GC7000F | boiler | 132 | circpump | circulation pump available | boolean | | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | 5 | 9 | 1 | 43 | 1 |
GC7000F | boiler | 132 | chargetype | charging type | enum [chargepump|3-way valve] | | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | 5 | 9 | 1 | 44 | 1 |
GC7000F | boiler | 132 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston | 5 | 9 | 1 | 45 | 1 |
GC7000F | boiler | 132 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff | 5 | 9 | 1 | 46 | 1 |
GC7000F | boiler | 132 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp | 5 | 9 | 1 | 47 | 1 |
GC7000F | boiler | 132 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | 5 | 9 | 1 | 48 | 1 |
GC7000F | boiler | 132 | circ | circulation active | boolean | | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | 5 | 9 | 1 | 49 | 1 |
GC7000F | boiler | 132 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp | 5 | 9 | 1/10 | 50 | 1 |
GC7000F | boiler | 132 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 | 5 | 9 | 1/10 | 51 | 1 |
GC7000F | boiler | 132 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow | 5 | 9 | 1/10 | 52 | 1 |
GC7000F | boiler | 132 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 | 5 | 9 | 1/10 | 53 | 1 |
GC7000F | boiler | 132 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 | 5 | 9 | 1/10 | 54 | 1 |
GC7000F | boiler | 132 | activated | activated | boolean | | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | 5 | 9 | 1 | 55 | 1 |
GC7000F | boiler | 132 | onetime | one time charging | boolean | | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | 5 | 9 | 1 | 56 | 1 |
GC7000F | boiler | 132 | disinfecting | disinfecting | boolean | | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | 5 | 9 | 1 | 57 | 1 |
GC7000F | boiler | 132 | charging | charging | boolean | | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | 5 | 9 | 1 | 58 | 1 |
GC7000F | boiler | 132 | recharging | recharging | boolean | | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | 5 | 9 | 1 | 59 | 1 |
GC7000F | boiler | 132 | tempok | temperature ok | boolean | | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | 5 | 9 | 1 | 60 | 1 |
GC7000F | boiler | 132 | active | active | boolean | | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | 5 | 9 | 1 | 61 | 1 |
GC7000F | boiler | 132 | 3wayvalve | 3-way valve active | boolean | | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | 5 | 9 | 1 | 62 | 1 |
GC7000F | boiler | 132 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp | 5 | 9 | 1/10 | 63 | 1 |
GC7000F | boiler | 132 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp | 5 | 9 | 1/10 | 64 | 1 |
GC7000F | boiler | 132 | starts | starts | uint24 (>=0<=16777213) | | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | 5 | 9 | 1 | 65 | 2 |
GC7000F | boiler | 132 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm | 5 | 9 | 1 | 67 | 2 |
GC7000F | boiler | 132 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower | 5 | 0 | 1 | 268 | 1 |
GC7000F | boiler | 132 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal | 5 | 0 | 1/100 | 79 | 2 |
GC7000F | boiler | 132 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat | 5 | 0 | 1/100 | 81 | 2 |
GC7000F | boiler | 132 | nrg | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrg | 5 | 9 | 1/100 | 0 | 2 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | reset | reset | cmd [-|maintenance|error|history|message] | | True | sensor.boiler_reset | sensor.boiler_reset | 5 | 0 | 1 | 0 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | heatingoff | force heating off | boolean | | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | 5 | 0 | 1 | 1 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | heatingactive | heating active | boolean | | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | 5 | 0 | 1 | 2 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | tapwateractive | tapwater active | boolean | | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | 5 | 0 | 1 | 3 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp | 5 | 0 | 1 | 4 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod | 5 | 0 | 1 | 5 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp | 5 | 0 | 1/10 | 6 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp | 5 | 0 | 1/10 | 7 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp | 5 | 0 | 1/10 | 8 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp | 5 | 0 | 1/10 | 9 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress | 5 | 0 | 1/10 | 10 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp | 5 | 0 | 1/10 | 11 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp | 5 | 0 | 1/10 | 12 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp | 5 | 0 | 1/10 | 242 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | burngas | gas | boolean | | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | 5 | 0 | 1 | 243 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | burngas2 | gas stage 2 | boolean | | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | 5 | 0 | 1 | 244 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr | 5 | 0 | 1/10 | 245 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | fanwork | fan | boolean | | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | 5 | 0 | 1 | 246 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | ignwork | ignition | boolean | | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | 5 | 0 | 1 | 247 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | oilpreheat | oil preheating | boolean | | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | 5 | 0 | 1 | 248 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower | 5 | 0 | 1 | 249 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower | 5 | 0 | 1 | 250 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod | 5 | 0 | 1 | 251 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow | 5 | 0 | 1 | 252 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock | 5 | 0 | 1/10 | 253 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston | 5 | 0 | 1 | 254 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff | 5 | 0 | 1 | 255 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston | 5 | 0 | 1 | 256 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff | 5 | 0 | 1 | 257 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | curveon | heatingcurve on | boolean | | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | 5 | 0 | 1 | 258 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase | 5 | 0 | 1 | 259 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend | 5 | 0 | 1 | 260 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | summertemp | summer temperature | uint8 (>=0<=45) | C | True | number.boiler_summer_temperature | number.boiler_summertemp | 5 | 0 | 1 | 261 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | nofrostmode | nofrost mode | boolean | | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | 5 | 0 | 1 | 262 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp | 5 | 0 | 1 | 263 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | heatingactivated | heating activated | boolean | | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | 5 | 0 | 1 | 13 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp | 5 | 0 | 1 | 14 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | heatingpump | heating pump | boolean | | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | 5 | 0 | 1 | 15 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax | 5 | 0 | 1 | 16 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin | 5 | 0 | 1 | 17 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | 5 | 0 | 1 | 18 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | pumpcharacter | boiler pump characteristic | enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] | | True | select.boiler_boiler_pump_characteristic | select.boiler_pumpcharacter | 5 | 0 | 1 | 19 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay | 5 | 0 | 1 | 20 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | pumpontemp | pump logic temperature | uint8 (>=0<=60) | C | True | number.boiler_pump_logic_temperature | number.boiler_pumpontemp | 5 | 0 | 1 | 21 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow | 5 | 0 | 1 | 22 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow | 5 | 0 | 1 | 23 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | burnstarts | burner starts | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | 5 | 0 | 1 | 24 | 2 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin | 5 | 0 | 1 | 26 | 2 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin | 5 | 0 | 1 | 28 | 2 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin | 5 | 0 | 1 | 30 | 2 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | 5 | 0 | 1 | 32 | 2 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime | 5 | 0 | 1 | 34 | 2 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | lastcode | last error code | string | | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | 5 | 0 | 1 | 36 | 28 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | servicecode | service code | string | | False | sensor.boiler_service_code | sensor.boiler_servicecode | 5 | 0 | 1 | 64 | 2 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | servicecodenumber | service code number | uint16 (>=0<=31999) | | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | 5 | 0 | 1 | 66 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | maintenancemessage | maintenance message | string | | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | 5 | 0 | 1 | 67 | 2 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | maintenance | maintenance scheduled | enum [off|time|date|manual] | | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | 5 | 0 | 1 | 69 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime | 5 | 0 | 1 | 70 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | maintenancedate | next maintenance date | string | | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | 5 | 0 | 1 | 71 | 6 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | emergencyops | emergency operation | boolean | | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | 5 | 0 | 1 | 77 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp | 5 | 0 | 1 | 78 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat | 5 | 0 | 1/10 | 91 | 2 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | meter | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meter | 5 | 9 | 1/10 | 2 | 2 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat | 5 | 0 | 1/10 | 264 | 2 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeter | 5 | 9 | 1/10 | 69 | 2 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 | 5 | 0 | 1/10 | 266 | 2 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrg2 | 5 | 9 | 1/10 | 71 | 2 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | tapactivated | turn on/off | boolean | | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | 5 | 9 | 1 | 28 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp | 5 | 9 | 1 | 29 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp | 5 | 9 | 1 | 30 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow | 5 | 9 | 1 | 31 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus | 5 | 9 | 1 | 32 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff | 5 | 9 | 1 | 33 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle | 5 | 9 | 1 | 34 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp | 5 | 9 | 1/10 | 35 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | 5 | 9 | 1 | 36 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | comfort | comfort | enum [hot|eco|intelligent] | | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | 5 | 9 | 1 | 37 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | comfort1 | comfort mode | enum [high comfort|eco] | | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | 5 | 9 | 1 | 38 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset | 5 | 9 | 1 | 39 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | chargeoptimization | charge optimization | boolean | | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | 5 | 9 | 1 | 40 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower | 5 | 9 | 1 | 41 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp | 5 | 9 | 1 | 42 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | circpump | circulation pump available | boolean | | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | 5 | 9 | 1 | 43 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | chargetype | charging type | enum [chargepump|3-way valve] | | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | 5 | 9 | 1 | 44 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston | 5 | 9 | 1 | 45 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff | 5 | 9 | 1 | 46 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp | 5 | 9 | 1 | 47 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | 5 | 9 | 1 | 48 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | circ | circulation active | boolean | | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | 5 | 9 | 1 | 49 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp | 5 | 9 | 1/10 | 50 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 | 5 | 9 | 1/10 | 51 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow | 5 | 9 | 1/10 | 52 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 | 5 | 9 | 1/10 | 53 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 | 5 | 9 | 1/10 | 54 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | activated | activated | boolean | | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | 5 | 9 | 1 | 55 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | onetime | one time charging | boolean | | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | 5 | 9 | 1 | 56 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | disinfecting | disinfecting | boolean | | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | 5 | 9 | 1 | 57 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | charging | charging | boolean | | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | 5 | 9 | 1 | 58 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | recharging | recharging | boolean | | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | 5 | 9 | 1 | 59 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | tempok | temperature ok | boolean | | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | 5 | 9 | 1 | 60 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | active | active | boolean | | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | 5 | 9 | 1 | 61 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | 3wayvalve | 3-way valve active | boolean | | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | 5 | 9 | 1 | 62 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp | 5 | 9 | 1/10 | 63 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp | 5 | 9 | 1/10 | 64 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | starts | starts | uint24 (>=0<=16777213) | | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | 5 | 9 | 1 | 65 | 2 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm | 5 | 9 | 1 | 67 | 2 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower | 5 | 0 | 1 | 268 | 1 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal | 5 | 0 | 1/100 | 79 | 2 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat | 5 | 0 | 1/100 | 81 | 2 |
Logano GB125/KB195i, Logamatic MC110 | boiler | 133 | nrg | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrg | 5 | 9 | 1/100 | 0 | 2 |
Greenstar 30Ri Compact | boiler | 154 | reset | reset | cmd [-|maintenance|error|history|message] | | True | sensor.boiler_reset | sensor.boiler_reset | 5 | 0 | 1 | 0 | 1 |
Greenstar 30Ri Compact | boiler | 154 | heatingoff | force heating off | boolean | | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | 5 | 0 | 1 | 1 | 1 |
Greenstar 30Ri Compact | boiler | 154 | heatingactive | heating active | boolean | | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | 5 | 0 | 1 | 2 | 1 |
Greenstar 30Ri Compact | boiler | 154 | tapwateractive | tapwater active | boolean | | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | 5 | 0 | 1 | 3 | 1 |
Greenstar 30Ri Compact | boiler | 154 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp | 5 | 0 | 1 | 4 | 1 |
Greenstar 30Ri Compact | boiler | 154 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod | 5 | 0 | 1 | 5 | 1 |
Greenstar 30Ri Compact | boiler | 154 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp | 5 | 0 | 1/10 | 6 | 1 |
Greenstar 30Ri Compact | boiler | 154 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp | 5 | 0 | 1/10 | 7 | 1 |
Greenstar 30Ri Compact | boiler | 154 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp | 5 | 0 | 1/10 | 8 | 1 |
Greenstar 30Ri Compact | boiler | 154 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp | 5 | 0 | 1/10 | 9 | 1 |
Greenstar 30Ri Compact | boiler | 154 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress | 5 | 0 | 1/10 | 10 | 1 |
Greenstar 30Ri Compact | boiler | 154 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp | 5 | 0 | 1/10 | 11 | 1 |
Greenstar 30Ri Compact | boiler | 154 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp | 5 | 0 | 1/10 | 12 | 1 |
Greenstar 30Ri Compact | boiler | 154 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp | 5 | 0 | 1/10 | 242 | 1 |
Greenstar 30Ri Compact | boiler | 154 | burngas | gas | boolean | | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | 5 | 0 | 1 | 243 | 1 |
Greenstar 30Ri Compact | boiler | 154 | burngas2 | gas stage 2 | boolean | | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | 5 | 0 | 1 | 244 | 1 |
Greenstar 30Ri Compact | boiler | 154 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr | 5 | 0 | 1/10 | 245 | 1 |
Greenstar 30Ri Compact | boiler | 154 | fanwork | fan | boolean | | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | 5 | 0 | 1 | 246 | 1 |
Greenstar 30Ri Compact | boiler | 154 | ignwork | ignition | boolean | | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | 5 | 0 | 1 | 247 | 1 |
Greenstar 30Ri Compact | boiler | 154 | oilpreheat | oil preheating | boolean | | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | 5 | 0 | 1 | 248 | 1 |
Greenstar 30Ri Compact | boiler | 154 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower | 5 | 0 | 1 | 249 | 1 |
Greenstar 30Ri Compact | boiler | 154 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower | 5 | 0 | 1 | 250 | 1 |
Greenstar 30Ri Compact | boiler | 154 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod | 5 | 0 | 1 | 251 | 1 |
Greenstar 30Ri Compact | boiler | 154 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow | 5 | 0 | 1 | 252 | 1 |
Greenstar 30Ri Compact | boiler | 154 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock | 5 | 0 | 1/10 | 253 | 1 |
Greenstar 30Ri Compact | boiler | 154 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston | 5 | 0 | 1 | 254 | 1 |
Greenstar 30Ri Compact | boiler | 154 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff | 5 | 0 | 1 | 255 | 1 |
Greenstar 30Ri Compact | boiler | 154 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston | 5 | 0 | 1 | 256 | 1 |
Greenstar 30Ri Compact | boiler | 154 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff | 5 | 0 | 1 | 257 | 1 |
Greenstar 30Ri Compact | boiler | 154 | curveon | heatingcurve on | boolean | | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | 5 | 0 | 1 | 258 | 1 |
Greenstar 30Ri Compact | boiler | 154 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase | 5 | 0 | 1 | 259 | 1 |
Greenstar 30Ri Compact | boiler | 154 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend | 5 | 0 | 1 | 260 | 1 |
Greenstar 30Ri Compact | boiler | 154 | summertemp | summer temperature | uint8 (>=0<=45) | C | True | number.boiler_summer_temperature | number.boiler_summertemp | 5 | 0 | 1 | 261 | 1 |
Greenstar 30Ri Compact | boiler | 154 | nofrostmode | nofrost mode | boolean | | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | 5 | 0 | 1 | 262 | 1 |
Greenstar 30Ri Compact | boiler | 154 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp | 5 | 0 | 1 | 263 | 1 |
Greenstar 30Ri Compact | boiler | 154 | heatingactivated | heating activated | boolean | | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | 5 | 0 | 1 | 13 | 1 |
Greenstar 30Ri Compact | boiler | 154 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp | 5 | 0 | 1 | 14 | 1 |
Greenstar 30Ri Compact | boiler | 154 | heatingpump | heating pump | boolean | | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | 5 | 0 | 1 | 15 | 1 |
Greenstar 30Ri Compact | boiler | 154 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax | 5 | 0 | 1 | 16 | 1 |
Greenstar 30Ri Compact | boiler | 154 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin | 5 | 0 | 1 | 17 | 1 |
Greenstar 30Ri Compact | boiler | 154 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | 5 | 0 | 1 | 18 | 1 |
Greenstar 30Ri Compact | boiler | 154 | pumpcharacter | boiler pump characteristic | enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] | | True | select.boiler_boiler_pump_characteristic | select.boiler_pumpcharacter | 5 | 0 | 1 | 19 | 1 |
Greenstar 30Ri Compact | boiler | 154 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay | 5 | 0 | 1 | 20 | 1 |
Greenstar 30Ri Compact | boiler | 154 | pumpontemp | pump logic temperature | uint8 (>=0<=60) | C | True | number.boiler_pump_logic_temperature | number.boiler_pumpontemp | 5 | 0 | 1 | 21 | 1 |
Greenstar 30Ri Compact | boiler | 154 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow | 5 | 0 | 1 | 22 | 1 |
Greenstar 30Ri Compact | boiler | 154 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow | 5 | 0 | 1 | 23 | 1 |
Greenstar 30Ri Compact | boiler | 154 | burnstarts | burner starts | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | 5 | 0 | 1 | 24 | 2 |
Greenstar 30Ri Compact | boiler | 154 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin | 5 | 0 | 1 | 26 | 2 |
Greenstar 30Ri Compact | boiler | 154 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin | 5 | 0 | 1 | 28 | 2 |
Greenstar 30Ri Compact | boiler | 154 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin | 5 | 0 | 1 | 30 | 2 |
Greenstar 30Ri Compact | boiler | 154 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | 5 | 0 | 1 | 32 | 2 |
Greenstar 30Ri Compact | boiler | 154 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime | 5 | 0 | 1 | 34 | 2 |
Greenstar 30Ri Compact | boiler | 154 | lastcode | last error code | string | | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | 5 | 0 | 1 | 36 | 28 |
Greenstar 30Ri Compact | boiler | 154 | servicecode | service code | string | | False | sensor.boiler_service_code | sensor.boiler_servicecode | 5 | 0 | 1 | 64 | 2 |
Greenstar 30Ri Compact | boiler | 154 | servicecodenumber | service code number | uint16 (>=0<=31999) | | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | 5 | 0 | 1 | 66 | 1 |
Greenstar 30Ri Compact | boiler | 154 | maintenancemessage | maintenance message | string | | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | 5 | 0 | 1 | 67 | 2 |
Greenstar 30Ri Compact | boiler | 154 | maintenance | maintenance scheduled | enum [off|time|date|manual] | | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | 5 | 0 | 1 | 69 | 1 |
Greenstar 30Ri Compact | boiler | 154 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime | 5 | 0 | 1 | 70 | 1 |
Greenstar 30Ri Compact | boiler | 154 | maintenancedate | next maintenance date | string | | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | 5 | 0 | 1 | 71 | 6 |
Greenstar 30Ri Compact | boiler | 154 | emergencyops | emergency operation | boolean | | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | 5 | 0 | 1 | 77 | 1 |
Greenstar 30Ri Compact | boiler | 154 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp | 5 | 0 | 1 | 78 | 1 |
Greenstar 30Ri Compact | boiler | 154 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat | 5 | 0 | 1/10 | 91 | 2 |
Greenstar 30Ri Compact | boiler | 154 | meter | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meter | 5 | 9 | 1/10 | 2 | 2 |
Greenstar 30Ri Compact | boiler | 154 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat | 5 | 0 | 1/10 | 264 | 2 |
Greenstar 30Ri Compact | boiler | 154 | gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeter | 5 | 9 | 1/10 | 69 | 2 |
Greenstar 30Ri Compact | boiler | 154 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 | 5 | 0 | 1/10 | 266 | 2 |
Greenstar 30Ri Compact | boiler | 154 | nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrg2 | 5 | 9 | 1/10 | 71 | 2 |
Greenstar 30Ri Compact | boiler | 154 | tapactivated | turn on/off | boolean | | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | 5 | 9 | 1 | 28 | 1 |
Greenstar 30Ri Compact | boiler | 154 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp | 5 | 9 | 1 | 29 | 1 |
Greenstar 30Ri Compact | boiler | 154 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp | 5 | 9 | 1 | 30 | 1 |
Greenstar 30Ri Compact | boiler | 154 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow | 5 | 9 | 1 | 31 | 1 |
Greenstar 30Ri Compact | boiler | 154 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus | 5 | 9 | 1 | 32 | 1 |
Greenstar 30Ri Compact | boiler | 154 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff | 5 | 9 | 1 | 33 | 1 |
Greenstar 30Ri Compact | boiler | 154 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle | 5 | 9 | 1 | 34 | 1 |
Greenstar 30Ri Compact | boiler | 154 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp | 5 | 9 | 1/10 | 35 | 1 |
Greenstar 30Ri Compact | boiler | 154 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | 5 | 9 | 1 | 36 | 1 |
Greenstar 30Ri Compact | boiler | 154 | comfort | comfort | enum [hot|eco|intelligent] | | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | 5 | 9 | 1 | 37 | 1 |
Greenstar 30Ri Compact | boiler | 154 | comfort1 | comfort mode | enum [high comfort|eco] | | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | 5 | 9 | 1 | 38 | 1 |
Greenstar 30Ri Compact | boiler | 154 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset | 5 | 9 | 1 | 39 | 1 |
Greenstar 30Ri Compact | boiler | 154 | chargeoptimization | charge optimization | boolean | | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | 5 | 9 | 1 | 40 | 1 |
Greenstar 30Ri Compact | boiler | 154 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower | 5 | 9 | 1 | 41 | 1 |
Greenstar 30Ri Compact | boiler | 154 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp | 5 | 9 | 1 | 42 | 1 |
Greenstar 30Ri Compact | boiler | 154 | circpump | circulation pump available | boolean | | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | 5 | 9 | 1 | 43 | 1 |
Greenstar 30Ri Compact | boiler | 154 | chargetype | charging type | enum [chargepump|3-way valve] | | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | 5 | 9 | 1 | 44 | 1 |
Greenstar 30Ri Compact | boiler | 154 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston | 5 | 9 | 1 | 45 | 1 |
Greenstar 30Ri Compact | boiler | 154 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff | 5 | 9 | 1 | 46 | 1 |
Greenstar 30Ri Compact | boiler | 154 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp | 5 | 9 | 1 | 47 | 1 |
Greenstar 30Ri Compact | boiler | 154 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | 5 | 9 | 1 | 48 | 1 |
Greenstar 30Ri Compact | boiler | 154 | circ | circulation active | boolean | | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | 5 | 9 | 1 | 49 | 1 |
Greenstar 30Ri Compact | boiler | 154 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp | 5 | 9 | 1/10 | 50 | 1 |
Greenstar 30Ri Compact | boiler | 154 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 | 5 | 9 | 1/10 | 51 | 1 |
Greenstar 30Ri Compact | boiler | 154 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow | 5 | 9 | 1/10 | 52 | 1 |
Greenstar 30Ri Compact | boiler | 154 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 | 5 | 9 | 1/10 | 53 | 1 |
Greenstar 30Ri Compact | boiler | 154 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 | 5 | 9 | 1/10 | 54 | 1 |
Greenstar 30Ri Compact | boiler | 154 | activated | activated | boolean | | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | 5 | 9 | 1 | 55 | 1 |
Greenstar 30Ri Compact | boiler | 154 | onetime | one time charging | boolean | | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | 5 | 9 | 1 | 56 | 1 |
Greenstar 30Ri Compact | boiler | 154 | disinfecting | disinfecting | boolean | | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | 5 | 9 | 1 | 57 | 1 |
Greenstar 30Ri Compact | boiler | 154 | charging | charging | boolean | | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | 5 | 9 | 1 | 58 | 1 |
Greenstar 30Ri Compact | boiler | 154 | recharging | recharging | boolean | | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | 5 | 9 | 1 | 59 | 1 |
Greenstar 30Ri Compact | boiler | 154 | tempok | temperature ok | boolean | | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | 5 | 9 | 1 | 60 | 1 |
Greenstar 30Ri Compact | boiler | 154 | active | active | boolean | | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | 5 | 9 | 1 | 61 | 1 |
Greenstar 30Ri Compact | boiler | 154 | 3wayvalve | 3-way valve active | boolean | | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | 5 | 9 | 1 | 62 | 1 |
Greenstar 30Ri Compact | boiler | 154 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp | 5 | 9 | 1/10 | 63 | 1 |
Greenstar 30Ri Compact | boiler | 154 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp | 5 | 9 | 1/10 | 64 | 1 |
Greenstar 30Ri Compact | boiler | 154 | starts | starts | uint24 (>=0<=16777213) | | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | 5 | 9 | 1 | 65 | 2 |
Greenstar 30Ri Compact | boiler | 154 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm | 5 | 9 | 1 | 67 | 2 |
Greenstar 30Ri Compact | boiler | 154 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower | 5 | 0 | 1 | 268 | 1 |
Greenstar 30Ri Compact | boiler | 154 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal | 5 | 0 | 1/100 | 79 | 2 |
Greenstar 30Ri Compact | boiler | 154 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat | 5 | 0 | 1/100 | 81 | 2 |
Greenstar 30Ri Compact | boiler | 154 | nrg | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrg | 5 | 9 | 1/100 | 0 | 2 |
Cerapur Aero | boiler | 167 | reset | reset | cmd [-|maintenance|error|history|message] | | True | sensor.boiler_reset | sensor.boiler_reset | 5 | 0 | 1 | 0 | 1 |
Cerapur Aero | boiler | 167 | heatingoff | force heating off | boolean | | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | 5 | 0 | 1 | 1 | 1 |
Cerapur Aero | boiler | 167 | heatingactive | heating active | boolean | | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | 5 | 0 | 1 | 2 | 1 |
Cerapur Aero | boiler | 167 | tapwateractive | tapwater active | boolean | | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | 5 | 0 | 1 | 3 | 1 |
Cerapur Aero | boiler | 167 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp | 5 | 0 | 1 | 4 | 1 |
Cerapur Aero | boiler | 167 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod | 5 | 0 | 1 | 5 | 1 |
Cerapur Aero | boiler | 167 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp | 5 | 0 | 1/10 | 6 | 1 |
Cerapur Aero | boiler | 167 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp | 5 | 0 | 1/10 | 7 | 1 |
Cerapur Aero | boiler | 167 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp | 5 | 0 | 1/10 | 8 | 1 |
Cerapur Aero | boiler | 167 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp | 5 | 0 | 1/10 | 9 | 1 |
Cerapur Aero | boiler | 167 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress | 5 | 0 | 1/10 | 10 | 1 |
Cerapur Aero | boiler | 167 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp | 5 | 0 | 1/10 | 11 | 1 |
Cerapur Aero | boiler | 167 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp | 5 | 0 | 1/10 | 12 | 1 |
Cerapur Aero | boiler | 167 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp | 5 | 0 | 1/10 | 242 | 1 |
Cerapur Aero | boiler | 167 | burngas | gas | boolean | | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | 5 | 0 | 1 | 243 | 1 |
Cerapur Aero | boiler | 167 | burngas2 | gas stage 2 | boolean | | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | 5 | 0 | 1 | 244 | 1 |
Cerapur Aero | boiler | 167 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr | 5 | 0 | 1/10 | 245 | 1 |
Cerapur Aero | boiler | 167 | fanwork | fan | boolean | | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | 5 | 0 | 1 | 246 | 1 |
Cerapur Aero | boiler | 167 | ignwork | ignition | boolean | | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | 5 | 0 | 1 | 247 | 1 |
Cerapur Aero | boiler | 167 | oilpreheat | oil preheating | boolean | | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | 5 | 0 | 1 | 248 | 1 |
Cerapur Aero | boiler | 167 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower | 5 | 0 | 1 | 249 | 1 |
Cerapur Aero | boiler | 167 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower | 5 | 0 | 1 | 250 | 1 |
Cerapur Aero | boiler | 167 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod | 5 | 0 | 1 | 251 | 1 |
Cerapur Aero | boiler | 167 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow | 5 | 0 | 1 | 252 | 1 |
Cerapur Aero | boiler | 167 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock | 5 | 0 | 1/10 | 253 | 1 |
Cerapur Aero | boiler | 167 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston | 5 | 0 | 1 | 254 | 1 |
Cerapur Aero | boiler | 167 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff | 5 | 0 | 1 | 255 | 1 |
Cerapur Aero | boiler | 167 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston | 5 | 0 | 1 | 256 | 1 |
Cerapur Aero | boiler | 167 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff | 5 | 0 | 1 | 257 | 1 |
Cerapur Aero | boiler | 167 | curveon | heatingcurve on | boolean | | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | 5 | 0 | 1 | 258 | 1 |
Cerapur Aero | boiler | 167 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase | 5 | 0 | 1 | 259 | 1 |
Cerapur Aero | boiler | 167 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend | 5 | 0 | 1 | 260 | 1 |
Cerapur Aero | boiler | 167 | summertemp | summer temperature | uint8 (>=0<=45) | C | True | number.boiler_summer_temperature | number.boiler_summertemp | 5 | 0 | 1 | 261 | 1 |
Cerapur Aero | boiler | 167 | nofrostmode | nofrost mode | boolean | | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | 5 | 0 | 1 | 262 | 1 |
Cerapur Aero | boiler | 167 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp | 5 | 0 | 1 | 263 | 1 |
Cerapur Aero | boiler | 167 | heatingactivated | heating activated | boolean | | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | 5 | 0 | 1 | 13 | 1 |
Cerapur Aero | boiler | 167 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp | 5 | 0 | 1 | 14 | 1 |
Cerapur Aero | boiler | 167 | heatingpump | heating pump | boolean | | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | 5 | 0 | 1 | 15 | 1 |
Cerapur Aero | boiler | 167 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax | 5 | 0 | 1 | 16 | 1 |
Cerapur Aero | boiler | 167 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin | 5 | 0 | 1 | 17 | 1 |
Cerapur Aero | boiler | 167 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | 5 | 0 | 1 | 18 | 1 |
Cerapur Aero | boiler | 167 | pumpcharacter | boiler pump characteristic | enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] | | True | select.boiler_boiler_pump_characteristic | select.boiler_pumpcharacter | 5 | 0 | 1 | 19 | 1 |
Cerapur Aero | boiler | 167 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay | 5 | 0 | 1 | 20 | 1 |
Cerapur Aero | boiler | 167 | pumpontemp | pump logic temperature | uint8 (>=0<=60) | C | True | number.boiler_pump_logic_temperature | number.boiler_pumpontemp | 5 | 0 | 1 | 21 | 1 |
Cerapur Aero | boiler | 167 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow | 5 | 0 | 1 | 22 | 1 |
Cerapur Aero | boiler | 167 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow | 5 | 0 | 1 | 23 | 1 |
Cerapur Aero | boiler | 167 | burnstarts | burner starts | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | 5 | 0 | 1 | 24 | 2 |
Cerapur Aero | boiler | 167 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin | 5 | 0 | 1 | 26 | 2 |
Cerapur Aero | boiler | 167 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin | 5 | 0 | 1 | 28 | 2 |
Cerapur Aero | boiler | 167 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin | 5 | 0 | 1 | 30 | 2 |
Cerapur Aero | boiler | 167 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | 5 | 0 | 1 | 32 | 2 |
Cerapur Aero | boiler | 167 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime | 5 | 0 | 1 | 34 | 2 |
Cerapur Aero | boiler | 167 | lastcode | last error code | string | | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | 5 | 0 | 1 | 36 | 28 |
Cerapur Aero | boiler | 167 | servicecode | service code | string | | False | sensor.boiler_service_code | sensor.boiler_servicecode | 5 | 0 | 1 | 64 | 2 |
Cerapur Aero | boiler | 167 | servicecodenumber | service code number | uint16 (>=0<=31999) | | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | 5 | 0 | 1 | 66 | 1 |
Cerapur Aero | boiler | 167 | maintenancemessage | maintenance message | string | | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | 5 | 0 | 1 | 67 | 2 |
Cerapur Aero | boiler | 167 | maintenance | maintenance scheduled | enum [off|time|date|manual] | | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | 5 | 0 | 1 | 69 | 1 |
Cerapur Aero | boiler | 167 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime | 5 | 0 | 1 | 70 | 1 |
Cerapur Aero | boiler | 167 | maintenancedate | next maintenance date | string | | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | 5 | 0 | 1 | 71 | 6 |
Cerapur Aero | boiler | 167 | emergencyops | emergency operation | boolean | | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | 5 | 0 | 1 | 77 | 1 |
Cerapur Aero | boiler | 167 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp | 5 | 0 | 1 | 78 | 1 |
Cerapur Aero | boiler | 167 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat | 5 | 0 | 1/10 | 91 | 2 |
Cerapur Aero | boiler | 167 | meter | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meter | 5 | 9 | 1/10 | 2 | 2 |
Cerapur Aero | boiler | 167 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat | 5 | 0 | 1/10 | 264 | 2 |
Cerapur Aero | boiler | 167 | gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeter | 5 | 9 | 1/10 | 69 | 2 |
Cerapur Aero | boiler | 167 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 | 5 | 0 | 1/10 | 266 | 2 |
Cerapur Aero | boiler | 167 | nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrg2 | 5 | 9 | 1/10 | 71 | 2 |
Cerapur Aero | boiler | 167 | tapactivated | turn on/off | boolean | | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | 5 | 9 | 1 | 28 | 1 |
Cerapur Aero | boiler | 167 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp | 5 | 9 | 1 | 29 | 1 |
Cerapur Aero | boiler | 167 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp | 5 | 9 | 1 | 30 | 1 |
Cerapur Aero | boiler | 167 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow | 5 | 9 | 1 | 31 | 1 |
Cerapur Aero | boiler | 167 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus | 5 | 9 | 1 | 32 | 1 |
Cerapur Aero | boiler | 167 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff | 5 | 9 | 1 | 33 | 1 |
Cerapur Aero | boiler | 167 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle | 5 | 9 | 1 | 34 | 1 |
Cerapur Aero | boiler | 167 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp | 5 | 9 | 1/10 | 35 | 1 |
Cerapur Aero | boiler | 167 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | 5 | 9 | 1 | 36 | 1 |
Cerapur Aero | boiler | 167 | comfort | comfort | enum [hot|eco|intelligent] | | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | 5 | 9 | 1 | 37 | 1 |
Cerapur Aero | boiler | 167 | comfort1 | comfort mode | enum [high comfort|eco] | | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | 5 | 9 | 1 | 38 | 1 |
Cerapur Aero | boiler | 167 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset | 5 | 9 | 1 | 39 | 1 |
Cerapur Aero | boiler | 167 | chargeoptimization | charge optimization | boolean | | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | 5 | 9 | 1 | 40 | 1 |
Cerapur Aero | boiler | 167 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower | 5 | 9 | 1 | 41 | 1 |
Cerapur Aero | boiler | 167 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp | 5 | 9 | 1 | 42 | 1 |
Cerapur Aero | boiler | 167 | circpump | circulation pump available | boolean | | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | 5 | 9 | 1 | 43 | 1 |
Cerapur Aero | boiler | 167 | chargetype | charging type | enum [chargepump|3-way valve] | | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | 5 | 9 | 1 | 44 | 1 |
Cerapur Aero | boiler | 167 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston | 5 | 9 | 1 | 45 | 1 |
Cerapur Aero | boiler | 167 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff | 5 | 9 | 1 | 46 | 1 |
Cerapur Aero | boiler | 167 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp | 5 | 9 | 1 | 47 | 1 |
Cerapur Aero | boiler | 167 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | 5 | 9 | 1 | 48 | 1 |
Cerapur Aero | boiler | 167 | circ | circulation active | boolean | | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | 5 | 9 | 1 | 49 | 1 |
Cerapur Aero | boiler | 167 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp | 5 | 9 | 1/10 | 50 | 1 |
Cerapur Aero | boiler | 167 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 | 5 | 9 | 1/10 | 51 | 1 |
Cerapur Aero | boiler | 167 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow | 5 | 9 | 1/10 | 52 | 1 |
Cerapur Aero | boiler | 167 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 | 5 | 9 | 1/10 | 53 | 1 |
Cerapur Aero | boiler | 167 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 | 5 | 9 | 1/10 | 54 | 1 |
Cerapur Aero | boiler | 167 | activated | activated | boolean | | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | 5 | 9 | 1 | 55 | 1 |
Cerapur Aero | boiler | 167 | onetime | one time charging | boolean | | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | 5 | 9 | 1 | 56 | 1 |
Cerapur Aero | boiler | 167 | disinfecting | disinfecting | boolean | | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | 5 | 9 | 1 | 57 | 1 |
Cerapur Aero | boiler | 167 | charging | charging | boolean | | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | 5 | 9 | 1 | 58 | 1 |
Cerapur Aero | boiler | 167 | recharging | recharging | boolean | | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | 5 | 9 | 1 | 59 | 1 |
Cerapur Aero | boiler | 167 | tempok | temperature ok | boolean | | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | 5 | 9 | 1 | 60 | 1 |
Cerapur Aero | boiler | 167 | active | active | boolean | | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | 5 | 9 | 1 | 61 | 1 |
Cerapur Aero | boiler | 167 | 3wayvalve | 3-way valve active | boolean | | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | 5 | 9 | 1 | 62 | 1 |
Cerapur Aero | boiler | 167 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp | 5 | 9 | 1/10 | 63 | 1 |
Cerapur Aero | boiler | 167 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp | 5 | 9 | 1/10 | 64 | 1 |
Cerapur Aero | boiler | 167 | starts | starts | uint24 (>=0<=16777213) | | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | 5 | 9 | 1 | 65 | 2 |
Cerapur Aero | boiler | 167 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm | 5 | 9 | 1 | 67 | 2 |
Cerapur Aero | boiler | 167 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower | 5 | 0 | 1 | 268 | 1 |
Cerapur Aero | boiler | 167 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal | 5 | 0 | 1/100 | 79 | 2 |
Cerapur Aero | boiler | 167 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat | 5 | 0 | 1/100 | 81 | 2 |
Cerapur Aero | boiler | 167 | nrg | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrg | 5 | 9 | 1/100 | 0 | 2 |
Hybrid Heatpump | boiler | 168 | reset | reset | cmd [-|maintenance|error|history|message] | | True | sensor.boiler_reset | sensor.boiler_reset | 5 | 0 | 1 | 0 | 1 |
Hybrid Heatpump | boiler | 168 | heatingoff | force heating off | boolean | | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | 5 | 0 | 1 | 1 | 1 |
Hybrid Heatpump | boiler | 168 | heatingactive | heating active | boolean | | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | 5 | 0 | 1 | 2 | 1 |
Hybrid Heatpump | boiler | 168 | tapwateractive | tapwater active | boolean | | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | 5 | 0 | 1 | 3 | 1 |
Hybrid Heatpump | boiler | 168 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp | 5 | 0 | 1 | 4 | 1 |
Hybrid Heatpump | boiler | 168 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod | 5 | 0 | 1 | 5 | 1 |
Hybrid Heatpump | boiler | 168 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp | 5 | 0 | 1/10 | 6 | 1 |
Hybrid Heatpump | boiler | 168 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp | 5 | 0 | 1/10 | 7 | 1 |
Hybrid Heatpump | boiler | 168 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp | 5 | 0 | 1/10 | 8 | 1 |
Hybrid Heatpump | boiler | 168 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp | 5 | 0 | 1/10 | 9 | 1 |
Hybrid Heatpump | boiler | 168 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress | 5 | 0 | 1/10 | 10 | 1 |
Hybrid Heatpump | boiler | 168 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp | 5 | 0 | 1/10 | 11 | 1 |
Hybrid Heatpump | boiler | 168 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp | 5 | 0 | 1/10 | 12 | 1 |
Hybrid Heatpump | boiler | 168 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp | 5 | 0 | 1/10 | 242 | 1 |
Hybrid Heatpump | boiler | 168 | burngas | gas | boolean | | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | 5 | 0 | 1 | 243 | 1 |
Hybrid Heatpump | boiler | 168 | burngas2 | gas stage 2 | boolean | | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | 5 | 0 | 1 | 244 | 1 |
Hybrid Heatpump | boiler | 168 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr | 5 | 0 | 1/10 | 245 | 1 |
Hybrid Heatpump | boiler | 168 | fanwork | fan | boolean | | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | 5 | 0 | 1 | 246 | 1 |
Hybrid Heatpump | boiler | 168 | ignwork | ignition | boolean | | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | 5 | 0 | 1 | 247 | 1 |
Hybrid Heatpump | boiler | 168 | oilpreheat | oil preheating | boolean | | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | 5 | 0 | 1 | 248 | 1 |
Hybrid Heatpump | boiler | 168 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower | 5 | 0 | 1 | 249 | 1 |
Hybrid Heatpump | boiler | 168 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower | 5 | 0 | 1 | 250 | 1 |
Hybrid Heatpump | boiler | 168 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod | 5 | 0 | 1 | 251 | 1 |
Hybrid Heatpump | boiler | 168 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow | 5 | 0 | 1 | 252 | 1 |
Hybrid Heatpump | boiler | 168 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock | 5 | 0 | 1/10 | 253 | 1 |
Hybrid Heatpump | boiler | 168 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston | 5 | 0 | 1 | 254 | 1 |
Hybrid Heatpump | boiler | 168 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff | 5 | 0 | 1 | 255 | 1 |
Hybrid Heatpump | boiler | 168 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston | 5 | 0 | 1 | 256 | 1 |
Hybrid Heatpump | boiler | 168 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff | 5 | 0 | 1 | 257 | 1 |
Hybrid Heatpump | boiler | 168 | curveon | heatingcurve on | boolean | | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | 5 | 0 | 1 | 258 | 1 |
Hybrid Heatpump | boiler | 168 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase | 5 | 0 | 1 | 259 | 1 |
Hybrid Heatpump | boiler | 168 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend | 5 | 0 | 1 | 260 | 1 |
Hybrid Heatpump | boiler | 168 | summertemp | summer temperature | uint8 (>=0<=45) | C | True | number.boiler_summer_temperature | number.boiler_summertemp | 5 | 0 | 1 | 261 | 1 |
Hybrid Heatpump | boiler | 168 | nofrostmode | nofrost mode | boolean | | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | 5 | 0 | 1 | 262 | 1 |
Hybrid Heatpump | boiler | 168 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp | 5 | 0 | 1 | 263 | 1 |
Hybrid Heatpump | boiler | 168 | heatingactivated | heating activated | boolean | | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | 5 | 0 | 1 | 13 | 1 |
Hybrid Heatpump | boiler | 168 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp | 5 | 0 | 1 | 14 | 1 |
Hybrid Heatpump | boiler | 168 | heatingpump | heating pump | boolean | | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | 5 | 0 | 1 | 15 | 1 |
Hybrid Heatpump | boiler | 168 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax | 5 | 0 | 1 | 16 | 1 |
Hybrid Heatpump | boiler | 168 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin | 5 | 0 | 1 | 17 | 1 |
Hybrid Heatpump | boiler | 168 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | 5 | 0 | 1 | 18 | 1 |
Hybrid Heatpump | boiler | 168 | pumpcharacter | boiler pump characteristic | enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] | | True | select.boiler_boiler_pump_characteristic | select.boiler_pumpcharacter | 5 | 0 | 1 | 19 | 1 |
Hybrid Heatpump | boiler | 168 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay | 5 | 0 | 1 | 20 | 1 |
Hybrid Heatpump | boiler | 168 | pumpontemp | pump logic temperature | uint8 (>=0<=60) | C | True | number.boiler_pump_logic_temperature | number.boiler_pumpontemp | 5 | 0 | 1 | 21 | 1 |
Hybrid Heatpump | boiler | 168 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow | 5 | 0 | 1 | 22 | 1 |
Hybrid Heatpump | boiler | 168 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow | 5 | 0 | 1 | 23 | 1 |
Hybrid Heatpump | boiler | 168 | burnstarts | burner starts | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | 5 | 0 | 1 | 24 | 2 |
Hybrid Heatpump | boiler | 168 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin | 5 | 0 | 1 | 26 | 2 |
Hybrid Heatpump | boiler | 168 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin | 5 | 0 | 1 | 28 | 2 |
Hybrid Heatpump | boiler | 168 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin | 5 | 0 | 1 | 30 | 2 |
Hybrid Heatpump | boiler | 168 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | 5 | 0 | 1 | 32 | 2 |
Hybrid Heatpump | boiler | 168 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime | 5 | 0 | 1 | 34 | 2 |
Hybrid Heatpump | boiler | 168 | lastcode | last error code | string | | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | 5 | 0 | 1 | 36 | 28 |
Hybrid Heatpump | boiler | 168 | servicecode | service code | string | | False | sensor.boiler_service_code | sensor.boiler_servicecode | 5 | 0 | 1 | 64 | 2 |
Hybrid Heatpump | boiler | 168 | servicecodenumber | service code number | uint16 (>=0<=31999) | | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | 5 | 0 | 1 | 66 | 1 |
Hybrid Heatpump | boiler | 168 | maintenancemessage | maintenance message | string | | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | 5 | 0 | 1 | 67 | 2 |
Hybrid Heatpump | boiler | 168 | maintenance | maintenance scheduled | enum [off|time|date|manual] | | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | 5 | 0 | 1 | 69 | 1 |
Hybrid Heatpump | boiler | 168 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime | 5 | 0 | 1 | 70 | 1 |
Hybrid Heatpump | boiler | 168 | maintenancedate | next maintenance date | string | | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | 5 | 0 | 1 | 71 | 6 |
Hybrid Heatpump | boiler | 168 | emergencyops | emergency operation | boolean | | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | 5 | 0 | 1 | 77 | 1 |
Hybrid Heatpump | boiler | 168 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp | 5 | 0 | 1 | 78 | 1 |
Hybrid Heatpump | boiler | 168 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat | 5 | 0 | 1/10 | 91 | 2 |
Hybrid Heatpump | boiler | 168 | meter | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meter | 5 | 9 | 1/10 | 2 | 2 |
Hybrid Heatpump | boiler | 168 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat | 5 | 0 | 1/10 | 264 | 2 |
Hybrid Heatpump | boiler | 168 | gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeter | 5 | 9 | 1/10 | 69 | 2 |
Hybrid Heatpump | boiler | 168 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 | 5 | 0 | 1/10 | 266 | 2 |
Hybrid Heatpump | boiler | 168 | nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrg2 | 5 | 9 | 1/10 | 71 | 2 |
Hybrid Heatpump | boiler | 168 | tapactivated | turn on/off | boolean | | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | 5 | 9 | 1 | 28 | 1 |
Hybrid Heatpump | boiler | 168 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp | 5 | 9 | 1 | 29 | 1 |
Hybrid Heatpump | boiler | 168 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp | 5 | 9 | 1 | 30 | 1 |
Hybrid Heatpump | boiler | 168 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow | 5 | 9 | 1 | 31 | 1 |
Hybrid Heatpump | boiler | 168 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus | 5 | 9 | 1 | 32 | 1 |
Hybrid Heatpump | boiler | 168 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff | 5 | 9 | 1 | 33 | 1 |
Hybrid Heatpump | boiler | 168 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle | 5 | 9 | 1 | 34 | 1 |
Hybrid Heatpump | boiler | 168 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp | 5 | 9 | 1/10 | 35 | 1 |
Hybrid Heatpump | boiler | 168 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | 5 | 9 | 1 | 36 | 1 |
Hybrid Heatpump | boiler | 168 | comfort | comfort | enum [hot|eco|intelligent] | | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | 5 | 9 | 1 | 37 | 1 |
Hybrid Heatpump | boiler | 168 | comfort1 | comfort mode | enum [high comfort|eco] | | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | 5 | 9 | 1 | 38 | 1 |
Hybrid Heatpump | boiler | 168 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset | 5 | 9 | 1 | 39 | 1 |
Hybrid Heatpump | boiler | 168 | chargeoptimization | charge optimization | boolean | | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | 5 | 9 | 1 | 40 | 1 |
Hybrid Heatpump | boiler | 168 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower | 5 | 9 | 1 | 41 | 1 |
Hybrid Heatpump | boiler | 168 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp | 5 | 9 | 1 | 42 | 1 |
Hybrid Heatpump | boiler | 168 | circpump | circulation pump available | boolean | | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | 5 | 9 | 1 | 43 | 1 |
Hybrid Heatpump | boiler | 168 | chargetype | charging type | enum [chargepump|3-way valve] | | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | 5 | 9 | 1 | 44 | 1 |
Hybrid Heatpump | boiler | 168 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston | 5 | 9 | 1 | 45 | 1 |
Hybrid Heatpump | boiler | 168 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff | 5 | 9 | 1 | 46 | 1 |
Hybrid Heatpump | boiler | 168 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp | 5 | 9 | 1 | 47 | 1 |
Hybrid Heatpump | boiler | 168 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | 5 | 9 | 1 | 48 | 1 |
Hybrid Heatpump | boiler | 168 | circ | circulation active | boolean | | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | 5 | 9 | 1 | 49 | 1 |
Hybrid Heatpump | boiler | 168 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp | 5 | 9 | 1/10 | 50 | 1 |
Hybrid Heatpump | boiler | 168 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 | 5 | 9 | 1/10 | 51 | 1 |
Hybrid Heatpump | boiler | 168 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow | 5 | 9 | 1/10 | 52 | 1 |
Hybrid Heatpump | boiler | 168 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 | 5 | 9 | 1/10 | 53 | 1 |
Hybrid Heatpump | boiler | 168 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 | 5 | 9 | 1/10 | 54 | 1 |
Hybrid Heatpump | boiler | 168 | activated | activated | boolean | | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | 5 | 9 | 1 | 55 | 1 |
Hybrid Heatpump | boiler | 168 | onetime | one time charging | boolean | | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | 5 | 9 | 1 | 56 | 1 |
Hybrid Heatpump | boiler | 168 | disinfecting | disinfecting | boolean | | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | 5 | 9 | 1 | 57 | 1 |
Hybrid Heatpump | boiler | 168 | charging | charging | boolean | | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | 5 | 9 | 1 | 58 | 1 |
Hybrid Heatpump | boiler | 168 | recharging | recharging | boolean | | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | 5 | 9 | 1 | 59 | 1 |
Hybrid Heatpump | boiler | 168 | tempok | temperature ok | boolean | | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | 5 | 9 | 1 | 60 | 1 |
Hybrid Heatpump | boiler | 168 | active | active | boolean | | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | 5 | 9 | 1 | 61 | 1 |
Hybrid Heatpump | boiler | 168 | 3wayvalve | 3-way valve active | boolean | | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | 5 | 9 | 1 | 62 | 1 |
Hybrid Heatpump | boiler | 168 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp | 5 | 9 | 1/10 | 63 | 1 |
Hybrid Heatpump | boiler | 168 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp | 5 | 9 | 1/10 | 64 | 1 |
Hybrid Heatpump | boiler | 168 | starts | starts | uint24 (>=0<=16777213) | | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | 5 | 9 | 1 | 65 | 2 |
Hybrid Heatpump | boiler | 168 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm | 5 | 9 | 1 | 67 | 2 |
Hybrid Heatpump | boiler | 168 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower | 5 | 0 | 1 | 268 | 1 |
Hybrid Heatpump | boiler | 168 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal | 5 | 0 | 1/100 | 79 | 2 |
Hybrid Heatpump | boiler | 168 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat | 5 | 0 | 1/100 | 81 | 2 |
Hybrid Heatpump | boiler | 168 | nrg | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrg | 5 | 9 | 1/100 | 0 | 2 |
Logano GB212 | boiler | 170 | reset | reset | cmd [-|maintenance|error|history|message] | | True | sensor.boiler_reset | sensor.boiler_reset | 5 | 0 | 1 | 0 | 1 |
Logano GB212 | boiler | 170 | heatingoff | force heating off | boolean | | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | 5 | 0 | 1 | 1 | 1 |
Logano GB212 | boiler | 170 | heatingactive | heating active | boolean | | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | 5 | 0 | 1 | 2 | 1 |
Logano GB212 | boiler | 170 | tapwateractive | tapwater active | boolean | | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | 5 | 0 | 1 | 3 | 1 |
Logano GB212 | boiler | 170 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp | 5 | 0 | 1 | 4 | 1 |
Logano GB212 | boiler | 170 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod | 5 | 0 | 1 | 5 | 1 |
Logano GB212 | boiler | 170 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp | 5 | 0 | 1/10 | 6 | 1 |
Logano GB212 | boiler | 170 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp | 5 | 0 | 1/10 | 7 | 1 |
Logano GB212 | boiler | 170 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp | 5 | 0 | 1/10 | 8 | 1 |
Logano GB212 | boiler | 170 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp | 5 | 0 | 1/10 | 9 | 1 |
Logano GB212 | boiler | 170 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress | 5 | 0 | 1/10 | 10 | 1 |
Logano GB212 | boiler | 170 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp | 5 | 0 | 1/10 | 11 | 1 |
Logano GB212 | boiler | 170 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp | 5 | 0 | 1/10 | 12 | 1 |
Logano GB212 | boiler | 170 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp | 5 | 0 | 1/10 | 242 | 1 |
Logano GB212 | boiler | 170 | burngas | gas | boolean | | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | 5 | 0 | 1 | 243 | 1 |
Logano GB212 | boiler | 170 | burngas2 | gas stage 2 | boolean | | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | 5 | 0 | 1 | 244 | 1 |
Logano GB212 | boiler | 170 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr | 5 | 0 | 1/10 | 245 | 1 |
Logano GB212 | boiler | 170 | fanwork | fan | boolean | | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | 5 | 0 | 1 | 246 | 1 |
Logano GB212 | boiler | 170 | ignwork | ignition | boolean | | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | 5 | 0 | 1 | 247 | 1 |
Logano GB212 | boiler | 170 | oilpreheat | oil preheating | boolean | | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | 5 | 0 | 1 | 248 | 1 |
Logano GB212 | boiler | 170 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower | 5 | 0 | 1 | 249 | 1 |
Logano GB212 | boiler | 170 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower | 5 | 0 | 1 | 250 | 1 |
Logano GB212 | boiler | 170 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod | 5 | 0 | 1 | 251 | 1 |
Logano GB212 | boiler | 170 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow | 5 | 0 | 1 | 252 | 1 |
Logano GB212 | boiler | 170 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock | 5 | 0 | 1/10 | 253 | 1 |
Logano GB212 | boiler | 170 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston | 5 | 0 | 1 | 254 | 1 |
Logano GB212 | boiler | 170 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff | 5 | 0 | 1 | 255 | 1 |
Logano GB212 | boiler | 170 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston | 5 | 0 | 1 | 256 | 1 |
Logano GB212 | boiler | 170 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff | 5 | 0 | 1 | 257 | 1 |
Logano GB212 | boiler | 170 | curveon | heatingcurve on | boolean | | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | 5 | 0 | 1 | 258 | 1 |
Logano GB212 | boiler | 170 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase | 5 | 0 | 1 | 259 | 1 |
Logano GB212 | boiler | 170 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend | 5 | 0 | 1 | 260 | 1 |
Logano GB212 | boiler | 170 | summertemp | summer temperature | uint8 (>=0<=45) | C | True | number.boiler_summer_temperature | number.boiler_summertemp | 5 | 0 | 1 | 261 | 1 |
Logano GB212 | boiler | 170 | nofrostmode | nofrost mode | boolean | | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | 5 | 0 | 1 | 262 | 1 |
Logano GB212 | boiler | 170 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp | 5 | 0 | 1 | 263 | 1 |
Logano GB212 | boiler | 170 | heatingactivated | heating activated | boolean | | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | 5 | 0 | 1 | 13 | 1 |
Logano GB212 | boiler | 170 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp | 5 | 0 | 1 | 14 | 1 |
Logano GB212 | boiler | 170 | heatingpump | heating pump | boolean | | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | 5 | 0 | 1 | 15 | 1 |
Logano GB212 | boiler | 170 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax | 5 | 0 | 1 | 16 | 1 |
Logano GB212 | boiler | 170 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin | 5 | 0 | 1 | 17 | 1 |
Logano GB212 | boiler | 170 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | 5 | 0 | 1 | 18 | 1 |
Logano GB212 | boiler | 170 | pumpcharacter | boiler pump characteristic | enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] | | True | select.boiler_boiler_pump_characteristic | select.boiler_pumpcharacter | 5 | 0 | 1 | 19 | 1 |
Logano GB212 | boiler | 170 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay | 5 | 0 | 1 | 20 | 1 |
Logano GB212 | boiler | 170 | pumpontemp | pump logic temperature | uint8 (>=0<=60) | C | True | number.boiler_pump_logic_temperature | number.boiler_pumpontemp | 5 | 0 | 1 | 21 | 1 |
Logano GB212 | boiler | 170 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow | 5 | 0 | 1 | 22 | 1 |
Logano GB212 | boiler | 170 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow | 5 | 0 | 1 | 23 | 1 |
Logano GB212 | boiler | 170 | burnstarts | burner starts | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | 5 | 0 | 1 | 24 | 2 |
Logano GB212 | boiler | 170 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin | 5 | 0 | 1 | 26 | 2 |
Logano GB212 | boiler | 170 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin | 5 | 0 | 1 | 28 | 2 |
Logano GB212 | boiler | 170 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin | 5 | 0 | 1 | 30 | 2 |
Logano GB212 | boiler | 170 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | 5 | 0 | 1 | 32 | 2 |
Logano GB212 | boiler | 170 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime | 5 | 0 | 1 | 34 | 2 |
Logano GB212 | boiler | 170 | lastcode | last error code | string | | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | 5 | 0 | 1 | 36 | 28 |
Logano GB212 | boiler | 170 | servicecode | service code | string | | False | sensor.boiler_service_code | sensor.boiler_servicecode | 5 | 0 | 1 | 64 | 2 |
Logano GB212 | boiler | 170 | servicecodenumber | service code number | uint16 (>=0<=31999) | | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | 5 | 0 | 1 | 66 | 1 |
Logano GB212 | boiler | 170 | maintenancemessage | maintenance message | string | | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | 5 | 0 | 1 | 67 | 2 |
Logano GB212 | boiler | 170 | maintenance | maintenance scheduled | enum [off|time|date|manual] | | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | 5 | 0 | 1 | 69 | 1 |
Logano GB212 | boiler | 170 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime | 5 | 0 | 1 | 70 | 1 |
Logano GB212 | boiler | 170 | maintenancedate | next maintenance date | string | | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | 5 | 0 | 1 | 71 | 6 |
Logano GB212 | boiler | 170 | emergencyops | emergency operation | boolean | | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | 5 | 0 | 1 | 77 | 1 |
Logano GB212 | boiler | 170 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp | 5 | 0 | 1 | 78 | 1 |
Logano GB212 | boiler | 170 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat | 5 | 0 | 1/10 | 91 | 2 |
Logano GB212 | boiler | 170 | meter | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meter | 5 | 9 | 1/10 | 2 | 2 |
Logano GB212 | boiler | 170 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat | 5 | 0 | 1/10 | 264 | 2 |
Logano GB212 | boiler | 170 | gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeter | 5 | 9 | 1/10 | 69 | 2 |
Logano GB212 | boiler | 170 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 | 5 | 0 | 1/10 | 266 | 2 |
Logano GB212 | boiler | 170 | nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrg2 | 5 | 9 | 1/10 | 71 | 2 |
Logano GB212 | boiler | 170 | tapactivated | turn on/off | boolean | | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | 5 | 9 | 1 | 28 | 1 |
Logano GB212 | boiler | 170 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp | 5 | 9 | 1 | 29 | 1 |
Logano GB212 | boiler | 170 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp | 5 | 9 | 1 | 30 | 1 |
Logano GB212 | boiler | 170 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow | 5 | 9 | 1 | 31 | 1 |
Logano GB212 | boiler | 170 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus | 5 | 9 | 1 | 32 | 1 |
Logano GB212 | boiler | 170 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff | 5 | 9 | 1 | 33 | 1 |
Logano GB212 | boiler | 170 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle | 5 | 9 | 1 | 34 | 1 |
Logano GB212 | boiler | 170 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp | 5 | 9 | 1/10 | 35 | 1 |
Logano GB212 | boiler | 170 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | 5 | 9 | 1 | 36 | 1 |
Logano GB212 | boiler | 170 | comfort | comfort | enum [hot|eco|intelligent] | | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | 5 | 9 | 1 | 37 | 1 |
Logano GB212 | boiler | 170 | comfort1 | comfort mode | enum [high comfort|eco] | | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | 5 | 9 | 1 | 38 | 1 |
Logano GB212 | boiler | 170 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset | 5 | 9 | 1 | 39 | 1 |
Logano GB212 | boiler | 170 | chargeoptimization | charge optimization | boolean | | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | 5 | 9 | 1 | 40 | 1 |
Logano GB212 | boiler | 170 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower | 5 | 9 | 1 | 41 | 1 |
Logano GB212 | boiler | 170 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp | 5 | 9 | 1 | 42 | 1 |
Logano GB212 | boiler | 170 | circpump | circulation pump available | boolean | | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | 5 | 9 | 1 | 43 | 1 |
Logano GB212 | boiler | 170 | chargetype | charging type | enum [chargepump|3-way valve] | | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | 5 | 9 | 1 | 44 | 1 |
Logano GB212 | boiler | 170 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston | 5 | 9 | 1 | 45 | 1 |
Logano GB212 | boiler | 170 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff | 5 | 9 | 1 | 46 | 1 |
Logano GB212 | boiler | 170 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp | 5 | 9 | 1 | 47 | 1 |
Logano GB212 | boiler | 170 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | 5 | 9 | 1 | 48 | 1 |
Logano GB212 | boiler | 170 | circ | circulation active | boolean | | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | 5 | 9 | 1 | 49 | 1 |
Logano GB212 | boiler | 170 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp | 5 | 9 | 1/10 | 50 | 1 |
Logano GB212 | boiler | 170 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 | 5 | 9 | 1/10 | 51 | 1 |
Logano GB212 | boiler | 170 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow | 5 | 9 | 1/10 | 52 | 1 |
Logano GB212 | boiler | 170 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 | 5 | 9 | 1/10 | 53 | 1 |
Logano GB212 | boiler | 170 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 | 5 | 9 | 1/10 | 54 | 1 |
Logano GB212 | boiler | 170 | activated | activated | boolean | | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | 5 | 9 | 1 | 55 | 1 |
Logano GB212 | boiler | 170 | onetime | one time charging | boolean | | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | 5 | 9 | 1 | 56 | 1 |
Logano GB212 | boiler | 170 | disinfecting | disinfecting | boolean | | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | 5 | 9 | 1 | 57 | 1 |
Logano GB212 | boiler | 170 | charging | charging | boolean | | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | 5 | 9 | 1 | 58 | 1 |
Logano GB212 | boiler | 170 | recharging | recharging | boolean | | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | 5 | 9 | 1 | 59 | 1 |
Logano GB212 | boiler | 170 | tempok | temperature ok | boolean | | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | 5 | 9 | 1 | 60 | 1 |
Logano GB212 | boiler | 170 | active | active | boolean | | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | 5 | 9 | 1 | 61 | 1 |
Logano GB212 | boiler | 170 | 3wayvalve | 3-way valve active | boolean | | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | 5 | 9 | 1 | 62 | 1 |
Logano GB212 | boiler | 170 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp | 5 | 9 | 1/10 | 63 | 1 |
Logano GB212 | boiler | 170 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp | 5 | 9 | 1/10 | 64 | 1 |
Logano GB212 | boiler | 170 | starts | starts | uint24 (>=0<=16777213) | | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | 5 | 9 | 1 | 65 | 2 |
Logano GB212 | boiler | 170 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm | 5 | 9 | 1 | 67 | 2 |
Logano GB212 | boiler | 170 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower | 5 | 0 | 1 | 268 | 1 |
Logano GB212 | boiler | 170 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal | 5 | 0 | 1/100 | 79 | 2 |
Logano GB212 | boiler | 170 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat | 5 | 0 | 1/100 | 81 | 2 |
Logano GB212 | boiler | 170 | nrg | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrg | 5 | 9 | 1/100 | 0 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | reset | reset | cmd [-|maintenance|error|history|message] | | True | sensor.boiler_reset | sensor.boiler_reset | 5 | 0 | 1 | 0 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | heatingoff | force heating off | boolean | | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | 5 | 0 | 1 | 1 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | heatingactive | heating active | boolean | | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | 5 | 0 | 1 | 2 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | tapwateractive | tapwater active | boolean | | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | 5 | 0 | 1 | 3 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp | 5 | 0 | 1 | 4 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod | 5 | 0 | 1 | 5 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp | 5 | 0 | 1/10 | 6 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp | 5 | 0 | 1/10 | 7 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp | 5 | 0 | 1/10 | 8 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp | 5 | 0 | 1/10 | 9 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress | 5 | 0 | 1/10 | 10 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp | 5 | 0 | 1/10 | 11 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp | 5 | 0 | 1/10 | 12 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | heatingactivated | heating activated | boolean | | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | 5 | 0 | 1 | 13 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp | 5 | 0 | 1 | 14 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | heatingpump | heating pump | boolean | | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | 5 | 0 | 1 | 15 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax | 5 | 0 | 1 | 16 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin | 5 | 0 | 1 | 17 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | 5 | 0 | 1 | 18 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | pumpcharacter | boiler pump characteristic | enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] | | True | select.boiler_boiler_pump_characteristic | select.boiler_pumpcharacter | 5 | 0 | 1 | 19 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay | 5 | 0 | 1 | 20 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | pumpontemp | pump logic temperature | uint8 (>=0<=60) | C | True | number.boiler_pump_logic_temperature | number.boiler_pumpontemp | 5 | 0 | 1 | 21 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow | 5 | 0 | 1 | 22 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow | 5 | 0 | 1 | 23 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | burnstarts | burner starts | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | 5 | 0 | 1 | 24 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin | 5 | 0 | 1 | 26 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin | 5 | 0 | 1 | 28 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin | 5 | 0 | 1 | 30 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | 5 | 0 | 1 | 32 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime | 5 | 0 | 1 | 34 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | lastcode | last error code | string | | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | 5 | 0 | 1 | 36 | 28 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | servicecode | service code | string | | False | sensor.boiler_service_code | sensor.boiler_servicecode | 5 | 0 | 1 | 64 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | servicecodenumber | service code number | uint16 (>=0<=31999) | | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | 5 | 0 | 1 | 66 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | maintenancemessage | maintenance message | string | | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | 5 | 0 | 1 | 67 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | maintenance | maintenance scheduled | enum [off|time|date|manual] | | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | 5 | 0 | 1 | 69 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime | 5 | 0 | 1 | 70 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | maintenancedate | next maintenance date | string | | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | 5 | 0 | 1 | 71 | 6 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | emergencyops | emergency operation | boolean | | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | 5 | 0 | 1 | 77 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp | 5 | 0 | 1 | 78 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal | 5 | 0 | 1/100 | 79 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | nrg | energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_dhw_energy | sensor.boiler_dhw_nrg | 5 | 9 | 1/100 | 0 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | nrgheat | energy heating | uint24 (>=0<=167772) | kWh | False | sensor.boiler_energy_heating | sensor.boiler_nrgheat | 5 | 0 | 1/100 | 81 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | nrgcool | energy cooling | uint24 (>=0<=167772) | kWh | False | sensor.boiler_energy_cooling | sensor.boiler_nrgcool | 5 | 0 | 1/100 | 83 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | metertotal | meter total | uint24 (>=0<=167772) | kWh | False | sensor.boiler_meter_total | sensor.boiler_metertotal | 5 | 0 | 1/100 | 85 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | metercomp | meter compressor | uint24 (>=0<=167772) | kWh | False | sensor.boiler_meter_compressor | sensor.boiler_metercomp | 5 | 0 | 1/100 | 87 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | metereheat | meter e-heater | uint24 (>=0<=167772) | kWh | False | sensor.boiler_meter_e-heater | sensor.boiler_metereheat | 5 | 0 | 1/100 | 89 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | meterheat | meter heating | uint24 (>=0<=167772) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat | 5 | 0 | 1/100 | 91 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | metercool | meter cooling | uint24 (>=0<=167772) | kWh | False | sensor.boiler_meter_cooling | sensor.boiler_metercool | 5 | 0 | 1/100 | 93 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | meter | meter | uint24 (>=0<=167772) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meter | 5 | 9 | 1/100 | 2 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | uptimetotal | heatpump total uptime | time (>=0<=279620) | minutes | False | sensor.boiler_heatpump_total_uptime | sensor.boiler_uptimetotal | 5 | 0 | 1/60 | 95 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | uptimecontrol | total operating time heat | time (>=0<=279620) | minutes | False | sensor.boiler_total_operating_time_heat | sensor.boiler_uptimecontrol | 5 | 0 | 1/60 | 97 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | uptimecompheating | operating time compressor heating | time (>=0<=279620) | minutes | False | sensor.boiler_operating_time_compressor_heating | sensor.boiler_uptimecompheating | 5 | 0 | 1/60 | 99 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | uptimecompcooling | operating time compressor cooling | time (>=0<=279620) | minutes | False | sensor.boiler_operating_time_compressor_cooling | sensor.boiler_uptimecompcooling | 5 | 0 | 1/60 | 101 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | uptimecomp | operating time compressor | time (>=0<=279620) | minutes | False | sensor.boiler_dhw_operating_time_compressor | sensor.boiler_dhw_uptimecomp | 5 | 9 | 1/60 | 4 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | uptimecomppool | operating time compressor pool | time (>=0<=279620) | minutes | False | sensor.boiler_operating_time_compressor_pool | sensor.boiler_uptimecomppool | 5 | 0 | 1/60 | 103 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | totalcompstarts | total compressor control starts | uint24 (>=0<=16777213) | | False | sensor.boiler_total_compressor_control_starts | sensor.boiler_totalcompstarts | 5 | 0 | 1 | 105 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | heatingstarts | heating control starts | uint24 (>=0<=16777213) | | False | sensor.boiler_heating_control_starts | sensor.boiler_heatingstarts | 5 | 0 | 1 | 107 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | coolingstarts | cooling control starts | uint24 (>=0<=16777213) | | False | sensor.boiler_cooling_control_starts | sensor.boiler_coolingstarts | 5 | 0 | 1 | 109 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | starts2 | control starts2 | uint24 (>=0<=16777213) | | False | sensor.boiler_dhw_control_starts2 | sensor.boiler_dhw_starts2 | 5 | 9 | 1 | 6 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | poolstarts | pool control starts | uint24 (>=0<=16777213) | | False | sensor.boiler_pool_control_starts | sensor.boiler_poolstarts | 5 | 0 | 1 | 111 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | nrgconstotal | total energy consumption | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_energy_consumption | sensor.boiler_nrgconstotal | 5 | 0 | 1 | 113 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | nrgconscomptotal | total energy consumption compressor | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_energy_consumption_compressor | sensor.boiler_nrgconscomptotal | 5 | 0 | 1 | 115 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | nrgconscompheating | energy consumption compressor heating | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_energy_consumption_compressor_heating | sensor.boiler_nrgconscompheating | 5 | 0 | 1 | 117 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | nrgconscomp | energy consumption compressor | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_dhw_energy_consumption_compressor | sensor.boiler_dhw_nrgconscomp | 5 | 9 | 1 | 8 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | nrgconscompcooling | energy consumption compressor cooling | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_energy_consumption_compressor_cooling | sensor.boiler_nrgconscompcooling | 5 | 0 | 1 | 119 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | nrgconscomppool | energy consumption compressor pool | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_energy_consumption_compressor_pool | sensor.boiler_nrgconscomppool | 5 | 0 | 1 | 121 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | auxelecheatnrgconstotal | total aux elec. heater energy consumption | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_aux_elec._heater_energy_consumption | sensor.boiler_auxelecheatnrgconstotal | 5 | 0 | 1 | 123 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | auxelecheatnrgconsheating | aux elec. heater energy consumption heating | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_aux_elec._heater_energy_consumption_heating | sensor.boiler_auxelecheatnrgconsheating | 5 | 0 | 1 | 125 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | auxelecheatnrgcons | aux elec. heater energy consumption | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_dhw_aux_elec._heater_energy_consumption | sensor.boiler_dhw_auxelecheatnrgcons | 5 | 9 | 1 | 10 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | auxelecheatnrgconspool | aux elec. heater energy consumption pool | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_aux_elec._heater_energy_consumption_pool | sensor.boiler_auxelecheatnrgconspool | 5 | 0 | 1 | 127 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | nrgsupptotal | total energy supplied | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_energy_supplied | sensor.boiler_nrgsupptotal | 5 | 0 | 1 | 129 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | nrgsuppheating | total energy supplied heating | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_energy_supplied_heating | sensor.boiler_nrgsuppheating | 5 | 0 | 1 | 131 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | nrgsupp | total energy warm supplied | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_dhw_total_energy_warm_supplied | sensor.boiler_dhw_nrgsupp | 5 | 9 | 1 | 12 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | nrgsuppcooling | total energy supplied cooling | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_energy_supplied_cooling | sensor.boiler_nrgsuppcooling | 5 | 0 | 1 | 133 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | nrgsupppool | total energy supplied pool | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_energy_supplied_pool | sensor.boiler_nrgsupppool | 5 | 0 | 1 | 135 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hppower | compressor power output | uint8 (>=0<=25) | kW | False | sensor.boiler_compressor_power_output | sensor.boiler_hppower | 5 | 0 | 1/10 | 137 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hpmaxpower | compressor max power | uint8 (>=0<=100) | % | True | number.boiler_compressor_max_power | number.boiler_hpmaxpower | 5 | 0 | 1 | 138 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | pvmaxcomp | pv compressor max power | uint8 (>=0<=25) | kW | True | number.boiler_pv_compressor_max_power | number.boiler_pvmaxcomp | 5 | 0 | 1/10 | 139 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hpsetdiffpress | set differental pressure | uint8 (>=150<=750) | mbar | True | number.boiler_set_differental_pressure | number.boiler_hpsetdiffpress | 5 | 0 | 50 | 140 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hpcompon | hp compressor | boolean | | False | binary_sensor.boiler_hp_compressor | binary_sensor.boiler_hpcompon | 5 | 0 | 1 | 141 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hpactivity | compressor activity | enum [none|heating|cooling|hot water|pool|unknown|defrost] | | False | sensor.boiler_compressor_activity | sensor.boiler_hpactivity | 5 | 0 | 1 | 142 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hpbrinepumpspd | brine pump speed | uint8 (>=0<=100) | % | False | sensor.boiler_brine_pump_speed | sensor.boiler_hpbrinepumpspd | 5 | 0 | 1 | 143 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hpswitchvalve | switch valve | boolean | | False | binary_sensor.boiler_switch_valve | binary_sensor.boiler_hpswitchvalve | 5 | 0 | 1 | 144 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hpcompspd | compressor speed | uint8 (>=0<=100) | % | False | sensor.boiler_compressor_speed | sensor.boiler_hpcompspd | 5 | 0 | 1 | 145 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hpcircspd | circulation pump speed | uint8 (>=0<=100) | % | False | sensor.boiler_circulation_pump_speed | sensor.boiler_hpcircspd | 5 | 0 | 1 | 146 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hpbrinein | brine in/evaporator | int16 (>=-3199<=3199) | C | False | sensor.boiler_brine_in/evaporator | sensor.boiler_hpbrinein | 5 | 0 | 1/10 | 147 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hpbrineout | brine out/condenser | int16 (>=-3199<=3199) | C | False | sensor.boiler_brine_out/condenser | sensor.boiler_hpbrineout | 5 | 0 | 1/10 | 148 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hptc0 | heat carrier return (TC0) | int16 (>=-3199<=3199) | C | False | sensor.boiler_heat_carrier_return_(TC0) | sensor.boiler_hptc0 | 5 | 0 | 1/10 | 149 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hptc1 | heat carrier forward (TC1) | int16 (>=-3199<=3199) | C | False | sensor.boiler_heat_carrier_forward_(TC1) | sensor.boiler_hptc1 | 5 | 0 | 1/10 | 150 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hptc3 | condenser temperature (TC3) | int16 (>=-3199<=3199) | C | False | sensor.boiler_condenser_temperature_(TC3) | sensor.boiler_hptc3 | 5 | 0 | 1/10 | 151 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hptr1 | compressor temperature (TR1) | int16 (>=-3199<=3199) | C | False | sensor.boiler_compressor_temperature_(TR1) | sensor.boiler_hptr1 | 5 | 0 | 1/10 | 152 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hptr3 | refrigerant temperature liquid side (condenser output) (TR3) | int16 (>=-3199<=3199) | C | False | sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3) | sensor.boiler_hptr3 | 5 | 0 | 1/10 | 153 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hptr4 | evaporator inlet temperature (TR4) | int16 (>=-3199<=3199) | C | False | sensor.boiler_evaporator_inlet_temperature_(TR4) | sensor.boiler_hptr4 | 5 | 0 | 1/10 | 154 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hptr5 | compressor inlet temperature (TR5) | int16 (>=-3199<=3199) | C | False | sensor.boiler_compressor_inlet_temperature_(TR5) | sensor.boiler_hptr5 | 5 | 0 | 1/10 | 155 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hptr6 | compressor outlet temperature (TR6) | int16 (>=-3199<=3199) | C | False | sensor.boiler_compressor_outlet_temperature_(TR6) | sensor.boiler_hptr6 | 5 | 0 | 1/10 | 156 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hptr7 | refrigerant temperature gas side (condenser input) (TR7) | int16 (>=-3199<=3199) | C | False | sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7) | sensor.boiler_hptr7 | 5 | 0 | 1/10 | 157 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hptl2 | air inlet temperature (TL2) | int16 (>=-3199<=3199) | C | False | sensor.boiler_air_inlet_temperature_(TL2) | sensor.boiler_hptl2 | 5 | 0 | 1/10 | 158 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hppl1 | low pressure side temperature (PL1) | int16 (>=-3199<=3199) | C | False | sensor.boiler_low_pressure_side_temperature_(PL1) | sensor.boiler_hppl1 | 5 | 0 | 1/10 | 159 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hpph1 | high pressure side temperature (PH1) | int16 (>=-3199<=3199) | C | False | sensor.boiler_high_pressure_side_temperature_(PH1) | sensor.boiler_hpph1 | 5 | 0 | 1/10 | 160 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hpta4 | drain pan temp (TA4) | int16 (>=-3199<=3199) | C | False | sensor.boiler_drain_pan_temp_(TA4) | sensor.boiler_hpta4 | 5 | 0 | 1/10 | 161 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hptw1 | reservoir temp (TW1) | int16 (>=-3199<=3199) | C | False | sensor.boiler_reservoir_temp_(TW1) | sensor.boiler_hptw1 | 5 | 0 | 1/10 | 162 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | poolsettemp | pool set temperature | uint8 (>=0<=127) | C | True | number.boiler_pool_set_temperature | number.boiler_poolsettemp | 5 | 0 | 1/2 | 163 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hp4way | 4-way valve (VR4) | enum [cooling & defrost|heating & dhw] | | False | sensor.boiler_4-way_valve_(VR4) | sensor.boiler_hp4way | 5 | 0 | 1 | 164 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hpin1 | input 1 state | boolean | | False | binary_sensor.boiler_input_1_state | binary_sensor.boiler_hpin1 | 5 | 0 | 1 | 165 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hpin1opt | input 1 options | string | | True | sensor.boiler_input_1_options | sensor.boiler_hpin1opt | 5 | 0 | 1 | 166 | 8 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hpin2 | input 2 state | boolean | | False | binary_sensor.boiler_input_2_state | binary_sensor.boiler_hpin2 | 5 | 0 | 1 | 174 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hpin2opt | input 2 options | string | | True | sensor.boiler_input_2_options | sensor.boiler_hpin2opt | 5 | 0 | 1 | 175 | 8 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hpin3 | input 3 state | boolean | | False | binary_sensor.boiler_input_3_state | binary_sensor.boiler_hpin3 | 5 | 0 | 1 | 183 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hpin3opt | input 3 options | string | | True | sensor.boiler_input_3_options | sensor.boiler_hpin3opt | 5 | 0 | 1 | 184 | 8 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hpin4 | input 4 state | boolean | | False | binary_sensor.boiler_input_4_state | binary_sensor.boiler_hpin4 | 5 | 0 | 1 | 192 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hpin4opt | input 4 options | string | | True | sensor.boiler_input_4_options | sensor.boiler_hpin4opt | 5 | 0 | 1 | 193 | 8 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | maxheatcomp | heat limit compressor | enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] | | True | select.boiler_heat_limit_compressor | select.boiler_maxheatcomp | 5 | 0 | 1 | 201 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | maxheatheat | heat limit heating | enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] | | True | select.boiler_heat_limit_heating | select.boiler_maxheatheat | 5 | 0 | 1 | 202 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | maxheat | heat limit | enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] | | True | select.boiler_dhw_heat_limit | select.boiler_dhw_maxheat | 5 | 9 | 1 | 14 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | mandefrost | manual defrost | boolean | | True | switch.boiler_manual_defrost | switch.boiler_mandefrost | 5 | 0 | 1 | 203 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | pvcooling | cooling only with PV | boolean | | True | switch.boiler_cooling_only_with_PV | switch.boiler_pvcooling | 5 | 0 | 1 | 204 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | auxheateronly | aux heater only | boolean | | True | switch.boiler_aux_heater_only | switch.boiler_auxheateronly | 5 | 0 | 1 | 205 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | auxheateroff | disable aux heater | boolean | | True | switch.boiler_disable_aux_heater | switch.boiler_auxheateroff | 5 | 0 | 1 | 206 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | auxheaterstatus | aux heater status | uint8 (>=0<=100) | % | False | sensor.boiler_aux_heater_status | sensor.boiler_auxheaterstatus | 5 | 0 | 1 | 207 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | auxheaterdelay | aux heater on delay | uint16 (>=10<=1000) | K*min | True | number.boiler_aux_heater_on_delay | number.boiler_auxheaterdelay | 5 | 0 | 10 | 208 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | auxmaxlimit | aux heater max limit | uint8 (>=0<=10) | K | True | number.boiler_aux_heater_max_limit | number.boiler_auxmaxlimit | 5 | 0 | 1/10 | 209 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | auxlimitstart | aux heater limit start | uint8 (>=0<=10) | K | True | number.boiler_aux_heater_limit_start | number.boiler_auxlimitstart | 5 | 0 | 1/10 | 210 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | auxheatrmode | aux heater mode | enum [eco|comfort] | | True | select.boiler_aux_heater_mode | select.boiler_auxheatrmode | 5 | 0 | 1 | 211 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hphystheat | on/off hyst heat | uint16 (>=50<=1500) | K*min | True | number.boiler_on/off_hyst_heat | number.boiler_hphystheat | 5 | 0 | 5 | 212 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hphystcool | on/off hyst cool | uint16 (>=50<=1500) | K*min | True | number.boiler_on/off_hyst_cool | number.boiler_hphystcool | 5 | 0 | 5 | 213 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hphystpool | on/off hyst pool | uint16 (>=50<=1500) | K*min | True | number.boiler_on/off_hyst_pool | number.boiler_hphystpool | 5 | 0 | 5 | 214 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | silentmode | silent mode | enum [off|auto|on] | | True | select.boiler_silent_mode | select.boiler_silentmode | 5 | 0 | 1 | 215 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | silentfrom | silent mode from | uint8 (>=0<=3810) | minutes | True | number.boiler_silent_mode_from | number.boiler_silentfrom | 5 | 0 | 15 | 216 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | silentto | silent mode to | uint8 (>=0<=3810) | minutes | True | number.boiler_silent_mode_to | number.boiler_silentto | 5 | 0 | 15 | 217 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | mintempsilent | min outside temp for silent mode | int8 (>=-126<=126) | C | True | number.boiler_min_outside_temp_for_silent_mode | number.boiler_mintempsilent | 5 | 0 | 1 | 218 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | tempparmode | outside temp parallel mode | int8 (>=-126<=126) | C | True | number.boiler_outside_temp_parallel_mode | number.boiler_tempparmode | 5 | 0 | 1 | 219 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | auxheatmix | aux heater mixing valve | int8 (>=-100<=100) | % | False | sensor.boiler_aux_heater_mixing_valve | sensor.boiler_auxheatmix | 5 | 0 | 1 | 220 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | tempdiffheat | temp diff TC3/TC0 heat | uint8 (>=2<=10) | K | True | number.boiler_temp_diff_TC3/TC0_heat | number.boiler_tempdiffheat | 5 | 0 | 1/10 | 221 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | tempdiffcool | temp diff TC3/TC0 cool | uint8 (>=2<=10) | K | True | number.boiler_temp_diff_TC3/TC0_cool | number.boiler_tempdiffcool | 5 | 0 | 1/10 | 222 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | vpcooling | valve/pump cooling | boolean | | True | switch.boiler_valve/pump_cooling | switch.boiler_vpcooling | 5 | 0 | 1 | 223 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | heatcable | heating cable | boolean | | True | switch.boiler_heating_cable | switch.boiler_heatcable | 5 | 0 | 1 | 224 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | vc0valve | VC0 valve | boolean | | True | switch.boiler_VC0_valve | switch.boiler_vc0valve | 5 | 0 | 1 | 225 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | primepump | primary heatpump | boolean | | True | switch.boiler_primary_heatpump | switch.boiler_primepump | 5 | 0 | 1 | 226 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | primepumpmod | primary heatpump modulation | uint8 (>=0<=100) | % | True | number.boiler_primary_heatpump_modulation | number.boiler_primepumpmod | 5 | 0 | 1 | 227 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hp3way | 3-way valve | boolean | | True | switch.boiler_3-way_valve | switch.boiler_hp3way | 5 | 0 | 1 | 228 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | elheatstep1 | el. heater step 1 | boolean | | True | switch.boiler_el._heater_step_1 | switch.boiler_elheatstep1 | 5 | 0 | 1 | 229 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | elheatstep2 | el. heater step 2 | boolean | | True | switch.boiler_el._heater_step_2 | switch.boiler_elheatstep2 | 5 | 0 | 1 | 230 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | elheatstep3 | el. heater step 3 | boolean | | True | switch.boiler_el._heater_step_3 | switch.boiler_elheatstep3 | 5 | 0 | 1 | 231 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hpea0 | condensate reservoir heating (EA0) | boolean | | False | binary_sensor.boiler_condensate_reservoir_heating_(EA0) | binary_sensor.boiler_hpea0 | 5 | 0 | 1 | 232 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hppumpmode | primary heatpump mode | enum [auto|continuous] | | True | select.boiler_primary_heatpump_mode | select.boiler_hppumpmode | 5 | 0 | 1 | 233 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | fan | fan | uint8 (>=20<=100) | % | True | number.boiler_fan | number.boiler_fan | 5 | 0 | 1 | 234 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | shutdown | shutdown | cmd [off|on] | | True | sensor.boiler_shutdown | sensor.boiler_shutdown | 5 | 0 | 1 | 235 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hpcurrpower | compressor current power | uint16 (>=0<=31999) | W | False | sensor.boiler_compressor_current_power | sensor.boiler_hpcurrpower | 5 | 0 | 1 | 236 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hppowerlimit | power limit | uint16 (>=0<=31999) | W | True | number.boiler_power_limit | number.boiler_hppowerlimit | 5 | 0 | 1 | 237 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | pc0flow | Flow PC0 | int16 (>=-31999<=31999) | l/h | False | sensor.boiler_Flow_PC0 | sensor.boiler_pc0flow | 5 | 0 | 1 | 238 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | pc1flow | Flow PC1 | int16 (>=-31999<=31999) | l/h | False | sensor.boiler_Flow_PC1 | sensor.boiler_pc1flow | 5 | 0 | 1 | 239 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | pc1on | PC1 | boolean | | False | binary_sensor.boiler_PC1 | binary_sensor.boiler_pc1on | 5 | 0 | 1 | 240 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | pc1rate | PC1 rate | uint8 (>=0<=100) | % | False | sensor.boiler_PC1_rate | sensor.boiler_pc1rate | 5 | 0 | 1 | 241 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | alternatingop | alternating operation | boolean | | True | switch.boiler_dhw_alternating_operation | switch.boiler_dhw_alternatingop | 5 | 9 | 1 | 15 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | altopprioheat | prioritise heating during dhw | uint8 (>=20<=120) | minutes | True | number.boiler_dhw_prioritise_heating_during_dhw | number.boiler_dhw_altopprioheat | 5 | 9 | 1 | 16 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | altopprio | prioritise dhw during heating | uint8 (>=30<=120) | minutes | True | number.boiler_dhw_prioritise_dhw_during_heating | number.boiler_dhw_altopprio | 5 | 9 | 1 | 17 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | comfoff | comfort switch off | uint8 (>=15<=65) | C | True | number.boiler_dhw_comfort_switch_off | number.boiler_dhw_comfoff | 5 | 9 | 1 | 18 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | ecooff | eco switch off | uint8 (>=15<=65) | C | True | number.boiler_dhw_eco_switch_off | number.boiler_dhw_ecooff | 5 | 9 | 1 | 19 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | ecoplusoff | eco+ switch off | uint8 (>=48<=63) | C | True | number.boiler_dhw_eco+_switch_off | number.boiler_dhw_ecoplusoff | 5 | 9 | 1 | 20 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | comfdiff | comfort diff | uint8 (>=6<=12) | K | True | number.boiler_dhw_comfort_diff | number.boiler_dhw_comfdiff | 5 | 9 | 1 | 21 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | ecodiff | eco diff | uint8 (>=6<=12) | K | True | number.boiler_dhw_eco_diff | number.boiler_dhw_ecodiff | 5 | 9 | 1 | 22 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | ecoplusdiff | eco+ diff | uint8 (>=6<=12) | K | True | number.boiler_dhw_eco+_diff | number.boiler_dhw_ecoplusdiff | 5 | 9 | 1 | 23 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | comfstop | comfort stop temp | uint8 (>=0<=254) | C | True | number.boiler_dhw_comfort_stop_temp | number.boiler_dhw_comfstop | 5 | 9 | 1 | 24 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | ecostop | eco stop temp | uint8 (>=0<=254) | C | True | number.boiler_dhw_eco_stop_temp | number.boiler_dhw_ecostop | 5 | 9 | 1 | 25 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | ecoplusstop | eco+ stop temp | uint8 (>=0<=254) | C | True | number.boiler_dhw_eco+_stop_temp | number.boiler_dhw_ecoplusstop | 5 | 9 | 1 | 26 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hpcircpump | circulation pump available during dhw | boolean | | True | switch.boiler_dhw_circulation_pump_available_during_dhw | switch.boiler_dhw_hpcircpump | 5 | 9 | 1 | 27 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | tapactivated | turn on/off | boolean | | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | 5 | 9 | 1 | 28 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp | 5 | 9 | 1 | 29 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp | 5 | 9 | 1 | 30 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow | 5 | 9 | 1 | 31 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus | 5 | 9 | 1 | 32 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff | 5 | 9 | 1 | 33 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle | 5 | 9 | 1 | 34 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp | 5 | 9 | 1/10 | 35 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | 5 | 9 | 1 | 36 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | comfort | comfort | enum [hot|eco|intelligent] | | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | 5 | 9 | 1 | 37 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | comfort1 | comfort mode | enum [high comfort|eco] | | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | 5 | 9 | 1 | 38 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset | 5 | 9 | 1 | 39 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | chargeoptimization | charge optimization | boolean | | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | 5 | 9 | 1 | 40 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower | 5 | 9 | 1 | 41 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp | 5 | 9 | 1 | 42 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | circpump | circulation pump available | boolean | | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | 5 | 9 | 1 | 43 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | chargetype | charging type | enum [chargepump|3-way valve] | | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | 5 | 9 | 1 | 44 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston | 5 | 9 | 1 | 45 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff | 5 | 9 | 1 | 46 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp | 5 | 9 | 1 | 47 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | 5 | 9 | 1 | 48 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | circ | circulation active | boolean | | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | 5 | 9 | 1 | 49 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp | 5 | 9 | 1/10 | 50 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 | 5 | 9 | 1/10 | 51 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow | 5 | 9 | 1/10 | 52 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 | 5 | 9 | 1/10 | 53 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 | 5 | 9 | 1/10 | 54 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | activated | activated | boolean | | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | 5 | 9 | 1 | 55 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | onetime | one time charging | boolean | | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | 5 | 9 | 1 | 56 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | disinfecting | disinfecting | boolean | | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | 5 | 9 | 1 | 57 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | charging | charging | boolean | | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | 5 | 9 | 1 | 58 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | recharging | recharging | boolean | | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | 5 | 9 | 1 | 59 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | tempok | temperature ok | boolean | | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | 5 | 9 | 1 | 60 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | active | active | boolean | | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | 5 | 9 | 1 | 61 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | 3wayvalve | 3-way valve active | boolean | | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | 5 | 9 | 1 | 62 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp | 5 | 9 | 1/10 | 63 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp | 5 | 9 | 1/10 | 64 | 1 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | starts | starts | uint24 (>=0<=16777213) | | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | 5 | 9 | 1 | 65 | 2 |
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i | boiler | 172 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm | 5 | 9 | 1 | 67 | 2 |
Geo 5xx | boiler | 173 | reset | reset | cmd [-|maintenance|error|history|message] | | True | sensor.boiler_reset | sensor.boiler_reset | 5 | 0 | 1 | 0 | 1 |
Geo 5xx | boiler | 173 | heatingoff | force heating off | boolean | | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | 5 | 0 | 1 | 1 | 1 |
Geo 5xx | boiler | 173 | heatingactive | heating active | boolean | | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | 5 | 0 | 1 | 2 | 1 |
Geo 5xx | boiler | 173 | tapwateractive | tapwater active | boolean | | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | 5 | 0 | 1 | 3 | 1 |
Geo 5xx | boiler | 173 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp | 5 | 0 | 1 | 4 | 1 |
Geo 5xx | boiler | 173 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod | 5 | 0 | 1 | 5 | 1 |
Geo 5xx | boiler | 173 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp | 5 | 0 | 1/10 | 6 | 1 |
Geo 5xx | boiler | 173 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp | 5 | 0 | 1/10 | 7 | 1 |
Geo 5xx | boiler | 173 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp | 5 | 0 | 1/10 | 8 | 1 |
Geo 5xx | boiler | 173 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp | 5 | 0 | 1/10 | 9 | 1 |
Geo 5xx | boiler | 173 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress | 5 | 0 | 1/10 | 10 | 1 |
Geo 5xx | boiler | 173 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp | 5 | 0 | 1/10 | 11 | 1 |
Geo 5xx | boiler | 173 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp | 5 | 0 | 1/10 | 12 | 1 |
Geo 5xx | boiler | 173 | heatingactivated | heating activated | boolean | | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | 5 | 0 | 1 | 13 | 1 |
Geo 5xx | boiler | 173 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp | 5 | 0 | 1 | 14 | 1 |
Geo 5xx | boiler | 173 | heatingpump | heating pump | boolean | | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | 5 | 0 | 1 | 15 | 1 |
Geo 5xx | boiler | 173 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax | 5 | 0 | 1 | 16 | 1 |
Geo 5xx | boiler | 173 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin | 5 | 0 | 1 | 17 | 1 |
Geo 5xx | boiler | 173 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | 5 | 0 | 1 | 18 | 1 |
Geo 5xx | boiler | 173 | pumpcharacter | boiler pump characteristic | enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] | | True | select.boiler_boiler_pump_characteristic | select.boiler_pumpcharacter | 5 | 0 | 1 | 19 | 1 |
Geo 5xx | boiler | 173 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay | 5 | 0 | 1 | 20 | 1 |
Geo 5xx | boiler | 173 | pumpontemp | pump logic temperature | uint8 (>=0<=60) | C | True | number.boiler_pump_logic_temperature | number.boiler_pumpontemp | 5 | 0 | 1 | 21 | 1 |
Geo 5xx | boiler | 173 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow | 5 | 0 | 1 | 22 | 1 |
Geo 5xx | boiler | 173 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow | 5 | 0 | 1 | 23 | 1 |
Geo 5xx | boiler | 173 | burnstarts | burner starts | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | 5 | 0 | 1 | 24 | 2 |
Geo 5xx | boiler | 173 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin | 5 | 0 | 1 | 26 | 2 |
Geo 5xx | boiler | 173 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin | 5 | 0 | 1 | 28 | 2 |
Geo 5xx | boiler | 173 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin | 5 | 0 | 1 | 30 | 2 |
Geo 5xx | boiler | 173 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | 5 | 0 | 1 | 32 | 2 |
Geo 5xx | boiler | 173 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime | 5 | 0 | 1 | 34 | 2 |
Geo 5xx | boiler | 173 | lastcode | last error code | string | | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | 5 | 0 | 1 | 36 | 28 |
Geo 5xx | boiler | 173 | servicecode | service code | string | | False | sensor.boiler_service_code | sensor.boiler_servicecode | 5 | 0 | 1 | 64 | 2 |
Geo 5xx | boiler | 173 | servicecodenumber | service code number | uint16 (>=0<=31999) | | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | 5 | 0 | 1 | 66 | 1 |
Geo 5xx | boiler | 173 | maintenancemessage | maintenance message | string | | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | 5 | 0 | 1 | 67 | 2 |
Geo 5xx | boiler | 173 | maintenance | maintenance scheduled | enum [off|time|date|manual] | | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | 5 | 0 | 1 | 69 | 1 |
Geo 5xx | boiler | 173 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime | 5 | 0 | 1 | 70 | 1 |
Geo 5xx | boiler | 173 | maintenancedate | next maintenance date | string | | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | 5 | 0 | 1 | 71 | 6 |
Geo 5xx | boiler | 173 | emergencyops | emergency operation | boolean | | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | 5 | 0 | 1 | 77 | 1 |
Geo 5xx | boiler | 173 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp | 5 | 0 | 1 | 78 | 1 |
Geo 5xx | boiler | 173 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal | 5 | 0 | 1/100 | 79 | 2 |
Geo 5xx | boiler | 173 | nrg | energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_dhw_energy | sensor.boiler_dhw_nrg | 5 | 9 | 1/100 | 0 | 2 |
Geo 5xx | boiler | 173 | nrgheat | energy heating | uint24 (>=0<=167772) | kWh | False | sensor.boiler_energy_heating | sensor.boiler_nrgheat | 5 | 0 | 1/100 | 81 | 2 |
Geo 5xx | boiler | 173 | nrgcool | energy cooling | uint24 (>=0<=167772) | kWh | False | sensor.boiler_energy_cooling | sensor.boiler_nrgcool | 5 | 0 | 1/100 | 83 | 2 |
Geo 5xx | boiler | 173 | metertotal | meter total | uint24 (>=0<=167772) | kWh | False | sensor.boiler_meter_total | sensor.boiler_metertotal | 5 | 0 | 1/100 | 85 | 2 |
Geo 5xx | boiler | 173 | metercomp | meter compressor | uint24 (>=0<=167772) | kWh | False | sensor.boiler_meter_compressor | sensor.boiler_metercomp | 5 | 0 | 1/100 | 87 | 2 |
Geo 5xx | boiler | 173 | metereheat | meter e-heater | uint24 (>=0<=167772) | kWh | False | sensor.boiler_meter_e-heater | sensor.boiler_metereheat | 5 | 0 | 1/100 | 89 | 2 |
Geo 5xx | boiler | 173 | meterheat | meter heating | uint24 (>=0<=167772) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat | 5 | 0 | 1/100 | 91 | 2 |
Geo 5xx | boiler | 173 | metercool | meter cooling | uint24 (>=0<=167772) | kWh | False | sensor.boiler_meter_cooling | sensor.boiler_metercool | 5 | 0 | 1/100 | 93 | 2 |
Geo 5xx | boiler | 173 | meter | meter | uint24 (>=0<=167772) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meter | 5 | 9 | 1/100 | 2 | 2 |
Geo 5xx | boiler | 173 | uptimetotal | heatpump total uptime | time (>=0<=279620) | minutes | False | sensor.boiler_heatpump_total_uptime | sensor.boiler_uptimetotal | 5 | 0 | 1/60 | 95 | 2 |
Geo 5xx | boiler | 173 | uptimecontrol | total operating time heat | time (>=0<=279620) | minutes | False | sensor.boiler_total_operating_time_heat | sensor.boiler_uptimecontrol | 5 | 0 | 1/60 | 97 | 2 |
Geo 5xx | boiler | 173 | uptimecompheating | operating time compressor heating | time (>=0<=279620) | minutes | False | sensor.boiler_operating_time_compressor_heating | sensor.boiler_uptimecompheating | 5 | 0 | 1/60 | 99 | 2 |
Geo 5xx | boiler | 173 | uptimecompcooling | operating time compressor cooling | time (>=0<=279620) | minutes | False | sensor.boiler_operating_time_compressor_cooling | sensor.boiler_uptimecompcooling | 5 | 0 | 1/60 | 101 | 2 |
Geo 5xx | boiler | 173 | uptimecomp | operating time compressor | time (>=0<=279620) | minutes | False | sensor.boiler_dhw_operating_time_compressor | sensor.boiler_dhw_uptimecomp | 5 | 9 | 1/60 | 4 | 2 |
Geo 5xx | boiler | 173 | uptimecomppool | operating time compressor pool | time (>=0<=279620) | minutes | False | sensor.boiler_operating_time_compressor_pool | sensor.boiler_uptimecomppool | 5 | 0 | 1/60 | 103 | 2 |
Geo 5xx | boiler | 173 | totalcompstarts | total compressor control starts | uint24 (>=0<=16777213) | | False | sensor.boiler_total_compressor_control_starts | sensor.boiler_totalcompstarts | 5 | 0 | 1 | 105 | 2 |
Geo 5xx | boiler | 173 | heatingstarts | heating control starts | uint24 (>=0<=16777213) | | False | sensor.boiler_heating_control_starts | sensor.boiler_heatingstarts | 5 | 0 | 1 | 107 | 2 |
Geo 5xx | boiler | 173 | coolingstarts | cooling control starts | uint24 (>=0<=16777213) | | False | sensor.boiler_cooling_control_starts | sensor.boiler_coolingstarts | 5 | 0 | 1 | 109 | 2 |
Geo 5xx | boiler | 173 | starts2 | control starts2 | uint24 (>=0<=16777213) | | False | sensor.boiler_dhw_control_starts2 | sensor.boiler_dhw_starts2 | 5 | 9 | 1 | 6 | 2 |
Geo 5xx | boiler | 173 | poolstarts | pool control starts | uint24 (>=0<=16777213) | | False | sensor.boiler_pool_control_starts | sensor.boiler_poolstarts | 5 | 0 | 1 | 111 | 2 |
Geo 5xx | boiler | 173 | nrgconstotal | total energy consumption | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_energy_consumption | sensor.boiler_nrgconstotal | 5 | 0 | 1 | 113 | 2 |
Geo 5xx | boiler | 173 | nrgconscomptotal | total energy consumption compressor | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_energy_consumption_compressor | sensor.boiler_nrgconscomptotal | 5 | 0 | 1 | 115 | 2 |
Geo 5xx | boiler | 173 | nrgconscompheating | energy consumption compressor heating | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_energy_consumption_compressor_heating | sensor.boiler_nrgconscompheating | 5 | 0 | 1 | 117 | 2 |
Geo 5xx | boiler | 173 | nrgconscomp | energy consumption compressor | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_dhw_energy_consumption_compressor | sensor.boiler_dhw_nrgconscomp | 5 | 9 | 1 | 8 | 2 |
Geo 5xx | boiler | 173 | nrgconscompcooling | energy consumption compressor cooling | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_energy_consumption_compressor_cooling | sensor.boiler_nrgconscompcooling | 5 | 0 | 1 | 119 | 2 |
Geo 5xx | boiler | 173 | nrgconscomppool | energy consumption compressor pool | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_energy_consumption_compressor_pool | sensor.boiler_nrgconscomppool | 5 | 0 | 1 | 121 | 2 |
Geo 5xx | boiler | 173 | auxelecheatnrgconstotal | total aux elec. heater energy consumption | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_aux_elec._heater_energy_consumption | sensor.boiler_auxelecheatnrgconstotal | 5 | 0 | 1 | 123 | 2 |
Geo 5xx | boiler | 173 | auxelecheatnrgconsheating | aux elec. heater energy consumption heating | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_aux_elec._heater_energy_consumption_heating | sensor.boiler_auxelecheatnrgconsheating | 5 | 0 | 1 | 125 | 2 |
Geo 5xx | boiler | 173 | auxelecheatnrgcons | aux elec. heater energy consumption | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_dhw_aux_elec._heater_energy_consumption | sensor.boiler_dhw_auxelecheatnrgcons | 5 | 9 | 1 | 10 | 2 |
Geo 5xx | boiler | 173 | auxelecheatnrgconspool | aux elec. heater energy consumption pool | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_aux_elec._heater_energy_consumption_pool | sensor.boiler_auxelecheatnrgconspool | 5 | 0 | 1 | 127 | 2 |
Geo 5xx | boiler | 173 | nrgsupptotal | total energy supplied | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_energy_supplied | sensor.boiler_nrgsupptotal | 5 | 0 | 1 | 129 | 2 |
Geo 5xx | boiler | 173 | nrgsuppheating | total energy supplied heating | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_energy_supplied_heating | sensor.boiler_nrgsuppheating | 5 | 0 | 1 | 131 | 2 |
Geo 5xx | boiler | 173 | nrgsupp | total energy warm supplied | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_dhw_total_energy_warm_supplied | sensor.boiler_dhw_nrgsupp | 5 | 9 | 1 | 12 | 2 |
Geo 5xx | boiler | 173 | nrgsuppcooling | total energy supplied cooling | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_energy_supplied_cooling | sensor.boiler_nrgsuppcooling | 5 | 0 | 1 | 133 | 2 |
Geo 5xx | boiler | 173 | nrgsupppool | total energy supplied pool | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_energy_supplied_pool | sensor.boiler_nrgsupppool | 5 | 0 | 1 | 135 | 2 |
Geo 5xx | boiler | 173 | hppower | compressor power output | uint8 (>=0<=25) | kW | False | sensor.boiler_compressor_power_output | sensor.boiler_hppower | 5 | 0 | 1/10 | 137 | 1 |
Geo 5xx | boiler | 173 | hpmaxpower | compressor max power | uint8 (>=0<=100) | % | True | number.boiler_compressor_max_power | number.boiler_hpmaxpower | 5 | 0 | 1 | 138 | 1 |
Geo 5xx | boiler | 173 | pvmaxcomp | pv compressor max power | uint8 (>=0<=25) | kW | True | number.boiler_pv_compressor_max_power | number.boiler_pvmaxcomp | 5 | 0 | 1/10 | 139 | 1 |
Geo 5xx | boiler | 173 | hpsetdiffpress | set differental pressure | uint8 (>=150<=750) | mbar | True | number.boiler_set_differental_pressure | number.boiler_hpsetdiffpress | 5 | 0 | 50 | 140 | 1 |
Geo 5xx | boiler | 173 | hpcompon | hp compressor | boolean | | False | binary_sensor.boiler_hp_compressor | binary_sensor.boiler_hpcompon | 5 | 0 | 1 | 141 | 1 |
Geo 5xx | boiler | 173 | hpactivity | compressor activity | enum [none|heating|cooling|hot water|pool|unknown|defrost] | | False | sensor.boiler_compressor_activity | sensor.boiler_hpactivity | 5 | 0 | 1 | 142 | 1 |
Geo 5xx | boiler | 173 | hpbrinepumpspd | brine pump speed | uint8 (>=0<=100) | % | False | sensor.boiler_brine_pump_speed | sensor.boiler_hpbrinepumpspd | 5 | 0 | 1 | 143 | 1 |
Geo 5xx | boiler | 173 | hpswitchvalve | switch valve | boolean | | False | binary_sensor.boiler_switch_valve | binary_sensor.boiler_hpswitchvalve | 5 | 0 | 1 | 144 | 1 |
Geo 5xx | boiler | 173 | hpcompspd | compressor speed | uint8 (>=0<=100) | % | False | sensor.boiler_compressor_speed | sensor.boiler_hpcompspd | 5 | 0 | 1 | 145 | 1 |
Geo 5xx | boiler | 173 | hpcircspd | circulation pump speed | uint8 (>=0<=100) | % | False | sensor.boiler_circulation_pump_speed | sensor.boiler_hpcircspd | 5 | 0 | 1 | 146 | 1 |
Geo 5xx | boiler | 173 | hpbrinein | brine in/evaporator | int16 (>=-3199<=3199) | C | False | sensor.boiler_brine_in/evaporator | sensor.boiler_hpbrinein | 5 | 0 | 1/10 | 147 | 1 |
Geo 5xx | boiler | 173 | hpbrineout | brine out/condenser | int16 (>=-3199<=3199) | C | False | sensor.boiler_brine_out/condenser | sensor.boiler_hpbrineout | 5 | 0 | 1/10 | 148 | 1 |
Geo 5xx | boiler | 173 | hptc0 | heat carrier return (TC0) | int16 (>=-3199<=3199) | C | False | sensor.boiler_heat_carrier_return_(TC0) | sensor.boiler_hptc0 | 5 | 0 | 1/10 | 149 | 1 |
Geo 5xx | boiler | 173 | hptc1 | heat carrier forward (TC1) | int16 (>=-3199<=3199) | C | False | sensor.boiler_heat_carrier_forward_(TC1) | sensor.boiler_hptc1 | 5 | 0 | 1/10 | 150 | 1 |
Geo 5xx | boiler | 173 | hptc3 | condenser temperature (TC3) | int16 (>=-3199<=3199) | C | False | sensor.boiler_condenser_temperature_(TC3) | sensor.boiler_hptc3 | 5 | 0 | 1/10 | 151 | 1 |
Geo 5xx | boiler | 173 | hptr1 | compressor temperature (TR1) | int16 (>=-3199<=3199) | C | False | sensor.boiler_compressor_temperature_(TR1) | sensor.boiler_hptr1 | 5 | 0 | 1/10 | 152 | 1 |
Geo 5xx | boiler | 173 | hptr3 | refrigerant temperature liquid side (condenser output) (TR3) | int16 (>=-3199<=3199) | C | False | sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3) | sensor.boiler_hptr3 | 5 | 0 | 1/10 | 153 | 1 |
Geo 5xx | boiler | 173 | hptr4 | evaporator inlet temperature (TR4) | int16 (>=-3199<=3199) | C | False | sensor.boiler_evaporator_inlet_temperature_(TR4) | sensor.boiler_hptr4 | 5 | 0 | 1/10 | 154 | 1 |
Geo 5xx | boiler | 173 | hptr5 | compressor inlet temperature (TR5) | int16 (>=-3199<=3199) | C | False | sensor.boiler_compressor_inlet_temperature_(TR5) | sensor.boiler_hptr5 | 5 | 0 | 1/10 | 155 | 1 |
Geo 5xx | boiler | 173 | hptr6 | compressor outlet temperature (TR6) | int16 (>=-3199<=3199) | C | False | sensor.boiler_compressor_outlet_temperature_(TR6) | sensor.boiler_hptr6 | 5 | 0 | 1/10 | 156 | 1 |
Geo 5xx | boiler | 173 | hptr7 | refrigerant temperature gas side (condenser input) (TR7) | int16 (>=-3199<=3199) | C | False | sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7) | sensor.boiler_hptr7 | 5 | 0 | 1/10 | 157 | 1 |
Geo 5xx | boiler | 173 | hptl2 | air inlet temperature (TL2) | int16 (>=-3199<=3199) | C | False | sensor.boiler_air_inlet_temperature_(TL2) | sensor.boiler_hptl2 | 5 | 0 | 1/10 | 158 | 1 |
Geo 5xx | boiler | 173 | hppl1 | low pressure side temperature (PL1) | int16 (>=-3199<=3199) | C | False | sensor.boiler_low_pressure_side_temperature_(PL1) | sensor.boiler_hppl1 | 5 | 0 | 1/10 | 159 | 1 |
Geo 5xx | boiler | 173 | hpph1 | high pressure side temperature (PH1) | int16 (>=-3199<=3199) | C | False | sensor.boiler_high_pressure_side_temperature_(PH1) | sensor.boiler_hpph1 | 5 | 0 | 1/10 | 160 | 1 |
Geo 5xx | boiler | 173 | hpta4 | drain pan temp (TA4) | int16 (>=-3199<=3199) | C | False | sensor.boiler_drain_pan_temp_(TA4) | sensor.boiler_hpta4 | 5 | 0 | 1/10 | 161 | 1 |
Geo 5xx | boiler | 173 | hptw1 | reservoir temp (TW1) | int16 (>=-3199<=3199) | C | False | sensor.boiler_reservoir_temp_(TW1) | sensor.boiler_hptw1 | 5 | 0 | 1/10 | 162 | 1 |
Geo 5xx | boiler | 173 | poolsettemp | pool set temperature | uint8 (>=0<=127) | C | True | number.boiler_pool_set_temperature | number.boiler_poolsettemp | 5 | 0 | 1/2 | 163 | 1 |
Geo 5xx | boiler | 173 | hp4way | 4-way valve (VR4) | enum [cooling & defrost|heating & dhw] | | False | sensor.boiler_4-way_valve_(VR4) | sensor.boiler_hp4way | 5 | 0 | 1 | 164 | 1 |
Geo 5xx | boiler | 173 | hpin1 | input 1 state | boolean | | False | binary_sensor.boiler_input_1_state | binary_sensor.boiler_hpin1 | 5 | 0 | 1 | 165 | 1 |
Geo 5xx | boiler | 173 | hpin1opt | input 1 options | string | | True | sensor.boiler_input_1_options | sensor.boiler_hpin1opt | 5 | 0 | 1 | 166 | 8 |
Geo 5xx | boiler | 173 | hpin2 | input 2 state | boolean | | False | binary_sensor.boiler_input_2_state | binary_sensor.boiler_hpin2 | 5 | 0 | 1 | 174 | 1 |
Geo 5xx | boiler | 173 | hpin2opt | input 2 options | string | | True | sensor.boiler_input_2_options | sensor.boiler_hpin2opt | 5 | 0 | 1 | 175 | 8 |
Geo 5xx | boiler | 173 | hpin3 | input 3 state | boolean | | False | binary_sensor.boiler_input_3_state | binary_sensor.boiler_hpin3 | 5 | 0 | 1 | 183 | 1 |
Geo 5xx | boiler | 173 | hpin3opt | input 3 options | string | | True | sensor.boiler_input_3_options | sensor.boiler_hpin3opt | 5 | 0 | 1 | 184 | 8 |
Geo 5xx | boiler | 173 | hpin4 | input 4 state | boolean | | False | binary_sensor.boiler_input_4_state | binary_sensor.boiler_hpin4 | 5 | 0 | 1 | 192 | 1 |
Geo 5xx | boiler | 173 | hpin4opt | input 4 options | string | | True | sensor.boiler_input_4_options | sensor.boiler_hpin4opt | 5 | 0 | 1 | 193 | 8 |
Geo 5xx | boiler | 173 | maxheatcomp | heat limit compressor | enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] | | True | select.boiler_heat_limit_compressor | select.boiler_maxheatcomp | 5 | 0 | 1 | 201 | 1 |
Geo 5xx | boiler | 173 | maxheatheat | heat limit heating | enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] | | True | select.boiler_heat_limit_heating | select.boiler_maxheatheat | 5 | 0 | 1 | 202 | 1 |
Geo 5xx | boiler | 173 | maxheat | heat limit | enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] | | True | select.boiler_dhw_heat_limit | select.boiler_dhw_maxheat | 5 | 9 | 1 | 14 | 1 |
Geo 5xx | boiler | 173 | mandefrost | manual defrost | boolean | | True | switch.boiler_manual_defrost | switch.boiler_mandefrost | 5 | 0 | 1 | 203 | 1 |
Geo 5xx | boiler | 173 | pvcooling | cooling only with PV | boolean | | True | switch.boiler_cooling_only_with_PV | switch.boiler_pvcooling | 5 | 0 | 1 | 204 | 1 |
Geo 5xx | boiler | 173 | auxheateronly | aux heater only | boolean | | True | switch.boiler_aux_heater_only | switch.boiler_auxheateronly | 5 | 0 | 1 | 205 | 1 |
Geo 5xx | boiler | 173 | auxheateroff | disable aux heater | boolean | | True | switch.boiler_disable_aux_heater | switch.boiler_auxheateroff | 5 | 0 | 1 | 206 | 1 |
Geo 5xx | boiler | 173 | auxheaterstatus | aux heater status | uint8 (>=0<=100) | % | False | sensor.boiler_aux_heater_status | sensor.boiler_auxheaterstatus | 5 | 0 | 1 | 207 | 1 |
Geo 5xx | boiler | 173 | auxheaterdelay | aux heater on delay | uint16 (>=10<=1000) | K*min | True | number.boiler_aux_heater_on_delay | number.boiler_auxheaterdelay | 5 | 0 | 10 | 208 | 1 |
Geo 5xx | boiler | 173 | auxmaxlimit | aux heater max limit | uint8 (>=0<=10) | K | True | number.boiler_aux_heater_max_limit | number.boiler_auxmaxlimit | 5 | 0 | 1/10 | 209 | 1 |
Geo 5xx | boiler | 173 | auxlimitstart | aux heater limit start | uint8 (>=0<=10) | K | True | number.boiler_aux_heater_limit_start | number.boiler_auxlimitstart | 5 | 0 | 1/10 | 210 | 1 |
Geo 5xx | boiler | 173 | auxheatrmode | aux heater mode | enum [eco|comfort] | | True | select.boiler_aux_heater_mode | select.boiler_auxheatrmode | 5 | 0 | 1 | 211 | 1 |
Geo 5xx | boiler | 173 | hphystheat | on/off hyst heat | uint16 (>=50<=1500) | K*min | True | number.boiler_on/off_hyst_heat | number.boiler_hphystheat | 5 | 0 | 5 | 212 | 1 |
Geo 5xx | boiler | 173 | hphystcool | on/off hyst cool | uint16 (>=50<=1500) | K*min | True | number.boiler_on/off_hyst_cool | number.boiler_hphystcool | 5 | 0 | 5 | 213 | 1 |
Geo 5xx | boiler | 173 | hphystpool | on/off hyst pool | uint16 (>=50<=1500) | K*min | True | number.boiler_on/off_hyst_pool | number.boiler_hphystpool | 5 | 0 | 5 | 214 | 1 |
Geo 5xx | boiler | 173 | silentmode | silent mode | enum [off|auto|on] | | True | select.boiler_silent_mode | select.boiler_silentmode | 5 | 0 | 1 | 215 | 1 |
Geo 5xx | boiler | 173 | silentfrom | silent mode from | uint8 (>=0<=3810) | minutes | True | number.boiler_silent_mode_from | number.boiler_silentfrom | 5 | 0 | 15 | 216 | 1 |
Geo 5xx | boiler | 173 | silentto | silent mode to | uint8 (>=0<=3810) | minutes | True | number.boiler_silent_mode_to | number.boiler_silentto | 5 | 0 | 15 | 217 | 1 |
Geo 5xx | boiler | 173 | mintempsilent | min outside temp for silent mode | int8 (>=-126<=126) | C | True | number.boiler_min_outside_temp_for_silent_mode | number.boiler_mintempsilent | 5 | 0 | 1 | 218 | 1 |
Geo 5xx | boiler | 173 | tempparmode | outside temp parallel mode | int8 (>=-126<=126) | C | True | number.boiler_outside_temp_parallel_mode | number.boiler_tempparmode | 5 | 0 | 1 | 219 | 1 |
Geo 5xx | boiler | 173 | auxheatmix | aux heater mixing valve | int8 (>=-100<=100) | % | False | sensor.boiler_aux_heater_mixing_valve | sensor.boiler_auxheatmix | 5 | 0 | 1 | 220 | 1 |
Geo 5xx | boiler | 173 | tempdiffheat | temp diff TC3/TC0 heat | uint8 (>=2<=10) | K | True | number.boiler_temp_diff_TC3/TC0_heat | number.boiler_tempdiffheat | 5 | 0 | 1/10 | 221 | 1 |
Geo 5xx | boiler | 173 | tempdiffcool | temp diff TC3/TC0 cool | uint8 (>=2<=10) | K | True | number.boiler_temp_diff_TC3/TC0_cool | number.boiler_tempdiffcool | 5 | 0 | 1/10 | 222 | 1 |
Geo 5xx | boiler | 173 | vpcooling | valve/pump cooling | boolean | | True | switch.boiler_valve/pump_cooling | switch.boiler_vpcooling | 5 | 0 | 1 | 223 | 1 |
Geo 5xx | boiler | 173 | heatcable | heating cable | boolean | | True | switch.boiler_heating_cable | switch.boiler_heatcable | 5 | 0 | 1 | 224 | 1 |
Geo 5xx | boiler | 173 | vc0valve | VC0 valve | boolean | | True | switch.boiler_VC0_valve | switch.boiler_vc0valve | 5 | 0 | 1 | 225 | 1 |
Geo 5xx | boiler | 173 | primepump | primary heatpump | boolean | | True | switch.boiler_primary_heatpump | switch.boiler_primepump | 5 | 0 | 1 | 226 | 1 |
Geo 5xx | boiler | 173 | primepumpmod | primary heatpump modulation | uint8 (>=0<=100) | % | True | number.boiler_primary_heatpump_modulation | number.boiler_primepumpmod | 5 | 0 | 1 | 227 | 1 |
Geo 5xx | boiler | 173 | hp3way | 3-way valve | boolean | | True | switch.boiler_3-way_valve | switch.boiler_hp3way | 5 | 0 | 1 | 228 | 1 |
Geo 5xx | boiler | 173 | elheatstep1 | el. heater step 1 | boolean | | True | switch.boiler_el._heater_step_1 | switch.boiler_elheatstep1 | 5 | 0 | 1 | 229 | 1 |
Geo 5xx | boiler | 173 | elheatstep2 | el. heater step 2 | boolean | | True | switch.boiler_el._heater_step_2 | switch.boiler_elheatstep2 | 5 | 0 | 1 | 230 | 1 |
Geo 5xx | boiler | 173 | elheatstep3 | el. heater step 3 | boolean | | True | switch.boiler_el._heater_step_3 | switch.boiler_elheatstep3 | 5 | 0 | 1 | 231 | 1 |
Geo 5xx | boiler | 173 | hpea0 | condensate reservoir heating (EA0) | boolean | | False | binary_sensor.boiler_condensate_reservoir_heating_(EA0) | binary_sensor.boiler_hpea0 | 5 | 0 | 1 | 232 | 1 |
Geo 5xx | boiler | 173 | hppumpmode | primary heatpump mode | enum [auto|continuous] | | True | select.boiler_primary_heatpump_mode | select.boiler_hppumpmode | 5 | 0 | 1 | 233 | 1 |
Geo 5xx | boiler | 173 | fan | fan | uint8 (>=20<=100) | % | True | number.boiler_fan | number.boiler_fan | 5 | 0 | 1 | 234 | 1 |
Geo 5xx | boiler | 173 | shutdown | shutdown | cmd [off|on] | | True | sensor.boiler_shutdown | sensor.boiler_shutdown | 5 | 0 | 1 | 235 | 1 |
Geo 5xx | boiler | 173 | hpcurrpower | compressor current power | uint16 (>=0<=31999) | W | False | sensor.boiler_compressor_current_power | sensor.boiler_hpcurrpower | 5 | 0 | 1 | 236 | 1 |
Geo 5xx | boiler | 173 | hppowerlimit | power limit | uint16 (>=0<=31999) | W | True | number.boiler_power_limit | number.boiler_hppowerlimit | 5 | 0 | 1 | 237 | 1 |
Geo 5xx | boiler | 173 | pc0flow | Flow PC0 | int16 (>=-31999<=31999) | l/h | False | sensor.boiler_Flow_PC0 | sensor.boiler_pc0flow | 5 | 0 | 1 | 238 | 1 |
Geo 5xx | boiler | 173 | pc1flow | Flow PC1 | int16 (>=-31999<=31999) | l/h | False | sensor.boiler_Flow_PC1 | sensor.boiler_pc1flow | 5 | 0 | 1 | 239 | 1 |
Geo 5xx | boiler | 173 | pc1on | PC1 | boolean | | False | binary_sensor.boiler_PC1 | binary_sensor.boiler_pc1on | 5 | 0 | 1 | 240 | 1 |
Geo 5xx | boiler | 173 | pc1rate | PC1 rate | uint8 (>=0<=100) | % | False | sensor.boiler_PC1_rate | sensor.boiler_pc1rate | 5 | 0 | 1 | 241 | 1 |
Geo 5xx | boiler | 173 | alternatingop | alternating operation | boolean | | True | switch.boiler_dhw_alternating_operation | switch.boiler_dhw_alternatingop | 5 | 9 | 1 | 15 | 1 |
Geo 5xx | boiler | 173 | altopprioheat | prioritise heating during dhw | uint8 (>=20<=120) | minutes | True | number.boiler_dhw_prioritise_heating_during_dhw | number.boiler_dhw_altopprioheat | 5 | 9 | 1 | 16 | 1 |
Geo 5xx | boiler | 173 | altopprio | prioritise dhw during heating | uint8 (>=30<=120) | minutes | True | number.boiler_dhw_prioritise_dhw_during_heating | number.boiler_dhw_altopprio | 5 | 9 | 1 | 17 | 1 |
Geo 5xx | boiler | 173 | comfoff | comfort switch off | uint8 (>=15<=65) | C | True | number.boiler_dhw_comfort_switch_off | number.boiler_dhw_comfoff | 5 | 9 | 1 | 18 | 1 |
Geo 5xx | boiler | 173 | ecooff | eco switch off | uint8 (>=15<=65) | C | True | number.boiler_dhw_eco_switch_off | number.boiler_dhw_ecooff | 5 | 9 | 1 | 19 | 1 |
Geo 5xx | boiler | 173 | ecoplusoff | eco+ switch off | uint8 (>=48<=63) | C | True | number.boiler_dhw_eco+_switch_off | number.boiler_dhw_ecoplusoff | 5 | 9 | 1 | 20 | 1 |
Geo 5xx | boiler | 173 | comfdiff | comfort diff | uint8 (>=6<=12) | K | True | number.boiler_dhw_comfort_diff | number.boiler_dhw_comfdiff | 5 | 9 | 1 | 21 | 1 |
Geo 5xx | boiler | 173 | ecodiff | eco diff | uint8 (>=6<=12) | K | True | number.boiler_dhw_eco_diff | number.boiler_dhw_ecodiff | 5 | 9 | 1 | 22 | 1 |
Geo 5xx | boiler | 173 | ecoplusdiff | eco+ diff | uint8 (>=6<=12) | K | True | number.boiler_dhw_eco+_diff | number.boiler_dhw_ecoplusdiff | 5 | 9 | 1 | 23 | 1 |
Geo 5xx | boiler | 173 | comfstop | comfort stop temp | uint8 (>=0<=254) | C | True | number.boiler_dhw_comfort_stop_temp | number.boiler_dhw_comfstop | 5 | 9 | 1 | 24 | 1 |
Geo 5xx | boiler | 173 | ecostop | eco stop temp | uint8 (>=0<=254) | C | True | number.boiler_dhw_eco_stop_temp | number.boiler_dhw_ecostop | 5 | 9 | 1 | 25 | 1 |
Geo 5xx | boiler | 173 | ecoplusstop | eco+ stop temp | uint8 (>=0<=254) | C | True | number.boiler_dhw_eco+_stop_temp | number.boiler_dhw_ecoplusstop | 5 | 9 | 1 | 26 | 1 |
Geo 5xx | boiler | 173 | hpcircpump | circulation pump available during dhw | boolean | | True | switch.boiler_dhw_circulation_pump_available_during_dhw | switch.boiler_dhw_hpcircpump | 5 | 9 | 1 | 27 | 1 |
Geo 5xx | boiler | 173 | tapactivated | turn on/off | boolean | | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | 5 | 9 | 1 | 28 | 1 |
Geo 5xx | boiler | 173 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp | 5 | 9 | 1 | 29 | 1 |
Geo 5xx | boiler | 173 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp | 5 | 9 | 1 | 30 | 1 |
Geo 5xx | boiler | 173 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow | 5 | 9 | 1 | 31 | 1 |
Geo 5xx | boiler | 173 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus | 5 | 9 | 1 | 32 | 1 |
Geo 5xx | boiler | 173 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff | 5 | 9 | 1 | 33 | 1 |
Geo 5xx | boiler | 173 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle | 5 | 9 | 1 | 34 | 1 |
Geo 5xx | boiler | 173 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp | 5 | 9 | 1/10 | 35 | 1 |
Geo 5xx | boiler | 173 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | 5 | 9 | 1 | 36 | 1 |
Geo 5xx | boiler | 173 | comfort | comfort | enum [hot|eco|intelligent] | | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | 5 | 9 | 1 | 37 | 1 |
Geo 5xx | boiler | 173 | comfort1 | comfort mode | enum [high comfort|eco] | | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | 5 | 9 | 1 | 38 | 1 |
Geo 5xx | boiler | 173 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset | 5 | 9 | 1 | 39 | 1 |
Geo 5xx | boiler | 173 | chargeoptimization | charge optimization | boolean | | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | 5 | 9 | 1 | 40 | 1 |
Geo 5xx | boiler | 173 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower | 5 | 9 | 1 | 41 | 1 |
Geo 5xx | boiler | 173 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp | 5 | 9 | 1 | 42 | 1 |
Geo 5xx | boiler | 173 | circpump | circulation pump available | boolean | | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | 5 | 9 | 1 | 43 | 1 |
Geo 5xx | boiler | 173 | chargetype | charging type | enum [chargepump|3-way valve] | | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | 5 | 9 | 1 | 44 | 1 |
Geo 5xx | boiler | 173 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston | 5 | 9 | 1 | 45 | 1 |
Geo 5xx | boiler | 173 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff | 5 | 9 | 1 | 46 | 1 |
Geo 5xx | boiler | 173 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp | 5 | 9 | 1 | 47 | 1 |
Geo 5xx | boiler | 173 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | 5 | 9 | 1 | 48 | 1 |
Geo 5xx | boiler | 173 | circ | circulation active | boolean | | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | 5 | 9 | 1 | 49 | 1 |
Geo 5xx | boiler | 173 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp | 5 | 9 | 1/10 | 50 | 1 |
Geo 5xx | boiler | 173 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 | 5 | 9 | 1/10 | 51 | 1 |
Geo 5xx | boiler | 173 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow | 5 | 9 | 1/10 | 52 | 1 |
Geo 5xx | boiler | 173 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 | 5 | 9 | 1/10 | 53 | 1 |
Geo 5xx | boiler | 173 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 | 5 | 9 | 1/10 | 54 | 1 |
Geo 5xx | boiler | 173 | activated | activated | boolean | | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | 5 | 9 | 1 | 55 | 1 |
Geo 5xx | boiler | 173 | onetime | one time charging | boolean | | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | 5 | 9 | 1 | 56 | 1 |
Geo 5xx | boiler | 173 | disinfecting | disinfecting | boolean | | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | 5 | 9 | 1 | 57 | 1 |
Geo 5xx | boiler | 173 | charging | charging | boolean | | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | 5 | 9 | 1 | 58 | 1 |
Geo 5xx | boiler | 173 | recharging | recharging | boolean | | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | 5 | 9 | 1 | 59 | 1 |
Geo 5xx | boiler | 173 | tempok | temperature ok | boolean | | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | 5 | 9 | 1 | 60 | 1 |
Geo 5xx | boiler | 173 | active | active | boolean | | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | 5 | 9 | 1 | 61 | 1 |
Geo 5xx | boiler | 173 | 3wayvalve | 3-way valve active | boolean | | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | 5 | 9 | 1 | 62 | 1 |
Geo 5xx | boiler | 173 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp | 5 | 9 | 1/10 | 63 | 1 |
Geo 5xx | boiler | 173 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp | 5 | 9 | 1/10 | 64 | 1 |
Geo 5xx | boiler | 173 | starts | starts | uint24 (>=0<=16777213) | | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | 5 | 9 | 1 | 65 | 2 |
Geo 5xx | boiler | 173 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm | 5 | 9 | 1 | 67 | 2 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | reset | reset | cmd [-|maintenance|error|history|message] | | True | sensor.boiler_reset | sensor.boiler_reset | 5 | 0 | 1 | 0 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | heatingoff | force heating off | boolean | | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | 5 | 0 | 1 | 1 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | heatingactive | heating active | boolean | | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | 5 | 0 | 1 | 2 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | tapwateractive | tapwater active | boolean | | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | 5 | 0 | 1 | 3 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp | 5 | 0 | 1 | 4 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod | 5 | 0 | 1 | 5 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp | 5 | 0 | 1/10 | 6 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp | 5 | 0 | 1/10 | 7 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp | 5 | 0 | 1/10 | 8 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp | 5 | 0 | 1/10 | 9 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress | 5 | 0 | 1/10 | 10 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp | 5 | 0 | 1/10 | 11 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp | 5 | 0 | 1/10 | 12 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp | 5 | 0 | 1/10 | 242 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | burngas | gas | boolean | | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | 5 | 0 | 1 | 243 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | burngas2 | gas stage 2 | boolean | | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | 5 | 0 | 1 | 244 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr | 5 | 0 | 1/10 | 245 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | fanwork | fan | boolean | | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | 5 | 0 | 1 | 246 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | ignwork | ignition | boolean | | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | 5 | 0 | 1 | 247 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | oilpreheat | oil preheating | boolean | | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | 5 | 0 | 1 | 248 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower | 5 | 0 | 1 | 249 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower | 5 | 0 | 1 | 250 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod | 5 | 0 | 1 | 251 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow | 5 | 0 | 1 | 252 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock | 5 | 0 | 1/10 | 253 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston | 5 | 0 | 1 | 254 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff | 5 | 0 | 1 | 255 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston | 5 | 0 | 1 | 256 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff | 5 | 0 | 1 | 257 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | curveon | heatingcurve on | boolean | | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | 5 | 0 | 1 | 258 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase | 5 | 0 | 1 | 259 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend | 5 | 0 | 1 | 260 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | summertemp | summer temperature | uint8 (>=0<=45) | C | True | number.boiler_summer_temperature | number.boiler_summertemp | 5 | 0 | 1 | 261 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | nofrostmode | nofrost mode | boolean | | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | 5 | 0 | 1 | 262 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp | 5 | 0 | 1 | 263 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | heatingactivated | heating activated | boolean | | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | 5 | 0 | 1 | 13 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp | 5 | 0 | 1 | 14 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | heatingpump | heating pump | boolean | | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | 5 | 0 | 1 | 15 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax | 5 | 0 | 1 | 16 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin | 5 | 0 | 1 | 17 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | 5 | 0 | 1 | 18 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | pumpcharacter | boiler pump characteristic | enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] | | True | select.boiler_boiler_pump_characteristic | select.boiler_pumpcharacter | 5 | 0 | 1 | 19 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay | 5 | 0 | 1 | 20 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | pumpontemp | pump logic temperature | uint8 (>=0<=60) | C | True | number.boiler_pump_logic_temperature | number.boiler_pumpontemp | 5 | 0 | 1 | 21 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow | 5 | 0 | 1 | 22 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow | 5 | 0 | 1 | 23 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | burnstarts | burner starts | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | 5 | 0 | 1 | 24 | 2 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin | 5 | 0 | 1 | 26 | 2 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin | 5 | 0 | 1 | 28 | 2 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin | 5 | 0 | 1 | 30 | 2 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | 5 | 0 | 1 | 32 | 2 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime | 5 | 0 | 1 | 34 | 2 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | lastcode | last error code | string | | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | 5 | 0 | 1 | 36 | 28 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | servicecode | service code | string | | False | sensor.boiler_service_code | sensor.boiler_servicecode | 5 | 0 | 1 | 64 | 2 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | servicecodenumber | service code number | uint16 (>=0<=31999) | | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | 5 | 0 | 1 | 66 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | maintenancemessage | maintenance message | string | | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | 5 | 0 | 1 | 67 | 2 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | maintenance | maintenance scheduled | enum [off|time|date|manual] | | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | 5 | 0 | 1 | 69 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime | 5 | 0 | 1 | 70 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | maintenancedate | next maintenance date | string | | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | 5 | 0 | 1 | 71 | 6 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | emergencyops | emergency operation | boolean | | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | 5 | 0 | 1 | 77 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp | 5 | 0 | 1 | 78 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat | 5 | 0 | 1/10 | 91 | 2 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | meter | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meter | 5 | 9 | 1/10 | 2 | 2 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat | 5 | 0 | 1/10 | 264 | 2 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeter | 5 | 9 | 1/10 | 69 | 2 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 | 5 | 0 | 1/10 | 266 | 2 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrg2 | 5 | 9 | 1/10 | 71 | 2 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | tapactivated | turn on/off | boolean | | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | 5 | 9 | 1 | 28 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp | 5 | 9 | 1 | 29 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp | 5 | 9 | 1 | 30 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow | 5 | 9 | 1 | 31 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus | 5 | 9 | 1 | 32 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff | 5 | 9 | 1 | 33 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle | 5 | 9 | 1 | 34 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp | 5 | 9 | 1/10 | 35 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | 5 | 9 | 1 | 36 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | comfort | comfort | enum [hot|eco|intelligent] | | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | 5 | 9 | 1 | 37 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | comfort1 | comfort mode | enum [high comfort|eco] | | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | 5 | 9 | 1 | 38 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset | 5 | 9 | 1 | 39 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | chargeoptimization | charge optimization | boolean | | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | 5 | 9 | 1 | 40 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower | 5 | 9 | 1 | 41 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp | 5 | 9 | 1 | 42 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | circpump | circulation pump available | boolean | | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | 5 | 9 | 1 | 43 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | chargetype | charging type | enum [chargepump|3-way valve] | | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | 5 | 9 | 1 | 44 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston | 5 | 9 | 1 | 45 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff | 5 | 9 | 1 | 46 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp | 5 | 9 | 1 | 47 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | 5 | 9 | 1 | 48 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | circ | circulation active | boolean | | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | 5 | 9 | 1 | 49 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp | 5 | 9 | 1/10 | 50 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 | 5 | 9 | 1/10 | 51 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow | 5 | 9 | 1/10 | 52 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 | 5 | 9 | 1/10 | 53 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 | 5 | 9 | 1/10 | 54 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | activated | activated | boolean | | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | 5 | 9 | 1 | 55 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | onetime | one time charging | boolean | | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | 5 | 9 | 1 | 56 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | disinfecting | disinfecting | boolean | | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | 5 | 9 | 1 | 57 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | charging | charging | boolean | | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | 5 | 9 | 1 | 58 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | recharging | recharging | boolean | | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | 5 | 9 | 1 | 59 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | tempok | temperature ok | boolean | | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | 5 | 9 | 1 | 60 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | active | active | boolean | | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | 5 | 9 | 1 | 61 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | 3wayvalve | 3-way valve active | boolean | | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | 5 | 9 | 1 | 62 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp | 5 | 9 | 1/10 | 63 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp | 5 | 9 | 1/10 | 64 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | starts | starts | uint24 (>=0<=16777213) | | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | 5 | 9 | 1 | 65 | 2 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm | 5 | 9 | 1 | 67 | 2 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower | 5 | 0 | 1 | 268 | 1 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal | 5 | 0 | 1/100 | 79 | 2 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat | 5 | 0 | 1/100 | 81 | 2 |
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 | boiler | 195 | nrg | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrg | 5 | 9 | 1/100 | 0 | 2 |
Logamax U122, Cerapur | boiler | 203 | reset | reset | cmd [-|maintenance|error|history|message] | | True | sensor.boiler_reset | sensor.boiler_reset | 5 | 0 | 1 | 0 | 1 |
Logamax U122, Cerapur | boiler | 203 | heatingoff | force heating off | boolean | | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | 5 | 0 | 1 | 1 | 1 |
Logamax U122, Cerapur | boiler | 203 | heatingactive | heating active | boolean | | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | 5 | 0 | 1 | 2 | 1 |
Logamax U122, Cerapur | boiler | 203 | tapwateractive | tapwater active | boolean | | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | 5 | 0 | 1 | 3 | 1 |
Logamax U122, Cerapur | boiler | 203 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp | 5 | 0 | 1 | 4 | 1 |
Logamax U122, Cerapur | boiler | 203 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod | 5 | 0 | 1 | 5 | 1 |
Logamax U122, Cerapur | boiler | 203 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp | 5 | 0 | 1/10 | 6 | 1 |
Logamax U122, Cerapur | boiler | 203 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp | 5 | 0 | 1/10 | 7 | 1 |
Logamax U122, Cerapur | boiler | 203 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp | 5 | 0 | 1/10 | 8 | 1 |
Logamax U122, Cerapur | boiler | 203 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp | 5 | 0 | 1/10 | 9 | 1 |
Logamax U122, Cerapur | boiler | 203 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress | 5 | 0 | 1/10 | 10 | 1 |
Logamax U122, Cerapur | boiler | 203 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp | 5 | 0 | 1/10 | 11 | 1 |
Logamax U122, Cerapur | boiler | 203 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp | 5 | 0 | 1/10 | 12 | 1 |
Logamax U122, Cerapur | boiler | 203 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp | 5 | 0 | 1/10 | 242 | 1 |
Logamax U122, Cerapur | boiler | 203 | burngas | gas | boolean | | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | 5 | 0 | 1 | 243 | 1 |
Logamax U122, Cerapur | boiler | 203 | burngas2 | gas stage 2 | boolean | | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | 5 | 0 | 1 | 244 | 1 |
Logamax U122, Cerapur | boiler | 203 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr | 5 | 0 | 1/10 | 245 | 1 |
Logamax U122, Cerapur | boiler | 203 | fanwork | fan | boolean | | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | 5 | 0 | 1 | 246 | 1 |
Logamax U122, Cerapur | boiler | 203 | ignwork | ignition | boolean | | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | 5 | 0 | 1 | 247 | 1 |
Logamax U122, Cerapur | boiler | 203 | oilpreheat | oil preheating | boolean | | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | 5 | 0 | 1 | 248 | 1 |
Logamax U122, Cerapur | boiler | 203 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower | 5 | 0 | 1 | 249 | 1 |
Logamax U122, Cerapur | boiler | 203 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower | 5 | 0 | 1 | 250 | 1 |
Logamax U122, Cerapur | boiler | 203 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod | 5 | 0 | 1 | 251 | 1 |
Logamax U122, Cerapur | boiler | 203 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow | 5 | 0 | 1 | 252 | 1 |
Logamax U122, Cerapur | boiler | 203 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock | 5 | 0 | 1/10 | 253 | 1 |
Logamax U122, Cerapur | boiler | 203 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston | 5 | 0 | 1 | 254 | 1 |
Logamax U122, Cerapur | boiler | 203 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff | 5 | 0 | 1 | 255 | 1 |
Logamax U122, Cerapur | boiler | 203 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston | 5 | 0 | 1 | 256 | 1 |
Logamax U122, Cerapur | boiler | 203 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff | 5 | 0 | 1 | 257 | 1 |
Logamax U122, Cerapur | boiler | 203 | curveon | heatingcurve on | boolean | | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | 5 | 0 | 1 | 258 | 1 |
Logamax U122, Cerapur | boiler | 203 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase | 5 | 0 | 1 | 259 | 1 |
Logamax U122, Cerapur | boiler | 203 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend | 5 | 0 | 1 | 260 | 1 |
Logamax U122, Cerapur | boiler | 203 | summertemp | summer temperature | uint8 (>=0<=45) | C | True | number.boiler_summer_temperature | number.boiler_summertemp | 5 | 0 | 1 | 261 | 1 |
Logamax U122, Cerapur | boiler | 203 | nofrostmode | nofrost mode | boolean | | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | 5 | 0 | 1 | 262 | 1 |
Logamax U122, Cerapur | boiler | 203 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp | 5 | 0 | 1 | 263 | 1 |
Logamax U122, Cerapur | boiler | 203 | heatingactivated | heating activated | boolean | | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | 5 | 0 | 1 | 13 | 1 |
Logamax U122, Cerapur | boiler | 203 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp | 5 | 0 | 1 | 14 | 1 |
Logamax U122, Cerapur | boiler | 203 | heatingpump | heating pump | boolean | | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | 5 | 0 | 1 | 15 | 1 |
Logamax U122, Cerapur | boiler | 203 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax | 5 | 0 | 1 | 16 | 1 |
Logamax U122, Cerapur | boiler | 203 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin | 5 | 0 | 1 | 17 | 1 |
Logamax U122, Cerapur | boiler | 203 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | 5 | 0 | 1 | 18 | 1 |
Logamax U122, Cerapur | boiler | 203 | pumpcharacter | boiler pump characteristic | enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] | | True | select.boiler_boiler_pump_characteristic | select.boiler_pumpcharacter | 5 | 0 | 1 | 19 | 1 |
Logamax U122, Cerapur | boiler | 203 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay | 5 | 0 | 1 | 20 | 1 |
Logamax U122, Cerapur | boiler | 203 | pumpontemp | pump logic temperature | uint8 (>=0<=60) | C | True | number.boiler_pump_logic_temperature | number.boiler_pumpontemp | 5 | 0 | 1 | 21 | 1 |
Logamax U122, Cerapur | boiler | 203 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow | 5 | 0 | 1 | 22 | 1 |
Logamax U122, Cerapur | boiler | 203 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow | 5 | 0 | 1 | 23 | 1 |
Logamax U122, Cerapur | boiler | 203 | burnstarts | burner starts | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | 5 | 0 | 1 | 24 | 2 |
Logamax U122, Cerapur | boiler | 203 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin | 5 | 0 | 1 | 26 | 2 |
Logamax U122, Cerapur | boiler | 203 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin | 5 | 0 | 1 | 28 | 2 |
Logamax U122, Cerapur | boiler | 203 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin | 5 | 0 | 1 | 30 | 2 |
Logamax U122, Cerapur | boiler | 203 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | 5 | 0 | 1 | 32 | 2 |
Logamax U122, Cerapur | boiler | 203 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime | 5 | 0 | 1 | 34 | 2 |
Logamax U122, Cerapur | boiler | 203 | lastcode | last error code | string | | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | 5 | 0 | 1 | 36 | 28 |
Logamax U122, Cerapur | boiler | 203 | servicecode | service code | string | | False | sensor.boiler_service_code | sensor.boiler_servicecode | 5 | 0 | 1 | 64 | 2 |
Logamax U122, Cerapur | boiler | 203 | servicecodenumber | service code number | uint16 (>=0<=31999) | | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | 5 | 0 | 1 | 66 | 1 |
Logamax U122, Cerapur | boiler | 203 | maintenancemessage | maintenance message | string | | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | 5 | 0 | 1 | 67 | 2 |
Logamax U122, Cerapur | boiler | 203 | maintenance | maintenance scheduled | enum [off|time|date|manual] | | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | 5 | 0 | 1 | 69 | 1 |
Logamax U122, Cerapur | boiler | 203 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime | 5 | 0 | 1 | 70 | 1 |
Logamax U122, Cerapur | boiler | 203 | maintenancedate | next maintenance date | string | | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | 5 | 0 | 1 | 71 | 6 |
Logamax U122, Cerapur | boiler | 203 | emergencyops | emergency operation | boolean | | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | 5 | 0 | 1 | 77 | 1 |
Logamax U122, Cerapur | boiler | 203 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp | 5 | 0 | 1 | 78 | 1 |
Logamax U122, Cerapur | boiler | 203 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat | 5 | 0 | 1/10 | 91 | 2 |
Logamax U122, Cerapur | boiler | 203 | meter | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meter | 5 | 9 | 1/10 | 2 | 2 |
Logamax U122, Cerapur | boiler | 203 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat | 5 | 0 | 1/10 | 264 | 2 |
Logamax U122, Cerapur | boiler | 203 | gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeter | 5 | 9 | 1/10 | 69 | 2 |
Logamax U122, Cerapur | boiler | 203 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 | 5 | 0 | 1/10 | 266 | 2 |
Logamax U122, Cerapur | boiler | 203 | nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrg2 | 5 | 9 | 1/10 | 71 | 2 |
Logamax U122, Cerapur | boiler | 203 | tapactivated | turn on/off | boolean | | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | 5 | 9 | 1 | 28 | 1 |
Logamax U122, Cerapur | boiler | 203 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp | 5 | 9 | 1 | 29 | 1 |
Logamax U122, Cerapur | boiler | 203 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp | 5 | 9 | 1 | 30 | 1 |
Logamax U122, Cerapur | boiler | 203 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow | 5 | 9 | 1 | 31 | 1 |
Logamax U122, Cerapur | boiler | 203 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus | 5 | 9 | 1 | 32 | 1 |
Logamax U122, Cerapur | boiler | 203 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff | 5 | 9 | 1 | 33 | 1 |
Logamax U122, Cerapur | boiler | 203 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle | 5 | 9 | 1 | 34 | 1 |
Logamax U122, Cerapur | boiler | 203 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp | 5 | 9 | 1/10 | 35 | 1 |
Logamax U122, Cerapur | boiler | 203 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | 5 | 9 | 1 | 36 | 1 |
Logamax U122, Cerapur | boiler | 203 | comfort | comfort | enum [hot|eco|intelligent] | | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | 5 | 9 | 1 | 37 | 1 |
Logamax U122, Cerapur | boiler | 203 | comfort1 | comfort mode | enum [high comfort|eco] | | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | 5 | 9 | 1 | 38 | 1 |
Logamax U122, Cerapur | boiler | 203 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset | 5 | 9 | 1 | 39 | 1 |
Logamax U122, Cerapur | boiler | 203 | chargeoptimization | charge optimization | boolean | | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | 5 | 9 | 1 | 40 | 1 |
Logamax U122, Cerapur | boiler | 203 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower | 5 | 9 | 1 | 41 | 1 |
Logamax U122, Cerapur | boiler | 203 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp | 5 | 9 | 1 | 42 | 1 |
Logamax U122, Cerapur | boiler | 203 | circpump | circulation pump available | boolean | | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | 5 | 9 | 1 | 43 | 1 |
Logamax U122, Cerapur | boiler | 203 | chargetype | charging type | enum [chargepump|3-way valve] | | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | 5 | 9 | 1 | 44 | 1 |
Logamax U122, Cerapur | boiler | 203 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston | 5 | 9 | 1 | 45 | 1 |
Logamax U122, Cerapur | boiler | 203 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff | 5 | 9 | 1 | 46 | 1 |
Logamax U122, Cerapur | boiler | 203 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp | 5 | 9 | 1 | 47 | 1 |
Logamax U122, Cerapur | boiler | 203 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | 5 | 9 | 1 | 48 | 1 |
Logamax U122, Cerapur | boiler | 203 | circ | circulation active | boolean | | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | 5 | 9 | 1 | 49 | 1 |
Logamax U122, Cerapur | boiler | 203 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp | 5 | 9 | 1/10 | 50 | 1 |
Logamax U122, Cerapur | boiler | 203 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 | 5 | 9 | 1/10 | 51 | 1 |
Logamax U122, Cerapur | boiler | 203 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow | 5 | 9 | 1/10 | 52 | 1 |
Logamax U122, Cerapur | boiler | 203 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 | 5 | 9 | 1/10 | 53 | 1 |
Logamax U122, Cerapur | boiler | 203 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 | 5 | 9 | 1/10 | 54 | 1 |
Logamax U122, Cerapur | boiler | 203 | activated | activated | boolean | | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | 5 | 9 | 1 | 55 | 1 |
Logamax U122, Cerapur | boiler | 203 | onetime | one time charging | boolean | | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | 5 | 9 | 1 | 56 | 1 |
Logamax U122, Cerapur | boiler | 203 | disinfecting | disinfecting | boolean | | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | 5 | 9 | 1 | 57 | 1 |
Logamax U122, Cerapur | boiler | 203 | charging | charging | boolean | | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | 5 | 9 | 1 | 58 | 1 |
Logamax U122, Cerapur | boiler | 203 | recharging | recharging | boolean | | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | 5 | 9 | 1 | 59 | 1 |
Logamax U122, Cerapur | boiler | 203 | tempok | temperature ok | boolean | | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | 5 | 9 | 1 | 60 | 1 |
Logamax U122, Cerapur | boiler | 203 | active | active | boolean | | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | 5 | 9 | 1 | 61 | 1 |
Logamax U122, Cerapur | boiler | 203 | 3wayvalve | 3-way valve active | boolean | | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | 5 | 9 | 1 | 62 | 1 |
Logamax U122, Cerapur | boiler | 203 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp | 5 | 9 | 1/10 | 63 | 1 |
Logamax U122, Cerapur | boiler | 203 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp | 5 | 9 | 1/10 | 64 | 1 |
Logamax U122, Cerapur | boiler | 203 | starts | starts | uint24 (>=0<=16777213) | | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | 5 | 9 | 1 | 65 | 2 |
Logamax U122, Cerapur | boiler | 203 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm | 5 | 9 | 1 | 67 | 2 |
Logamax U122, Cerapur | boiler | 203 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower | 5 | 0 | 1 | 268 | 1 |
Logamax U122, Cerapur | boiler | 203 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal | 5 | 0 | 1/100 | 79 | 2 |
Logamax U122, Cerapur | boiler | 203 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat | 5 | 0 | 1/100 | 81 | 2 |
Logamax U122, Cerapur | boiler | 203 | nrg | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrg | 5 | 9 | 1/100 | 0 | 2 |
Ecomline Excellent | boiler | 206 | reset | reset | cmd [-|maintenance|error|history|message] | | True | sensor.boiler_reset | sensor.boiler_reset | 5 | 0 | 1 | 0 | 1 |
Ecomline Excellent | boiler | 206 | heatingoff | force heating off | boolean | | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | 5 | 0 | 1 | 1 | 1 |
Ecomline Excellent | boiler | 206 | heatingactive | heating active | boolean | | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | 5 | 0 | 1 | 2 | 1 |
Ecomline Excellent | boiler | 206 | tapwateractive | tapwater active | boolean | | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | 5 | 0 | 1 | 3 | 1 |
Ecomline Excellent | boiler | 206 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp | 5 | 0 | 1 | 4 | 1 |
Ecomline Excellent | boiler | 206 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod | 5 | 0 | 1 | 5 | 1 |
Ecomline Excellent | boiler | 206 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp | 5 | 0 | 1/10 | 6 | 1 |
Ecomline Excellent | boiler | 206 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp | 5 | 0 | 1/10 | 7 | 1 |
Ecomline Excellent | boiler | 206 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp | 5 | 0 | 1/10 | 8 | 1 |
Ecomline Excellent | boiler | 206 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp | 5 | 0 | 1/10 | 9 | 1 |
Ecomline Excellent | boiler | 206 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress | 5 | 0 | 1/10 | 10 | 1 |
Ecomline Excellent | boiler | 206 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp | 5 | 0 | 1/10 | 11 | 1 |
Ecomline Excellent | boiler | 206 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp | 5 | 0 | 1/10 | 12 | 1 |
Ecomline Excellent | boiler | 206 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp | 5 | 0 | 1/10 | 242 | 1 |
Ecomline Excellent | boiler | 206 | burngas | gas | boolean | | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | 5 | 0 | 1 | 243 | 1 |
Ecomline Excellent | boiler | 206 | burngas2 | gas stage 2 | boolean | | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | 5 | 0 | 1 | 244 | 1 |
Ecomline Excellent | boiler | 206 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr | 5 | 0 | 1/10 | 245 | 1 |
Ecomline Excellent | boiler | 206 | fanwork | fan | boolean | | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | 5 | 0 | 1 | 246 | 1 |
Ecomline Excellent | boiler | 206 | ignwork | ignition | boolean | | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | 5 | 0 | 1 | 247 | 1 |
Ecomline Excellent | boiler | 206 | oilpreheat | oil preheating | boolean | | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | 5 | 0 | 1 | 248 | 1 |
Ecomline Excellent | boiler | 206 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower | 5 | 0 | 1 | 249 | 1 |
Ecomline Excellent | boiler | 206 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower | 5 | 0 | 1 | 250 | 1 |
Ecomline Excellent | boiler | 206 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod | 5 | 0 | 1 | 251 | 1 |
Ecomline Excellent | boiler | 206 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow | 5 | 0 | 1 | 252 | 1 |
Ecomline Excellent | boiler | 206 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock | 5 | 0 | 1/10 | 253 | 1 |
Ecomline Excellent | boiler | 206 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston | 5 | 0 | 1 | 254 | 1 |
Ecomline Excellent | boiler | 206 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff | 5 | 0 | 1 | 255 | 1 |
Ecomline Excellent | boiler | 206 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston | 5 | 0 | 1 | 256 | 1 |
Ecomline Excellent | boiler | 206 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff | 5 | 0 | 1 | 257 | 1 |
Ecomline Excellent | boiler | 206 | curveon | heatingcurve on | boolean | | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | 5 | 0 | 1 | 258 | 1 |
Ecomline Excellent | boiler | 206 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase | 5 | 0 | 1 | 259 | 1 |
Ecomline Excellent | boiler | 206 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend | 5 | 0 | 1 | 260 | 1 |
Ecomline Excellent | boiler | 206 | summertemp | summer temperature | uint8 (>=0<=45) | C | True | number.boiler_summer_temperature | number.boiler_summertemp | 5 | 0 | 1 | 261 | 1 |
Ecomline Excellent | boiler | 206 | nofrostmode | nofrost mode | boolean | | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | 5 | 0 | 1 | 262 | 1 |
Ecomline Excellent | boiler | 206 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp | 5 | 0 | 1 | 263 | 1 |
Ecomline Excellent | boiler | 206 | heatingactivated | heating activated | boolean | | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | 5 | 0 | 1 | 13 | 1 |
Ecomline Excellent | boiler | 206 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp | 5 | 0 | 1 | 14 | 1 |
Ecomline Excellent | boiler | 206 | heatingpump | heating pump | boolean | | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | 5 | 0 | 1 | 15 | 1 |
Ecomline Excellent | boiler | 206 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax | 5 | 0 | 1 | 16 | 1 |
Ecomline Excellent | boiler | 206 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin | 5 | 0 | 1 | 17 | 1 |
Ecomline Excellent | boiler | 206 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | 5 | 0 | 1 | 18 | 1 |
Ecomline Excellent | boiler | 206 | pumpcharacter | boiler pump characteristic | enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] | | True | select.boiler_boiler_pump_characteristic | select.boiler_pumpcharacter | 5 | 0 | 1 | 19 | 1 |
Ecomline Excellent | boiler | 206 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay | 5 | 0 | 1 | 20 | 1 |
Ecomline Excellent | boiler | 206 | pumpontemp | pump logic temperature | uint8 (>=0<=60) | C | True | number.boiler_pump_logic_temperature | number.boiler_pumpontemp | 5 | 0 | 1 | 21 | 1 |
Ecomline Excellent | boiler | 206 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow | 5 | 0 | 1 | 22 | 1 |
Ecomline Excellent | boiler | 206 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow | 5 | 0 | 1 | 23 | 1 |
Ecomline Excellent | boiler | 206 | burnstarts | burner starts | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | 5 | 0 | 1 | 24 | 2 |
Ecomline Excellent | boiler | 206 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin | 5 | 0 | 1 | 26 | 2 |
Ecomline Excellent | boiler | 206 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin | 5 | 0 | 1 | 28 | 2 |
Ecomline Excellent | boiler | 206 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin | 5 | 0 | 1 | 30 | 2 |
Ecomline Excellent | boiler | 206 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | 5 | 0 | 1 | 32 | 2 |
Ecomline Excellent | boiler | 206 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime | 5 | 0 | 1 | 34 | 2 |
Ecomline Excellent | boiler | 206 | lastcode | last error code | string | | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | 5 | 0 | 1 | 36 | 28 |
Ecomline Excellent | boiler | 206 | servicecode | service code | string | | False | sensor.boiler_service_code | sensor.boiler_servicecode | 5 | 0 | 1 | 64 | 2 |
Ecomline Excellent | boiler | 206 | servicecodenumber | service code number | uint16 (>=0<=31999) | | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | 5 | 0 | 1 | 66 | 1 |
Ecomline Excellent | boiler | 206 | maintenancemessage | maintenance message | string | | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | 5 | 0 | 1 | 67 | 2 |
Ecomline Excellent | boiler | 206 | maintenance | maintenance scheduled | enum [off|time|date|manual] | | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | 5 | 0 | 1 | 69 | 1 |
Ecomline Excellent | boiler | 206 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime | 5 | 0 | 1 | 70 | 1 |
Ecomline Excellent | boiler | 206 | maintenancedate | next maintenance date | string | | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | 5 | 0 | 1 | 71 | 6 |
Ecomline Excellent | boiler | 206 | emergencyops | emergency operation | boolean | | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | 5 | 0 | 1 | 77 | 1 |
Ecomline Excellent | boiler | 206 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp | 5 | 0 | 1 | 78 | 1 |
Ecomline Excellent | boiler | 206 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat | 5 | 0 | 1/10 | 91 | 2 |
Ecomline Excellent | boiler | 206 | meter | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meter | 5 | 9 | 1/10 | 2 | 2 |
Ecomline Excellent | boiler | 206 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat | 5 | 0 | 1/10 | 264 | 2 |
Ecomline Excellent | boiler | 206 | gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeter | 5 | 9 | 1/10 | 69 | 2 |
Ecomline Excellent | boiler | 206 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 | 5 | 0 | 1/10 | 266 | 2 |
Ecomline Excellent | boiler | 206 | nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrg2 | 5 | 9 | 1/10 | 71 | 2 |
Ecomline Excellent | boiler | 206 | tapactivated | turn on/off | boolean | | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | 5 | 9 | 1 | 28 | 1 |
Ecomline Excellent | boiler | 206 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp | 5 | 9 | 1 | 29 | 1 |
Ecomline Excellent | boiler | 206 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp | 5 | 9 | 1 | 30 | 1 |
Ecomline Excellent | boiler | 206 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow | 5 | 9 | 1 | 31 | 1 |
Ecomline Excellent | boiler | 206 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus | 5 | 9 | 1 | 32 | 1 |
Ecomline Excellent | boiler | 206 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff | 5 | 9 | 1 | 33 | 1 |
Ecomline Excellent | boiler | 206 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle | 5 | 9 | 1 | 34 | 1 |
Ecomline Excellent | boiler | 206 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp | 5 | 9 | 1/10 | 35 | 1 |
Ecomline Excellent | boiler | 206 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | 5 | 9 | 1 | 36 | 1 |
Ecomline Excellent | boiler | 206 | comfort | comfort | enum [hot|eco|intelligent] | | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | 5 | 9 | 1 | 37 | 1 |
Ecomline Excellent | boiler | 206 | comfort1 | comfort mode | enum [high comfort|eco] | | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | 5 | 9 | 1 | 38 | 1 |
Ecomline Excellent | boiler | 206 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset | 5 | 9 | 1 | 39 | 1 |
Ecomline Excellent | boiler | 206 | chargeoptimization | charge optimization | boolean | | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | 5 | 9 | 1 | 40 | 1 |
Ecomline Excellent | boiler | 206 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower | 5 | 9 | 1 | 41 | 1 |
Ecomline Excellent | boiler | 206 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp | 5 | 9 | 1 | 42 | 1 |
Ecomline Excellent | boiler | 206 | circpump | circulation pump available | boolean | | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | 5 | 9 | 1 | 43 | 1 |
Ecomline Excellent | boiler | 206 | chargetype | charging type | enum [chargepump|3-way valve] | | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | 5 | 9 | 1 | 44 | 1 |
Ecomline Excellent | boiler | 206 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston | 5 | 9 | 1 | 45 | 1 |
Ecomline Excellent | boiler | 206 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff | 5 | 9 | 1 | 46 | 1 |
Ecomline Excellent | boiler | 206 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp | 5 | 9 | 1 | 47 | 1 |
Ecomline Excellent | boiler | 206 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | 5 | 9 | 1 | 48 | 1 |
Ecomline Excellent | boiler | 206 | circ | circulation active | boolean | | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | 5 | 9 | 1 | 49 | 1 |
Ecomline Excellent | boiler | 206 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp | 5 | 9 | 1/10 | 50 | 1 |
Ecomline Excellent | boiler | 206 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 | 5 | 9 | 1/10 | 51 | 1 |
Ecomline Excellent | boiler | 206 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow | 5 | 9 | 1/10 | 52 | 1 |
Ecomline Excellent | boiler | 206 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 | 5 | 9 | 1/10 | 53 | 1 |
Ecomline Excellent | boiler | 206 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 | 5 | 9 | 1/10 | 54 | 1 |
Ecomline Excellent | boiler | 206 | activated | activated | boolean | | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | 5 | 9 | 1 | 55 | 1 |
Ecomline Excellent | boiler | 206 | onetime | one time charging | boolean | | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | 5 | 9 | 1 | 56 | 1 |
Ecomline Excellent | boiler | 206 | disinfecting | disinfecting | boolean | | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | 5 | 9 | 1 | 57 | 1 |
Ecomline Excellent | boiler | 206 | charging | charging | boolean | | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | 5 | 9 | 1 | 58 | 1 |
Ecomline Excellent | boiler | 206 | recharging | recharging | boolean | | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | 5 | 9 | 1 | 59 | 1 |
Ecomline Excellent | boiler | 206 | tempok | temperature ok | boolean | | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | 5 | 9 | 1 | 60 | 1 |
Ecomline Excellent | boiler | 206 | active | active | boolean | | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | 5 | 9 | 1 | 61 | 1 |
Ecomline Excellent | boiler | 206 | 3wayvalve | 3-way valve active | boolean | | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | 5 | 9 | 1 | 62 | 1 |
Ecomline Excellent | boiler | 206 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp | 5 | 9 | 1/10 | 63 | 1 |
Ecomline Excellent | boiler | 206 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp | 5 | 9 | 1/10 | 64 | 1 |
Ecomline Excellent | boiler | 206 | starts | starts | uint24 (>=0<=16777213) | | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | 5 | 9 | 1 | 65 | 2 |
Ecomline Excellent | boiler | 206 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm | 5 | 9 | 1 | 67 | 2 |
Ecomline Excellent | boiler | 206 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower | 5 | 0 | 1 | 268 | 1 |
Ecomline Excellent | boiler | 206 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal | 5 | 0 | 1/100 | 79 | 2 |
Ecomline Excellent | boiler | 206 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat | 5 | 0 | 1/100 | 81 | 2 |
Ecomline Excellent | boiler | 206 | nrg | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrg | 5 | 9 | 1/100 | 0 | 2 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | reset | reset | cmd [-|maintenance|error|history|message] | | True | sensor.boiler_reset | sensor.boiler_reset | 5 | 0 | 1 | 0 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | heatingoff | force heating off | boolean | | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | 5 | 0 | 1 | 1 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | heatingactive | heating active | boolean | | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | 5 | 0 | 1 | 2 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | tapwateractive | tapwater active | boolean | | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | 5 | 0 | 1 | 3 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp | 5 | 0 | 1 | 4 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod | 5 | 0 | 1 | 5 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp | 5 | 0 | 1/10 | 6 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp | 5 | 0 | 1/10 | 7 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp | 5 | 0 | 1/10 | 8 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp | 5 | 0 | 1/10 | 9 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress | 5 | 0 | 1/10 | 10 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp | 5 | 0 | 1/10 | 11 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp | 5 | 0 | 1/10 | 12 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp | 5 | 0 | 1/10 | 242 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | burngas | gas | boolean | | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | 5 | 0 | 1 | 243 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | burngas2 | gas stage 2 | boolean | | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | 5 | 0 | 1 | 244 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr | 5 | 0 | 1/10 | 245 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | fanwork | fan | boolean | | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | 5 | 0 | 1 | 246 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | ignwork | ignition | boolean | | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | 5 | 0 | 1 | 247 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | oilpreheat | oil preheating | boolean | | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | 5 | 0 | 1 | 248 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower | 5 | 0 | 1 | 249 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower | 5 | 0 | 1 | 250 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod | 5 | 0 | 1 | 251 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow | 5 | 0 | 1 | 252 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock | 5 | 0 | 1/10 | 253 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston | 5 | 0 | 1 | 254 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff | 5 | 0 | 1 | 255 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston | 5 | 0 | 1 | 256 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff | 5 | 0 | 1 | 257 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | curveon | heatingcurve on | boolean | | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | 5 | 0 | 1 | 258 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase | 5 | 0 | 1 | 259 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend | 5 | 0 | 1 | 260 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | summertemp | summer temperature | uint8 (>=0<=45) | C | True | number.boiler_summer_temperature | number.boiler_summertemp | 5 | 0 | 1 | 261 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | nofrostmode | nofrost mode | boolean | | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | 5 | 0 | 1 | 262 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp | 5 | 0 | 1 | 263 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | heatingactivated | heating activated | boolean | | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | 5 | 0 | 1 | 13 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp | 5 | 0 | 1 | 14 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | heatingpump | heating pump | boolean | | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | 5 | 0 | 1 | 15 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax | 5 | 0 | 1 | 16 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin | 5 | 0 | 1 | 17 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | 5 | 0 | 1 | 18 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | pumpcharacter | boiler pump characteristic | enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] | | True | select.boiler_boiler_pump_characteristic | select.boiler_pumpcharacter | 5 | 0 | 1 | 19 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay | 5 | 0 | 1 | 20 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | pumpontemp | pump logic temperature | uint8 (>=0<=60) | C | True | number.boiler_pump_logic_temperature | number.boiler_pumpontemp | 5 | 0 | 1 | 21 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow | 5 | 0 | 1 | 22 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow | 5 | 0 | 1 | 23 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | burnstarts | burner starts | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | 5 | 0 | 1 | 24 | 2 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin | 5 | 0 | 1 | 26 | 2 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin | 5 | 0 | 1 | 28 | 2 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin | 5 | 0 | 1 | 30 | 2 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | 5 | 0 | 1 | 32 | 2 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime | 5 | 0 | 1 | 34 | 2 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | lastcode | last error code | string | | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | 5 | 0 | 1 | 36 | 28 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | servicecode | service code | string | | False | sensor.boiler_service_code | sensor.boiler_servicecode | 5 | 0 | 1 | 64 | 2 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | servicecodenumber | service code number | uint16 (>=0<=31999) | | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | 5 | 0 | 1 | 66 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | maintenancemessage | maintenance message | string | | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | 5 | 0 | 1 | 67 | 2 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | maintenance | maintenance scheduled | enum [off|time|date|manual] | | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | 5 | 0 | 1 | 69 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime | 5 | 0 | 1 | 70 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | maintenancedate | next maintenance date | string | | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | 5 | 0 | 1 | 71 | 6 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | emergencyops | emergency operation | boolean | | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | 5 | 0 | 1 | 77 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp | 5 | 0 | 1 | 78 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat | 5 | 0 | 1/10 | 91 | 2 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | meter | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meter | 5 | 9 | 1/10 | 2 | 2 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat | 5 | 0 | 1/10 | 264 | 2 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeter | 5 | 9 | 1/10 | 69 | 2 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 | 5 | 0 | 1/10 | 266 | 2 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrg2 | 5 | 9 | 1/10 | 71 | 2 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | tapactivated | turn on/off | boolean | | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | 5 | 9 | 1 | 28 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp | 5 | 9 | 1 | 29 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp | 5 | 9 | 1 | 30 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow | 5 | 9 | 1 | 31 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus | 5 | 9 | 1 | 32 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff | 5 | 9 | 1 | 33 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle | 5 | 9 | 1 | 34 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp | 5 | 9 | 1/10 | 35 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | 5 | 9 | 1 | 36 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | comfort | comfort | enum [hot|eco|intelligent] | | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | 5 | 9 | 1 | 37 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | comfort1 | comfort mode | enum [high comfort|eco] | | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | 5 | 9 | 1 | 38 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset | 5 | 9 | 1 | 39 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | chargeoptimization | charge optimization | boolean | | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | 5 | 9 | 1 | 40 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower | 5 | 9 | 1 | 41 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp | 5 | 9 | 1 | 42 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | circpump | circulation pump available | boolean | | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | 5 | 9 | 1 | 43 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | chargetype | charging type | enum [chargepump|3-way valve] | | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | 5 | 9 | 1 | 44 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston | 5 | 9 | 1 | 45 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff | 5 | 9 | 1 | 46 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp | 5 | 9 | 1 | 47 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | 5 | 9 | 1 | 48 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | circ | circulation active | boolean | | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | 5 | 9 | 1 | 49 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp | 5 | 9 | 1/10 | 50 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 | 5 | 9 | 1/10 | 51 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow | 5 | 9 | 1/10 | 52 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 | 5 | 9 | 1/10 | 53 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 | 5 | 9 | 1/10 | 54 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | activated | activated | boolean | | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | 5 | 9 | 1 | 55 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | onetime | one time charging | boolean | | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | 5 | 9 | 1 | 56 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | disinfecting | disinfecting | boolean | | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | 5 | 9 | 1 | 57 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | charging | charging | boolean | | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | 5 | 9 | 1 | 58 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | recharging | recharging | boolean | | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | 5 | 9 | 1 | 59 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | tempok | temperature ok | boolean | | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | 5 | 9 | 1 | 60 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | active | active | boolean | | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | 5 | 9 | 1 | 61 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | 3wayvalve | 3-way valve active | boolean | | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | 5 | 9 | 1 | 62 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp | 5 | 9 | 1/10 | 63 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp | 5 | 9 | 1/10 | 64 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | starts | starts | uint24 (>=0<=16777213) | | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | 5 | 9 | 1 | 65 | 2 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm | 5 | 9 | 1 | 67 | 2 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower | 5 | 0 | 1 | 268 | 1 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal | 5 | 0 | 1/100 | 79 | 2 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat | 5 | 0 | 1/100 | 81 | 2 |
Logamax Plus, GB192, Condens GC9000, Greenstar ErP | boiler | 208 | nrg | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrg | 5 | 9 | 1/100 | 0 | 2 |
Cascade MC400 | boiler | 210 | reset | reset | cmd [-|maintenance|error|history|message] | | True | sensor.boiler_reset | sensor.boiler_reset | 5 | 0 | 1 | 0 | 1 |
Cascade MC400 | boiler | 210 | heatingoff | force heating off | boolean | | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | 5 | 0 | 1 | 1 | 1 |
Cascade MC400 | boiler | 210 | heatingactive | heating active | boolean | | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | 5 | 0 | 1 | 2 | 1 |
Cascade MC400 | boiler | 210 | tapwateractive | tapwater active | boolean | | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | 5 | 0 | 1 | 3 | 1 |
Cascade MC400 | boiler | 210 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp | 5 | 0 | 1 | 4 | 1 |
Cascade MC400 | boiler | 210 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod | 5 | 0 | 1 | 5 | 1 |
Cascade MC400 | boiler | 210 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp | 5 | 0 | 1/10 | 6 | 1 |
Cascade MC400 | boiler | 210 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp | 5 | 0 | 1/10 | 7 | 1 |
Cascade MC400 | boiler | 210 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp | 5 | 0 | 1/10 | 8 | 1 |
Cascade MC400 | boiler | 210 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp | 5 | 0 | 1/10 | 9 | 1 |
Cascade MC400 | boiler | 210 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress | 5 | 0 | 1/10 | 10 | 1 |
Cascade MC400 | boiler | 210 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp | 5 | 0 | 1/10 | 11 | 1 |
Cascade MC400 | boiler | 210 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp | 5 | 0 | 1/10 | 12 | 1 |
Cascade MC400 | boiler | 210 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp | 5 | 0 | 1/10 | 242 | 1 |
Cascade MC400 | boiler | 210 | burngas | gas | boolean | | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | 5 | 0 | 1 | 243 | 1 |
Cascade MC400 | boiler | 210 | burngas2 | gas stage 2 | boolean | | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | 5 | 0 | 1 | 244 | 1 |
Cascade MC400 | boiler | 210 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr | 5 | 0 | 1/10 | 245 | 1 |
Cascade MC400 | boiler | 210 | fanwork | fan | boolean | | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | 5 | 0 | 1 | 246 | 1 |
Cascade MC400 | boiler | 210 | ignwork | ignition | boolean | | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | 5 | 0 | 1 | 247 | 1 |
Cascade MC400 | boiler | 210 | oilpreheat | oil preheating | boolean | | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | 5 | 0 | 1 | 248 | 1 |
Cascade MC400 | boiler | 210 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower | 5 | 0 | 1 | 249 | 1 |
Cascade MC400 | boiler | 210 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower | 5 | 0 | 1 | 250 | 1 |
Cascade MC400 | boiler | 210 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod | 5 | 0 | 1 | 251 | 1 |
Cascade MC400 | boiler | 210 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow | 5 | 0 | 1 | 252 | 1 |
Cascade MC400 | boiler | 210 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock | 5 | 0 | 1/10 | 253 | 1 |
Cascade MC400 | boiler | 210 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston | 5 | 0 | 1 | 254 | 1 |
Cascade MC400 | boiler | 210 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff | 5 | 0 | 1 | 255 | 1 |
Cascade MC400 | boiler | 210 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston | 5 | 0 | 1 | 256 | 1 |
Cascade MC400 | boiler | 210 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff | 5 | 0 | 1 | 257 | 1 |
Cascade MC400 | boiler | 210 | curveon | heatingcurve on | boolean | | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | 5 | 0 | 1 | 258 | 1 |
Cascade MC400 | boiler | 210 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase | 5 | 0 | 1 | 259 | 1 |
Cascade MC400 | boiler | 210 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend | 5 | 0 | 1 | 260 | 1 |
Cascade MC400 | boiler | 210 | summertemp | summer temperature | uint8 (>=0<=45) | C | True | number.boiler_summer_temperature | number.boiler_summertemp | 5 | 0 | 1 | 261 | 1 |
Cascade MC400 | boiler | 210 | nofrostmode | nofrost mode | boolean | | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | 5 | 0 | 1 | 262 | 1 |
Cascade MC400 | boiler | 210 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp | 5 | 0 | 1 | 263 | 1 |
Cascade MC400 | boiler | 210 | heatingactivated | heating activated | boolean | | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | 5 | 0 | 1 | 13 | 1 |
Cascade MC400 | boiler | 210 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp | 5 | 0 | 1 | 14 | 1 |
Cascade MC400 | boiler | 210 | heatingpump | heating pump | boolean | | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | 5 | 0 | 1 | 15 | 1 |
Cascade MC400 | boiler | 210 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax | 5 | 0 | 1 | 16 | 1 |
Cascade MC400 | boiler | 210 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin | 5 | 0 | 1 | 17 | 1 |
Cascade MC400 | boiler | 210 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | 5 | 0 | 1 | 18 | 1 |
Cascade MC400 | boiler | 210 | pumpcharacter | boiler pump characteristic | enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] | | True | select.boiler_boiler_pump_characteristic | select.boiler_pumpcharacter | 5 | 0 | 1 | 19 | 1 |
Cascade MC400 | boiler | 210 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay | 5 | 0 | 1 | 20 | 1 |
Cascade MC400 | boiler | 210 | pumpontemp | pump logic temperature | uint8 (>=0<=60) | C | True | number.boiler_pump_logic_temperature | number.boiler_pumpontemp | 5 | 0 | 1 | 21 | 1 |
Cascade MC400 | boiler | 210 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow | 5 | 0 | 1 | 22 | 1 |
Cascade MC400 | boiler | 210 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow | 5 | 0 | 1 | 23 | 1 |
Cascade MC400 | boiler | 210 | burnstarts | burner starts | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | 5 | 0 | 1 | 24 | 2 |
Cascade MC400 | boiler | 210 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin | 5 | 0 | 1 | 26 | 2 |
Cascade MC400 | boiler | 210 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin | 5 | 0 | 1 | 28 | 2 |
Cascade MC400 | boiler | 210 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin | 5 | 0 | 1 | 30 | 2 |
Cascade MC400 | boiler | 210 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | 5 | 0 | 1 | 32 | 2 |
Cascade MC400 | boiler | 210 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime | 5 | 0 | 1 | 34 | 2 |
Cascade MC400 | boiler | 210 | lastcode | last error code | string | | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | 5 | 0 | 1 | 36 | 28 |
Cascade MC400 | boiler | 210 | servicecode | service code | string | | False | sensor.boiler_service_code | sensor.boiler_servicecode | 5 | 0 | 1 | 64 | 2 |
Cascade MC400 | boiler | 210 | servicecodenumber | service code number | uint16 (>=0<=31999) | | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | 5 | 0 | 1 | 66 | 1 |
Cascade MC400 | boiler | 210 | maintenancemessage | maintenance message | string | | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | 5 | 0 | 1 | 67 | 2 |
Cascade MC400 | boiler | 210 | maintenance | maintenance scheduled | enum [off|time|date|manual] | | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | 5 | 0 | 1 | 69 | 1 |
Cascade MC400 | boiler | 210 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime | 5 | 0 | 1 | 70 | 1 |
Cascade MC400 | boiler | 210 | maintenancedate | next maintenance date | string | | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | 5 | 0 | 1 | 71 | 6 |
Cascade MC400 | boiler | 210 | emergencyops | emergency operation | boolean | | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | 5 | 0 | 1 | 77 | 1 |
Cascade MC400 | boiler | 210 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp | 5 | 0 | 1 | 78 | 1 |
Cascade MC400 | boiler | 210 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat | 5 | 0 | 1/10 | 91 | 2 |
Cascade MC400 | boiler | 210 | meter | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meter | 5 | 9 | 1/10 | 2 | 2 |
Cascade MC400 | boiler | 210 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat | 5 | 0 | 1/10 | 264 | 2 |
Cascade MC400 | boiler | 210 | gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeter | 5 | 9 | 1/10 | 69 | 2 |
Cascade MC400 | boiler | 210 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 | 5 | 0 | 1/10 | 266 | 2 |
Cascade MC400 | boiler | 210 | nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrg2 | 5 | 9 | 1/10 | 71 | 2 |
Cascade MC400 | boiler | 210 | tapactivated | turn on/off | boolean | | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | 5 | 9 | 1 | 28 | 1 |
Cascade MC400 | boiler | 210 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp | 5 | 9 | 1 | 29 | 1 |
Cascade MC400 | boiler | 210 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp | 5 | 9 | 1 | 30 | 1 |
Cascade MC400 | boiler | 210 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow | 5 | 9 | 1 | 31 | 1 |
Cascade MC400 | boiler | 210 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus | 5 | 9 | 1 | 32 | 1 |
Cascade MC400 | boiler | 210 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff | 5 | 9 | 1 | 33 | 1 |
Cascade MC400 | boiler | 210 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle | 5 | 9 | 1 | 34 | 1 |
Cascade MC400 | boiler | 210 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp | 5 | 9 | 1/10 | 35 | 1 |
Cascade MC400 | boiler | 210 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | 5 | 9 | 1 | 36 | 1 |
Cascade MC400 | boiler | 210 | comfort | comfort | enum [hot|eco|intelligent] | | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | 5 | 9 | 1 | 37 | 1 |
Cascade MC400 | boiler | 210 | comfort1 | comfort mode | enum [high comfort|eco] | | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | 5 | 9 | 1 | 38 | 1 |
Cascade MC400 | boiler | 210 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset | 5 | 9 | 1 | 39 | 1 |
Cascade MC400 | boiler | 210 | chargeoptimization | charge optimization | boolean | | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | 5 | 9 | 1 | 40 | 1 |
Cascade MC400 | boiler | 210 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower | 5 | 9 | 1 | 41 | 1 |
Cascade MC400 | boiler | 210 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp | 5 | 9 | 1 | 42 | 1 |
Cascade MC400 | boiler | 210 | circpump | circulation pump available | boolean | | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | 5 | 9 | 1 | 43 | 1 |
Cascade MC400 | boiler | 210 | chargetype | charging type | enum [chargepump|3-way valve] | | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | 5 | 9 | 1 | 44 | 1 |
Cascade MC400 | boiler | 210 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston | 5 | 9 | 1 | 45 | 1 |
Cascade MC400 | boiler | 210 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff | 5 | 9 | 1 | 46 | 1 |
Cascade MC400 | boiler | 210 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp | 5 | 9 | 1 | 47 | 1 |
Cascade MC400 | boiler | 210 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | 5 | 9 | 1 | 48 | 1 |
Cascade MC400 | boiler | 210 | circ | circulation active | boolean | | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | 5 | 9 | 1 | 49 | 1 |
Cascade MC400 | boiler | 210 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp | 5 | 9 | 1/10 | 50 | 1 |
Cascade MC400 | boiler | 210 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 | 5 | 9 | 1/10 | 51 | 1 |
Cascade MC400 | boiler | 210 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow | 5 | 9 | 1/10 | 52 | 1 |
Cascade MC400 | boiler | 210 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 | 5 | 9 | 1/10 | 53 | 1 |
Cascade MC400 | boiler | 210 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 | 5 | 9 | 1/10 | 54 | 1 |
Cascade MC400 | boiler | 210 | activated | activated | boolean | | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | 5 | 9 | 1 | 55 | 1 |
Cascade MC400 | boiler | 210 | onetime | one time charging | boolean | | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | 5 | 9 | 1 | 56 | 1 |
Cascade MC400 | boiler | 210 | disinfecting | disinfecting | boolean | | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | 5 | 9 | 1 | 57 | 1 |
Cascade MC400 | boiler | 210 | charging | charging | boolean | | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | 5 | 9 | 1 | 58 | 1 |
Cascade MC400 | boiler | 210 | recharging | recharging | boolean | | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | 5 | 9 | 1 | 59 | 1 |
Cascade MC400 | boiler | 210 | tempok | temperature ok | boolean | | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | 5 | 9 | 1 | 60 | 1 |
Cascade MC400 | boiler | 210 | active | active | boolean | | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | 5 | 9 | 1 | 61 | 1 |
Cascade MC400 | boiler | 210 | 3wayvalve | 3-way valve active | boolean | | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | 5 | 9 | 1 | 62 | 1 |
Cascade MC400 | boiler | 210 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp | 5 | 9 | 1/10 | 63 | 1 |
Cascade MC400 | boiler | 210 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp | 5 | 9 | 1/10 | 64 | 1 |
Cascade MC400 | boiler | 210 | starts | starts | uint24 (>=0<=16777213) | | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | 5 | 9 | 1 | 65 | 2 |
Cascade MC400 | boiler | 210 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm | 5 | 9 | 1 | 67 | 2 |
Cascade MC400 | boiler | 210 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower | 5 | 0 | 1 | 268 | 1 |
Cascade MC400 | boiler | 210 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal | 5 | 0 | 1/100 | 79 | 2 |
Cascade MC400 | boiler | 210 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat | 5 | 0 | 1/100 | 81 | 2 |
Cascade MC400 | boiler | 210 | nrg | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrg | 5 | 9 | 1/100 | 0 | 2 |
EasyControl Adapter | boiler | 211 | reset | reset | cmd [-|maintenance|error|history|message] | | True | sensor.boiler_reset | sensor.boiler_reset | 5 | 0 | 1 | 0 | 1 |
EasyControl Adapter | boiler | 211 | heatingoff | force heating off | boolean | | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | 5 | 0 | 1 | 1 | 1 |
EasyControl Adapter | boiler | 211 | heatingactive | heating active | boolean | | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | 5 | 0 | 1 | 2 | 1 |
EasyControl Adapter | boiler | 211 | tapwateractive | tapwater active | boolean | | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | 5 | 0 | 1 | 3 | 1 |
EasyControl Adapter | boiler | 211 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp | 5 | 0 | 1 | 4 | 1 |
EasyControl Adapter | boiler | 211 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod | 5 | 0 | 1 | 5 | 1 |
EasyControl Adapter | boiler | 211 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp | 5 | 0 | 1/10 | 6 | 1 |
EasyControl Adapter | boiler | 211 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp | 5 | 0 | 1/10 | 7 | 1 |
EasyControl Adapter | boiler | 211 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp | 5 | 0 | 1/10 | 8 | 1 |
EasyControl Adapter | boiler | 211 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp | 5 | 0 | 1/10 | 9 | 1 |
EasyControl Adapter | boiler | 211 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress | 5 | 0 | 1/10 | 10 | 1 |
EasyControl Adapter | boiler | 211 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp | 5 | 0 | 1/10 | 11 | 1 |
EasyControl Adapter | boiler | 211 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp | 5 | 0 | 1/10 | 12 | 1 |
EasyControl Adapter | boiler | 211 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp | 5 | 0 | 1/10 | 242 | 1 |
EasyControl Adapter | boiler | 211 | burngas | gas | boolean | | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | 5 | 0 | 1 | 243 | 1 |
EasyControl Adapter | boiler | 211 | burngas2 | gas stage 2 | boolean | | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | 5 | 0 | 1 | 244 | 1 |
EasyControl Adapter | boiler | 211 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr | 5 | 0 | 1/10 | 245 | 1 |
EasyControl Adapter | boiler | 211 | fanwork | fan | boolean | | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | 5 | 0 | 1 | 246 | 1 |
EasyControl Adapter | boiler | 211 | ignwork | ignition | boolean | | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | 5 | 0 | 1 | 247 | 1 |
EasyControl Adapter | boiler | 211 | oilpreheat | oil preheating | boolean | | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | 5 | 0 | 1 | 248 | 1 |
EasyControl Adapter | boiler | 211 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower | 5 | 0 | 1 | 249 | 1 |
EasyControl Adapter | boiler | 211 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower | 5 | 0 | 1 | 250 | 1 |
EasyControl Adapter | boiler | 211 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod | 5 | 0 | 1 | 251 | 1 |
EasyControl Adapter | boiler | 211 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow | 5 | 0 | 1 | 252 | 1 |
EasyControl Adapter | boiler | 211 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock | 5 | 0 | 1/10 | 253 | 1 |
EasyControl Adapter | boiler | 211 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston | 5 | 0 | 1 | 254 | 1 |
EasyControl Adapter | boiler | 211 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff | 5 | 0 | 1 | 255 | 1 |
EasyControl Adapter | boiler | 211 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston | 5 | 0 | 1 | 256 | 1 |
EasyControl Adapter | boiler | 211 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff | 5 | 0 | 1 | 257 | 1 |
EasyControl Adapter | boiler | 211 | curveon | heatingcurve on | boolean | | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | 5 | 0 | 1 | 258 | 1 |
EasyControl Adapter | boiler | 211 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase | 5 | 0 | 1 | 259 | 1 |
EasyControl Adapter | boiler | 211 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend | 5 | 0 | 1 | 260 | 1 |
EasyControl Adapter | boiler | 211 | summertemp | summer temperature | uint8 (>=0<=45) | C | True | number.boiler_summer_temperature | number.boiler_summertemp | 5 | 0 | 1 | 261 | 1 |
EasyControl Adapter | boiler | 211 | nofrostmode | nofrost mode | boolean | | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | 5 | 0 | 1 | 262 | 1 |
EasyControl Adapter | boiler | 211 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp | 5 | 0 | 1 | 263 | 1 |
EasyControl Adapter | boiler | 211 | heatingactivated | heating activated | boolean | | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | 5 | 0 | 1 | 13 | 1 |
EasyControl Adapter | boiler | 211 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp | 5 | 0 | 1 | 14 | 1 |
EasyControl Adapter | boiler | 211 | heatingpump | heating pump | boolean | | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | 5 | 0 | 1 | 15 | 1 |
EasyControl Adapter | boiler | 211 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax | 5 | 0 | 1 | 16 | 1 |
EasyControl Adapter | boiler | 211 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin | 5 | 0 | 1 | 17 | 1 |
EasyControl Adapter | boiler | 211 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | 5 | 0 | 1 | 18 | 1 |
EasyControl Adapter | boiler | 211 | pumpcharacter | boiler pump characteristic | enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] | | True | select.boiler_boiler_pump_characteristic | select.boiler_pumpcharacter | 5 | 0 | 1 | 19 | 1 |
EasyControl Adapter | boiler | 211 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay | 5 | 0 | 1 | 20 | 1 |
EasyControl Adapter | boiler | 211 | pumpontemp | pump logic temperature | uint8 (>=0<=60) | C | True | number.boiler_pump_logic_temperature | number.boiler_pumpontemp | 5 | 0 | 1 | 21 | 1 |
EasyControl Adapter | boiler | 211 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow | 5 | 0 | 1 | 22 | 1 |
EasyControl Adapter | boiler | 211 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow | 5 | 0 | 1 | 23 | 1 |
EasyControl Adapter | boiler | 211 | burnstarts | burner starts | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | 5 | 0 | 1 | 24 | 2 |
EasyControl Adapter | boiler | 211 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin | 5 | 0 | 1 | 26 | 2 |
EasyControl Adapter | boiler | 211 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin | 5 | 0 | 1 | 28 | 2 |
EasyControl Adapter | boiler | 211 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin | 5 | 0 | 1 | 30 | 2 |
EasyControl Adapter | boiler | 211 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | 5 | 0 | 1 | 32 | 2 |
EasyControl Adapter | boiler | 211 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime | 5 | 0 | 1 | 34 | 2 |
EasyControl Adapter | boiler | 211 | lastcode | last error code | string | | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | 5 | 0 | 1 | 36 | 28 |
EasyControl Adapter | boiler | 211 | servicecode | service code | string | | False | sensor.boiler_service_code | sensor.boiler_servicecode | 5 | 0 | 1 | 64 | 2 |
EasyControl Adapter | boiler | 211 | servicecodenumber | service code number | uint16 (>=0<=31999) | | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | 5 | 0 | 1 | 66 | 1 |
EasyControl Adapter | boiler | 211 | maintenancemessage | maintenance message | string | | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | 5 | 0 | 1 | 67 | 2 |
EasyControl Adapter | boiler | 211 | maintenance | maintenance scheduled | enum [off|time|date|manual] | | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | 5 | 0 | 1 | 69 | 1 |
EasyControl Adapter | boiler | 211 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime | 5 | 0 | 1 | 70 | 1 |
EasyControl Adapter | boiler | 211 | maintenancedate | next maintenance date | string | | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | 5 | 0 | 1 | 71 | 6 |
EasyControl Adapter | boiler | 211 | emergencyops | emergency operation | boolean | | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | 5 | 0 | 1 | 77 | 1 |
EasyControl Adapter | boiler | 211 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp | 5 | 0 | 1 | 78 | 1 |
EasyControl Adapter | boiler | 211 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat | 5 | 0 | 1/10 | 91 | 2 |
EasyControl Adapter | boiler | 211 | meter | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meter | 5 | 9 | 1/10 | 2 | 2 |
EasyControl Adapter | boiler | 211 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat | 5 | 0 | 1/10 | 264 | 2 |
EasyControl Adapter | boiler | 211 | gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeter | 5 | 9 | 1/10 | 69 | 2 |
EasyControl Adapter | boiler | 211 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 | 5 | 0 | 1/10 | 266 | 2 |
EasyControl Adapter | boiler | 211 | nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrg2 | 5 | 9 | 1/10 | 71 | 2 |
EasyControl Adapter | boiler | 211 | tapactivated | turn on/off | boolean | | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | 5 | 9 | 1 | 28 | 1 |
EasyControl Adapter | boiler | 211 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp | 5 | 9 | 1 | 29 | 1 |
EasyControl Adapter | boiler | 211 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp | 5 | 9 | 1 | 30 | 1 |
EasyControl Adapter | boiler | 211 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow | 5 | 9 | 1 | 31 | 1 |
EasyControl Adapter | boiler | 211 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus | 5 | 9 | 1 | 32 | 1 |
EasyControl Adapter | boiler | 211 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff | 5 | 9 | 1 | 33 | 1 |
EasyControl Adapter | boiler | 211 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle | 5 | 9 | 1 | 34 | 1 |
EasyControl Adapter | boiler | 211 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp | 5 | 9 | 1/10 | 35 | 1 |
EasyControl Adapter | boiler | 211 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | 5 | 9 | 1 | 36 | 1 |
EasyControl Adapter | boiler | 211 | comfort | comfort | enum [hot|eco|intelligent] | | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | 5 | 9 | 1 | 37 | 1 |
EasyControl Adapter | boiler | 211 | comfort1 | comfort mode | enum [high comfort|eco] | | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | 5 | 9 | 1 | 38 | 1 |
EasyControl Adapter | boiler | 211 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset | 5 | 9 | 1 | 39 | 1 |
EasyControl Adapter | boiler | 211 | chargeoptimization | charge optimization | boolean | | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | 5 | 9 | 1 | 40 | 1 |
EasyControl Adapter | boiler | 211 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower | 5 | 9 | 1 | 41 | 1 |
EasyControl Adapter | boiler | 211 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp | 5 | 9 | 1 | 42 | 1 |
EasyControl Adapter | boiler | 211 | circpump | circulation pump available | boolean | | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | 5 | 9 | 1 | 43 | 1 |
EasyControl Adapter | boiler | 211 | chargetype | charging type | enum [chargepump|3-way valve] | | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | 5 | 9 | 1 | 44 | 1 |
EasyControl Adapter | boiler | 211 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston | 5 | 9 | 1 | 45 | 1 |
EasyControl Adapter | boiler | 211 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff | 5 | 9 | 1 | 46 | 1 |
EasyControl Adapter | boiler | 211 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp | 5 | 9 | 1 | 47 | 1 |
EasyControl Adapter | boiler | 211 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | 5 | 9 | 1 | 48 | 1 |
EasyControl Adapter | boiler | 211 | circ | circulation active | boolean | | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | 5 | 9 | 1 | 49 | 1 |
EasyControl Adapter | boiler | 211 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp | 5 | 9 | 1/10 | 50 | 1 |
EasyControl Adapter | boiler | 211 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 | 5 | 9 | 1/10 | 51 | 1 |
EasyControl Adapter | boiler | 211 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow | 5 | 9 | 1/10 | 52 | 1 |
EasyControl Adapter | boiler | 211 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 | 5 | 9 | 1/10 | 53 | 1 |
EasyControl Adapter | boiler | 211 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 | 5 | 9 | 1/10 | 54 | 1 |
EasyControl Adapter | boiler | 211 | activated | activated | boolean | | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | 5 | 9 | 1 | 55 | 1 |
EasyControl Adapter | boiler | 211 | onetime | one time charging | boolean | | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | 5 | 9 | 1 | 56 | 1 |
EasyControl Adapter | boiler | 211 | disinfecting | disinfecting | boolean | | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | 5 | 9 | 1 | 57 | 1 |
EasyControl Adapter | boiler | 211 | charging | charging | boolean | | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | 5 | 9 | 1 | 58 | 1 |
EasyControl Adapter | boiler | 211 | recharging | recharging | boolean | | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | 5 | 9 | 1 | 59 | 1 |
EasyControl Adapter | boiler | 211 | tempok | temperature ok | boolean | | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | 5 | 9 | 1 | 60 | 1 |
EasyControl Adapter | boiler | 211 | active | active | boolean | | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | 5 | 9 | 1 | 61 | 1 |
EasyControl Adapter | boiler | 211 | 3wayvalve | 3-way valve active | boolean | | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | 5 | 9 | 1 | 62 | 1 |
EasyControl Adapter | boiler | 211 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp | 5 | 9 | 1/10 | 63 | 1 |
EasyControl Adapter | boiler | 211 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp | 5 | 9 | 1/10 | 64 | 1 |
EasyControl Adapter | boiler | 211 | starts | starts | uint24 (>=0<=16777213) | | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | 5 | 9 | 1 | 65 | 2 |
EasyControl Adapter | boiler | 211 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm | 5 | 9 | 1 | 67 | 2 |
EasyControl Adapter | boiler | 211 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower | 5 | 0 | 1 | 268 | 1 |
EasyControl Adapter | boiler | 211 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal | 5 | 0 | 1/100 | 79 | 2 |
EasyControl Adapter | boiler | 211 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat | 5 | 0 | 1/100 | 81 | 2 |
EasyControl Adapter | boiler | 211 | nrg | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrg | 5 | 9 | 1/100 | 0 | 2 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | netflowtemp | heat network flow temp | uint16 (>=0<=3199) | C | False | sensor.boiler_heat_network_flow_temp | sensor.boiler_netflowtemp | 5 | 0 | 1/10 | 269 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | heatvalve | heating valve | uint8 (>=0<=100) | % | False | sensor.boiler_heating_valve | sensor.boiler_heatvalve | 5 | 0 | 1 | 270 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | dhwvalve | valve | uint8 (>=0<=100) | % | False | sensor.boiler_dhw_valve | sensor.boiler_dhw_dhwvalve | 5 | 9 | 1 | 73 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow | 5 | 9 | 1/10 | 52 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | keepwarmtemp | keep warm temperature | uint8 (>=0<=254) | C | True | number.boiler_keep_warm_temperature | number.boiler_keepwarmtemp | 5 | 0 | 1 | 271 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | setreturntemp | set temp return | uint8 (>=0<=254) | C | True | number.boiler_set_temp_return | number.boiler_setreturntemp | 5 | 0 | 1 | 272 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | heating | heating | boolean | | False | binary_sensor.boiler_heating | binary_sensor.boiler_heating | 5 | 0 | 1 | 273 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | reset | reset | cmd [-|maintenance|error|history|message] | | True | sensor.boiler_reset | sensor.boiler_reset | 5 | 0 | 1 | 0 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | heatingoff | force heating off | boolean | | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | 5 | 0 | 1 | 1 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | heatingactive | heating active | boolean | | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | 5 | 0 | 1 | 2 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | tapwateractive | tapwater active | boolean | | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | 5 | 0 | 1 | 3 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp | 5 | 0 | 1 | 4 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod | 5 | 0 | 1 | 5 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp | 5 | 0 | 1/10 | 6 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp | 5 | 0 | 1/10 | 7 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp | 5 | 0 | 1/10 | 8 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp | 5 | 0 | 1/10 | 9 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress | 5 | 0 | 1/10 | 10 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp | 5 | 0 | 1/10 | 11 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp | 5 | 0 | 1/10 | 12 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | heatingactivated | heating activated | boolean | | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | 5 | 0 | 1 | 13 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp | 5 | 0 | 1 | 14 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | heatingpump | heating pump | boolean | | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | 5 | 0 | 1 | 15 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax | 5 | 0 | 1 | 16 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin | 5 | 0 | 1 | 17 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | 5 | 0 | 1 | 18 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | pumpcharacter | boiler pump characteristic | enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] | | True | select.boiler_boiler_pump_characteristic | select.boiler_pumpcharacter | 5 | 0 | 1 | 19 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay | 5 | 0 | 1 | 20 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | pumpontemp | pump logic temperature | uint8 (>=0<=60) | C | True | number.boiler_pump_logic_temperature | number.boiler_pumpontemp | 5 | 0 | 1 | 21 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow | 5 | 0 | 1 | 22 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow | 5 | 0 | 1 | 23 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | burnstarts | burner starts | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | 5 | 0 | 1 | 24 | 2 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin | 5 | 0 | 1 | 26 | 2 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin | 5 | 0 | 1 | 28 | 2 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin | 5 | 0 | 1 | 30 | 2 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | 5 | 0 | 1 | 32 | 2 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime | 5 | 0 | 1 | 34 | 2 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | lastcode | last error code | string | | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | 5 | 0 | 1 | 36 | 28 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | servicecode | service code | string | | False | sensor.boiler_service_code | sensor.boiler_servicecode | 5 | 0 | 1 | 64 | 2 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | servicecodenumber | service code number | uint16 (>=0<=31999) | | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | 5 | 0 | 1 | 66 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | maintenancemessage | maintenance message | string | | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | 5 | 0 | 1 | 67 | 2 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | maintenance | maintenance scheduled | enum [off|time|date|manual] | | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | 5 | 0 | 1 | 69 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime | 5 | 0 | 1 | 70 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | maintenancedate | next maintenance date | string | | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | 5 | 0 | 1 | 71 | 6 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | emergencyops | emergency operation | boolean | | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | 5 | 0 | 1 | 77 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp | 5 | 0 | 1 | 78 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat | 5 | 0 | 1/10 | 91 | 2 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | meter | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meter | 5 | 9 | 1/10 | 2 | 2 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat | 5 | 0 | 1/10 | 264 | 2 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeter | 5 | 9 | 1/10 | 69 | 2 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 | 5 | 0 | 1/10 | 266 | 2 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrg2 | 5 | 9 | 1/10 | 71 | 2 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | tapactivated | turn on/off | boolean | | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | 5 | 9 | 1 | 28 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp | 5 | 9 | 1 | 29 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp | 5 | 9 | 1 | 30 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow | 5 | 9 | 1 | 31 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus | 5 | 9 | 1 | 32 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff | 5 | 9 | 1 | 33 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle | 5 | 9 | 1 | 34 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp | 5 | 9 | 1/10 | 35 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | 5 | 9 | 1 | 36 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | comfort | comfort | enum [hot|eco|intelligent] | | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | 5 | 9 | 1 | 37 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | comfort1 | comfort mode | enum [high comfort|eco] | | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | 5 | 9 | 1 | 38 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset | 5 | 9 | 1 | 39 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | chargeoptimization | charge optimization | boolean | | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | 5 | 9 | 1 | 40 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower | 5 | 9 | 1 | 41 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp | 5 | 9 | 1 | 42 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | circpump | circulation pump available | boolean | | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | 5 | 9 | 1 | 43 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | chargetype | charging type | enum [chargepump|3-way valve] | | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | 5 | 9 | 1 | 44 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston | 5 | 9 | 1 | 45 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff | 5 | 9 | 1 | 46 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp | 5 | 9 | 1 | 47 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | 5 | 9 | 1 | 48 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | circ | circulation active | boolean | | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | 5 | 9 | 1 | 49 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp | 5 | 9 | 1/10 | 50 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 | 5 | 9 | 1/10 | 51 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow | 5 | 9 | 1/10 | 52 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 | 5 | 9 | 1/10 | 53 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 | 5 | 9 | 1/10 | 54 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | activated | activated | boolean | | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | 5 | 9 | 1 | 55 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | onetime | one time charging | boolean | | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | 5 | 9 | 1 | 56 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | disinfecting | disinfecting | boolean | | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | 5 | 9 | 1 | 57 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | charging | charging | boolean | | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | 5 | 9 | 1 | 58 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | recharging | recharging | boolean | | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | 5 | 9 | 1 | 59 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | tempok | temperature ok | boolean | | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | 5 | 9 | 1 | 60 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | active | active | boolean | | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | 5 | 9 | 1 | 61 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | 3wayvalve | 3-way valve active | boolean | | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | 5 | 9 | 1 | 62 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp | 5 | 9 | 1/10 | 63 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp | 5 | 9 | 1/10 | 64 | 1 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | starts | starts | uint24 (>=0<=16777213) | | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | 5 | 9 | 1 | 65 | 2 |
Greenstar HIU, Logamax kompakt WS170 | boiler | 219 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm | 5 | 9 | 1 | 67 | 2 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | reset | reset | cmd [-|maintenance|error|history|message] | | True | sensor.boiler_reset | sensor.boiler_reset | 5 | 0 | 1 | 0 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | heatingoff | force heating off | boolean | | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | 5 | 0 | 1 | 1 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | heatingactive | heating active | boolean | | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | 5 | 0 | 1 | 2 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | tapwateractive | tapwater active | boolean | | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | 5 | 0 | 1 | 3 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp | 5 | 0 | 1 | 4 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod | 5 | 0 | 1 | 5 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp | 5 | 0 | 1/10 | 6 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp | 5 | 0 | 1/10 | 7 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp | 5 | 0 | 1/10 | 8 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp | 5 | 0 | 1/10 | 9 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress | 5 | 0 | 1/10 | 10 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp | 5 | 0 | 1/10 | 11 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp | 5 | 0 | 1/10 | 12 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp | 5 | 0 | 1/10 | 242 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | burngas | gas | boolean | | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | 5 | 0 | 1 | 243 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | burngas2 | gas stage 2 | boolean | | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | 5 | 0 | 1 | 244 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr | 5 | 0 | 1/10 | 245 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | fanwork | fan | boolean | | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | 5 | 0 | 1 | 246 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | ignwork | ignition | boolean | | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | 5 | 0 | 1 | 247 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | oilpreheat | oil preheating | boolean | | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | 5 | 0 | 1 | 248 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower | 5 | 0 | 1 | 249 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower | 5 | 0 | 1 | 250 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod | 5 | 0 | 1 | 251 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow | 5 | 0 | 1 | 252 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock | 5 | 0 | 1/10 | 253 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston | 5 | 0 | 1 | 254 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff | 5 | 0 | 1 | 255 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston | 5 | 0 | 1 | 256 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff | 5 | 0 | 1 | 257 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | curveon | heatingcurve on | boolean | | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | 5 | 0 | 1 | 258 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase | 5 | 0 | 1 | 259 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend | 5 | 0 | 1 | 260 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | summertemp | summer temperature | uint8 (>=0<=45) | C | True | number.boiler_summer_temperature | number.boiler_summertemp | 5 | 0 | 1 | 261 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | nofrostmode | nofrost mode | boolean | | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | 5 | 0 | 1 | 262 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp | 5 | 0 | 1 | 263 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | heatingactivated | heating activated | boolean | | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | 5 | 0 | 1 | 13 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp | 5 | 0 | 1 | 14 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | heatingpump | heating pump | boolean | | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | 5 | 0 | 1 | 15 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax | 5 | 0 | 1 | 16 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin | 5 | 0 | 1 | 17 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | 5 | 0 | 1 | 18 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | pumpcharacter | boiler pump characteristic | enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] | | True | select.boiler_boiler_pump_characteristic | select.boiler_pumpcharacter | 5 | 0 | 1 | 19 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay | 5 | 0 | 1 | 20 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | pumpontemp | pump logic temperature | uint8 (>=0<=60) | C | True | number.boiler_pump_logic_temperature | number.boiler_pumpontemp | 5 | 0 | 1 | 21 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow | 5 | 0 | 1 | 22 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow | 5 | 0 | 1 | 23 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | burnstarts | burner starts | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | 5 | 0 | 1 | 24 | 2 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin | 5 | 0 | 1 | 26 | 2 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin | 5 | 0 | 1 | 28 | 2 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin | 5 | 0 | 1 | 30 | 2 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | 5 | 0 | 1 | 32 | 2 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime | 5 | 0 | 1 | 34 | 2 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | lastcode | last error code | string | | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | 5 | 0 | 1 | 36 | 28 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | servicecode | service code | string | | False | sensor.boiler_service_code | sensor.boiler_servicecode | 5 | 0 | 1 | 64 | 2 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | servicecodenumber | service code number | uint16 (>=0<=31999) | | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | 5 | 0 | 1 | 66 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | maintenancemessage | maintenance message | string | | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | 5 | 0 | 1 | 67 | 2 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | maintenance | maintenance scheduled | enum [off|time|date|manual] | | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | 5 | 0 | 1 | 69 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime | 5 | 0 | 1 | 70 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | maintenancedate | next maintenance date | string | | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | 5 | 0 | 1 | 71 | 6 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | emergencyops | emergency operation | boolean | | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | 5 | 0 | 1 | 77 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp | 5 | 0 | 1 | 78 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat | 5 | 0 | 1/10 | 91 | 2 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | meter | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meter | 5 | 9 | 1/10 | 2 | 2 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat | 5 | 0 | 1/10 | 264 | 2 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeter | 5 | 9 | 1/10 | 69 | 2 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 | 5 | 0 | 1/10 | 266 | 2 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrg2 | 5 | 9 | 1/10 | 71 | 2 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | tapactivated | turn on/off | boolean | | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | 5 | 9 | 1 | 28 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp | 5 | 9 | 1 | 29 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp | 5 | 9 | 1 | 30 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow | 5 | 9 | 1 | 31 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus | 5 | 9 | 1 | 32 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff | 5 | 9 | 1 | 33 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle | 5 | 9 | 1 | 34 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp | 5 | 9 | 1/10 | 35 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | 5 | 9 | 1 | 36 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | comfort | comfort | enum [hot|eco|intelligent] | | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | 5 | 9 | 1 | 37 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | comfort1 | comfort mode | enum [high comfort|eco] | | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | 5 | 9 | 1 | 38 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset | 5 | 9 | 1 | 39 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | chargeoptimization | charge optimization | boolean | | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | 5 | 9 | 1 | 40 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower | 5 | 9 | 1 | 41 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp | 5 | 9 | 1 | 42 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | circpump | circulation pump available | boolean | | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | 5 | 9 | 1 | 43 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | chargetype | charging type | enum [chargepump|3-way valve] | | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | 5 | 9 | 1 | 44 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston | 5 | 9 | 1 | 45 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff | 5 | 9 | 1 | 46 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp | 5 | 9 | 1 | 47 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | 5 | 9 | 1 | 48 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | circ | circulation active | boolean | | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | 5 | 9 | 1 | 49 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp | 5 | 9 | 1/10 | 50 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 | 5 | 9 | 1/10 | 51 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow | 5 | 9 | 1/10 | 52 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 | 5 | 9 | 1/10 | 53 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 | 5 | 9 | 1/10 | 54 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | activated | activated | boolean | | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | 5 | 9 | 1 | 55 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | onetime | one time charging | boolean | | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | 5 | 9 | 1 | 56 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | disinfecting | disinfecting | boolean | | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | 5 | 9 | 1 | 57 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | charging | charging | boolean | | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | 5 | 9 | 1 | 58 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | recharging | recharging | boolean | | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | 5 | 9 | 1 | 59 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | tempok | temperature ok | boolean | | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | 5 | 9 | 1 | 60 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | active | active | boolean | | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | 5 | 9 | 1 | 61 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | 3wayvalve | 3-way valve active | boolean | | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | 5 | 9 | 1 | 62 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp | 5 | 9 | 1/10 | 63 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp | 5 | 9 | 1/10 | 64 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | starts | starts | uint24 (>=0<=16777213) | | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | 5 | 9 | 1 | 65 | 2 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm | 5 | 9 | 1 | 67 | 2 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower | 5 | 0 | 1 | 268 | 1 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal | 5 | 0 | 1/100 | 79 | 2 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat | 5 | 0 | 1/100 | 81 | 2 |
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W | boiler | 234 | nrg | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrg | 5 | 9 | 1/100 | 0 | 2 |
Logamatic TC100, Moduline Easy | thermostat | 202 | errorcode | error code | string | | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | 6 | 0 | 1 | 0 | 8 |
Logamatic TC100, Moduline Easy | thermostat | 202 | lastcode | last error code | string | | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | 6 | 0 | 1 | 8 | 25 |
Logamatic TC100, Moduline Easy | thermostat | 202 | datetime | date/time | string | | False | sensor.thermostat_date/time | sensor.thermostat_datetime | 6 | 0 | 1 | 33 | 13 |
Logamatic TC100, Moduline Easy | thermostat | 202 | seltemp | selected room temperature | int16 (>=-319<=319) | C | False | sensor.thermostat_hc1_selected_room_temperature | sensor.thermostat_hc1_seltemp | 6 | 1 | 1/100 | 0 | 1 |
Logamatic TC100, Moduline Easy | thermostat | 202 | currtemp | current room temperature | int16 (>=-319<=319) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp | 6 | 1 | 1/100 | 1 | 1 |
Logamatic TC100, Moduline Easy | thermostat | 202 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | 6 | 1 | 1 | 2 | 1 |
EasyControl, CT200 | thermostat | 203 | errorcode | error code | string | | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | 6 | 0 | 1 | 0 | 8 |
EasyControl, CT200 | thermostat | 203 | lastcode | last error code | string | | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | 6 | 0 | 1 | 8 | 25 |
EasyControl, CT200 | thermostat | 203 | datetime | date/time | string | | False | sensor.thermostat_date/time | sensor.thermostat_datetime | 6 | 0 | 1 | 33 | 13 |
EasyControl, CT200 | thermostat | 203 | seltemp | selected room temperature | int16 (>=-319<=319) | C | False | sensor.thermostat_hc1_selected_room_temperature | sensor.thermostat_hc1_seltemp | 6 | 1 | 1/100 | 0 | 1 |
EasyControl, CT200 | thermostat | 203 | currtemp | current room temperature | int16 (>=-319<=319) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp | 6 | 1 | 1/100 | 1 | 1 |
EasyControl, CT200 | thermostat | 203 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | 6 | 1 | 1 | 2 | 1 |
UI800, BC400 | thermostat | 4 | errorcode | error code | string | | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | 6 | 0 | 1 | 0 | 8 |
UI800, BC400 | thermostat | 4 | lastcode | last error code | string | | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | 6 | 0 | 1 | 8 | 25 |
UI800, BC400 | thermostat | 4 | datetime | date/time | string | | True | sensor.thermostat_date/time | sensor.thermostat_datetime | 6 | 0 | 1 | 33 | 13 |
UI800, BC400 | thermostat | 4 | intoffset | internal temperature offset | int8 (>=-12<=12) | C | True | number.thermostat_internal_temperature_offset | number.thermostat_intoffset | 6 | 0 | 1/10 | 46 | 1 |
UI800, BC400 | thermostat | 4 | floordry | floor drying | enum [off|start|heat|hold|cool|end] | | False | sensor.thermostat_floor_drying | sensor.thermostat_floordry | 6 | 0 | 1 | 47 | 1 |
UI800, BC400 | thermostat | 4 | dampedoutdoortemp | damped outdoor temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_damped_outdoor_temperature | sensor.thermostat_dampedoutdoortemp | 6 | 0 | 1/10 | 48 | 1 |
UI800, BC400 | thermostat | 4 | floordrytemp | floor drying temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_floor_drying_temperature | sensor.thermostat_floordrytemp | 6 | 0 | 1 | 49 | 1 |
UI800, BC400 | thermostat | 4 | building | building type | enum [light|medium|heavy] | | True | select.thermostat_building_type | select.thermostat_building | 6 | 0 | 1 | 50 | 1 |
UI800, BC400 | thermostat | 4 | minexttemp | minimal external temperature | int8 (>=-126<=126) | C | True | number.thermostat_minimal_external_temperature | number.thermostat_minexttemp | 6 | 0 | 1 | 51 | 1 |
UI800, BC400 | thermostat | 4 | damping | damping outdoor temperature | boolean | | True | switch.thermostat_damping_outdoor_temperature | switch.thermostat_damping | 6 | 0 | 1 | 52 | 1 |
UI800, BC400 | thermostat | 4 | hybridstrategy | hybrid control strategy | enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] | | True | select.thermostat_hybrid_control_strategy | select.thermostat_hybridstrategy | 6 | 0 | 1 | 53 | 1 |
UI800, BC400 | thermostat | 4 | switchovertemp | outside switchover temperature | int8 (>=-20<=20) | C | True | number.thermostat_outside_switchover_temperature | number.thermostat_switchovertemp | 6 | 0 | 1 | 54 | 1 |
UI800, BC400 | thermostat | 4 | energycostratio | energy cost ratio | uint8 (>=0<=20) | | True | number.thermostat_energy_cost_ratio | number.thermostat_energycostratio | 6 | 0 | 1/10 | 55 | 1 |
UI800, BC400 | thermostat | 4 | fossilefactor | fossile energy factor | uint8 (>=0<=5) | | True | number.thermostat_fossile_energy_factor | number.thermostat_fossilefactor | 6 | 0 | 1/10 | 56 | 1 |
UI800, BC400 | thermostat | 4 | electricfactor | electric energy factor | uint8 (>=0<=5) | | True | number.thermostat_electric_energy_factor | number.thermostat_electricfactor | 6 | 0 | 1/10 | 57 | 1 |
UI800, BC400 | thermostat | 4 | delayboiler | delay boiler support | uint8 (>=5<=120) | minutes | True | number.thermostat_delay_boiler_support | number.thermostat_delayboiler | 6 | 0 | 1 | 58 | 1 |
UI800, BC400 | thermostat | 4 | tempdiffboiler | temp diff boiler support | uint8 (>=1<=99) | C | True | number.thermostat_temp_diff_boiler_support | number.thermostat_tempdiffboiler | 6 | 0 | 1 | 59 | 1 |
UI800, BC400 | thermostat | 4 | pvenabledhw | enable raise dhw | boolean | | True | switch.thermostat_enable_raise_dhw | switch.thermostat_pvenabledhw | 6 | 0 | 1 | 60 | 1 |
UI800, BC400 | thermostat | 4 | pvraiseheat | raise heating with PV | int8 (>=0<=5) | K | True | number.thermostat_raise_heating_with_PV | number.thermostat_pvraiseheat | 6 | 0 | 1 | 61 | 1 |
UI800, BC400 | thermostat | 4 | pvlowercool | lower cooling with PV | int8 (>=-5<=0) | K | True | number.thermostat_lower_cooling_with_PV | number.thermostat_pvlowercool | 6 | 0 | 1 | 62 | 1 |
UI800, BC400 | thermostat | 4 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp | 6 | 1 | 1/2 | 0 | 1 |
UI800, BC400 | thermostat | 4 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp | 6 | 1 | 1/10 | 1 | 1 |
UI800, BC400 | thermostat | 4 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | 6 | 1 | 1 | 2 | 1 |
UI800, BC400 | thermostat | 4 | mode | operating mode | enum [off|manual|auto] | | True | select.thermostat_hc1_operating_mode | select.thermostat_hc1_mode | 6 | 1 | 1 | 3 | 1 |
UI800, BC400 | thermostat | 4 | modetype | mode type | enum [eco|comfort] | | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | 6 | 1 | 1 | 4 | 1 |
UI800, BC400 | thermostat | 4 | ecotemp | eco temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_eco_temperature | number.thermostat_hc1_ecotemp | 6 | 1 | 1/2 | 5 | 1 |
UI800, BC400 | thermostat | 4 | manualtemp | manual temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_manual_temperature | number.thermostat_hc1_manualtemp | 6 | 1 | 1/2 | 6 | 1 |
UI800, BC400 | thermostat | 4 | comforttemp | comfort temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_comfort_temperature | number.thermostat_hc1_comforttemp | 6 | 1 | 1/2 | 7 | 1 |
UI800, BC400 | thermostat | 4 | summertemp | summer temperature | uint8 (>=10<=30) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp | 6 | 1 | 1 | 8 | 1 |
UI800, BC400 | thermostat | 4 | designtemp | design temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp | 6 | 1 | 1 | 9 | 1 |
UI800, BC400 | thermostat | 4 | offsettemp | offset temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_offset_temperature | number.thermostat_hc1_offsettemp | 6 | 1 | 1 | 10 | 1 |
UI800, BC400 | thermostat | 4 | minflowtemp | min flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp | 6 | 1 | 1 | 11 | 1 |
UI800, BC400 | thermostat | 4 | maxflowtemp | max flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp | 6 | 1 | 1 | 12 | 1 |
UI800, BC400 | thermostat | 4 | roominfluence | room influence | uint8 (>=0<=254) | C | True | number.thermostat_hc1_room_influence | number.thermostat_hc1_roominfluence | 6 | 1 | 1 | 13 | 1 |
UI800, BC400 | thermostat | 4 | roominflfactor | room influence factor | uint8 (>=0<=25) | | True | number.thermostat_hc1_room_influence_factor | number.thermostat_hc1_roominflfactor | 6 | 1 | 1/10 | 14 | 1 |
UI800, BC400 | thermostat | 4 | curroominfl | current room influence | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_influence | sensor.thermostat_hc1_curroominfl | 6 | 1 | 1/10 | 15 | 1 |
UI800, BC400 | thermostat | 4 | nofrostmode | nofrost mode | enum [room|outdoor|room outdoor] | | True | select.thermostat_hc1_nofrost_mode | select.thermostat_hc1_nofrostmode | 6 | 1 | 1 | 16 | 1 |
UI800, BC400 | thermostat | 4 | nofrosttemp | nofrost temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp | 6 | 1 | 1 | 17 | 1 |
UI800, BC400 | thermostat | 4 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp | 6 | 1 | 1 | 18 | 1 |
UI800, BC400 | thermostat | 4 | heatingtype | heating type | enum [off|radiator|convector|floor] | | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | 6 | 1 | 1 | 19 | 1 |
UI800, BC400 | thermostat | 4 | summersetmode | set summer mode | enum [summer|auto|winter] | | True | select.thermostat_hc1_set_summer_mode | select.thermostat_hc1_summersetmode | 6 | 1 | 1 | 20 | 1 |
UI800, BC400 | thermostat | 4 | hpoperatingmode | heatpump operating mode | enum [off|auto|heating|cooling] | | True | select.thermostat_hc1_heatpump_operating_mode | select.thermostat_hc1_hpoperatingmode | 6 | 1 | 1 | 21 | 1 |
UI800, BC400 | thermostat | 4 | summermode | summer mode | enum [winter|summer] | | False | sensor.thermostat_hc1_summer_mode | sensor.thermostat_hc1_summermode | 6 | 1 | 1 | 22 | 1 |
UI800, BC400 | thermostat | 4 | hpoperatingstate | heatpump operating state | enum [heating|off|cooling] | | False | sensor.thermostat_hc1_heatpump_operating_state | sensor.thermostat_hc1_hpoperatingstate | 6 | 1 | 1 | 23 | 1 |
UI800, BC400 | thermostat | 4 | controlmode | control mode | enum [weather compensated|outside basepoint|n/a|room|power|constant] | | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | 6 | 1 | 1 | 24 | 1 |
UI800, BC400 | thermostat | 4 | program | program | enum [prog 1|prog 2] | | True | select.thermostat_hc1_program | select.thermostat_hc1_program | 6 | 1 | 1 | 25 | 1 |
UI800, BC400 | thermostat | 4 | tempautotemp | temporary set temperature automode | int8 (>=-1<=30) | C | True | number.thermostat_hc1_temporary_set_temperature_automode | number.thermostat_hc1_tempautotemp | 6 | 1 | 1/2 | 26 | 1 |
UI800, BC400 | thermostat | 4 | remoteseltemp | temporary set temperature from remote | int8 (>=-1<=30) | C | True | number.thermostat_hc1_temporary_set_temperature_from_remote | number.thermostat_hc1_remoteseltemp | 6 | 1 | 1/2 | 27 | 1 |
UI800, BC400 | thermostat | 4 | fastheatup | fast heatup | uint8 (>=0<=100) | % | True | number.thermostat_hc1_fast_heatup | number.thermostat_hc1_fastheatup | 6 | 1 | 1 | 28 | 1 |
UI800, BC400 | thermostat | 4 | switchonoptimization | switch-on optimization | boolean | | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | 6 | 1 | 1 | 29 | 1 |
UI800, BC400 | thermostat | 4 | reducemode | reduce mode | enum [outdoor|room|reduce] | | True | select.thermostat_hc1_reduce_mode | select.thermostat_hc1_reducemode | 6 | 1 | 1 | 30 | 1 |
UI800, BC400 | thermostat | 4 | noreducetemp | no reduce below temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_no_reduce_below_temperature | number.thermostat_hc1_noreducetemp | 6 | 1 | 1 | 31 | 1 |
UI800, BC400 | thermostat | 4 | reducetemp | off/reduce switch temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_off/reduce_switch_temperature | number.thermostat_hc1_reducetemp | 6 | 1 | 1 | 32 | 1 |
UI800, BC400 | thermostat | 4 | dhwprio | dhw priority | boolean | | True | switch.thermostat_hc1_dhw_priority | switch.thermostat_hc1_dhwprio | 6 | 1 | 1 | 33 | 1 |
UI800, BC400 | thermostat | 4 | hpcooling | hp cooling | boolean | | True | switch.thermostat_hc1_hp_cooling | switch.thermostat_hc1_hpcooling | 6 | 1 | 1 | 34 | 1 |
UI800, BC400 | thermostat | 4 | coolingon | cooling on | boolean | | False | binary_sensor.thermostat_hc1_cooling_on | binary_sensor.thermostat_hc1_coolingon | 6 | 1 | 1 | 35 | 1 |
UI800, BC400 | thermostat | 4 | hpmode | HP Mode | enum [heating|cooling|heating & cooling] | | True | select.thermostat_hc1_HP_Mode | select.thermostat_hc1_hpmode | 6 | 1 | 1 | 36 | 1 |
UI800, BC400 | thermostat | 4 | dewoffset | dew point offset | uint8 (>=2<=10) | K | True | number.thermostat_hc1_dew_point_offset | number.thermostat_hc1_dewoffset | 6 | 1 | 1 | 37 | 1 |
UI800, BC400 | thermostat | 4 | roomtempdiff | room temp difference | uint8 (>=0<=254) | K | True | number.thermostat_hc1_room_temp_difference | number.thermostat_hc1_roomtempdiff | 6 | 1 | 1 | 38 | 1 |
UI800, BC400 | thermostat | 4 | hpminflowtemp | HP min. flow temp. | uint8 (>=0<=254) | C | True | number.thermostat_hc1_HP_min._flow_temp. | number.thermostat_hc1_hpminflowtemp | 6 | 1 | 1 | 39 | 1 |
UI800, BC400 | thermostat | 4 | control | control device | enum [off|-|RC100|RC100H|-|RC120RF|RC220/RT800|single] | | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | 6 | 1 | 1 | 40 | 1 |
UI800, BC400 | thermostat | 4 | remotetemp | room temperature from remote | cmd [] (>=-1<=101) | C | True | sensor.thermostat_hc1_room_temperature_from_remote | sensor.thermostat_hc1_remotetemp | 6 | 1 | 1/10 | 41 | 1 |
UI800, BC400 | thermostat | 4 | remotehum | room humidity from remote | cmd [] (>=-1<=101) | % | True | sensor.thermostat_hc1_room_humidity_from_remote | sensor.thermostat_hc1_remotehum | 6 | 1 | 1 | 42 | 1 |
UI800, BC400 | thermostat | 4 | heatondelay | heat-on delay | uint8 (>=1<=48) | hours | True | number.thermostat_hc1_heat-on_delay | number.thermostat_hc1_heatondelay | 6 | 1 | 1 | 43 | 1 |
UI800, BC400 | thermostat | 4 | heatoffdelay | heat-off delay | uint8 (>=1<=48) | hours | True | number.thermostat_hc1_heat-off_delay | number.thermostat_hc1_heatoffdelay | 6 | 1 | 1 | 44 | 1 |
UI800, BC400 | thermostat | 4 | instantstart | instant start | uint8 (>=1<=10) | K | True | number.thermostat_hc1_instant_start | number.thermostat_hc1_instantstart | 6 | 1 | 1 | 45 | 1 |
UI800, BC400 | thermostat | 4 | boost | boost mode | boolean | | True | switch.thermostat_hc1_boost_mode | switch.thermostat_hc1_boost | 6 | 1 | 1 | 46 | 1 |
UI800, BC400 | thermostat | 4 | boosttime | boost time | uint8 (>=0<=254) | hours | True | number.thermostat_hc1_boost_time | number.thermostat_hc1_boosttime | 6 | 1 | 1 | 47 | 1 |
UI800, BC400 | thermostat | 4 | coolstart | cooling starttemp | uint8 (>=20<=35) | C | True | number.thermostat_hc1_cooling_starttemp | number.thermostat_hc1_coolstart | 6 | 1 | 1 | 48 | 1 |
UI800, BC400 | thermostat | 4 | coolondelay | cooling on delay | uint8 (>=1<=48) | hours | True | number.thermostat_hc1_cooling_on_delay | number.thermostat_hc1_coolondelay | 6 | 1 | 1 | 49 | 1 |
UI800, BC400 | thermostat | 4 | cooloffdelay | cooling off delay | uint8 (>=1<=48) | hours | True | number.thermostat_hc1_cooling_off_delay | number.thermostat_hc1_cooloffdelay | 6 | 1 | 1 | 50 | 1 |
UI800, BC400 | thermostat | 4 | switchprogmode | switch program mode | enum [level|absolute] | | True | select.thermostat_hc1_switch_program_mode | select.thermostat_hc1_switchprogmode | 6 | 1 | 1 | 51 | 1 |
UI800, BC400 | thermostat | 4 | mode | operating mode | enum [off|eco+|eco|comfort|auto] | | True | select.thermostat_dhw_operating_mode | select.thermostat_dhw_mode | 6 | 9 | 1 | 0 | 1 |
UI800, BC400 | thermostat | 4 | settemp | set temperature | uint8 (>=0<=254) | C | True | number.thermostat_dhw_set_temperature | number.thermostat_dhw_settemp | 6 | 9 | 1 | 1 | 1 |
UI800, BC400 | thermostat | 4 | settemplow | set low temperature | uint8 (>=0<=254) | C | True | number.thermostat_dhw_set_low_temperature | number.thermostat_dhw_settemplow | 6 | 9 | 1 | 2 | 1 |
UI800, BC400 | thermostat | 4 | circmode | circulation pump mode | enum [off|on|auto|own prog] | | True | select.thermostat_dhw_circulation_pump_mode | select.thermostat_dhw_circmode | 6 | 9 | 1 | 3 | 1 |
UI800, BC400 | thermostat | 4 | chargeduration | charge duration | uint8 (>=0<=3810) | minutes | True | number.thermostat_dhw_charge_duration | number.thermostat_dhw_chargeduration | 6 | 9 | 15 | 4 | 1 |
UI800, BC400 | thermostat | 4 | charge | charge | boolean | | True | switch.thermostat_dhw_charge | switch.thermostat_dhw_charge | 6 | 9 | 1 | 5 | 1 |
UI800, BC400 | thermostat | 4 | extra | extra | uint8 (>=0<=254) | C | False | sensor.thermostat_dhw_extra | sensor.thermostat_dhw_extra | 6 | 9 | 1 | 6 | 1 |
UI800, BC400 | thermostat | 4 | disinfecting | disinfecting | boolean | | True | switch.thermostat_dhw_disinfecting | switch.thermostat_dhw_disinfecting | 6 | 9 | 1 | 7 | 1 |
UI800, BC400 | thermostat | 4 | disinfectday | disinfection day | enum [mo|tu|we|th|fr|sa|su|all] | | True | select.thermostat_dhw_disinfection_day | select.thermostat_dhw_disinfectday | 6 | 9 | 1 | 8 | 1 |
UI800, BC400 | thermostat | 4 | disinfecttime | disinfection time | uint8 (>=0<=1431) | minutes | True | number.thermostat_dhw_disinfection_time | number.thermostat_dhw_disinfecttime | 6 | 9 | 15 | 9 | 1 |
UI800, BC400 | thermostat | 4 | dailyheating | daily heating | boolean | | True | switch.thermostat_dhw_daily_heating | switch.thermostat_dhw_dailyheating | 6 | 9 | 1 | 10 | 1 |
UI800, BC400 | thermostat | 4 | dailyheattime | daily heating time | uint8 (>=0<=1431) | minutes | True | number.thermostat_dhw_daily_heating_time | number.thermostat_dhw_dailyheattime | 6 | 9 | 15 | 11 | 1 |
RC10 | thermostat | 65 | errorcode | error code | string | | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | 6 | 0 | 1 | 0 | 8 |
RC10 | thermostat | 65 | lastcode | last error code | string | | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | 6 | 0 | 1 | 8 | 25 |
RC10 | thermostat | 65 | datetime | date/time | string | | False | sensor.thermostat_date/time | sensor.thermostat_datetime | 6 | 0 | 1 | 33 | 13 |
RC10 | thermostat | 65 | minexttemp | minimal external temperature | int8 (>=-126<=126) | C | True | number.thermostat_minimal_external_temperature | number.thermostat_minexttemp | 6 | 0 | 1 | 51 | 1 |
RC10 | thermostat | 65 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp | 6 | 1 | 1/2 | 0 | 1 |
RC10 | thermostat | 65 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp | 6 | 1 | 1/10 | 1 | 1 |
RC10 | thermostat | 65 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | 6 | 1 | 1 | 2 | 1 |
RC10 | thermostat | 65 | mode | operating mode | enum [night|day|auto] | | True | select.thermostat_hc1_operating_mode | select.thermostat_hc1_mode | 6 | 1 | 1 | 3 | 1 |
RC10 | thermostat | 65 | modetype | mode type | enum [night|day] | | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | 6 | 1 | 1 | 4 | 1 |
RC10 | thermostat | 65 | daytemp | day temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_day_temperature | number.thermostat_hc1_daytemp | 6 | 1 | 1/2 | 52 | 1 |
RC10 | thermostat | 65 | nighttemp | night temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_night_temperature | number.thermostat_hc1_nighttemp | 6 | 1 | 1/2 | 53 | 1 |
RC10 | thermostat | 65 | program | program | enum [family|morning|evening|am|pm|midday|singles|seniors] | | True | select.thermostat_hc1_program | select.thermostat_hc1_program | 6 | 1 | 1 | 25 | 1 |
RC10 | thermostat | 65 | minflowtemp | min flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp | 6 | 1 | 1 | 11 | 1 |
RC10 | thermostat | 65 | maxflowtemp | max flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp | 6 | 1 | 1 | 12 | 1 |
RC10 | thermostat | 65 | tempautotemp | temporary set temperature automode | uint8 (>=0<=127) | C | True | number.thermostat_hc1_temporary_set_temperature_automode | number.thermostat_hc1_tempautotemp | 6 | 1 | 1/2 | 26 | 1 |
RC10 | thermostat | 65 | heatingtype | heating type | enum [off|radiator|convector|floor] | | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | 6 | 1 | 1 | 19 | 1 |
RC10 | thermostat | 65 | summertemp | summer temperature | uint8 (>=10<=30) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp | 6 | 1 | 1 | 8 | 1 |
RC10 | thermostat | 65 | summermode | summer mode | enum [winter|summer] | | False | sensor.thermostat_hc1_summer_mode | sensor.thermostat_hc1_summermode | 6 | 1 | 1 | 22 | 1 |
RC30 | thermostat | 67 | errorcode | error code | string | | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | 6 | 0 | 1 | 0 | 8 |
RC30 | thermostat | 67 | lastcode | last error code | string | | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | 6 | 0 | 1 | 8 | 25 |
RC30 | thermostat | 67 | datetime | date/time | string | | False | sensor.thermostat_date/time | sensor.thermostat_datetime | 6 | 0 | 1 | 33 | 13 |
RC30 | thermostat | 67 | display | display | enum [internal temperature|internal setpoint|external temperature|burner temperature|dhw temperature|functioning mode|time|date|smoke temperature] | | True | select.thermostat_display | select.thermostat_display | 6 | 0 | 1 | 63 | 1 |
RC30 | thermostat | 67 | language | language | enum [german|dutch|french|italian] | | False | sensor.thermostat_language | sensor.thermostat_language | 6 | 0 | 1 | 64 | 1 |
RC30 | thermostat | 67 | clockoffset | clock offset | int8 (>=-126<=126) | seconds | True | number.thermostat_clock_offset | number.thermostat_clockoffset | 6 | 0 | 1 | 65 | 1 |
RC30 | thermostat | 67 | intoffset | internal temperature offset | int8 (>=-12<=12) | C | True | number.thermostat_internal_temperature_offset | number.thermostat_intoffset | 6 | 0 | 1/10 | 46 | 1 |
RC30 | thermostat | 67 | minexttemp | minimal external temperature | int8 (>=-126<=126) | C | True | number.thermostat_minimal_external_temperature | number.thermostat_minexttemp | 6 | 0 | 1 | 51 | 1 |
RC30 | thermostat | 67 | inttemp1 | temperature sensor 1 | int16 (>=-3199<=3199) | C | False | sensor.thermostat_temperature_sensor_1 | sensor.thermostat_inttemp1 | 6 | 0 | 1/10 | 66 | 1 |
RC30 | thermostat | 67 | inttemp2 | temperature sensor 2 | int16 (>=-3199<=3199) | C | False | sensor.thermostat_temperature_sensor_2 | sensor.thermostat_inttemp2 | 6 | 0 | 1/10 | 67 | 1 |
RC30 | thermostat | 67 | damping | damping outdoor temperature | boolean | | True | switch.thermostat_damping_outdoor_temperature | switch.thermostat_damping | 6 | 0 | 1 | 52 | 1 |
RC30 | thermostat | 67 | dampedoutdoortemp | damped outdoor temperature | int8 (>=-126<=126) | C | False | sensor.thermostat_damped_outdoor_temperature | sensor.thermostat_dampedoutdoortemp | 6 | 0 | 1 | 48 | 1 |
RC30 | thermostat | 67 | building | building type | enum [light|medium|heavy] | | True | select.thermostat_building_type | select.thermostat_building | 6 | 0 | 1 | 50 | 1 |
RC30 | thermostat | 67 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp | 6 | 1 | 1/2 | 0 | 1 |
RC30 | thermostat | 67 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp | 6 | 1 | 1/10 | 1 | 1 |
RC30 | thermostat | 67 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | 6 | 1 | 1 | 2 | 1 |
RC30 | thermostat | 67 | mode | operating mode | enum [night|day|auto] | | True | select.thermostat_hc1_operating_mode | select.thermostat_hc1_mode | 6 | 1 | 1 | 3 | 1 |
RC30 | thermostat | 67 | modetype | mode type | enum [night|day] | | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | 6 | 1 | 1 | 4 | 1 |
RC30 | thermostat | 67 | daytemp | day temperature | uint8 (>=10<=30) | C | True | number.thermostat_hc1_day_temperature | number.thermostat_hc1_daytemp | 6 | 1 | 1/2 | 52 | 1 |
RC30 | thermostat | 67 | nighttemp | night temperature | uint8 (>=10<=30) | C | True | number.thermostat_hc1_night_temperature | number.thermostat_hc1_nighttemp | 6 | 1 | 1/2 | 53 | 1 |
RC30 | thermostat | 67 | designtemp | design temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp | 6 | 1 | 1 | 9 | 1 |
RC30 | thermostat | 67 | offsettemp | offset temperature | int8 (>=-5<=5) | C | True | number.thermostat_hc1_offset_temperature | number.thermostat_hc1_offsettemp | 6 | 1 | 1/2 | 10 | 1 |
RC30 | thermostat | 67 | holidaytemp | holiday temperature | uint8 (>=5<=30) | C | True | number.thermostat_hc1_holiday_temperature | number.thermostat_hc1_holidaytemp | 6 | 1 | 1/2 | 54 | 1 |
RC30 | thermostat | 67 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp | 6 | 1 | 1 | 18 | 1 |
RC30 | thermostat | 67 | summertemp | summer temperature | uint8 (>=9<=25) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp | 6 | 1 | 1 | 8 | 1 |
RC30 | thermostat | 67 | summermode | summer mode | enum [winter|summer] | | False | sensor.thermostat_hc1_summer_mode | sensor.thermostat_hc1_summermode | 6 | 1 | 1 | 22 | 1 |
RC30 | thermostat | 67 | holidaymode | holiday mode | boolean | | False | binary_sensor.thermostat_hc1_holiday_mode | binary_sensor.thermostat_hc1_holidaymode | 6 | 1 | 1 | 55 | 1 |
RC30 | thermostat | 67 | nofrosttemp | nofrost temperature | int8 (>=-20<=10) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp | 6 | 1 | 1 | 17 | 1 |
RC30 | thermostat | 67 | nofrostmode | nofrost mode | enum [off|outdoor|room] | | True | select.thermostat_hc1_nofrost_mode | select.thermostat_hc1_nofrostmode | 6 | 1 | 1 | 16 | 1 |
RC30 | thermostat | 67 | roominfluence | room influence | uint8 (>=0<=10) | C | True | number.thermostat_hc1_room_influence | number.thermostat_hc1_roominfluence | 6 | 1 | 1 | 13 | 1 |
RC30 | thermostat | 67 | minflowtemp | min flow temperature | uint8 (>=5<=70) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp | 6 | 1 | 1 | 11 | 1 |
RC30 | thermostat | 67 | maxflowtemp | max flow temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp | 6 | 1 | 1 | 12 | 1 |
RC30 | thermostat | 67 | flowtempoffset | flow temperature offset for mixer | uint8 (>=0<=20) | C | True | number.thermostat_hc1_flow_temperature_offset_for_mixer | number.thermostat_hc1_flowtempoffset | 6 | 1 | 1 | 56 | 1 |
RC30 | thermostat | 67 | heatingtype | heating type | enum [off|radiator|convector|floor] | | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | 6 | 1 | 1 | 19 | 1 |
RC30 | thermostat | 67 | reducemode | reduce mode | enum [nofrost|reduce|room|outdoor] | | True | select.thermostat_hc1_reduce_mode | select.thermostat_hc1_reducemode | 6 | 1 | 1 | 30 | 1 |
RC30 | thermostat | 67 | controlmode | control mode | enum [outdoor|room] | | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | 6 | 1 | 1 | 24 | 1 |
RC30 | thermostat | 67 | control | control device | enum [off|RC20|RC3x] | | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | 6 | 1 | 1 | 40 | 1 |
RC30 | thermostat | 67 | holidays | holiday dates | string | | True | sensor.thermostat_hc1_holiday_dates | sensor.thermostat_hc1_holidays | 6 | 1 | 1 | 57 | 13 |
RC30 | thermostat | 67 | vacations | vacation dates | string | | True | sensor.thermostat_hc1_vacation_dates | sensor.thermostat_hc1_vacations | 6 | 1 | 1 | 70 | 13 |
RC30 | thermostat | 67 | program | program | enum [own 1|family|morning|evening|am|pm|midday|singles|seniors|new|own 2] | | True | select.thermostat_hc1_program | select.thermostat_hc1_program | 6 | 1 | 1 | 25 | 1 |
RC30 | thermostat | 67 | pause | pause time | uint8 (>=0<=99) | hours | True | number.thermostat_hc1_pause_time | number.thermostat_hc1_pause | 6 | 1 | 1 | 83 | 1 |
RC30 | thermostat | 67 | party | party time | uint8 (>=0<=99) | hours | True | number.thermostat_hc1_party_time | number.thermostat_hc1_party | 6 | 1 | 1 | 84 | 1 |
RC30 | thermostat | 67 | tempautotemp | temporary set temperature automode | uint8 (>=0<=30) | C | True | number.thermostat_hc1_temporary_set_temperature_automode | number.thermostat_hc1_tempautotemp | 6 | 1 | 1/2 | 26 | 1 |
RC30 | thermostat | 67 | noreducetemp | no reduce below temperature | int8 (>=-31<=10) | C | True | number.thermostat_hc1_no_reduce_below_temperature | number.thermostat_hc1_noreducetemp | 6 | 1 | 1 | 31 | 1 |
RC30 | thermostat | 67 | reducetemp | off/reduce switch temperature | int8 (>=-20<=10) | C | True | number.thermostat_hc1_off/reduce_switch_temperature | number.thermostat_hc1_reducetemp | 6 | 1 | 1 | 32 | 1 |
RC30 | thermostat | 67 | vacreducetemp | vacations off/reduce switch temperature | int8 (>=-20<=10) | C | True | number.thermostat_hc1_vacations_off/reduce_switch_temperature | number.thermostat_hc1_vacreducetemp | 6 | 1 | 1 | 85 | 1 |
RC30 | thermostat | 67 | vacreducemode | vacations reduce mode | enum [nofrost|reduce|room|outdoor] | | True | select.thermostat_hc1_vacations_reduce_mode | select.thermostat_hc1_vacreducemode | 6 | 1 | 1 | 86 | 1 |
RC30 | thermostat | 67 | remotetemp | room temperature from remote | cmd [] (>=-1<=101) | C | True | sensor.thermostat_hc1_room_temperature_from_remote | sensor.thermostat_hc1_remotetemp | 6 | 1 | 1/10 | 41 | 1 |
RC30 | thermostat | 67 | dhwprio | dhw priority | boolean | | True | switch.thermostat_hc1_dhw_priority | switch.thermostat_hc1_dhwprio | 6 | 1 | 1 | 33 | 1 |
RC30 | thermostat | 67 | switchonoptimization | switch-on optimization | boolean | | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | 6 | 1 | 1 | 29 | 1 |
RC30 | thermostat | 67 | switchtime1 | own1 program switchtime | string | | True | sensor.thermostat_hc1_own1_program_switchtime | sensor.thermostat_hc1_switchtime1 | 6 | 1 | 1 | 87 | 8 |
RC30 | thermostat | 67 | switchtime2 | own2 program switchtime | string | | True | sensor.thermostat_hc1_own2_program_switchtime | sensor.thermostat_hc1_switchtime2 | 6 | 1 | 1 | 95 | 8 |
RC30 | thermostat | 67 | mode | operating mode | enum [off|on|auto] | | True | select.thermostat_dhw_operating_mode | select.thermostat_dhw_mode | 6 | 9 | 1 | 0 | 1 |
RC30 | thermostat | 67 | circmode | circulation pump mode | enum [off|on|auto] | | True | select.thermostat_dhw_circulation_pump_mode | select.thermostat_dhw_circmode | 6 | 9 | 1 | 3 | 1 |
RC30 | thermostat | 67 | progmode | program | enum [std prog|own prog] | | True | select.thermostat_dhw_program | select.thermostat_dhw_progmode | 6 | 9 | 1 | 12 | 1 |
RC30 | thermostat | 67 | circprog | circulation program | enum [std prog|own prog] | | True | select.thermostat_dhw_circulation_program | select.thermostat_dhw_circprog | 6 | 9 | 1 | 13 | 1 |
RC30 | thermostat | 67 | disinfecting | disinfecting | boolean | | True | switch.thermostat_dhw_disinfecting | switch.thermostat_dhw_disinfecting | 6 | 9 | 1 | 7 | 1 |
RC30 | thermostat | 67 | disinfectday | disinfection day | enum [mo|tu|we|th|fr|sa|su|all] | | True | select.thermostat_dhw_disinfection_day | select.thermostat_dhw_disinfectday | 6 | 9 | 1 | 8 | 1 |
RC30 | thermostat | 67 | disinfecthour | disinfection hour | uint8 (>=0<=23) | | True | number.thermostat_dhw_disinfection_hour | number.thermostat_dhw_disinfecthour | 6 | 9 | 1 | 14 | 1 |
RC30 | thermostat | 67 | maxtemp | maximum temperature | uint8 (>=0<=254) | C | True | number.thermostat_dhw_maximum_temperature | number.thermostat_dhw_maxtemp | 6 | 9 | 1 | 15 | 1 |
RC30 | thermostat | 67 | onetimekey | one time key function | boolean | | True | switch.thermostat_dhw_one_time_key_function | switch.thermostat_dhw_onetimekey | 6 | 9 | 1 | 16 | 1 |
RC30 | thermostat | 67 | switchtimeWW | program switchtime warm water | string | | True | sensor.thermostat_dhw_program_switchtime_warm_water | sensor.thermostat_dhw_switchtimeWW | 6 | 9 | 1 | 17 | 11 |
RC30 | thermostat | 67 | circswitchtime | circulation program switchtime | string | | True | sensor.thermostat_dhw_circulation_program_switchtime | sensor.thermostat_dhw_circswitchtime | 6 | 9 | 1 | 28 | 8 |
RC30 | thermostat | 67 | holidays | holiday dates | string | | True | sensor.thermostat_dhw_holiday_dates | sensor.thermostat_dhw_holidays | 6 | 9 | 1 | 36 | 13 |
RC30 | thermostat | 67 | vacations | vacation dates | string | | True | sensor.thermostat_dhw_vacation_dates | sensor.thermostat_dhw_vacations | 6 | 9 | 1 | 49 | 13 |
RC20, Moduline 300 | thermostat | 77 | errorcode | error code | string | | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | 6 | 0 | 1 | 0 | 8 |
RC20, Moduline 300 | thermostat | 77 | lastcode | last error code | string | | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | 6 | 0 | 1 | 8 | 25 |
RC20, Moduline 300 | thermostat | 77 | datetime | date/time | string | | False | sensor.thermostat_date/time | sensor.thermostat_datetime | 6 | 0 | 1 | 33 | 13 |
RC20, Moduline 300 | thermostat | 77 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp | 6 | 1 | 1/2 | 0 | 1 |
RC20, Moduline 300 | thermostat | 77 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp | 6 | 1 | 1/10 | 1 | 1 |
RC20, Moduline 300 | thermostat | 77 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | 6 | 1 | 1 | 2 | 1 |
RC20, Moduline 300 | thermostat | 77 | mode | operating mode | enum [off|manual|auto] | | True | select.thermostat_hc1_operating_mode | select.thermostat_hc1_mode | 6 | 1 | 1 | 3 | 1 |
RC20, Moduline 300 | thermostat | 77 | manualtemp | manual temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_manual_temperature | number.thermostat_hc1_manualtemp | 6 | 1 | 1/2 | 6 | 1 |
RC20, Moduline 300 | thermostat | 77 | offtemp | temperature when mode is off | uint8 (>=0<=127) | C | True | number.thermostat_hc1_temperature_when_mode_is_off | number.thermostat_hc1_offtemp | 6 | 1 | 1/2 | 103 | 1 |
RC20, Moduline 300 | thermostat | 77 | daytemp2 | day temperature T2 | uint8 (>=0<=127) | C | True | number.thermostat_hc1_day_temperature_T2 | number.thermostat_hc1_daytemp2 | 6 | 1 | 1/2 | 104 | 1 |
RC20, Moduline 300 | thermostat | 77 | daytemp3 | day temperature T3 | uint8 (>=0<=127) | C | True | number.thermostat_hc1_day_temperature_T3 | number.thermostat_hc1_daytemp3 | 6 | 1 | 1/2 | 105 | 1 |
RC20, Moduline 300 | thermostat | 77 | daytemp4 | day temperature T4 | uint8 (>=0<=127) | C | True | number.thermostat_hc1_day_temperature_T4 | number.thermostat_hc1_daytemp4 | 6 | 1 | 1/2 | 106 | 1 |
RC20, Moduline 300 | thermostat | 77 | nighttemp | night temperature T1 | uint8 (>=0<=127) | C | True | number.thermostat_hc1_night_temperature_T1 | number.thermostat_hc1_nighttemp | 6 | 1 | 1/2 | 53 | 1 |
RC20, Moduline 300 | thermostat | 77 | switchtime | program switchtime | string | | True | sensor.thermostat_hc1_program_switchtime | sensor.thermostat_hc1_switchtime | 6 | 1 | 1 | 107 | 8 |
Moduline 400 | thermostat | 78 | errorcode | error code | string | | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | 6 | 0 | 1 | 0 | 8 |
Moduline 400 | thermostat | 78 | lastcode | last error code | string | | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | 6 | 0 | 1 | 8 | 25 |
Moduline 400 | thermostat | 78 | datetime | date/time | string | | False | sensor.thermostat_date/time | sensor.thermostat_datetime | 6 | 0 | 1 | 33 | 13 |
Moduline 400 | thermostat | 78 | clockoffset | clock offset | int8 (>=-126<=126) | seconds | True | number.thermostat_clock_offset | number.thermostat_clockoffset | 6 | 0 | 1 | 65 | 1 |
Moduline 400 | thermostat | 78 | autodst | automatic change daylight saving time | boolean | | True | switch.thermostat_automatic_change_daylight_saving_time | switch.thermostat_autodst | 6 | 0 | 1 | 68 | 1 |
Moduline 400 | thermostat | 78 | language | language | enum [german|dutch] | | True | select.thermostat_language | select.thermostat_language | 6 | 0 | 1 | 64 | 1 |
Moduline 400 | thermostat | 78 | backlight | key backlight | boolean | | True | switch.thermostat_key_backlight | switch.thermostat_backlight | 6 | 0 | 1 | 69 | 1 |
Moduline 400 | thermostat | 78 | brightness | screen brightness | int8 (>=-15<=15) | | True | number.thermostat_screen_brightness | number.thermostat_brightness | 6 | 0 | 1 | 70 | 1 |
Moduline 400 | thermostat | 78 | mixingvalves | mixing valves | uint8 (>=0<=2) | | True | number.thermostat_mixing_valves | number.thermostat_mixingvalves | 6 | 0 | 1 | 71 | 1 |
Moduline 400 | thermostat | 78 | building | building type | enum [light|medium|heavy] | | True | select.thermostat_building_type | select.thermostat_building | 6 | 0 | 1 | 50 | 1 |
Moduline 400 | thermostat | 78 | heatingpid | heating PID | enum [fast|medium|slow] | | True | select.thermostat_heating_PID | select.thermostat_heatingpid | 6 | 0 | 1 | 72 | 1 |
Moduline 400 | thermostat | 78 | preheating | preheating in the clock program | boolean | | True | switch.thermostat_preheating_in_the_clock_program | switch.thermostat_preheating | 6 | 0 | 1 | 73 | 1 |
Moduline 400 | thermostat | 78 | intoffset | internal temperature offset | int8 (>=-12<=12) | C | True | number.thermostat_internal_temperature_offset | number.thermostat_intoffset | 6 | 0 | 1/10 | 46 | 1 |
Moduline 400 | thermostat | 78 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp | 6 | 1 | 1/2 | 0 | 1 |
Moduline 400 | thermostat | 78 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp | 6 | 1 | 1/10 | 1 | 1 |
Moduline 400 | thermostat | 78 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | 6 | 1 | 1 | 2 | 1 |
Moduline 400 | thermostat | 78 | mode | operating mode | enum [off|manual|auto] | | True | select.thermostat_hc1_operating_mode | select.thermostat_hc1_mode | 6 | 1 | 1 | 3 | 1 |
Moduline 400 | thermostat | 78 | pause | pause time | uint8 (>=0<=254) | hours | True | number.thermostat_hc1_pause_time | number.thermostat_hc1_pause | 6 | 1 | 1 | 83 | 1 |
Moduline 400 | thermostat | 78 | party | party time | uint8 (>=0<=254) | hours | True | number.thermostat_hc1_party_time | number.thermostat_hc1_party | 6 | 1 | 1 | 84 | 1 |
Moduline 400 | thermostat | 78 | vacations1 | vacation dates 1 | string | | True | sensor.thermostat_hc1_vacation_dates_1 | sensor.thermostat_hc1_vacations1 | 6 | 1 | 1 | 115 | 11 |
Moduline 400 | thermostat | 78 | vacations2 | vacation dates 2 | string | | True | sensor.thermostat_hc1_vacation_dates_2 | sensor.thermostat_hc1_vacations2 | 6 | 1 | 1 | 126 | 11 |
Moduline 400 | thermostat | 78 | vacations3 | vacation dates 3 | string | | True | sensor.thermostat_hc1_vacation_dates_3 | sensor.thermostat_hc1_vacations3 | 6 | 1 | 1 | 137 | 11 |
Moduline 400 | thermostat | 78 | vacations4 | vacation dates 4 | string | | True | sensor.thermostat_hc1_vacation_dates_4 | sensor.thermostat_hc1_vacations4 | 6 | 1 | 1 | 148 | 11 |
Moduline 400 | thermostat | 78 | vacations5 | vacation dates 5 | string | | True | sensor.thermostat_hc1_vacation_dates_5 | sensor.thermostat_hc1_vacations5 | 6 | 1 | 1 | 159 | 11 |
Moduline 400 | thermostat | 78 | vacations6 | vacation dates 6 | string | | True | sensor.thermostat_hc1_vacation_dates_6 | sensor.thermostat_hc1_vacations6 | 6 | 1 | 1 | 170 | 11 |
Moduline 400 | thermostat | 78 | vacations7 | vacation dates 7 | string | | True | sensor.thermostat_hc1_vacation_dates_7 | sensor.thermostat_hc1_vacations7 | 6 | 1 | 1 | 181 | 11 |
Moduline 400 | thermostat | 78 | program | program | enum [own 1|family|morning|evening|am|pm|midday|singles|seniors|new|own 2] | | True | select.thermostat_hc1_program | select.thermostat_hc1_program | 6 | 1 | 1 | 25 | 1 |
Moduline 400 | thermostat | 78 | switchtime1 | own1 program switchtime | string | | True | sensor.thermostat_hc1_own1_program_switchtime | sensor.thermostat_hc1_switchtime1 | 6 | 1 | 1 | 87 | 8 |
Moduline 400 | thermostat | 78 | heatingtype | heating type | enum [off|radiator|convector|floor] | | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | 6 | 1 | 1 | 19 | 1 |
Moduline 400 | thermostat | 78 | controlmode | control mode | enum [outdoor|room] | | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | 6 | 1 | 1 | 24 | 1 |
Moduline 400 | thermostat | 78 | holidaytemp | holiday temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_holiday_temperature | number.thermostat_hc1_holidaytemp | 6 | 1 | 1/2 | 54 | 1 |
Moduline 400 | thermostat | 78 | nighttemp | night temperature T1 | uint8 (>=0<=127) | C | True | number.thermostat_hc1_night_temperature_T1 | number.thermostat_hc1_nighttemp | 6 | 1 | 1/2 | 53 | 1 |
Moduline 400 | thermostat | 78 | daytemp2 | day temperature T2 | uint8 (>=0<=127) | C | True | number.thermostat_hc1_day_temperature_T2 | number.thermostat_hc1_daytemp2 | 6 | 1 | 1/2 | 104 | 1 |
Moduline 400 | thermostat | 78 | daytemp3 | day temperature T3 | uint8 (>=0<=127) | C | True | number.thermostat_hc1_day_temperature_T3 | number.thermostat_hc1_daytemp3 | 6 | 1 | 1/2 | 105 | 1 |
Moduline 400 | thermostat | 78 | daytemp4 | day temperature T4 | uint8 (>=0<=127) | C | True | number.thermostat_hc1_day_temperature_T4 | number.thermostat_hc1_daytemp4 | 6 | 1 | 1/2 | 106 | 1 |
Moduline 400 | thermostat | 78 | manualtemp | manual temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_manual_temperature | number.thermostat_hc1_manualtemp | 6 | 1 | 1/2 | 6 | 1 |
Moduline 400 | thermostat | 78 | offtemp | temperature when mode is off | uint8 (>=0<=127) | C | True | number.thermostat_hc1_temperature_when_mode_is_off | number.thermostat_hc1_offtemp | 6 | 1 | 1/2 | 103 | 1 |
Moduline 400 | thermostat | 78 | mode | operating mode | enum [on|off|auto] | | True | select.thermostat_dhw_operating_mode | select.thermostat_dhw_mode | 6 | 9 | 1 | 0 | 1 |
Moduline 400 | thermostat | 78 | whenmodeoff | when thermostat mode off | boolean | | True | switch.thermostat_dhw_when_thermostat_mode_off | switch.thermostat_dhw_whenmodeoff | 6 | 9 | 1 | 62 | 1 |
Moduline 400 | thermostat | 78 | disinfecting | disinfecting | boolean | | True | switch.thermostat_dhw_disinfecting | switch.thermostat_dhw_disinfecting | 6 | 9 | 1 | 7 | 1 |
Moduline 400 | thermostat | 78 | disinfectday | disinfection day | enum [mo|tu|we|th|fr|sa|su|all] | | True | select.thermostat_dhw_disinfection_day | select.thermostat_dhw_disinfectday | 6 | 9 | 1 | 8 | 1 |
Moduline 400 | thermostat | 78 | disinfecthour | disinfection hour | uint8 (>=0<=23) | | True | number.thermostat_dhw_disinfection_hour | number.thermostat_dhw_disinfecthour | 6 | 9 | 1 | 14 | 1 |
RC10, Moduline 100 | thermostat | 79 | errorcode | error code | string | | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | 6 | 0 | 1 | 0 | 8 |
RC10, Moduline 100 | thermostat | 79 | lastcode | last error code | string | | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | 6 | 0 | 1 | 8 | 25 |
RC10, Moduline 100 | thermostat | 79 | intoffset | internal temperature offset | int8 (>=-12<=12) | C | True | number.thermostat_internal_temperature_offset | number.thermostat_intoffset | 6 | 0 | 1/10 | 46 | 1 |
RC10, Moduline 100 | thermostat | 79 | heatingpid | heating PID | enum [fast|medium|slow] | | True | select.thermostat_heating_PID | select.thermostat_heatingpid | 6 | 0 | 1 | 72 | 1 |
RC10, Moduline 100 | thermostat | 79 | backlight | key backlight | boolean | | True | switch.thermostat_key_backlight | switch.thermostat_backlight | 6 | 0 | 1 | 69 | 1 |
RC10, Moduline 100 | thermostat | 79 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp | 6 | 1 | 1/2 | 0 | 1 |
RC10, Moduline 100 | thermostat | 79 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp | 6 | 1 | 1/10 | 1 | 1 |
RC10, Moduline 100 | thermostat | 79 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | 6 | 1 | 1 | 2 | 1 |
RC10, Moduline 100 | thermostat | 79 | mode | operating mode | enum [nofrost|night|day] | | True | select.thermostat_hc1_operating_mode | select.thermostat_hc1_mode | 6 | 1 | 1 | 3 | 1 |
RC10, Moduline 100 | thermostat | 79 | daytemp | day temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_day_temperature | number.thermostat_hc1_daytemp | 6 | 1 | 1/2 | 52 | 1 |
RC10, Moduline 100 | thermostat | 79 | nighttemp | night temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_night_temperature | number.thermostat_hc1_nighttemp | 6 | 1 | 1/2 | 53 | 1 |
RC10, Moduline 100 | thermostat | 79 | reducehours | duration for nighttemp | uint8 (>=0<=254) | hours | True | number.thermostat_hc1_duration_for_nighttemp | number.thermostat_hc1_reducehours | 6 | 1 | 1 | 192 | 1 |
RC10, Moduline 100 | thermostat | 79 | reduceminutes | remaining time for nightmode | uint16 (>=0<=31999) | minutes | False | sensor.thermostat_hc1_remaining_time_for_nightmode | sensor.thermostat_hc1_reduceminutes | 6 | 1 | 1 | 193 | 1 |
RC10, Moduline 100 | thermostat | 79 | mode | operating mode | enum [on|off|auto] | | True | select.thermostat_dhw_operating_mode | select.thermostat_dhw_mode | 6 | 9 | 1 | 0 | 1 |
Moduline 200 | thermostat | 80 | errorcode | error code | string | | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | 6 | 0 | 1 | 0 | 8 |
Moduline 200 | thermostat | 80 | lastcode | last error code | string | | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | 6 | 0 | 1 | 8 | 25 |
Moduline 200 | thermostat | 80 | intoffset | internal temperature offset | int8 (>=-12<=12) | C | True | number.thermostat_internal_temperature_offset | number.thermostat_intoffset | 6 | 0 | 1/10 | 46 | 1 |
Moduline 200 | thermostat | 80 | heatingpid | heating PID | enum [fast|medium|slow] | | True | select.thermostat_heating_PID | select.thermostat_heatingpid | 6 | 0 | 1 | 72 | 1 |
Moduline 200 | thermostat | 80 | backlight | key backlight | boolean | | True | switch.thermostat_key_backlight | switch.thermostat_backlight | 6 | 0 | 1 | 69 | 1 |
Moduline 200 | thermostat | 80 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp | 6 | 1 | 1/2 | 0 | 1 |
Moduline 200 | thermostat | 80 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp | 6 | 1 | 1/10 | 1 | 1 |
Moduline 200 | thermostat | 80 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | 6 | 1 | 1 | 2 | 1 |
Moduline 200 | thermostat | 80 | mode | operating mode | enum [nofrost|night|day] | | True | select.thermostat_hc1_operating_mode | select.thermostat_hc1_mode | 6 | 1 | 1 | 3 | 1 |
Moduline 200 | thermostat | 80 | daytemp | day temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_day_temperature | number.thermostat_hc1_daytemp | 6 | 1 | 1/2 | 52 | 1 |
Moduline 200 | thermostat | 80 | nighttemp | night temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_night_temperature | number.thermostat_hc1_nighttemp | 6 | 1 | 1/2 | 53 | 1 |
Moduline 200 | thermostat | 80 | reducehours | duration for nighttemp | uint8 (>=0<=254) | hours | True | number.thermostat_hc1_duration_for_nighttemp | number.thermostat_hc1_reducehours | 6 | 1 | 1 | 192 | 1 |
Moduline 200 | thermostat | 80 | reduceminutes | remaining time for nightmode | uint16 (>=0<=31999) | minutes | False | sensor.thermostat_hc1_remaining_time_for_nightmode | sensor.thermostat_hc1_reduceminutes | 6 | 1 | 1 | 193 | 1 |
Moduline 200 | thermostat | 80 | mode | operating mode | enum [on|off|auto] | | True | select.thermostat_dhw_operating_mode | select.thermostat_dhw_mode | 6 | 9 | 1 | 0 | 1 |
RC35 | thermostat | 86 | errorcode | error code | string | | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | 6 | 0 | 1 | 0 | 8 |
RC35 | thermostat | 86 | lastcode | last error code | string | | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | 6 | 0 | 1 | 8 | 25 |
RC35 | thermostat | 86 | datetime | date/time | string | | True | sensor.thermostat_date/time | sensor.thermostat_datetime | 6 | 0 | 1 | 33 | 13 |
RC35 | thermostat | 86 | intoffset | internal temperature offset | int8 (>=-5<=5) | C | True | number.thermostat_internal_temperature_offset | number.thermostat_intoffset | 6 | 0 | 1/10 | 46 | 1 |
RC35 | thermostat | 86 | minexttemp | minimal external temperature | int8 (>=-30<=0) | C | True | number.thermostat_minimal_external_temperature | number.thermostat_minexttemp | 6 | 0 | 1 | 51 | 1 |
RC35 | thermostat | 86 | inttemp1 | temperature sensor 1 | int16 (>=-3199<=3199) | C | False | sensor.thermostat_temperature_sensor_1 | sensor.thermostat_inttemp1 | 6 | 0 | 1/10 | 66 | 1 |
RC35 | thermostat | 86 | inttemp2 | temperature sensor 2 | int16 (>=-3199<=3199) | C | False | sensor.thermostat_temperature_sensor_2 | sensor.thermostat_inttemp2 | 6 | 0 | 1/10 | 67 | 1 |
RC35 | thermostat | 86 | damping | damping outdoor temperature | boolean | | True | switch.thermostat_damping_outdoor_temperature | switch.thermostat_damping | 6 | 0 | 1 | 52 | 1 |
RC35 | thermostat | 86 | dampedoutdoortemp | damped outdoor temperature | int8 (>=-126<=126) | C | False | sensor.thermostat_damped_outdoor_temperature | sensor.thermostat_dampedoutdoortemp | 6 | 0 | 1 | 48 | 1 |
RC35 | thermostat | 86 | building | building type | enum [light|medium|heavy] | | True | select.thermostat_building_type | select.thermostat_building | 6 | 0 | 1 | 50 | 1 |
RC35 | thermostat | 86 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp | 6 | 1 | 1/2 | 0 | 1 |
RC35 | thermostat | 86 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp | 6 | 1 | 1/10 | 1 | 1 |
RC35 | thermostat | 86 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | 6 | 1 | 1 | 2 | 1 |
RC35 | thermostat | 86 | mode | operating mode | enum [night|day|auto] | | True | select.thermostat_hc1_operating_mode | select.thermostat_hc1_mode | 6 | 1 | 1 | 3 | 1 |
RC35 | thermostat | 86 | modetype | mode type | enum [night|day] | | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | 6 | 1 | 1 | 4 | 1 |
RC35 | thermostat | 86 | daytemp | day temperature | uint8 (>=10<=30) | C | True | number.thermostat_hc1_day_temperature | number.thermostat_hc1_daytemp | 6 | 1 | 1/2 | 52 | 1 |
RC35 | thermostat | 86 | nighttemp | night temperature | uint8 (>=10<=30) | C | True | number.thermostat_hc1_night_temperature | number.thermostat_hc1_nighttemp | 6 | 1 | 1/2 | 53 | 1 |
RC35 | thermostat | 86 | designtemp | design temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp | 6 | 1 | 1 | 9 | 1 |
RC35 | thermostat | 86 | offsettemp | offset temperature | int8 (>=-5<=5) | C | True | number.thermostat_hc1_offset_temperature | number.thermostat_hc1_offsettemp | 6 | 1 | 1/2 | 10 | 1 |
RC35 | thermostat | 86 | holidaytemp | holiday temperature | uint8 (>=5<=30) | C | True | number.thermostat_hc1_holiday_temperature | number.thermostat_hc1_holidaytemp | 6 | 1 | 1/2 | 54 | 1 |
RC35 | thermostat | 86 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp | 6 | 1 | 1 | 18 | 1 |
RC35 | thermostat | 86 | summertemp | summer temperature | uint8 (>=9<=25) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp | 6 | 1 | 1 | 8 | 1 |
RC35 | thermostat | 86 | summermode | summer mode | enum [winter|summer] | | False | sensor.thermostat_hc1_summer_mode | sensor.thermostat_hc1_summermode | 6 | 1 | 1 | 22 | 1 |
RC35 | thermostat | 86 | holidaymode | holiday mode | boolean | | False | binary_sensor.thermostat_hc1_holiday_mode | binary_sensor.thermostat_hc1_holidaymode | 6 | 1 | 1 | 55 | 1 |
RC35 | thermostat | 86 | nofrosttemp | nofrost temperature | int8 (>=-20<=10) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp | 6 | 1 | 1 | 17 | 1 |
RC35 | thermostat | 86 | nofrostmode | nofrost mode | enum [off|outdoor|room] | | True | select.thermostat_hc1_nofrost_mode | select.thermostat_hc1_nofrostmode | 6 | 1 | 1 | 16 | 1 |
RC35 | thermostat | 86 | roominfluence | room influence | uint8 (>=0<=10) | C | True | number.thermostat_hc1_room_influence | number.thermostat_hc1_roominfluence | 6 | 1 | 1 | 13 | 1 |
RC35 | thermostat | 86 | minflowtemp | min flow temperature | uint8 (>=5<=70) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp | 6 | 1 | 1 | 11 | 1 |
RC35 | thermostat | 86 | maxflowtemp | max flow temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp | 6 | 1 | 1 | 12 | 1 |
RC35 | thermostat | 86 | flowtempoffset | flow temperature offset for mixer | uint8 (>=0<=20) | C | True | number.thermostat_hc1_flow_temperature_offset_for_mixer | number.thermostat_hc1_flowtempoffset | 6 | 1 | 1 | 56 | 1 |
RC35 | thermostat | 86 | heatingtype | heating type | enum [off|radiator|convector|floor] | | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | 6 | 1 | 1 | 19 | 1 |
RC35 | thermostat | 86 | reducemode | reduce mode | enum [nofrost|reduce|room|outdoor] | | True | select.thermostat_hc1_reduce_mode | select.thermostat_hc1_reducemode | 6 | 1 | 1 | 30 | 1 |
RC35 | thermostat | 86 | controlmode | control mode | enum [outdoor|room] | | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | 6 | 1 | 1 | 24 | 1 |
RC35 | thermostat | 86 | control | control device | enum [off|RC20|RC3x] | | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | 6 | 1 | 1 | 40 | 1 |
RC35 | thermostat | 86 | holidays | holiday dates | string | | True | sensor.thermostat_hc1_holiday_dates | sensor.thermostat_hc1_holidays | 6 | 1 | 1 | 57 | 13 |
RC35 | thermostat | 86 | vacations | vacation dates | string | | True | sensor.thermostat_hc1_vacation_dates | sensor.thermostat_hc1_vacations | 6 | 1 | 1 | 70 | 13 |
RC35 | thermostat | 86 | program | program | enum [own 1|family|morning|evening|am|pm|midday|singles|seniors|new|own 2] | | True | select.thermostat_hc1_program | select.thermostat_hc1_program | 6 | 1 | 1 | 25 | 1 |
RC35 | thermostat | 86 | pause | pause time | uint8 (>=0<=99) | hours | True | number.thermostat_hc1_pause_time | number.thermostat_hc1_pause | 6 | 1 | 1 | 83 | 1 |
RC35 | thermostat | 86 | party | party time | uint8 (>=0<=99) | hours | True | number.thermostat_hc1_party_time | number.thermostat_hc1_party | 6 | 1 | 1 | 84 | 1 |
RC35 | thermostat | 86 | tempautotemp | temporary set temperature automode | uint8 (>=0<=30) | C | True | number.thermostat_hc1_temporary_set_temperature_automode | number.thermostat_hc1_tempautotemp | 6 | 1 | 1/2 | 26 | 1 |
RC35 | thermostat | 86 | noreducetemp | no reduce below temperature | int8 (>=-31<=10) | C | True | number.thermostat_hc1_no_reduce_below_temperature | number.thermostat_hc1_noreducetemp | 6 | 1 | 1 | 31 | 1 |
RC35 | thermostat | 86 | reducetemp | off/reduce switch temperature | int8 (>=-20<=10) | C | True | number.thermostat_hc1_off/reduce_switch_temperature | number.thermostat_hc1_reducetemp | 6 | 1 | 1 | 32 | 1 |
RC35 | thermostat | 86 | vacreducetemp | vacations off/reduce switch temperature | int8 (>=-20<=10) | C | True | number.thermostat_hc1_vacations_off/reduce_switch_temperature | number.thermostat_hc1_vacreducetemp | 6 | 1 | 1 | 85 | 1 |
RC35 | thermostat | 86 | vacreducemode | vacations reduce mode | enum [nofrost|reduce|room|outdoor] | | True | select.thermostat_hc1_vacations_reduce_mode | select.thermostat_hc1_vacreducemode | 6 | 1 | 1 | 86 | 1 |
RC35 | thermostat | 86 | remotetemp | room temperature from remote | cmd [] (>=-1<=101) | C | True | sensor.thermostat_hc1_room_temperature_from_remote | sensor.thermostat_hc1_remotetemp | 6 | 1 | 1/10 | 41 | 1 |
RC35 | thermostat | 86 | dhwprio | dhw priority | boolean | | True | switch.thermostat_hc1_dhw_priority | switch.thermostat_hc1_dhwprio | 6 | 1 | 1 | 33 | 1 |
RC35 | thermostat | 86 | switchonoptimization | switch-on optimization | boolean | | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | 6 | 1 | 1 | 29 | 1 |
RC35 | thermostat | 86 | switchtime1 | own1 program switchtime | string | | True | sensor.thermostat_hc1_own1_program_switchtime | sensor.thermostat_hc1_switchtime1 | 6 | 1 | 1 | 87 | 8 |
RC35 | thermostat | 86 | switchtime2 | own2 program switchtime | string | | True | sensor.thermostat_hc1_own2_program_switchtime | sensor.thermostat_hc1_switchtime2 | 6 | 1 | 1 | 95 | 8 |
RC35 | thermostat | 86 | mode | operating mode | enum [off|on|auto] | | True | select.thermostat_dhw_operating_mode | select.thermostat_dhw_mode | 6 | 9 | 1 | 0 | 1 |
RC35 | thermostat | 86 | circmode | circulation pump mode | enum [off|on|auto] | | True | select.thermostat_dhw_circulation_pump_mode | select.thermostat_dhw_circmode | 6 | 9 | 1 | 3 | 1 |
RC35 | thermostat | 86 | progmode | program | enum [std prog|own prog] | | True | select.thermostat_dhw_program | select.thermostat_dhw_progmode | 6 | 9 | 1 | 12 | 1 |
RC35 | thermostat | 86 | circprog | circulation program | enum [std prog|own prog] | | True | select.thermostat_dhw_circulation_program | select.thermostat_dhw_circprog | 6 | 9 | 1 | 13 | 1 |
RC35 | thermostat | 86 | disinfecting | disinfecting | boolean | | True | switch.thermostat_dhw_disinfecting | switch.thermostat_dhw_disinfecting | 6 | 9 | 1 | 7 | 1 |
RC35 | thermostat | 86 | disinfectday | disinfection day | enum [mo|tu|we|th|fr|sa|su|all] | | True | select.thermostat_dhw_disinfection_day | select.thermostat_dhw_disinfectday | 6 | 9 | 1 | 8 | 1 |
RC35 | thermostat | 86 | disinfecthour | disinfection hour | uint8 (>=0<=23) | | True | number.thermostat_dhw_disinfection_hour | number.thermostat_dhw_disinfecthour | 6 | 9 | 1 | 14 | 1 |
RC35 | thermostat | 86 | maxtemp | maximum temperature | uint8 (>=60<=80) | C | True | number.thermostat_dhw_maximum_temperature | number.thermostat_dhw_maxtemp | 6 | 9 | 1 | 15 | 1 |
RC35 | thermostat | 86 | onetimekey | one time key function | boolean | | True | switch.thermostat_dhw_one_time_key_function | switch.thermostat_dhw_onetimekey | 6 | 9 | 1 | 16 | 1 |
RC35 | thermostat | 86 | switchtimeWW | program switchtime warm water | string | | True | sensor.thermostat_dhw_program_switchtime_warm_water | sensor.thermostat_dhw_switchtimeWW | 6 | 9 | 1 | 17 | 11 |
RC35 | thermostat | 86 | circswitchtime | circulation program switchtime | string | | True | sensor.thermostat_dhw_circulation_program_switchtime | sensor.thermostat_dhw_circswitchtime | 6 | 9 | 1 | 28 | 8 |
RC35 | thermostat | 86 | holidays | holiday dates | string | | True | sensor.thermostat_dhw_holiday_dates | sensor.thermostat_dhw_holidays | 6 | 9 | 1 | 36 | 13 |
RC35 | thermostat | 86 | vacations | vacation dates | string | | True | sensor.thermostat_dhw_vacation_dates | sensor.thermostat_dhw_vacations | 6 | 9 | 1 | 49 | 13 |
RC10, Moduline 100 | thermostat | 90 | errorcode | error code | string | | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | 6 | 0 | 1 | 0 | 8 |
RC10, Moduline 100 | thermostat | 90 | lastcode | last error code | string | | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | 6 | 0 | 1 | 8 | 25 |
RC10, Moduline 100 | thermostat | 90 | datetime | date/time | string | | False | sensor.thermostat_date/time | sensor.thermostat_datetime | 6 | 0 | 1 | 33 | 13 |
RC10, Moduline 100 | thermostat | 90 | minexttemp | minimal external temperature | int8 (>=-126<=126) | C | True | number.thermostat_minimal_external_temperature | number.thermostat_minexttemp | 6 | 0 | 1 | 51 | 1 |
RC10, Moduline 100 | thermostat | 90 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp | 6 | 1 | 1/2 | 0 | 1 |
RC10, Moduline 100 | thermostat | 90 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp | 6 | 1 | 1/10 | 1 | 1 |
RC10, Moduline 100 | thermostat | 90 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | 6 | 1 | 1 | 2 | 1 |
RC10, Moduline 100 | thermostat | 90 | mode | operating mode | enum [night|day|auto] | | True | select.thermostat_hc1_operating_mode | select.thermostat_hc1_mode | 6 | 1 | 1 | 3 | 1 |
RC10, Moduline 100 | thermostat | 90 | modetype | mode type | enum [night|day] | | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | 6 | 1 | 1 | 4 | 1 |
RC10, Moduline 100 | thermostat | 90 | daytemp | day temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_day_temperature | number.thermostat_hc1_daytemp | 6 | 1 | 1/2 | 52 | 1 |
RC10, Moduline 100 | thermostat | 90 | nighttemp | night temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_night_temperature | number.thermostat_hc1_nighttemp | 6 | 1 | 1/2 | 53 | 1 |
RC10, Moduline 100 | thermostat | 90 | program | program | enum [family|morning|evening|am|pm|midday|singles|seniors] | | True | select.thermostat_hc1_program | select.thermostat_hc1_program | 6 | 1 | 1 | 25 | 1 |
RC10, Moduline 100 | thermostat | 90 | minflowtemp | min flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp | 6 | 1 | 1 | 11 | 1 |
RC10, Moduline 100 | thermostat | 90 | maxflowtemp | max flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp | 6 | 1 | 1 | 12 | 1 |
RC10, Moduline 100 | thermostat | 90 | tempautotemp | temporary set temperature automode | uint8 (>=0<=127) | C | True | number.thermostat_hc1_temporary_set_temperature_automode | number.thermostat_hc1_tempautotemp | 6 | 1 | 1/2 | 26 | 1 |
RC10, Moduline 100 | thermostat | 90 | heatingtype | heating type | enum [off|radiator|convector|floor] | | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | 6 | 1 | 1 | 19 | 1 |
RC10, Moduline 100 | thermostat | 90 | summertemp | summer temperature | uint8 (>=10<=30) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp | 6 | 1 | 1 | 8 | 1 |
RC10, Moduline 100 | thermostat | 90 | summermode | summer mode | enum [winter|summer] | | False | sensor.thermostat_hc1_summer_mode | sensor.thermostat_hc1_summermode | 6 | 1 | 1 | 22 | 1 |
RC20RF | thermostat | 93 | errorcode | error code | string | | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | 6 | 0 | 1 | 0 | 8 |
RC20RF | thermostat | 93 | lastcode | last error code | string | | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | 6 | 0 | 1 | 8 | 25 |
RC20RF | thermostat | 93 | datetime | date/time | string | | False | sensor.thermostat_date/time | sensor.thermostat_datetime | 6 | 0 | 1 | 33 | 13 |
RC20RF | thermostat | 93 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp | 6 | 1 | 1/2 | 0 | 1 |
RC20RF | thermostat | 93 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp | 6 | 1 | 1/10 | 1 | 1 |
RC20RF | thermostat | 93 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | 6 | 1 | 1 | 2 | 1 |
RC20RF | thermostat | 93 | mode | operating mode | enum [off|manual|auto] | | True | select.thermostat_hc1_operating_mode | select.thermostat_hc1_mode | 6 | 1 | 1 | 3 | 1 |
RC20RF | thermostat | 93 | manualtemp | manual temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_manual_temperature | number.thermostat_hc1_manualtemp | 6 | 1 | 1/2 | 6 | 1 |
RC20RF | thermostat | 93 | offtemp | temperature when mode is off | uint8 (>=0<=127) | C | True | number.thermostat_hc1_temperature_when_mode_is_off | number.thermostat_hc1_offtemp | 6 | 1 | 1/2 | 103 | 1 |
RC20RF | thermostat | 93 | daytemp2 | day temperature T2 | uint8 (>=0<=127) | C | True | number.thermostat_hc1_day_temperature_T2 | number.thermostat_hc1_daytemp2 | 6 | 1 | 1/2 | 104 | 1 |
RC20RF | thermostat | 93 | daytemp3 | day temperature T3 | uint8 (>=0<=127) | C | True | number.thermostat_hc1_day_temperature_T3 | number.thermostat_hc1_daytemp3 | 6 | 1 | 1/2 | 105 | 1 |
RC20RF | thermostat | 93 | daytemp4 | day temperature T4 | uint8 (>=0<=127) | C | True | number.thermostat_hc1_day_temperature_T4 | number.thermostat_hc1_daytemp4 | 6 | 1 | 1/2 | 106 | 1 |
RC20RF | thermostat | 93 | nighttemp | night temperature T1 | uint8 (>=0<=127) | C | True | number.thermostat_hc1_night_temperature_T1 | number.thermostat_hc1_nighttemp | 6 | 1 | 1/2 | 53 | 1 |
RC20RF | thermostat | 93 | switchtime | program switchtime | string | | True | sensor.thermostat_hc1_program_switchtime | sensor.thermostat_hc1_switchtime | 6 | 1 | 1 | 107 | 8 |
RFM20 Remote | thermostat | 94 | errorcode | error code | string | | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | 6 | 0 | 1 | 0 | 8 |
RFM20 Remote | thermostat | 94 | lastcode | last error code | string | | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | 6 | 0 | 1 | 8 | 25 |
RFM20 Remote | thermostat | 94 | datetime | date/time | string | | False | sensor.thermostat_date/time | sensor.thermostat_datetime | 6 | 0 | 1 | 33 | 13 |
RFM20 Remote | thermostat | 94 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp | 6 | 1 | 1/2 | 0 | 1 |
RFM20 Remote | thermostat | 94 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp | 6 | 1 | 1/10 | 1 | 1 |
RFM20 Remote | thermostat | 94 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | 6 | 1 | 1 | 2 | 1 |
RC25 | thermostat | 151 | errorcode | error code | string | | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | 6 | 0 | 1 | 0 | 8 |
RC25 | thermostat | 151 | lastcode | last error code | string | | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | 6 | 0 | 1 | 8 | 25 |
RC25 | thermostat | 151 | datetime | date/time | string | | False | sensor.thermostat_date/time | sensor.thermostat_datetime | 6 | 0 | 1 | 33 | 13 |
RC25 | thermostat | 151 | minexttemp | minimal external temperature | int8 (>=-126<=126) | C | True | number.thermostat_minimal_external_temperature | number.thermostat_minexttemp | 6 | 0 | 1 | 51 | 1 |
RC25 | thermostat | 151 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp | 6 | 1 | 1/2 | 0 | 1 |
RC25 | thermostat | 151 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp | 6 | 1 | 1/10 | 1 | 1 |
RC25 | thermostat | 151 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | 6 | 1 | 1 | 2 | 1 |
RC25 | thermostat | 151 | mode | operating mode | enum [night|day|auto] | | True | select.thermostat_hc1_operating_mode | select.thermostat_hc1_mode | 6 | 1 | 1 | 3 | 1 |
RC25 | thermostat | 151 | modetype | mode type | enum [night|day] | | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | 6 | 1 | 1 | 4 | 1 |
RC25 | thermostat | 151 | daytemp | day temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_day_temperature | number.thermostat_hc1_daytemp | 6 | 1 | 1/2 | 52 | 1 |
RC25 | thermostat | 151 | nighttemp | night temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_night_temperature | number.thermostat_hc1_nighttemp | 6 | 1 | 1/2 | 53 | 1 |
RC25 | thermostat | 151 | program | program | enum [family|morning|evening|am|pm|midday|singles|seniors] | | True | select.thermostat_hc1_program | select.thermostat_hc1_program | 6 | 1 | 1 | 25 | 1 |
RC25 | thermostat | 151 | minflowtemp | min flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp | 6 | 1 | 1 | 11 | 1 |
RC25 | thermostat | 151 | maxflowtemp | max flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp | 6 | 1 | 1 | 12 | 1 |
RC25 | thermostat | 151 | tempautotemp | temporary set temperature automode | uint8 (>=0<=127) | C | True | number.thermostat_hc1_temporary_set_temperature_automode | number.thermostat_hc1_tempautotemp | 6 | 1 | 1/2 | 26 | 1 |
RC25 | thermostat | 151 | heatingtype | heating type | enum [off|radiator|convector|floor] | | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | 6 | 1 | 1 | 19 | 1 |
RC25 | thermostat | 151 | summertemp | summer temperature | uint8 (>=9<=25) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp | 6 | 1 | 1 | 8 | 1 |
RC25 | thermostat | 151 | summermode | summer mode | enum [winter|summer] | | False | sensor.thermostat_hc1_summer_mode | sensor.thermostat_hc1_summermode | 6 | 1 | 1 | 22 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | errorcode | error code | string | | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | 6 | 0 | 1 | 0 | 8 |
RC200, CW100, CR120, CR50 | thermostat | 157 | lastcode | last error code | string | | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | 6 | 0 | 1 | 8 | 25 |
RC200, CW100, CR120, CR50 | thermostat | 157 | datetime | date/time | string | | True | sensor.thermostat_date/time | sensor.thermostat_datetime | 6 | 0 | 1 | 33 | 13 |
RC200, CW100, CR120, CR50 | thermostat | 157 | intoffset | internal temperature offset | int8 (>=-12<=12) | C | True | number.thermostat_internal_temperature_offset | number.thermostat_intoffset | 6 | 0 | 1/10 | 46 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | floordry | floor drying | enum [off|start|heat|hold|cool|end] | | False | sensor.thermostat_floor_drying | sensor.thermostat_floordry | 6 | 0 | 1 | 47 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | dampedoutdoortemp | damped outdoor temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_damped_outdoor_temperature | sensor.thermostat_dampedoutdoortemp | 6 | 0 | 1/10 | 48 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | floordrytemp | floor drying temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_floor_drying_temperature | sensor.thermostat_floordrytemp | 6 | 0 | 1 | 49 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | building | building type | enum [light|medium|heavy] | | True | select.thermostat_building_type | select.thermostat_building | 6 | 0 | 1 | 50 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | minexttemp | minimal external temperature | int8 (>=-126<=126) | C | True | number.thermostat_minimal_external_temperature | number.thermostat_minexttemp | 6 | 0 | 1 | 51 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | damping | damping outdoor temperature | boolean | | True | switch.thermostat_damping_outdoor_temperature | switch.thermostat_damping | 6 | 0 | 1 | 52 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | hybridstrategy | hybrid control strategy | enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] | | True | select.thermostat_hybrid_control_strategy | select.thermostat_hybridstrategy | 6 | 0 | 1 | 53 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | switchovertemp | outside switchover temperature | int8 (>=-20<=20) | C | True | number.thermostat_outside_switchover_temperature | number.thermostat_switchovertemp | 6 | 0 | 1 | 54 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | energycostratio | energy cost ratio | uint8 (>=0<=20) | | True | number.thermostat_energy_cost_ratio | number.thermostat_energycostratio | 6 | 0 | 1/10 | 55 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | fossilefactor | fossile energy factor | uint8 (>=0<=5) | | True | number.thermostat_fossile_energy_factor | number.thermostat_fossilefactor | 6 | 0 | 1/10 | 56 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | electricfactor | electric energy factor | uint8 (>=0<=5) | | True | number.thermostat_electric_energy_factor | number.thermostat_electricfactor | 6 | 0 | 1/10 | 57 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | delayboiler | delay boiler support | uint8 (>=5<=120) | minutes | True | number.thermostat_delay_boiler_support | number.thermostat_delayboiler | 6 | 0 | 1 | 58 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | tempdiffboiler | temp diff boiler support | uint8 (>=1<=99) | C | True | number.thermostat_temp_diff_boiler_support | number.thermostat_tempdiffboiler | 6 | 0 | 1 | 59 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | pvenabledhw | enable raise dhw | boolean | | True | switch.thermostat_enable_raise_dhw | switch.thermostat_pvenabledhw | 6 | 0 | 1 | 60 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | pvraiseheat | raise heating with PV | int8 (>=0<=5) | K | True | number.thermostat_raise_heating_with_PV | number.thermostat_pvraiseheat | 6 | 0 | 1 | 61 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | pvlowercool | lower cooling with PV | int8 (>=-5<=0) | K | True | number.thermostat_lower_cooling_with_PV | number.thermostat_pvlowercool | 6 | 0 | 1 | 62 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp | 6 | 1 | 1/2 | 0 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp | 6 | 1 | 1/10 | 1 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | 6 | 1 | 1 | 2 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | mode | operating mode | enum [manual|auto] | | True | select.thermostat_hc1_operating_mode | select.thermostat_hc1_mode | 6 | 1 | 1 | 3 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | modetype | mode type | enum [eco|comfort] | | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | 6 | 1 | 1 | 4 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | ecotemp | eco temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_eco_temperature | number.thermostat_hc1_ecotemp | 6 | 1 | 1/2 | 5 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | manualtemp | manual temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_manual_temperature | number.thermostat_hc1_manualtemp | 6 | 1 | 1/2 | 6 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | comforttemp | comfort temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_comfort_temperature | number.thermostat_hc1_comforttemp | 6 | 1 | 1/2 | 7 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | summertemp | summer temperature | uint8 (>=10<=30) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp | 6 | 1 | 1 | 8 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | designtemp | design temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp | 6 | 1 | 1 | 9 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | offsettemp | offset temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_offset_temperature | number.thermostat_hc1_offsettemp | 6 | 1 | 1 | 10 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | minflowtemp | min flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp | 6 | 1 | 1 | 11 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | maxflowtemp | max flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp | 6 | 1 | 1 | 12 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | roominfluence | room influence | uint8 (>=0<=254) | C | True | number.thermostat_hc1_room_influence | number.thermostat_hc1_roominfluence | 6 | 1 | 1 | 13 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | roominflfactor | room influence factor | uint8 (>=0<=25) | | True | number.thermostat_hc1_room_influence_factor | number.thermostat_hc1_roominflfactor | 6 | 1 | 1/10 | 14 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | curroominfl | current room influence | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_influence | sensor.thermostat_hc1_curroominfl | 6 | 1 | 1/10 | 15 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | nofrostmode | nofrost mode | enum [room|outdoor|room outdoor] | | True | select.thermostat_hc1_nofrost_mode | select.thermostat_hc1_nofrostmode | 6 | 1 | 1 | 16 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | nofrosttemp | nofrost temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp | 6 | 1 | 1 | 17 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp | 6 | 1 | 1 | 18 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | heatingtype | heating type | enum [off|radiator|convector|floor] | | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | 6 | 1 | 1 | 19 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | summersetmode | set summer mode | enum [summer|auto|winter] | | True | select.thermostat_hc1_set_summer_mode | select.thermostat_hc1_summersetmode | 6 | 1 | 1 | 20 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | hpoperatingmode | heatpump operating mode | enum [off|auto|heating|cooling] | | True | select.thermostat_hc1_heatpump_operating_mode | select.thermostat_hc1_hpoperatingmode | 6 | 1 | 1 | 21 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | summermode | summer mode | enum [winter|summer] | | False | sensor.thermostat_hc1_summer_mode | sensor.thermostat_hc1_summermode | 6 | 1 | 1 | 22 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | hpoperatingstate | heatpump operating state | enum [heating|off|cooling] | | False | sensor.thermostat_hc1_heatpump_operating_state | sensor.thermostat_hc1_hpoperatingstate | 6 | 1 | 1 | 23 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | controlmode | control mode | enum [optimized|simple|n/a|room|power] | | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | 6 | 1 | 1 | 24 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | program | program | enum [prog 1|prog 2] | | True | select.thermostat_hc1_program | select.thermostat_hc1_program | 6 | 1 | 1 | 25 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | tempautotemp | temporary set temperature automode | int8 (>=-1<=30) | C | True | number.thermostat_hc1_temporary_set_temperature_automode | number.thermostat_hc1_tempautotemp | 6 | 1 | 1/2 | 26 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | remoteseltemp | temporary set temperature from remote | int8 (>=-1<=30) | C | True | number.thermostat_hc1_temporary_set_temperature_from_remote | number.thermostat_hc1_remoteseltemp | 6 | 1 | 1/2 | 27 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | fastheatup | fast heatup | uint8 (>=0<=100) | % | True | number.thermostat_hc1_fast_heatup | number.thermostat_hc1_fastheatup | 6 | 1 | 1 | 28 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | switchonoptimization | switch-on optimization | boolean | | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | 6 | 1 | 1 | 29 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | reducemode | reduce mode | enum [outdoor|room|reduce] | | True | select.thermostat_hc1_reduce_mode | select.thermostat_hc1_reducemode | 6 | 1 | 1 | 30 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | noreducetemp | no reduce below temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_no_reduce_below_temperature | number.thermostat_hc1_noreducetemp | 6 | 1 | 1 | 31 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | reducetemp | off/reduce switch temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_off/reduce_switch_temperature | number.thermostat_hc1_reducetemp | 6 | 1 | 1 | 32 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | dhwprio | dhw priority | boolean | | True | switch.thermostat_hc1_dhw_priority | switch.thermostat_hc1_dhwprio | 6 | 1 | 1 | 33 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | hpcooling | hp cooling | boolean | | True | switch.thermostat_hc1_hp_cooling | switch.thermostat_hc1_hpcooling | 6 | 1 | 1 | 34 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | coolingon | cooling on | boolean | | False | binary_sensor.thermostat_hc1_cooling_on | binary_sensor.thermostat_hc1_coolingon | 6 | 1 | 1 | 35 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | hpmode | HP Mode | enum [heating|cooling|heating & cooling] | | True | select.thermostat_hc1_HP_Mode | select.thermostat_hc1_hpmode | 6 | 1 | 1 | 36 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | dewoffset | dew point offset | uint8 (>=2<=10) | K | True | number.thermostat_hc1_dew_point_offset | number.thermostat_hc1_dewoffset | 6 | 1 | 1 | 37 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | roomtempdiff | room temp difference | uint8 (>=0<=254) | K | True | number.thermostat_hc1_room_temp_difference | number.thermostat_hc1_roomtempdiff | 6 | 1 | 1 | 38 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | hpminflowtemp | HP min. flow temp. | uint8 (>=0<=254) | C | True | number.thermostat_hc1_HP_min._flow_temp. | number.thermostat_hc1_hpminflowtemp | 6 | 1 | 1 | 39 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | control | control device | enum [RC310|RC200|RC100|RC100H|TC100] | | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | 6 | 1 | 1 | 40 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | remotetemp | room temperature from remote | cmd [] (>=-1<=101) | C | True | sensor.thermostat_hc1_room_temperature_from_remote | sensor.thermostat_hc1_remotetemp | 6 | 1 | 1/10 | 41 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | remotehum | room humidity from remote | cmd [] (>=-1<=101) | % | True | sensor.thermostat_hc1_room_humidity_from_remote | sensor.thermostat_hc1_remotehum | 6 | 1 | 1 | 42 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | heatondelay | heat-on delay | uint8 (>=1<=48) | hours | True | number.thermostat_hc1_heat-on_delay | number.thermostat_hc1_heatondelay | 6 | 1 | 1 | 43 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | heatoffdelay | heat-off delay | uint8 (>=1<=48) | hours | True | number.thermostat_hc1_heat-off_delay | number.thermostat_hc1_heatoffdelay | 6 | 1 | 1 | 44 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | instantstart | instant start | uint8 (>=1<=10) | K | True | number.thermostat_hc1_instant_start | number.thermostat_hc1_instantstart | 6 | 1 | 1 | 45 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | boost | boost mode | boolean | | True | switch.thermostat_hc1_boost_mode | switch.thermostat_hc1_boost | 6 | 1 | 1 | 46 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | boosttime | boost time | uint8 (>=0<=254) | hours | True | number.thermostat_hc1_boost_time | number.thermostat_hc1_boosttime | 6 | 1 | 1 | 47 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | coolstart | cooling starttemp | uint8 (>=20<=35) | C | True | number.thermostat_hc1_cooling_starttemp | number.thermostat_hc1_coolstart | 6 | 1 | 1 | 48 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | coolondelay | cooling on delay | uint8 (>=1<=48) | hours | True | number.thermostat_hc1_cooling_on_delay | number.thermostat_hc1_coolondelay | 6 | 1 | 1 | 49 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | cooloffdelay | cooling off delay | uint8 (>=1<=48) | hours | True | number.thermostat_hc1_cooling_off_delay | number.thermostat_hc1_cooloffdelay | 6 | 1 | 1 | 50 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | switchprogmode | switch program mode | enum [level|absolute] | | True | select.thermostat_hc1_switch_program_mode | select.thermostat_hc1_switchprogmode | 6 | 1 | 1 | 51 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | mode | operating mode | enum [off|normal|comfort|auto|own prog] | | True | select.thermostat_dhw_operating_mode | select.thermostat_dhw_mode | 6 | 9 | 1 | 0 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | settemp | set temperature | uint8 (>=0<=254) | C | True | number.thermostat_dhw_set_temperature | number.thermostat_dhw_settemp | 6 | 9 | 1 | 1 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | settemplow | set low temperature | uint8 (>=0<=254) | C | True | number.thermostat_dhw_set_low_temperature | number.thermostat_dhw_settemplow | 6 | 9 | 1 | 2 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | circmode | circulation pump mode | enum [off|on|auto|own prog] | | True | select.thermostat_dhw_circulation_pump_mode | select.thermostat_dhw_circmode | 6 | 9 | 1 | 3 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | chargeduration | charge duration | uint8 (>=0<=3810) | minutes | True | number.thermostat_dhw_charge_duration | number.thermostat_dhw_chargeduration | 6 | 9 | 15 | 4 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | charge | charge | boolean | | True | switch.thermostat_dhw_charge | switch.thermostat_dhw_charge | 6 | 9 | 1 | 5 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | extra | extra | uint8 (>=0<=254) | C | False | sensor.thermostat_dhw_extra | sensor.thermostat_dhw_extra | 6 | 9 | 1 | 6 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | disinfecting | disinfecting | boolean | | True | switch.thermostat_dhw_disinfecting | switch.thermostat_dhw_disinfecting | 6 | 9 | 1 | 7 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | disinfectday | disinfection day | enum [mo|tu|we|th|fr|sa|su|all] | | True | select.thermostat_dhw_disinfection_day | select.thermostat_dhw_disinfectday | 6 | 9 | 1 | 8 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | disinfecttime | disinfection time | uint8 (>=0<=1431) | minutes | True | number.thermostat_dhw_disinfection_time | number.thermostat_dhw_disinfecttime | 6 | 9 | 15 | 9 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | dailyheating | daily heating | boolean | | True | switch.thermostat_dhw_daily_heating | switch.thermostat_dhw_dailyheating | 6 | 9 | 1 | 10 | 1 |
RC200, CW100, CR120, CR50 | thermostat | 157 | dailyheattime | daily heating time | uint8 (>=0<=1431) | minutes | True | number.thermostat_dhw_daily_heating_time | number.thermostat_dhw_dailyheattime | 6 | 9 | 15 | 11 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | errorcode | error code | string | | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | 6 | 0 | 1 | 0 | 8 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | lastcode | last error code | string | | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | 6 | 0 | 1 | 8 | 25 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | datetime | date/time | string | | True | sensor.thermostat_date/time | sensor.thermostat_datetime | 6 | 0 | 1 | 33 | 13 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | intoffset | internal temperature offset | int8 (>=-12<=12) | C | True | number.thermostat_internal_temperature_offset | number.thermostat_intoffset | 6 | 0 | 1/10 | 46 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | floordry | floor drying | enum [off|start|heat|hold|cool|end] | | False | sensor.thermostat_floor_drying | sensor.thermostat_floordry | 6 | 0 | 1 | 47 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | dampedoutdoortemp | damped outdoor temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_damped_outdoor_temperature | sensor.thermostat_dampedoutdoortemp | 6 | 0 | 1/10 | 48 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | floordrytemp | floor drying temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_floor_drying_temperature | sensor.thermostat_floordrytemp | 6 | 0 | 1 | 49 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | building | building type | enum [light|medium|heavy] | | True | select.thermostat_building_type | select.thermostat_building | 6 | 0 | 1 | 50 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | minexttemp | minimal external temperature | int8 (>=-126<=126) | C | True | number.thermostat_minimal_external_temperature | number.thermostat_minexttemp | 6 | 0 | 1 | 51 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | damping | damping outdoor temperature | boolean | | True | switch.thermostat_damping_outdoor_temperature | switch.thermostat_damping | 6 | 0 | 1 | 52 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | hybridstrategy | hybrid control strategy | enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] | | True | select.thermostat_hybrid_control_strategy | select.thermostat_hybridstrategy | 6 | 0 | 1 | 53 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | switchovertemp | outside switchover temperature | int8 (>=-20<=20) | C | True | number.thermostat_outside_switchover_temperature | number.thermostat_switchovertemp | 6 | 0 | 1 | 54 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | energycostratio | energy cost ratio | uint8 (>=0<=20) | | True | number.thermostat_energy_cost_ratio | number.thermostat_energycostratio | 6 | 0 | 1/10 | 55 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | fossilefactor | fossile energy factor | uint8 (>=0<=5) | | True | number.thermostat_fossile_energy_factor | number.thermostat_fossilefactor | 6 | 0 | 1/10 | 56 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | electricfactor | electric energy factor | uint8 (>=0<=5) | | True | number.thermostat_electric_energy_factor | number.thermostat_electricfactor | 6 | 0 | 1/10 | 57 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | delayboiler | delay boiler support | uint8 (>=5<=120) | minutes | True | number.thermostat_delay_boiler_support | number.thermostat_delayboiler | 6 | 0 | 1 | 58 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | tempdiffboiler | temp diff boiler support | uint8 (>=1<=99) | C | True | number.thermostat_temp_diff_boiler_support | number.thermostat_tempdiffboiler | 6 | 0 | 1 | 59 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | pvenabledhw | enable raise dhw | boolean | | True | switch.thermostat_enable_raise_dhw | switch.thermostat_pvenabledhw | 6 | 0 | 1 | 60 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | pvraiseheat | raise heating with PV | int8 (>=0<=5) | K | True | number.thermostat_raise_heating_with_PV | number.thermostat_pvraiseheat | 6 | 0 | 1 | 61 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | pvlowercool | lower cooling with PV | int8 (>=-5<=0) | K | True | number.thermostat_lower_cooling_with_PV | number.thermostat_pvlowercool | 6 | 0 | 1 | 62 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp | 6 | 1 | 1/2 | 0 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp | 6 | 1 | 1/10 | 1 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | 6 | 1 | 1 | 2 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | mode | operating mode | enum [manual|auto] | | True | select.thermostat_hc1_operating_mode | select.thermostat_hc1_mode | 6 | 1 | 1 | 3 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | modetype | mode type | enum [eco|comfort] | | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | 6 | 1 | 1 | 4 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | ecotemp | eco temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_eco_temperature | number.thermostat_hc1_ecotemp | 6 | 1 | 1/2 | 5 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | manualtemp | manual temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_manual_temperature | number.thermostat_hc1_manualtemp | 6 | 1 | 1/2 | 6 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | comforttemp | comfort temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_comfort_temperature | number.thermostat_hc1_comforttemp | 6 | 1 | 1/2 | 7 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | summertemp | summer temperature | uint8 (>=10<=30) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp | 6 | 1 | 1 | 8 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | designtemp | design temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp | 6 | 1 | 1 | 9 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | offsettemp | offset temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_offset_temperature | number.thermostat_hc1_offsettemp | 6 | 1 | 1 | 10 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | minflowtemp | min flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp | 6 | 1 | 1 | 11 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | maxflowtemp | max flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp | 6 | 1 | 1 | 12 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | roominfluence | room influence | uint8 (>=0<=254) | C | True | number.thermostat_hc1_room_influence | number.thermostat_hc1_roominfluence | 6 | 1 | 1 | 13 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | roominflfactor | room influence factor | uint8 (>=0<=25) | | True | number.thermostat_hc1_room_influence_factor | number.thermostat_hc1_roominflfactor | 6 | 1 | 1/10 | 14 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | curroominfl | current room influence | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_influence | sensor.thermostat_hc1_curroominfl | 6 | 1 | 1/10 | 15 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | nofrostmode | nofrost mode | enum [room|outdoor|room outdoor] | | True | select.thermostat_hc1_nofrost_mode | select.thermostat_hc1_nofrostmode | 6 | 1 | 1 | 16 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | nofrosttemp | nofrost temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp | 6 | 1 | 1 | 17 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp | 6 | 1 | 1 | 18 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | heatingtype | heating type | enum [off|radiator|convector|floor] | | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | 6 | 1 | 1 | 19 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | summersetmode | set summer mode | enum [summer|auto|winter] | | True | select.thermostat_hc1_set_summer_mode | select.thermostat_hc1_summersetmode | 6 | 1 | 1 | 20 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | hpoperatingmode | heatpump operating mode | enum [off|auto|heating|cooling] | | True | select.thermostat_hc1_heatpump_operating_mode | select.thermostat_hc1_hpoperatingmode | 6 | 1 | 1 | 21 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | summermode | summer mode | enum [winter|summer] | | False | sensor.thermostat_hc1_summer_mode | sensor.thermostat_hc1_summermode | 6 | 1 | 1 | 22 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | hpoperatingstate | heatpump operating state | enum [heating|off|cooling] | | False | sensor.thermostat_hc1_heatpump_operating_state | sensor.thermostat_hc1_hpoperatingstate | 6 | 1 | 1 | 23 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | controlmode | control mode | enum [weather compensated|outside basepoint|n/a|room|power|constant] | | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | 6 | 1 | 1 | 24 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | program | program | enum [prog 1|prog 2] | | True | select.thermostat_hc1_program | select.thermostat_hc1_program | 6 | 1 | 1 | 25 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | tempautotemp | temporary set temperature automode | int8 (>=-1<=30) | C | True | number.thermostat_hc1_temporary_set_temperature_automode | number.thermostat_hc1_tempautotemp | 6 | 1 | 1/2 | 26 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | remoteseltemp | temporary set temperature from remote | int8 (>=-1<=30) | C | True | number.thermostat_hc1_temporary_set_temperature_from_remote | number.thermostat_hc1_remoteseltemp | 6 | 1 | 1/2 | 27 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | fastheatup | fast heatup | uint8 (>=0<=100) | % | True | number.thermostat_hc1_fast_heatup | number.thermostat_hc1_fastheatup | 6 | 1 | 1 | 28 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | switchonoptimization | switch-on optimization | boolean | | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | 6 | 1 | 1 | 29 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | reducemode | reduce mode | enum [outdoor|room|reduce] | | True | select.thermostat_hc1_reduce_mode | select.thermostat_hc1_reducemode | 6 | 1 | 1 | 30 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | noreducetemp | no reduce below temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_no_reduce_below_temperature | number.thermostat_hc1_noreducetemp | 6 | 1 | 1 | 31 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | reducetemp | off/reduce switch temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_off/reduce_switch_temperature | number.thermostat_hc1_reducetemp | 6 | 1 | 1 | 32 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | dhwprio | dhw priority | boolean | | True | switch.thermostat_hc1_dhw_priority | switch.thermostat_hc1_dhwprio | 6 | 1 | 1 | 33 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | hpcooling | hp cooling | boolean | | True | switch.thermostat_hc1_hp_cooling | switch.thermostat_hc1_hpcooling | 6 | 1 | 1 | 34 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | coolingon | cooling on | boolean | | False | binary_sensor.thermostat_hc1_cooling_on | binary_sensor.thermostat_hc1_coolingon | 6 | 1 | 1 | 35 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | hpmode | HP Mode | enum [heating|cooling|heating & cooling] | | True | select.thermostat_hc1_HP_Mode | select.thermostat_hc1_hpmode | 6 | 1 | 1 | 36 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | dewoffset | dew point offset | uint8 (>=2<=10) | K | True | number.thermostat_hc1_dew_point_offset | number.thermostat_hc1_dewoffset | 6 | 1 | 1 | 37 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | roomtempdiff | room temp difference | uint8 (>=0<=254) | K | True | number.thermostat_hc1_room_temp_difference | number.thermostat_hc1_roomtempdiff | 6 | 1 | 1 | 38 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | hpminflowtemp | HP min. flow temp. | uint8 (>=0<=254) | C | True | number.thermostat_hc1_HP_min._flow_temp. | number.thermostat_hc1_hpminflowtemp | 6 | 1 | 1 | 39 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | control | control device | enum [RC310|RC200|RC100|RC100H|TC100] | | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | 6 | 1 | 1 | 40 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | remotetemp | room temperature from remote | cmd [] (>=-1<=101) | C | True | sensor.thermostat_hc1_room_temperature_from_remote | sensor.thermostat_hc1_remotetemp | 6 | 1 | 1/10 | 41 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | remotehum | room humidity from remote | cmd [] (>=-1<=101) | % | True | sensor.thermostat_hc1_room_humidity_from_remote | sensor.thermostat_hc1_remotehum | 6 | 1 | 1 | 42 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | heatondelay | heat-on delay | uint8 (>=1<=48) | hours | True | number.thermostat_hc1_heat-on_delay | number.thermostat_hc1_heatondelay | 6 | 1 | 1 | 43 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | heatoffdelay | heat-off delay | uint8 (>=1<=48) | hours | True | number.thermostat_hc1_heat-off_delay | number.thermostat_hc1_heatoffdelay | 6 | 1 | 1 | 44 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | instantstart | instant start | uint8 (>=1<=10) | K | True | number.thermostat_hc1_instant_start | number.thermostat_hc1_instantstart | 6 | 1 | 1 | 45 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | boost | boost mode | boolean | | True | switch.thermostat_hc1_boost_mode | switch.thermostat_hc1_boost | 6 | 1 | 1 | 46 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | boosttime | boost time | uint8 (>=0<=254) | hours | True | number.thermostat_hc1_boost_time | number.thermostat_hc1_boosttime | 6 | 1 | 1 | 47 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | coolstart | cooling starttemp | uint8 (>=20<=35) | C | True | number.thermostat_hc1_cooling_starttemp | number.thermostat_hc1_coolstart | 6 | 1 | 1 | 48 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | coolondelay | cooling on delay | uint8 (>=1<=48) | hours | True | number.thermostat_hc1_cooling_on_delay | number.thermostat_hc1_coolondelay | 6 | 1 | 1 | 49 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | cooloffdelay | cooling off delay | uint8 (>=1<=48) | hours | True | number.thermostat_hc1_cooling_off_delay | number.thermostat_hc1_cooloffdelay | 6 | 1 | 1 | 50 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | switchprogmode | switch program mode | enum [level|absolute] | | True | select.thermostat_hc1_switch_program_mode | select.thermostat_hc1_switchprogmode | 6 | 1 | 1 | 51 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | mode | operating mode | enum [off|normal|comfort|auto|own prog] | | True | select.thermostat_dhw_operating_mode | select.thermostat_dhw_mode | 6 | 9 | 1 | 0 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | settemp | set temperature | uint8 (>=0<=254) | C | True | number.thermostat_dhw_set_temperature | number.thermostat_dhw_settemp | 6 | 9 | 1 | 1 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | settemplow | set low temperature | uint8 (>=0<=254) | C | True | number.thermostat_dhw_set_low_temperature | number.thermostat_dhw_settemplow | 6 | 9 | 1 | 2 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | circmode | circulation pump mode | enum [off|on|auto|own prog] | | True | select.thermostat_dhw_circulation_pump_mode | select.thermostat_dhw_circmode | 6 | 9 | 1 | 3 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | chargeduration | charge duration | uint8 (>=0<=3810) | minutes | True | number.thermostat_dhw_charge_duration | number.thermostat_dhw_chargeduration | 6 | 9 | 15 | 4 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | charge | charge | boolean | | True | switch.thermostat_dhw_charge | switch.thermostat_dhw_charge | 6 | 9 | 1 | 5 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | extra | extra | uint8 (>=0<=254) | C | False | sensor.thermostat_dhw_extra | sensor.thermostat_dhw_extra | 6 | 9 | 1 | 6 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | disinfecting | disinfecting | boolean | | True | switch.thermostat_dhw_disinfecting | switch.thermostat_dhw_disinfecting | 6 | 9 | 1 | 7 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | disinfectday | disinfection day | enum [mo|tu|we|th|fr|sa|su|all] | | True | select.thermostat_dhw_disinfection_day | select.thermostat_dhw_disinfectday | 6 | 9 | 1 | 8 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | disinfecttime | disinfection time | uint8 (>=0<=1431) | minutes | True | number.thermostat_dhw_disinfection_time | number.thermostat_dhw_disinfecttime | 6 | 9 | 15 | 9 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | dailyheating | daily heating | boolean | | True | switch.thermostat_dhw_daily_heating | switch.thermostat_dhw_dailyheating | 6 | 9 | 1 | 10 | 1 |
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 | thermostat | 158 | dailyheattime | daily heating time | uint8 (>=0<=1431) | minutes | True | number.thermostat_dhw_daily_heating_time | number.thermostat_dhw_dailyheattime | 6 | 9 | 15 | 11 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | errorcode | error code | string | | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | 6 | 0 | 1 | 0 | 8 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | lastcode | last error code | string | | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | 6 | 0 | 1 | 8 | 25 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | datetime | date/time | string | | True | sensor.thermostat_date/time | sensor.thermostat_datetime | 6 | 0 | 1 | 33 | 13 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | intoffset | internal temperature offset | int8 (>=-12<=12) | C | True | number.thermostat_internal_temperature_offset | number.thermostat_intoffset | 6 | 0 | 1/10 | 46 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | floordry | floor drying | enum [off|start|heat|hold|cool|end] | | False | sensor.thermostat_floor_drying | sensor.thermostat_floordry | 6 | 0 | 1 | 47 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | dampedoutdoortemp | damped outdoor temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_damped_outdoor_temperature | sensor.thermostat_dampedoutdoortemp | 6 | 0 | 1/10 | 48 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | floordrytemp | floor drying temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_floor_drying_temperature | sensor.thermostat_floordrytemp | 6 | 0 | 1 | 49 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | building | building type | enum [light|medium|heavy] | | True | select.thermostat_building_type | select.thermostat_building | 6 | 0 | 1 | 50 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | minexttemp | minimal external temperature | int8 (>=-126<=126) | C | True | number.thermostat_minimal_external_temperature | number.thermostat_minexttemp | 6 | 0 | 1 | 51 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | damping | damping outdoor temperature | boolean | | True | switch.thermostat_damping_outdoor_temperature | switch.thermostat_damping | 6 | 0 | 1 | 52 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | hybridstrategy | hybrid control strategy | enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] | | True | select.thermostat_hybrid_control_strategy | select.thermostat_hybridstrategy | 6 | 0 | 1 | 53 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | switchovertemp | outside switchover temperature | int8 (>=-20<=20) | C | True | number.thermostat_outside_switchover_temperature | number.thermostat_switchovertemp | 6 | 0 | 1 | 54 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | energycostratio | energy cost ratio | uint8 (>=0<=20) | | True | number.thermostat_energy_cost_ratio | number.thermostat_energycostratio | 6 | 0 | 1/10 | 55 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | fossilefactor | fossile energy factor | uint8 (>=0<=5) | | True | number.thermostat_fossile_energy_factor | number.thermostat_fossilefactor | 6 | 0 | 1/10 | 56 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | electricfactor | electric energy factor | uint8 (>=0<=5) | | True | number.thermostat_electric_energy_factor | number.thermostat_electricfactor | 6 | 0 | 1/10 | 57 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | delayboiler | delay boiler support | uint8 (>=5<=120) | minutes | True | number.thermostat_delay_boiler_support | number.thermostat_delayboiler | 6 | 0 | 1 | 58 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | tempdiffboiler | temp diff boiler support | uint8 (>=1<=99) | C | True | number.thermostat_temp_diff_boiler_support | number.thermostat_tempdiffboiler | 6 | 0 | 1 | 59 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | pvenabledhw | enable raise dhw | boolean | | True | switch.thermostat_enable_raise_dhw | switch.thermostat_pvenabledhw | 6 | 0 | 1 | 60 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | pvraiseheat | raise heating with PV | int8 (>=0<=5) | K | True | number.thermostat_raise_heating_with_PV | number.thermostat_pvraiseheat | 6 | 0 | 1 | 61 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | pvlowercool | lower cooling with PV | int8 (>=-5<=0) | K | True | number.thermostat_lower_cooling_with_PV | number.thermostat_pvlowercool | 6 | 0 | 1 | 62 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp | 6 | 1 | 1/2 | 0 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp | 6 | 1 | 1/10 | 1 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | 6 | 1 | 1 | 2 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | mode | operating mode | enum [manual|auto] | | True | select.thermostat_hc1_operating_mode | select.thermostat_hc1_mode | 6 | 1 | 1 | 3 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | modetype | mode type | enum [eco|comfort] | | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | 6 | 1 | 1 | 4 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | ecotemp | eco temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_eco_temperature | number.thermostat_hc1_ecotemp | 6 | 1 | 1/2 | 5 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | manualtemp | manual temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_manual_temperature | number.thermostat_hc1_manualtemp | 6 | 1 | 1/2 | 6 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | comforttemp | comfort temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_comfort_temperature | number.thermostat_hc1_comforttemp | 6 | 1 | 1/2 | 7 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | summertemp | summer temperature | uint8 (>=10<=30) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp | 6 | 1 | 1 | 8 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | designtemp | design temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp | 6 | 1 | 1 | 9 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | offsettemp | offset temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_offset_temperature | number.thermostat_hc1_offsettemp | 6 | 1 | 1 | 10 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | minflowtemp | min flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp | 6 | 1 | 1 | 11 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | maxflowtemp | max flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp | 6 | 1 | 1 | 12 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | roominfluence | room influence | uint8 (>=0<=254) | C | True | number.thermostat_hc1_room_influence | number.thermostat_hc1_roominfluence | 6 | 1 | 1 | 13 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | roominflfactor | room influence factor | uint8 (>=0<=25) | | True | number.thermostat_hc1_room_influence_factor | number.thermostat_hc1_roominflfactor | 6 | 1 | 1/10 | 14 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | curroominfl | current room influence | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_influence | sensor.thermostat_hc1_curroominfl | 6 | 1 | 1/10 | 15 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | nofrostmode | nofrost mode | enum [room|outdoor|room outdoor] | | True | select.thermostat_hc1_nofrost_mode | select.thermostat_hc1_nofrostmode | 6 | 1 | 1 | 16 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | nofrosttemp | nofrost temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp | 6 | 1 | 1 | 17 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp | 6 | 1 | 1 | 18 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | heatingtype | heating type | enum [off|radiator|convector|floor] | | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | 6 | 1 | 1 | 19 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | summersetmode | set summer mode | enum [summer|auto|winter] | | True | select.thermostat_hc1_set_summer_mode | select.thermostat_hc1_summersetmode | 6 | 1 | 1 | 20 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | hpoperatingmode | heatpump operating mode | enum [off|auto|heating|cooling] | | True | select.thermostat_hc1_heatpump_operating_mode | select.thermostat_hc1_hpoperatingmode | 6 | 1 | 1 | 21 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | summermode | summer mode | enum [winter|summer] | | False | sensor.thermostat_hc1_summer_mode | sensor.thermostat_hc1_summermode | 6 | 1 | 1 | 22 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | hpoperatingstate | heatpump operating state | enum [heating|off|cooling] | | False | sensor.thermostat_hc1_heatpump_operating_state | sensor.thermostat_hc1_hpoperatingstate | 6 | 1 | 1 | 23 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | controlmode | control mode | enum [optimized|simple|n/a|room|power] | | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | 6 | 1 | 1 | 24 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | program | program | enum [prog 1|prog 2] | | True | select.thermostat_hc1_program | select.thermostat_hc1_program | 6 | 1 | 1 | 25 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | tempautotemp | temporary set temperature automode | int8 (>=-1<=30) | C | True | number.thermostat_hc1_temporary_set_temperature_automode | number.thermostat_hc1_tempautotemp | 6 | 1 | 1/2 | 26 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | remoteseltemp | temporary set temperature from remote | int8 (>=-1<=30) | C | True | number.thermostat_hc1_temporary_set_temperature_from_remote | number.thermostat_hc1_remoteseltemp | 6 | 1 | 1/2 | 27 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | fastheatup | fast heatup | uint8 (>=0<=100) | % | True | number.thermostat_hc1_fast_heatup | number.thermostat_hc1_fastheatup | 6 | 1 | 1 | 28 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | switchonoptimization | switch-on optimization | boolean | | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | 6 | 1 | 1 | 29 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | reducemode | reduce mode | enum [outdoor|room|reduce] | | True | select.thermostat_hc1_reduce_mode | select.thermostat_hc1_reducemode | 6 | 1 | 1 | 30 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | noreducetemp | no reduce below temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_no_reduce_below_temperature | number.thermostat_hc1_noreducetemp | 6 | 1 | 1 | 31 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | reducetemp | off/reduce switch temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_off/reduce_switch_temperature | number.thermostat_hc1_reducetemp | 6 | 1 | 1 | 32 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | dhwprio | dhw priority | boolean | | True | switch.thermostat_hc1_dhw_priority | switch.thermostat_hc1_dhwprio | 6 | 1 | 1 | 33 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | hpcooling | hp cooling | boolean | | True | switch.thermostat_hc1_hp_cooling | switch.thermostat_hc1_hpcooling | 6 | 1 | 1 | 34 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | coolingon | cooling on | boolean | | False | binary_sensor.thermostat_hc1_cooling_on | binary_sensor.thermostat_hc1_coolingon | 6 | 1 | 1 | 35 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | hpmode | HP Mode | enum [heating|cooling|heating & cooling] | | True | select.thermostat_hc1_HP_Mode | select.thermostat_hc1_hpmode | 6 | 1 | 1 | 36 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | dewoffset | dew point offset | uint8 (>=2<=10) | K | True | number.thermostat_hc1_dew_point_offset | number.thermostat_hc1_dewoffset | 6 | 1 | 1 | 37 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | roomtempdiff | room temp difference | uint8 (>=0<=254) | K | True | number.thermostat_hc1_room_temp_difference | number.thermostat_hc1_roomtempdiff | 6 | 1 | 1 | 38 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | hpminflowtemp | HP min. flow temp. | uint8 (>=0<=254) | C | True | number.thermostat_hc1_HP_min._flow_temp. | number.thermostat_hc1_hpminflowtemp | 6 | 1 | 1 | 39 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | control | control device | enum [RC310|RC200|RC100|RC100H|TC100] | | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | 6 | 1 | 1 | 40 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | remotetemp | room temperature from remote | cmd [] (>=-1<=101) | C | True | sensor.thermostat_hc1_room_temperature_from_remote | sensor.thermostat_hc1_remotetemp | 6 | 1 | 1/10 | 41 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | remotehum | room humidity from remote | cmd [] (>=-1<=101) | % | True | sensor.thermostat_hc1_room_humidity_from_remote | sensor.thermostat_hc1_remotehum | 6 | 1 | 1 | 42 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | heatondelay | heat-on delay | uint8 (>=1<=48) | hours | True | number.thermostat_hc1_heat-on_delay | number.thermostat_hc1_heatondelay | 6 | 1 | 1 | 43 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | heatoffdelay | heat-off delay | uint8 (>=1<=48) | hours | True | number.thermostat_hc1_heat-off_delay | number.thermostat_hc1_heatoffdelay | 6 | 1 | 1 | 44 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | instantstart | instant start | uint8 (>=1<=10) | K | True | number.thermostat_hc1_instant_start | number.thermostat_hc1_instantstart | 6 | 1 | 1 | 45 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | boost | boost mode | boolean | | True | switch.thermostat_hc1_boost_mode | switch.thermostat_hc1_boost | 6 | 1 | 1 | 46 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | boosttime | boost time | uint8 (>=0<=254) | hours | True | number.thermostat_hc1_boost_time | number.thermostat_hc1_boosttime | 6 | 1 | 1 | 47 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | coolstart | cooling starttemp | uint8 (>=20<=35) | C | True | number.thermostat_hc1_cooling_starttemp | number.thermostat_hc1_coolstart | 6 | 1 | 1 | 48 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | coolondelay | cooling on delay | uint8 (>=1<=48) | hours | True | number.thermostat_hc1_cooling_on_delay | number.thermostat_hc1_coolondelay | 6 | 1 | 1 | 49 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | cooloffdelay | cooling off delay | uint8 (>=1<=48) | hours | True | number.thermostat_hc1_cooling_off_delay | number.thermostat_hc1_cooloffdelay | 6 | 1 | 1 | 50 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | switchprogmode | switch program mode | enum [level|absolute] | | True | select.thermostat_hc1_switch_program_mode | select.thermostat_hc1_switchprogmode | 6 | 1 | 1 | 51 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | mode | operating mode | enum [off|normal|comfort|auto|own prog] | | True | select.thermostat_dhw_operating_mode | select.thermostat_dhw_mode | 6 | 9 | 1 | 0 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | settemp | set temperature | uint8 (>=0<=254) | C | True | number.thermostat_dhw_set_temperature | number.thermostat_dhw_settemp | 6 | 9 | 1 | 1 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | settemplow | set low temperature | uint8 (>=0<=254) | C | True | number.thermostat_dhw_set_low_temperature | number.thermostat_dhw_settemplow | 6 | 9 | 1 | 2 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | circmode | circulation pump mode | enum [off|on|auto|own prog] | | True | select.thermostat_dhw_circulation_pump_mode | select.thermostat_dhw_circmode | 6 | 9 | 1 | 3 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | chargeduration | charge duration | uint8 (>=0<=3810) | minutes | True | number.thermostat_dhw_charge_duration | number.thermostat_dhw_chargeduration | 6 | 9 | 15 | 4 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | charge | charge | boolean | | True | switch.thermostat_dhw_charge | switch.thermostat_dhw_charge | 6 | 9 | 1 | 5 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | extra | extra | uint8 (>=0<=254) | C | False | sensor.thermostat_dhw_extra | sensor.thermostat_dhw_extra | 6 | 9 | 1 | 6 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | disinfecting | disinfecting | boolean | | True | switch.thermostat_dhw_disinfecting | switch.thermostat_dhw_disinfecting | 6 | 9 | 1 | 7 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | disinfectday | disinfection day | enum [mo|tu|we|th|fr|sa|su|all] | | True | select.thermostat_dhw_disinfection_day | select.thermostat_dhw_disinfectday | 6 | 9 | 1 | 8 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | disinfecttime | disinfection time | uint8 (>=0<=1431) | minutes | True | number.thermostat_dhw_disinfection_time | number.thermostat_dhw_disinfecttime | 6 | 9 | 15 | 9 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | dailyheating | daily heating | boolean | | True | switch.thermostat_dhw_daily_heating | switch.thermostat_dhw_dailyheating | 6 | 9 | 1 | 10 | 1 |
RC100, CR10, Moduline 1000/1010 | thermostat | 165 | dailyheattime | daily heating time | uint8 (>=0<=1431) | minutes | True | number.thermostat_dhw_daily_heating_time | number.thermostat_dhw_dailyheattime | 6 | 9 | 15 | 11 | 1 |
Rego 2000/3000 | thermostat | 172 | errorcode | error code | string | | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | 6 | 0 | 1 | 0 | 8 |
Rego 2000/3000 | thermostat | 172 | lastcode | last error code | string | | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | 6 | 0 | 1 | 8 | 25 |
Rego 2000/3000 | thermostat | 172 | datetime | date/time | string | | True | sensor.thermostat_date/time | sensor.thermostat_datetime | 6 | 0 | 1 | 33 | 13 |
Rego 2000/3000 | thermostat | 172 | intoffset | internal temperature offset | int8 (>=-12<=12) | C | True | number.thermostat_internal_temperature_offset | number.thermostat_intoffset | 6 | 0 | 1/10 | 46 | 1 |
Rego 2000/3000 | thermostat | 172 | floordry | floor drying | enum [off|start|heat|hold|cool|end] | | False | sensor.thermostat_floor_drying | sensor.thermostat_floordry | 6 | 0 | 1 | 47 | 1 |
Rego 2000/3000 | thermostat | 172 | dampedoutdoortemp | damped outdoor temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_damped_outdoor_temperature | sensor.thermostat_dampedoutdoortemp | 6 | 0 | 1/10 | 48 | 1 |
Rego 2000/3000 | thermostat | 172 | floordrytemp | floor drying temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_floor_drying_temperature | sensor.thermostat_floordrytemp | 6 | 0 | 1 | 49 | 1 |
Rego 2000/3000 | thermostat | 172 | building | building type | enum [light|medium|heavy] | | True | select.thermostat_building_type | select.thermostat_building | 6 | 0 | 1 | 50 | 1 |
Rego 2000/3000 | thermostat | 172 | minexttemp | minimal external temperature | int8 (>=-126<=126) | C | True | number.thermostat_minimal_external_temperature | number.thermostat_minexttemp | 6 | 0 | 1 | 51 | 1 |
Rego 2000/3000 | thermostat | 172 | damping | damping outdoor temperature | boolean | | True | switch.thermostat_damping_outdoor_temperature | switch.thermostat_damping | 6 | 0 | 1 | 52 | 1 |
Rego 2000/3000 | thermostat | 172 | vacations | vacation dates | string | | True | sensor.thermostat_vacation_dates | sensor.thermostat_vacations | 6 | 0 | 1 | 74 | 13 |
Rego 2000/3000 | thermostat | 172 | hybridstrategy | hybrid control strategy | enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] | | True | select.thermostat_hybrid_control_strategy | select.thermostat_hybridstrategy | 6 | 0 | 1 | 53 | 1 |
Rego 2000/3000 | thermostat | 172 | switchovertemp | outside switchover temperature | int8 (>=-20<=20) | C | True | number.thermostat_outside_switchover_temperature | number.thermostat_switchovertemp | 6 | 0 | 1 | 54 | 1 |
Rego 2000/3000 | thermostat | 172 | energycostratio | energy cost ratio | uint8 (>=0<=20) | | True | number.thermostat_energy_cost_ratio | number.thermostat_energycostratio | 6 | 0 | 1/10 | 55 | 1 |
Rego 2000/3000 | thermostat | 172 | fossilefactor | fossile energy factor | uint8 (>=0<=5) | | True | number.thermostat_fossile_energy_factor | number.thermostat_fossilefactor | 6 | 0 | 1/10 | 56 | 1 |
Rego 2000/3000 | thermostat | 172 | electricfactor | electric energy factor | uint8 (>=0<=5) | | True | number.thermostat_electric_energy_factor | number.thermostat_electricfactor | 6 | 0 | 1/10 | 57 | 1 |
Rego 2000/3000 | thermostat | 172 | delayboiler | delay boiler support | uint8 (>=5<=120) | minutes | True | number.thermostat_delay_boiler_support | number.thermostat_delayboiler | 6 | 0 | 1 | 58 | 1 |
Rego 2000/3000 | thermostat | 172 | tempdiffboiler | temp diff boiler support | uint8 (>=1<=99) | C | True | number.thermostat_temp_diff_boiler_support | number.thermostat_tempdiffboiler | 6 | 0 | 1 | 59 | 1 |
Rego 2000/3000 | thermostat | 172 | pvenabledhw | enable raise dhw | boolean | | True | switch.thermostat_enable_raise_dhw | switch.thermostat_pvenabledhw | 6 | 0 | 1 | 60 | 1 |
Rego 2000/3000 | thermostat | 172 | pvraiseheat | raise heating with PV | int8 (>=0<=5) | K | True | number.thermostat_raise_heating_with_PV | number.thermostat_pvraiseheat | 6 | 0 | 1 | 61 | 1 |
Rego 2000/3000 | thermostat | 172 | pvlowercool | lower cooling with PV | int8 (>=-5<=0) | K | True | number.thermostat_lower_cooling_with_PV | number.thermostat_pvlowercool | 6 | 0 | 1 | 62 | 1 |
Rego 2000/3000 | thermostat | 172 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp | 6 | 1 | 1/2 | 0 | 1 |
Rego 2000/3000 | thermostat | 172 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp | 6 | 1 | 1/10 | 1 | 1 |
Rego 2000/3000 | thermostat | 172 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | 6 | 1 | 1 | 2 | 1 |
Rego 2000/3000 | thermostat | 172 | mode | operating mode | enum [manual|auto] | | True | select.thermostat_hc1_operating_mode | select.thermostat_hc1_mode | 6 | 1 | 1 | 3 | 1 |
Rego 2000/3000 | thermostat | 172 | modetype | mode type | enum [eco|comfort] | | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | 6 | 1 | 1 | 4 | 1 |
Rego 2000/3000 | thermostat | 172 | ecotemp | eco temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_eco_temperature | number.thermostat_hc1_ecotemp | 6 | 1 | 1/2 | 5 | 1 |
Rego 2000/3000 | thermostat | 172 | manualtemp | manual temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_manual_temperature | number.thermostat_hc1_manualtemp | 6 | 1 | 1/2 | 6 | 1 |
Rego 2000/3000 | thermostat | 172 | comforttemp | comfort temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_comfort_temperature | number.thermostat_hc1_comforttemp | 6 | 1 | 1/2 | 7 | 1 |
Rego 2000/3000 | thermostat | 172 | summertemp | summer temperature | uint8 (>=10<=30) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp | 6 | 1 | 1 | 8 | 1 |
Rego 2000/3000 | thermostat | 172 | designtemp | design temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp | 6 | 1 | 1 | 9 | 1 |
Rego 2000/3000 | thermostat | 172 | offsettemp | offset temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_offset_temperature | number.thermostat_hc1_offsettemp | 6 | 1 | 1 | 10 | 1 |
Rego 2000/3000 | thermostat | 172 | minflowtemp | min flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp | 6 | 1 | 1 | 11 | 1 |
Rego 2000/3000 | thermostat | 172 | maxflowtemp | max flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp | 6 | 1 | 1 | 12 | 1 |
Rego 2000/3000 | thermostat | 172 | roominfluence | room influence | uint8 (>=0<=254) | C | True | number.thermostat_hc1_room_influence | number.thermostat_hc1_roominfluence | 6 | 1 | 1 | 13 | 1 |
Rego 2000/3000 | thermostat | 172 | roominflfactor | room influence factor | uint8 (>=0<=25) | | True | number.thermostat_hc1_room_influence_factor | number.thermostat_hc1_roominflfactor | 6 | 1 | 1/10 | 14 | 1 |
Rego 2000/3000 | thermostat | 172 | curroominfl | current room influence | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_influence | sensor.thermostat_hc1_curroominfl | 6 | 1 | 1/10 | 15 | 1 |
Rego 2000/3000 | thermostat | 172 | nofrostmode | nofrost mode | enum [room|outdoor|room outdoor] | | True | select.thermostat_hc1_nofrost_mode | select.thermostat_hc1_nofrostmode | 6 | 1 | 1 | 16 | 1 |
Rego 2000/3000 | thermostat | 172 | nofrosttemp | nofrost temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp | 6 | 1 | 1 | 17 | 1 |
Rego 2000/3000 | thermostat | 172 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp | 6 | 1 | 1 | 18 | 1 |
Rego 2000/3000 | thermostat | 172 | heatingtype | heating type | enum [off|radiator|convector|floor] | | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | 6 | 1 | 1 | 19 | 1 |
Rego 2000/3000 | thermostat | 172 | summersetmode | set summer mode | enum [summer|auto|winter] | | True | select.thermostat_hc1_set_summer_mode | select.thermostat_hc1_summersetmode | 6 | 1 | 1 | 20 | 1 |
Rego 2000/3000 | thermostat | 172 | hpoperatingmode | heatpump operating mode | enum [off|auto|heating|cooling] | | True | select.thermostat_hc1_heatpump_operating_mode | select.thermostat_hc1_hpoperatingmode | 6 | 1 | 1 | 21 | 1 |
Rego 2000/3000 | thermostat | 172 | summermode | summer mode | enum [winter|summer] | | False | sensor.thermostat_hc1_summer_mode | sensor.thermostat_hc1_summermode | 6 | 1 | 1 | 22 | 1 |
Rego 2000/3000 | thermostat | 172 | hpoperatingstate | heatpump operating state | enum [heating|off|cooling] | | False | sensor.thermostat_hc1_heatpump_operating_state | sensor.thermostat_hc1_hpoperatingstate | 6 | 1 | 1 | 23 | 1 |
Rego 2000/3000 | thermostat | 172 | controlmode | control mode | enum [weather compensated|outside basepoint|n/a|room|power|constant] | | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | 6 | 1 | 1 | 24 | 1 |
Rego 2000/3000 | thermostat | 172 | program | program | enum [prog 1|prog 2] | | True | select.thermostat_hc1_program | select.thermostat_hc1_program | 6 | 1 | 1 | 25 | 1 |
Rego 2000/3000 | thermostat | 172 | tempautotemp | temporary set temperature automode | int8 (>=-1<=30) | C | True | number.thermostat_hc1_temporary_set_temperature_automode | number.thermostat_hc1_tempautotemp | 6 | 1 | 1/2 | 26 | 1 |
Rego 2000/3000 | thermostat | 172 | remoteseltemp | temporary set temperature from remote | int8 (>=-1<=30) | C | True | number.thermostat_hc1_temporary_set_temperature_from_remote | number.thermostat_hc1_remoteseltemp | 6 | 1 | 1/2 | 27 | 1 |
Rego 2000/3000 | thermostat | 172 | fastheatup | fast heatup | uint8 (>=0<=100) | % | True | number.thermostat_hc1_fast_heatup | number.thermostat_hc1_fastheatup | 6 | 1 | 1 | 28 | 1 |
Rego 2000/3000 | thermostat | 172 | switchonoptimization | switch-on optimization | boolean | | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | 6 | 1 | 1 | 29 | 1 |
Rego 2000/3000 | thermostat | 172 | reducemode | reduce mode | enum [outdoor|room|reduce] | | True | select.thermostat_hc1_reduce_mode | select.thermostat_hc1_reducemode | 6 | 1 | 1 | 30 | 1 |
Rego 2000/3000 | thermostat | 172 | noreducetemp | no reduce below temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_no_reduce_below_temperature | number.thermostat_hc1_noreducetemp | 6 | 1 | 1 | 31 | 1 |
Rego 2000/3000 | thermostat | 172 | reducetemp | off/reduce switch temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_off/reduce_switch_temperature | number.thermostat_hc1_reducetemp | 6 | 1 | 1 | 32 | 1 |
Rego 2000/3000 | thermostat | 172 | dhwprio | dhw priority | boolean | | True | switch.thermostat_hc1_dhw_priority | switch.thermostat_hc1_dhwprio | 6 | 1 | 1 | 33 | 1 |
Rego 2000/3000 | thermostat | 172 | hpcooling | hp cooling | boolean | | True | switch.thermostat_hc1_hp_cooling | switch.thermostat_hc1_hpcooling | 6 | 1 | 1 | 34 | 1 |
Rego 2000/3000 | thermostat | 172 | coolingon | cooling on | boolean | | False | binary_sensor.thermostat_hc1_cooling_on | binary_sensor.thermostat_hc1_coolingon | 6 | 1 | 1 | 35 | 1 |
Rego 2000/3000 | thermostat | 172 | hpmode | HP Mode | enum [heating|cooling|heating & cooling] | | True | select.thermostat_hc1_HP_Mode | select.thermostat_hc1_hpmode | 6 | 1 | 1 | 36 | 1 |
Rego 2000/3000 | thermostat | 172 | dewoffset | dew point offset | uint8 (>=2<=10) | K | True | number.thermostat_hc1_dew_point_offset | number.thermostat_hc1_dewoffset | 6 | 1 | 1 | 37 | 1 |
Rego 2000/3000 | thermostat | 172 | roomtempdiff | room temp difference | uint8 (>=0<=254) | K | True | number.thermostat_hc1_room_temp_difference | number.thermostat_hc1_roomtempdiff | 6 | 1 | 1 | 38 | 1 |
Rego 2000/3000 | thermostat | 172 | hpminflowtemp | HP min. flow temp. | uint8 (>=0<=254) | C | True | number.thermostat_hc1_HP_min._flow_temp. | number.thermostat_hc1_hpminflowtemp | 6 | 1 | 1 | 39 | 1 |
Rego 2000/3000 | thermostat | 172 | control | control device | enum [RC310|RC200|RC100|RC100H|TC100] | | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | 6 | 1 | 1 | 40 | 1 |
Rego 2000/3000 | thermostat | 172 | remotetemp | room temperature from remote | cmd [] (>=-1<=101) | C | True | sensor.thermostat_hc1_room_temperature_from_remote | sensor.thermostat_hc1_remotetemp | 6 | 1 | 1/10 | 41 | 1 |
Rego 2000/3000 | thermostat | 172 | remotehum | room humidity from remote | cmd [] (>=-1<=101) | % | True | sensor.thermostat_hc1_room_humidity_from_remote | sensor.thermostat_hc1_remotehum | 6 | 1 | 1 | 42 | 1 |
Rego 2000/3000 | thermostat | 172 | heatondelay | heat-on delay | uint8 (>=1<=48) | hours | True | number.thermostat_hc1_heat-on_delay | number.thermostat_hc1_heatondelay | 6 | 1 | 1 | 43 | 1 |
Rego 2000/3000 | thermostat | 172 | heatoffdelay | heat-off delay | uint8 (>=1<=48) | hours | True | number.thermostat_hc1_heat-off_delay | number.thermostat_hc1_heatoffdelay | 6 | 1 | 1 | 44 | 1 |
Rego 2000/3000 | thermostat | 172 | instantstart | instant start | uint8 (>=1<=10) | K | True | number.thermostat_hc1_instant_start | number.thermostat_hc1_instantstart | 6 | 1 | 1 | 45 | 1 |
Rego 2000/3000 | thermostat | 172 | boost | boost mode | boolean | | True | switch.thermostat_hc1_boost_mode | switch.thermostat_hc1_boost | 6 | 1 | 1 | 46 | 1 |
Rego 2000/3000 | thermostat | 172 | boosttime | boost time | uint8 (>=0<=254) | hours | True | number.thermostat_hc1_boost_time | number.thermostat_hc1_boosttime | 6 | 1 | 1 | 47 | 1 |
Rego 2000/3000 | thermostat | 172 | coolstart | cooling starttemp | uint8 (>=20<=35) | C | True | number.thermostat_hc1_cooling_starttemp | number.thermostat_hc1_coolstart | 6 | 1 | 1 | 48 | 1 |
Rego 2000/3000 | thermostat | 172 | coolondelay | cooling on delay | uint8 (>=1<=48) | hours | True | number.thermostat_hc1_cooling_on_delay | number.thermostat_hc1_coolondelay | 6 | 1 | 1 | 49 | 1 |
Rego 2000/3000 | thermostat | 172 | cooloffdelay | cooling off delay | uint8 (>=1<=48) | hours | True | number.thermostat_hc1_cooling_off_delay | number.thermostat_hc1_cooloffdelay | 6 | 1 | 1 | 50 | 1 |
Rego 2000/3000 | thermostat | 172 | switchprogmode | switch program mode | enum [level|absolute] | | True | select.thermostat_hc1_switch_program_mode | select.thermostat_hc1_switchprogmode | 6 | 1 | 1 | 51 | 1 |
Rego 2000/3000 | thermostat | 172 | mode | operating mode | enum [normal|comfort|eco+] | | True | select.thermostat_dhw_operating_mode | select.thermostat_dhw_mode | 6 | 9 | 1 | 0 | 1 |
Rego 2000/3000 | thermostat | 172 | settemp | set temperature | uint8 (>=0<=254) | C | True | number.thermostat_dhw_set_temperature | number.thermostat_dhw_settemp | 6 | 9 | 1 | 1 | 1 |
Rego 2000/3000 | thermostat | 172 | settemplow | set low temperature | uint8 (>=0<=254) | C | True | number.thermostat_dhw_set_low_temperature | number.thermostat_dhw_settemplow | 6 | 9 | 1 | 2 | 1 |
Rego 2000/3000 | thermostat | 172 | circmode | circulation pump mode | enum [off|on|auto|own prog] | | True | select.thermostat_dhw_circulation_pump_mode | select.thermostat_dhw_circmode | 6 | 9 | 1 | 3 | 1 |
Rego 2000/3000 | thermostat | 172 | chargeduration | charge duration | uint8 (>=0<=3810) | minutes | True | number.thermostat_dhw_charge_duration | number.thermostat_dhw_chargeduration | 6 | 9 | 15 | 4 | 1 |
Rego 2000/3000 | thermostat | 172 | charge | charge | boolean | | True | switch.thermostat_dhw_charge | switch.thermostat_dhw_charge | 6 | 9 | 1 | 5 | 1 |
Rego 2000/3000 | thermostat | 172 | extra | extra | uint8 (>=0<=254) | C | False | sensor.thermostat_dhw_extra | sensor.thermostat_dhw_extra | 6 | 9 | 1 | 6 | 1 |
Rego 2000/3000 | thermostat | 172 | disinfecting | disinfecting | boolean | | True | switch.thermostat_dhw_disinfecting | switch.thermostat_dhw_disinfecting | 6 | 9 | 1 | 7 | 1 |
Rego 2000/3000 | thermostat | 172 | disinfectday | disinfection day | enum [mo|tu|we|th|fr|sa|su|all] | | True | select.thermostat_dhw_disinfection_day | select.thermostat_dhw_disinfectday | 6 | 9 | 1 | 8 | 1 |
Rego 2000/3000 | thermostat | 172 | disinfecttime | disinfection time | uint8 (>=0<=1431) | minutes | True | number.thermostat_dhw_disinfection_time | number.thermostat_dhw_disinfecttime | 6 | 9 | 15 | 9 | 1 |
Rego 2000/3000 | thermostat | 172 | dailyheating | daily heating | boolean | | True | switch.thermostat_dhw_daily_heating | switch.thermostat_dhw_dailyheating | 6 | 9 | 1 | 10 | 1 |
Rego 2000/3000 | thermostat | 172 | dailyheattime | daily heating time | uint8 (>=0<=1431) | minutes | True | number.thermostat_dhw_daily_heating_time | number.thermostat_dhw_dailyheattime | 6 | 9 | 15 | 11 | 1 |
Comfort RF | thermostat | 215 | errorcode | error code | string | | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | 6 | 0 | 1 | 0 | 8 |
Comfort RF | thermostat | 215 | lastcode | last error code | string | | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | 6 | 0 | 1 | 8 | 25 |
Comfort RF | thermostat | 215 | datetime | date/time | string | | False | sensor.thermostat_date/time | sensor.thermostat_datetime | 6 | 0 | 1 | 33 | 13 |
Comfort RF | thermostat | 215 | seltemp | selected room temperature | int16 (>=-15999<=15999) | C | False | sensor.thermostat_hc1_selected_room_temperature | sensor.thermostat_hc1_seltemp | 6 | 1 | 1/2 | 0 | 1 |
Comfort RF | thermostat | 215 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp | 6 | 1 | 1/10 | 1 | 1 |
Comfort RF | thermostat | 215 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | 6 | 1 | 1 | 2 | 1 |
Comfort RF | thermostat | 215 | mode | operating mode | enum [auto|off] | | False | sensor.thermostat_hc1_operating_mode | sensor.thermostat_hc1_mode | 6 | 1 | 1 | 3 | 1 |
Comfort RF | thermostat | 215 | modetype | mode type | enum [off|on] | | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | 6 | 1 | 1 | 4 | 1 |
Comfort RF | thermostat | 215 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp | 6 | 1 | 1 | 18 | 1 |
CRF200S | thermostat | 216 | errorcode | error code | string | | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | 6 | 0 | 1 | 0 | 8 |
CRF200S | thermostat | 216 | lastcode | last error code | string | | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | 6 | 0 | 1 | 8 | 25 |
CRF200S | thermostat | 216 | datetime | date/time | string | | False | sensor.thermostat_date/time | sensor.thermostat_datetime | 6 | 0 | 1 | 33 | 13 |
CRF200S | thermostat | 216 | seltemp | selected room temperature | int16 (>=-15999<=15999) | C | False | sensor.thermostat_hc1_selected_room_temperature | sensor.thermostat_hc1_seltemp | 6 | 1 | 1/2 | 0 | 1 |
CRF200S | thermostat | 216 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp | 6 | 1 | 1/10 | 1 | 1 |
CRF200S | thermostat | 216 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | 6 | 1 | 1 | 2 | 1 |
CRF200S | thermostat | 216 | mode | operating mode | enum [auto|off] | | False | sensor.thermostat_hc1_operating_mode | sensor.thermostat_hc1_mode | 6 | 1 | 1 | 3 | 1 |
CRF200S | thermostat | 216 | modetype | mode type | enum [off|on] | | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | 6 | 1 | 1 | 4 | 1 |
CRF200S | thermostat | 216 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp | 6 | 1 | 1 | 18 | 1 |
Comfort+2RF | thermostat | 246 | errorcode | error code | string | | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | 6 | 0 | 1 | 0 | 8 |
Comfort+2RF | thermostat | 246 | lastcode | last error code | string | | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | 6 | 0 | 1 | 8 | 25 |
Comfort+2RF | thermostat | 246 | datetime | date/time | string | | False | sensor.thermostat_date/time | sensor.thermostat_datetime | 6 | 0 | 1 | 33 | 13 |
Comfort+2RF | thermostat | 246 | seltemp | selected room temperature | int16 (>=-15999<=15999) | C | False | sensor.thermostat_hc1_selected_room_temperature | sensor.thermostat_hc1_seltemp | 6 | 1 | 1/2 | 0 | 1 |
Comfort+2RF | thermostat | 246 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp | 6 | 1 | 1/10 | 1 | 1 |
Comfort+2RF | thermostat | 246 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | 6 | 1 | 1 | 2 | 1 |
Comfort+2RF | thermostat | 246 | mode | operating mode | enum [auto|off] | | False | sensor.thermostat_hc1_operating_mode | sensor.thermostat_hc1_mode | 6 | 1 | 1 | 3 | 1 |
Comfort+2RF | thermostat | 246 | modetype | mode type | enum [off|on] | | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | 6 | 1 | 1 | 4 | 1 |
Comfort+2RF | thermostat | 246 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp | 6 | 1 | 1 | 18 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | errorcode | error code | string | | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | 6 | 0 | 1 | 0 | 8 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | lastcode | last error code | string | | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | 6 | 0 | 1 | 8 | 25 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | datetime | date/time | string | | True | sensor.thermostat_date/time | sensor.thermostat_datetime | 6 | 0 | 1 | 33 | 13 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | intoffset | internal temperature offset | int8 (>=-12<=12) | C | True | number.thermostat_internal_temperature_offset | number.thermostat_intoffset | 6 | 0 | 1/10 | 46 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | floordry | floor drying | enum [off|start|heat|hold|cool|end] | | False | sensor.thermostat_floor_drying | sensor.thermostat_floordry | 6 | 0 | 1 | 47 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | dampedoutdoortemp | damped outdoor temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_damped_outdoor_temperature | sensor.thermostat_dampedoutdoortemp | 6 | 0 | 1/10 | 48 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | floordrytemp | floor drying temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_floor_drying_temperature | sensor.thermostat_floordrytemp | 6 | 0 | 1 | 49 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | building | building type | enum [light|medium|heavy] | | True | select.thermostat_building_type | select.thermostat_building | 6 | 0 | 1 | 50 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | minexttemp | minimal external temperature | int8 (>=-126<=126) | C | True | number.thermostat_minimal_external_temperature | number.thermostat_minexttemp | 6 | 0 | 1 | 51 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | damping | damping outdoor temperature | boolean | | True | switch.thermostat_damping_outdoor_temperature | switch.thermostat_damping | 6 | 0 | 1 | 52 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | hybridstrategy | hybrid control strategy | enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] | | True | select.thermostat_hybrid_control_strategy | select.thermostat_hybridstrategy | 6 | 0 | 1 | 53 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | switchovertemp | outside switchover temperature | int8 (>=-20<=20) | C | True | number.thermostat_outside_switchover_temperature | number.thermostat_switchovertemp | 6 | 0 | 1 | 54 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | energycostratio | energy cost ratio | uint8 (>=0<=20) | | True | number.thermostat_energy_cost_ratio | number.thermostat_energycostratio | 6 | 0 | 1/10 | 55 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | fossilefactor | fossile energy factor | uint8 (>=0<=5) | | True | number.thermostat_fossile_energy_factor | number.thermostat_fossilefactor | 6 | 0 | 1/10 | 56 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | electricfactor | electric energy factor | uint8 (>=0<=5) | | True | number.thermostat_electric_energy_factor | number.thermostat_electricfactor | 6 | 0 | 1/10 | 57 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | delayboiler | delay boiler support | uint8 (>=5<=120) | minutes | True | number.thermostat_delay_boiler_support | number.thermostat_delayboiler | 6 | 0 | 1 | 58 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | tempdiffboiler | temp diff boiler support | uint8 (>=1<=99) | C | True | number.thermostat_temp_diff_boiler_support | number.thermostat_tempdiffboiler | 6 | 0 | 1 | 59 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | pvenabledhw | enable raise dhw | boolean | | True | switch.thermostat_enable_raise_dhw | switch.thermostat_pvenabledhw | 6 | 0 | 1 | 60 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | pvraiseheat | raise heating with PV | int8 (>=0<=5) | K | True | number.thermostat_raise_heating_with_PV | number.thermostat_pvraiseheat | 6 | 0 | 1 | 61 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | pvlowercool | lower cooling with PV | int8 (>=-5<=0) | K | True | number.thermostat_lower_cooling_with_PV | number.thermostat_pvlowercool | 6 | 0 | 1 | 62 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp | 6 | 1 | 1/2 | 0 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp | 6 | 1 | 1/10 | 1 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | 6 | 1 | 1 | 2 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | mode | operating mode | enum [off|manual|auto] | | True | select.thermostat_hc1_operating_mode | select.thermostat_hc1_mode | 6 | 1 | 1 | 3 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | modetype | mode type | enum [eco|comfort] | | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | 6 | 1 | 1 | 4 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | ecotemp | eco temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_eco_temperature | number.thermostat_hc1_ecotemp | 6 | 1 | 1/2 | 5 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | manualtemp | manual temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_manual_temperature | number.thermostat_hc1_manualtemp | 6 | 1 | 1/2 | 6 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | comforttemp | comfort temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_comfort_temperature | number.thermostat_hc1_comforttemp | 6 | 1 | 1/2 | 7 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | summertemp | summer temperature | uint8 (>=10<=30) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp | 6 | 1 | 1 | 8 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | designtemp | design temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp | 6 | 1 | 1 | 9 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | offsettemp | offset temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_offset_temperature | number.thermostat_hc1_offsettemp | 6 | 1 | 1 | 10 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | minflowtemp | min flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp | 6 | 1 | 1 | 11 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | maxflowtemp | max flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp | 6 | 1 | 1 | 12 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | roominfluence | room influence | uint8 (>=0<=254) | C | True | number.thermostat_hc1_room_influence | number.thermostat_hc1_roominfluence | 6 | 1 | 1 | 13 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | roominflfactor | room influence factor | uint8 (>=0<=25) | | True | number.thermostat_hc1_room_influence_factor | number.thermostat_hc1_roominflfactor | 6 | 1 | 1/10 | 14 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | curroominfl | current room influence | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_influence | sensor.thermostat_hc1_curroominfl | 6 | 1 | 1/10 | 15 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | nofrostmode | nofrost mode | enum [room|outdoor|room outdoor] | | True | select.thermostat_hc1_nofrost_mode | select.thermostat_hc1_nofrostmode | 6 | 1 | 1 | 16 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | nofrosttemp | nofrost temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp | 6 | 1 | 1 | 17 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp | 6 | 1 | 1 | 18 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | heatingtype | heating type | enum [off|radiator|convector|floor] | | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | 6 | 1 | 1 | 19 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | summersetmode | set summer mode | enum [summer|auto|winter] | | True | select.thermostat_hc1_set_summer_mode | select.thermostat_hc1_summersetmode | 6 | 1 | 1 | 20 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | hpoperatingmode | heatpump operating mode | enum [off|auto|heating|cooling] | | True | select.thermostat_hc1_heatpump_operating_mode | select.thermostat_hc1_hpoperatingmode | 6 | 1 | 1 | 21 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | summermode | summer mode | enum [winter|summer] | | False | sensor.thermostat_hc1_summer_mode | sensor.thermostat_hc1_summermode | 6 | 1 | 1 | 22 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | hpoperatingstate | heatpump operating state | enum [heating|off|cooling] | | False | sensor.thermostat_hc1_heatpump_operating_state | sensor.thermostat_hc1_hpoperatingstate | 6 | 1 | 1 | 23 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | controlmode | control mode | enum [weather compensated|outside basepoint|n/a|room|power|constant] | | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | 6 | 1 | 1 | 24 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | program | program | enum [prog 1|prog 2] | | True | select.thermostat_hc1_program | select.thermostat_hc1_program | 6 | 1 | 1 | 25 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | tempautotemp | temporary set temperature automode | int8 (>=-1<=30) | C | True | number.thermostat_hc1_temporary_set_temperature_automode | number.thermostat_hc1_tempautotemp | 6 | 1 | 1/2 | 26 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | remoteseltemp | temporary set temperature from remote | int8 (>=-1<=30) | C | True | number.thermostat_hc1_temporary_set_temperature_from_remote | number.thermostat_hc1_remoteseltemp | 6 | 1 | 1/2 | 27 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | fastheatup | fast heatup | uint8 (>=0<=100) | % | True | number.thermostat_hc1_fast_heatup | number.thermostat_hc1_fastheatup | 6 | 1 | 1 | 28 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | switchonoptimization | switch-on optimization | boolean | | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | 6 | 1 | 1 | 29 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | reducemode | reduce mode | enum [outdoor|room|reduce] | | True | select.thermostat_hc1_reduce_mode | select.thermostat_hc1_reducemode | 6 | 1 | 1 | 30 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | noreducetemp | no reduce below temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_no_reduce_below_temperature | number.thermostat_hc1_noreducetemp | 6 | 1 | 1 | 31 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | reducetemp | off/reduce switch temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_off/reduce_switch_temperature | number.thermostat_hc1_reducetemp | 6 | 1 | 1 | 32 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | dhwprio | dhw priority | boolean | | True | switch.thermostat_hc1_dhw_priority | switch.thermostat_hc1_dhwprio | 6 | 1 | 1 | 33 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | hpcooling | hp cooling | boolean | | True | switch.thermostat_hc1_hp_cooling | switch.thermostat_hc1_hpcooling | 6 | 1 | 1 | 34 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | coolingon | cooling on | boolean | | False | binary_sensor.thermostat_hc1_cooling_on | binary_sensor.thermostat_hc1_coolingon | 6 | 1 | 1 | 35 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | hpmode | HP Mode | enum [heating|cooling|heating & cooling] | | True | select.thermostat_hc1_HP_Mode | select.thermostat_hc1_hpmode | 6 | 1 | 1 | 36 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | dewoffset | dew point offset | uint8 (>=2<=10) | K | True | number.thermostat_hc1_dew_point_offset | number.thermostat_hc1_dewoffset | 6 | 1 | 1 | 37 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | roomtempdiff | room temp difference | uint8 (>=0<=254) | K | True | number.thermostat_hc1_room_temp_difference | number.thermostat_hc1_roomtempdiff | 6 | 1 | 1 | 38 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | hpminflowtemp | HP min. flow temp. | uint8 (>=0<=254) | C | True | number.thermostat_hc1_HP_min._flow_temp. | number.thermostat_hc1_hpminflowtemp | 6 | 1 | 1 | 39 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | control | control device | enum [off|-|RC100|RC100H|-|RC120RF|RC220/RT800|single] | | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | 6 | 1 | 1 | 40 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | remotetemp | room temperature from remote | cmd [] (>=-1<=101) | C | True | sensor.thermostat_hc1_room_temperature_from_remote | sensor.thermostat_hc1_remotetemp | 6 | 1 | 1/10 | 41 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | remotehum | room humidity from remote | cmd [] (>=-1<=101) | % | True | sensor.thermostat_hc1_room_humidity_from_remote | sensor.thermostat_hc1_remotehum | 6 | 1 | 1 | 42 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | heatondelay | heat-on delay | uint8 (>=1<=48) | hours | True | number.thermostat_hc1_heat-on_delay | number.thermostat_hc1_heatondelay | 6 | 1 | 1 | 43 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | heatoffdelay | heat-off delay | uint8 (>=1<=48) | hours | True | number.thermostat_hc1_heat-off_delay | number.thermostat_hc1_heatoffdelay | 6 | 1 | 1 | 44 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | instantstart | instant start | uint8 (>=1<=10) | K | True | number.thermostat_hc1_instant_start | number.thermostat_hc1_instantstart | 6 | 1 | 1 | 45 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | boost | boost mode | boolean | | True | switch.thermostat_hc1_boost_mode | switch.thermostat_hc1_boost | 6 | 1 | 1 | 46 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | boosttime | boost time | uint8 (>=0<=254) | hours | True | number.thermostat_hc1_boost_time | number.thermostat_hc1_boosttime | 6 | 1 | 1 | 47 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | coolstart | cooling starttemp | uint8 (>=20<=35) | C | True | number.thermostat_hc1_cooling_starttemp | number.thermostat_hc1_coolstart | 6 | 1 | 1 | 48 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | coolondelay | cooling on delay | uint8 (>=1<=48) | hours | True | number.thermostat_hc1_cooling_on_delay | number.thermostat_hc1_coolondelay | 6 | 1 | 1 | 49 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | cooloffdelay | cooling off delay | uint8 (>=1<=48) | hours | True | number.thermostat_hc1_cooling_off_delay | number.thermostat_hc1_cooloffdelay | 6 | 1 | 1 | 50 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | switchprogmode | switch program mode | enum [level|absolute] | | True | select.thermostat_hc1_switch_program_mode | select.thermostat_hc1_switchprogmode | 6 | 1 | 1 | 51 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | mode | operating mode | enum [off|eco+|eco|comfort|auto] | | True | select.thermostat_dhw_operating_mode | select.thermostat_dhw_mode | 6 | 9 | 1 | 0 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | settemp | set temperature | uint8 (>=0<=254) | C | True | number.thermostat_dhw_set_temperature | number.thermostat_dhw_settemp | 6 | 9 | 1 | 1 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | settemplow | set low temperature | uint8 (>=0<=254) | C | True | number.thermostat_dhw_set_low_temperature | number.thermostat_dhw_settemplow | 6 | 9 | 1 | 2 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | circmode | circulation pump mode | enum [off|on|auto|own prog] | | True | select.thermostat_dhw_circulation_pump_mode | select.thermostat_dhw_circmode | 6 | 9 | 1 | 3 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | chargeduration | charge duration | uint8 (>=0<=3810) | minutes | True | number.thermostat_dhw_charge_duration | number.thermostat_dhw_chargeduration | 6 | 9 | 15 | 4 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | charge | charge | boolean | | True | switch.thermostat_dhw_charge | switch.thermostat_dhw_charge | 6 | 9 | 1 | 5 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | extra | extra | uint8 (>=0<=254) | C | False | sensor.thermostat_dhw_extra | sensor.thermostat_dhw_extra | 6 | 9 | 1 | 6 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | disinfecting | disinfecting | boolean | | True | switch.thermostat_dhw_disinfecting | switch.thermostat_dhw_disinfecting | 6 | 9 | 1 | 7 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | disinfectday | disinfection day | enum [mo|tu|we|th|fr|sa|su|all] | | True | select.thermostat_dhw_disinfection_day | select.thermostat_dhw_disinfectday | 6 | 9 | 1 | 8 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | disinfecttime | disinfection time | uint8 (>=0<=1431) | minutes | True | number.thermostat_dhw_disinfection_time | number.thermostat_dhw_disinfecttime | 6 | 9 | 15 | 9 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | dailyheating | daily heating | boolean | | True | switch.thermostat_dhw_daily_heating | switch.thermostat_dhw_dailyheating | 6 | 9 | 1 | 10 | 1 |
Rego 3000, UI800, Logamatic BC400 | thermostat | 253 | dailyheattime | daily heating time | uint8 (>=0<=1431) | minutes | True | number.thermostat_dhw_daily_heating_time | number.thermostat_dhw_dailyheattime | 6 | 9 | 15 | 11 | 1 |
ES72, RC20 | thermostat | 66 | errorcode | error code | string | | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | 6 | 0 | 1 | 0 | 8 |
ES72, RC20 | thermostat | 66 | lastcode | last error code | string | | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | 6 | 0 | 1 | 8 | 25 |
ES72, RC20 | thermostat | 66 | datetime | date/time | string | | False | sensor.thermostat_date/time | sensor.thermostat_datetime | 6 | 0 | 1 | 33 | 13 |
ES72, RC20 | thermostat | 66 | minexttemp | minimal external temperature | int8 (>=-126<=126) | C | True | number.thermostat_minimal_external_temperature | number.thermostat_minexttemp | 6 | 0 | 1 | 51 | 1 |
ES72, RC20 | thermostat | 66 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp | 6 | 1 | 1/2 | 0 | 1 |
ES72, RC20 | thermostat | 66 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp | 6 | 1 | 1/10 | 1 | 1 |
ES72, RC20 | thermostat | 66 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | 6 | 1 | 1 | 2 | 1 |
ES72, RC20 | thermostat | 66 | mode | operating mode | enum [night|day|auto] | | True | select.thermostat_hc1_operating_mode | select.thermostat_hc1_mode | 6 | 1 | 1 | 3 | 1 |
ES72, RC20 | thermostat | 66 | modetype | mode type | enum [night|day] | | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | 6 | 1 | 1 | 4 | 1 |
ES72, RC20 | thermostat | 66 | daytemp | day temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_day_temperature | number.thermostat_hc1_daytemp | 6 | 1 | 1/2 | 52 | 1 |
ES72, RC20 | thermostat | 66 | nighttemp | night temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_night_temperature | number.thermostat_hc1_nighttemp | 6 | 1 | 1/2 | 53 | 1 |
ES72, RC20 | thermostat | 66 | program | program | enum [family|morning|evening|am|pm|midday|singles|seniors] | | True | select.thermostat_hc1_program | select.thermostat_hc1_program | 6 | 1 | 1 | 25 | 1 |
ES72, RC20 | thermostat | 66 | minflowtemp | min flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp | 6 | 1 | 1 | 11 | 1 |
ES72, RC20 | thermostat | 66 | maxflowtemp | max flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp | 6 | 1 | 1 | 12 | 1 |
ES72, RC20 | thermostat | 66 | tempautotemp | temporary set temperature automode | uint8 (>=0<=127) | C | True | number.thermostat_hc1_temporary_set_temperature_automode | number.thermostat_hc1_tempautotemp | 6 | 1 | 1/2 | 26 | 1 |
ES72, RC20 | thermostat | 66 | heatingtype | heating type | enum [off|radiator|convector|floor] | | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | 6 | 1 | 1 | 19 | 1 |
ES72, RC20 | thermostat | 66 | summertemp | summer temperature | uint8 (>=10<=30) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp | 6 | 1 | 1 | 8 | 1 |
ES72, RC20 | thermostat | 66 | summermode | summer mode | enum [winter|summer] | | False | sensor.thermostat_hc1_summer_mode | sensor.thermostat_hc1_summermode | 6 | 1 | 1 | 22 | 1 |
ES73 | thermostat | 76 | errorcode | error code | string | | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | 6 | 0 | 1 | 0 | 8 |
ES73 | thermostat | 76 | lastcode | last error code | string | | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | 6 | 0 | 1 | 8 | 25 |
ES73 | thermostat | 76 | datetime | date/time | string | | False | sensor.thermostat_date/time | sensor.thermostat_datetime | 6 | 0 | 1 | 33 | 13 |
ES73 | thermostat | 76 | display | display | enum [internal temperature|internal setpoint|external temperature|burner temperature|dhw temperature|functioning mode|time|date|smoke temperature] | | True | select.thermostat_display | select.thermostat_display | 6 | 0 | 1 | 63 | 1 |
ES73 | thermostat | 76 | language | language | enum [german|dutch|french|italian] | | False | sensor.thermostat_language | sensor.thermostat_language | 6 | 0 | 1 | 64 | 1 |
ES73 | thermostat | 76 | clockoffset | clock offset | int8 (>=-126<=126) | seconds | True | number.thermostat_clock_offset | number.thermostat_clockoffset | 6 | 0 | 1 | 65 | 1 |
ES73 | thermostat | 76 | intoffset | internal temperature offset | int8 (>=-12<=12) | C | True | number.thermostat_internal_temperature_offset | number.thermostat_intoffset | 6 | 0 | 1/10 | 46 | 1 |
ES73 | thermostat | 76 | minexttemp | minimal external temperature | int8 (>=-126<=126) | C | True | number.thermostat_minimal_external_temperature | number.thermostat_minexttemp | 6 | 0 | 1 | 51 | 1 |
ES73 | thermostat | 76 | inttemp1 | temperature sensor 1 | int16 (>=-3199<=3199) | C | False | sensor.thermostat_temperature_sensor_1 | sensor.thermostat_inttemp1 | 6 | 0 | 1/10 | 66 | 1 |
ES73 | thermostat | 76 | inttemp2 | temperature sensor 2 | int16 (>=-3199<=3199) | C | False | sensor.thermostat_temperature_sensor_2 | sensor.thermostat_inttemp2 | 6 | 0 | 1/10 | 67 | 1 |
ES73 | thermostat | 76 | damping | damping outdoor temperature | boolean | | True | switch.thermostat_damping_outdoor_temperature | switch.thermostat_damping | 6 | 0 | 1 | 52 | 1 |
ES73 | thermostat | 76 | dampedoutdoortemp | damped outdoor temperature | int8 (>=-126<=126) | C | False | sensor.thermostat_damped_outdoor_temperature | sensor.thermostat_dampedoutdoortemp | 6 | 0 | 1 | 48 | 1 |
ES73 | thermostat | 76 | building | building type | enum [light|medium|heavy] | | True | select.thermostat_building_type | select.thermostat_building | 6 | 0 | 1 | 50 | 1 |
ES73 | thermostat | 76 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp | 6 | 1 | 1/2 | 0 | 1 |
ES73 | thermostat | 76 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp | 6 | 1 | 1/10 | 1 | 1 |
ES73 | thermostat | 76 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | 6 | 1 | 1 | 2 | 1 |
ES73 | thermostat | 76 | mode | operating mode | enum [night|day|auto] | | True | select.thermostat_hc1_operating_mode | select.thermostat_hc1_mode | 6 | 1 | 1 | 3 | 1 |
ES73 | thermostat | 76 | modetype | mode type | enum [night|day] | | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | 6 | 1 | 1 | 4 | 1 |
ES73 | thermostat | 76 | daytemp | day temperature | uint8 (>=10<=30) | C | True | number.thermostat_hc1_day_temperature | number.thermostat_hc1_daytemp | 6 | 1 | 1/2 | 52 | 1 |
ES73 | thermostat | 76 | nighttemp | night temperature | uint8 (>=10<=30) | C | True | number.thermostat_hc1_night_temperature | number.thermostat_hc1_nighttemp | 6 | 1 | 1/2 | 53 | 1 |
ES73 | thermostat | 76 | designtemp | design temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp | 6 | 1 | 1 | 9 | 1 |
ES73 | thermostat | 76 | offsettemp | offset temperature | int8 (>=-5<=5) | C | True | number.thermostat_hc1_offset_temperature | number.thermostat_hc1_offsettemp | 6 | 1 | 1/2 | 10 | 1 |
ES73 | thermostat | 76 | holidaytemp | holiday temperature | uint8 (>=5<=30) | C | True | number.thermostat_hc1_holiday_temperature | number.thermostat_hc1_holidaytemp | 6 | 1 | 1/2 | 54 | 1 |
ES73 | thermostat | 76 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp | 6 | 1 | 1 | 18 | 1 |
ES73 | thermostat | 76 | summertemp | summer temperature | uint8 (>=9<=25) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp | 6 | 1 | 1 | 8 | 1 |
ES73 | thermostat | 76 | summermode | summer mode | enum [winter|summer] | | False | sensor.thermostat_hc1_summer_mode | sensor.thermostat_hc1_summermode | 6 | 1 | 1 | 22 | 1 |
ES73 | thermostat | 76 | holidaymode | holiday mode | boolean | | False | binary_sensor.thermostat_hc1_holiday_mode | binary_sensor.thermostat_hc1_holidaymode | 6 | 1 | 1 | 55 | 1 |
ES73 | thermostat | 76 | nofrosttemp | nofrost temperature | int8 (>=-20<=10) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp | 6 | 1 | 1 | 17 | 1 |
ES73 | thermostat | 76 | nofrostmode | nofrost mode | enum [off|outdoor|room] | | True | select.thermostat_hc1_nofrost_mode | select.thermostat_hc1_nofrostmode | 6 | 1 | 1 | 16 | 1 |
ES73 | thermostat | 76 | roominfluence | room influence | uint8 (>=0<=10) | C | True | number.thermostat_hc1_room_influence | number.thermostat_hc1_roominfluence | 6 | 1 | 1 | 13 | 1 |
ES73 | thermostat | 76 | minflowtemp | min flow temperature | uint8 (>=5<=70) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp | 6 | 1 | 1 | 11 | 1 |
ES73 | thermostat | 76 | maxflowtemp | max flow temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp | 6 | 1 | 1 | 12 | 1 |
ES73 | thermostat | 76 | flowtempoffset | flow temperature offset for mixer | uint8 (>=0<=20) | C | True | number.thermostat_hc1_flow_temperature_offset_for_mixer | number.thermostat_hc1_flowtempoffset | 6 | 1 | 1 | 56 | 1 |
ES73 | thermostat | 76 | heatingtype | heating type | enum [off|radiator|convector|floor] | | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | 6 | 1 | 1 | 19 | 1 |
ES73 | thermostat | 76 | reducemode | reduce mode | enum [nofrost|reduce|room|outdoor] | | True | select.thermostat_hc1_reduce_mode | select.thermostat_hc1_reducemode | 6 | 1 | 1 | 30 | 1 |
ES73 | thermostat | 76 | controlmode | control mode | enum [outdoor|room] | | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | 6 | 1 | 1 | 24 | 1 |
ES73 | thermostat | 76 | control | control device | enum [off|RC20|RC3x] | | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | 6 | 1 | 1 | 40 | 1 |
ES73 | thermostat | 76 | holidays | holiday dates | string | | True | sensor.thermostat_hc1_holiday_dates | sensor.thermostat_hc1_holidays | 6 | 1 | 1 | 57 | 13 |
ES73 | thermostat | 76 | vacations | vacation dates | string | | True | sensor.thermostat_hc1_vacation_dates | sensor.thermostat_hc1_vacations | 6 | 1 | 1 | 70 | 13 |
ES73 | thermostat | 76 | program | program | enum [own 1|family|morning|evening|am|pm|midday|singles|seniors|new|own 2] | | True | select.thermostat_hc1_program | select.thermostat_hc1_program | 6 | 1 | 1 | 25 | 1 |
ES73 | thermostat | 76 | pause | pause time | uint8 (>=0<=99) | hours | True | number.thermostat_hc1_pause_time | number.thermostat_hc1_pause | 6 | 1 | 1 | 83 | 1 |
ES73 | thermostat | 76 | party | party time | uint8 (>=0<=99) | hours | True | number.thermostat_hc1_party_time | number.thermostat_hc1_party | 6 | 1 | 1 | 84 | 1 |
ES73 | thermostat | 76 | tempautotemp | temporary set temperature automode | uint8 (>=0<=30) | C | True | number.thermostat_hc1_temporary_set_temperature_automode | number.thermostat_hc1_tempautotemp | 6 | 1 | 1/2 | 26 | 1 |
ES73 | thermostat | 76 | noreducetemp | no reduce below temperature | int8 (>=-31<=10) | C | True | number.thermostat_hc1_no_reduce_below_temperature | number.thermostat_hc1_noreducetemp | 6 | 1 | 1 | 31 | 1 |
ES73 | thermostat | 76 | reducetemp | off/reduce switch temperature | int8 (>=-20<=10) | C | True | number.thermostat_hc1_off/reduce_switch_temperature | number.thermostat_hc1_reducetemp | 6 | 1 | 1 | 32 | 1 |
ES73 | thermostat | 76 | vacreducetemp | vacations off/reduce switch temperature | int8 (>=-20<=10) | C | True | number.thermostat_hc1_vacations_off/reduce_switch_temperature | number.thermostat_hc1_vacreducetemp | 6 | 1 | 1 | 85 | 1 |
ES73 | thermostat | 76 | vacreducemode | vacations reduce mode | enum [nofrost|reduce|room|outdoor] | | True | select.thermostat_hc1_vacations_reduce_mode | select.thermostat_hc1_vacreducemode | 6 | 1 | 1 | 86 | 1 |
ES73 | thermostat | 76 | remotetemp | room temperature from remote | cmd [] (>=-1<=101) | C | True | sensor.thermostat_hc1_room_temperature_from_remote | sensor.thermostat_hc1_remotetemp | 6 | 1 | 1/10 | 41 | 1 |
ES73 | thermostat | 76 | dhwprio | dhw priority | boolean | | True | switch.thermostat_hc1_dhw_priority | switch.thermostat_hc1_dhwprio | 6 | 1 | 1 | 33 | 1 |
ES73 | thermostat | 76 | switchonoptimization | switch-on optimization | boolean | | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | 6 | 1 | 1 | 29 | 1 |
ES73 | thermostat | 76 | switchtime1 | own1 program switchtime | string | | True | sensor.thermostat_hc1_own1_program_switchtime | sensor.thermostat_hc1_switchtime1 | 6 | 1 | 1 | 87 | 8 |
ES73 | thermostat | 76 | switchtime2 | own2 program switchtime | string | | True | sensor.thermostat_hc1_own2_program_switchtime | sensor.thermostat_hc1_switchtime2 | 6 | 1 | 1 | 95 | 8 |
ES73 | thermostat | 76 | mode | operating mode | enum [off|on|auto] | | True | select.thermostat_dhw_operating_mode | select.thermostat_dhw_mode | 6 | 9 | 1 | 0 | 1 |
ES73 | thermostat | 76 | circmode | circulation pump mode | enum [off|on|auto] | | True | select.thermostat_dhw_circulation_pump_mode | select.thermostat_dhw_circmode | 6 | 9 | 1 | 3 | 1 |
ES73 | thermostat | 76 | progmode | program | enum [std prog|own prog] | | True | select.thermostat_dhw_program | select.thermostat_dhw_progmode | 6 | 9 | 1 | 12 | 1 |
ES73 | thermostat | 76 | circprog | circulation program | enum [std prog|own prog] | | True | select.thermostat_dhw_circulation_program | select.thermostat_dhw_circprog | 6 | 9 | 1 | 13 | 1 |
ES73 | thermostat | 76 | disinfecting | disinfecting | boolean | | True | switch.thermostat_dhw_disinfecting | switch.thermostat_dhw_disinfecting | 6 | 9 | 1 | 7 | 1 |
ES73 | thermostat | 76 | disinfectday | disinfection day | enum [mo|tu|we|th|fr|sa|su|all] | | True | select.thermostat_dhw_disinfection_day | select.thermostat_dhw_disinfectday | 6 | 9 | 1 | 8 | 1 |
ES73 | thermostat | 76 | disinfecthour | disinfection hour | uint8 (>=0<=23) | | True | number.thermostat_dhw_disinfection_hour | number.thermostat_dhw_disinfecthour | 6 | 9 | 1 | 14 | 1 |
ES73 | thermostat | 76 | maxtemp | maximum temperature | uint8 (>=0<=254) | C | True | number.thermostat_dhw_maximum_temperature | number.thermostat_dhw_maxtemp | 6 | 9 | 1 | 15 | 1 |
ES73 | thermostat | 76 | onetimekey | one time key function | boolean | | True | switch.thermostat_dhw_one_time_key_function | switch.thermostat_dhw_onetimekey | 6 | 9 | 1 | 16 | 1 |
ES73 | thermostat | 76 | switchtimeWW | program switchtime warm water | string | | True | sensor.thermostat_dhw_program_switchtime_warm_water | sensor.thermostat_dhw_switchtimeWW | 6 | 9 | 1 | 17 | 11 |
ES73 | thermostat | 76 | circswitchtime | circulation program switchtime | string | | True | sensor.thermostat_dhw_circulation_program_switchtime | sensor.thermostat_dhw_circswitchtime | 6 | 9 | 1 | 28 | 8 |
ES73 | thermostat | 76 | holidays | holiday dates | string | | True | sensor.thermostat_dhw_holiday_dates | sensor.thermostat_dhw_holidays | 6 | 9 | 1 | 36 | 13 |
ES73 | thermostat | 76 | vacations | vacation dates | string | | True | sensor.thermostat_dhw_vacation_dates | sensor.thermostat_dhw_vacations | 6 | 9 | 1 | 49 | 13 |
ES72, RC20 | thermostat | 113 | errorcode | error code | string | | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | 6 | 0 | 1 | 0 | 8 |
ES72, RC20 | thermostat | 113 | lastcode | last error code | string | | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | 6 | 0 | 1 | 8 | 25 |
ES72, RC20 | thermostat | 113 | datetime | date/time | string | | False | sensor.thermostat_date/time | sensor.thermostat_datetime | 6 | 0 | 1 | 33 | 13 |
ES72, RC20 | thermostat | 113 | minexttemp | minimal external temperature | int8 (>=-126<=126) | C | True | number.thermostat_minimal_external_temperature | number.thermostat_minexttemp | 6 | 0 | 1 | 51 | 1 |
ES72, RC20 | thermostat | 113 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp | 6 | 1 | 1/2 | 0 | 1 |
ES72, RC20 | thermostat | 113 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp | 6 | 1 | 1/10 | 1 | 1 |
ES72, RC20 | thermostat | 113 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | 6 | 1 | 1 | 2 | 1 |
ES72, RC20 | thermostat | 113 | mode | operating mode | enum [night|day|auto] | | True | select.thermostat_hc1_operating_mode | select.thermostat_hc1_mode | 6 | 1 | 1 | 3 | 1 |
ES72, RC20 | thermostat | 113 | modetype | mode type | enum [night|day] | | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | 6 | 1 | 1 | 4 | 1 |
ES72, RC20 | thermostat | 113 | daytemp | day temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_day_temperature | number.thermostat_hc1_daytemp | 6 | 1 | 1/2 | 52 | 1 |
ES72, RC20 | thermostat | 113 | nighttemp | night temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_night_temperature | number.thermostat_hc1_nighttemp | 6 | 1 | 1/2 | 53 | 1 |
ES72, RC20 | thermostat | 113 | program | program | enum [family|morning|evening|am|pm|midday|singles|seniors] | | True | select.thermostat_hc1_program | select.thermostat_hc1_program | 6 | 1 | 1 | 25 | 1 |
ES72, RC20 | thermostat | 113 | minflowtemp | min flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp | 6 | 1 | 1 | 11 | 1 |
ES72, RC20 | thermostat | 113 | maxflowtemp | max flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp | 6 | 1 | 1 | 12 | 1 |
ES72, RC20 | thermostat | 113 | tempautotemp | temporary set temperature automode | uint8 (>=0<=127) | C | True | number.thermostat_hc1_temporary_set_temperature_automode | number.thermostat_hc1_tempautotemp | 6 | 1 | 1/2 | 26 | 1 |
ES72, RC20 | thermostat | 113 | heatingtype | heating type | enum [off|radiator|convector|floor] | | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | 6 | 1 | 1 | 19 | 1 |
ES72, RC20 | thermostat | 113 | summertemp | summer temperature | uint8 (>=10<=30) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp | 6 | 1 | 1 | 8 | 1 |
ES72, RC20 | thermostat | 113 | summermode | summer mode | enum [winter|summer] | | False | sensor.thermostat_hc1_summer_mode | sensor.thermostat_hc1_summermode | 6 | 1 | 1 | 22 | 1 |
ES79 | thermostat | 156 | errorcode | error code | string | | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | 6 | 0 | 1 | 0 | 8 |
ES79 | thermostat | 156 | lastcode | last error code | string | | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | 6 | 0 | 1 | 8 | 25 |
ES79 | thermostat | 156 | datetime | date/time | string | | True | sensor.thermostat_date/time | sensor.thermostat_datetime | 6 | 0 | 1 | 33 | 13 |
ES79 | thermostat | 156 | intoffset | internal temperature offset | int8 (>=-5<=5) | C | True | number.thermostat_internal_temperature_offset | number.thermostat_intoffset | 6 | 0 | 1/10 | 46 | 1 |
ES79 | thermostat | 156 | minexttemp | minimal external temperature | int8 (>=-30<=0) | C | True | number.thermostat_minimal_external_temperature | number.thermostat_minexttemp | 6 | 0 | 1 | 51 | 1 |
ES79 | thermostat | 156 | inttemp1 | temperature sensor 1 | int16 (>=-3199<=3199) | C | False | sensor.thermostat_temperature_sensor_1 | sensor.thermostat_inttemp1 | 6 | 0 | 1/10 | 66 | 1 |
ES79 | thermostat | 156 | inttemp2 | temperature sensor 2 | int16 (>=-3199<=3199) | C | False | sensor.thermostat_temperature_sensor_2 | sensor.thermostat_inttemp2 | 6 | 0 | 1/10 | 67 | 1 |
ES79 | thermostat | 156 | damping | damping outdoor temperature | boolean | | True | switch.thermostat_damping_outdoor_temperature | switch.thermostat_damping | 6 | 0 | 1 | 52 | 1 |
ES79 | thermostat | 156 | dampedoutdoortemp | damped outdoor temperature | int8 (>=-126<=126) | C | False | sensor.thermostat_damped_outdoor_temperature | sensor.thermostat_dampedoutdoortemp | 6 | 0 | 1 | 48 | 1 |
ES79 | thermostat | 156 | building | building type | enum [light|medium|heavy] | | True | select.thermostat_building_type | select.thermostat_building | 6 | 0 | 1 | 50 | 1 |
ES79 | thermostat | 156 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp | 6 | 1 | 1/2 | 0 | 1 |
ES79 | thermostat | 156 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp | 6 | 1 | 1/10 | 1 | 1 |
ES79 | thermostat | 156 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | 6 | 1 | 1 | 2 | 1 |
ES79 | thermostat | 156 | mode | operating mode | enum [night|day|auto] | | True | select.thermostat_hc1_operating_mode | select.thermostat_hc1_mode | 6 | 1 | 1 | 3 | 1 |
ES79 | thermostat | 156 | modetype | mode type | enum [night|day] | | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | 6 | 1 | 1 | 4 | 1 |
ES79 | thermostat | 156 | daytemp | day temperature | uint8 (>=10<=30) | C | True | number.thermostat_hc1_day_temperature | number.thermostat_hc1_daytemp | 6 | 1 | 1/2 | 52 | 1 |
ES79 | thermostat | 156 | nighttemp | night temperature | uint8 (>=10<=30) | C | True | number.thermostat_hc1_night_temperature | number.thermostat_hc1_nighttemp | 6 | 1 | 1/2 | 53 | 1 |
ES79 | thermostat | 156 | designtemp | design temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp | 6 | 1 | 1 | 9 | 1 |
ES79 | thermostat | 156 | offsettemp | offset temperature | int8 (>=-5<=5) | C | True | number.thermostat_hc1_offset_temperature | number.thermostat_hc1_offsettemp | 6 | 1 | 1/2 | 10 | 1 |
ES79 | thermostat | 156 | holidaytemp | holiday temperature | uint8 (>=5<=30) | C | True | number.thermostat_hc1_holiday_temperature | number.thermostat_hc1_holidaytemp | 6 | 1 | 1/2 | 54 | 1 |
ES79 | thermostat | 156 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp | 6 | 1 | 1 | 18 | 1 |
ES79 | thermostat | 156 | summertemp | summer temperature | uint8 (>=9<=25) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp | 6 | 1 | 1 | 8 | 1 |
ES79 | thermostat | 156 | summermode | summer mode | enum [winter|summer] | | False | sensor.thermostat_hc1_summer_mode | sensor.thermostat_hc1_summermode | 6 | 1 | 1 | 22 | 1 |
ES79 | thermostat | 156 | holidaymode | holiday mode | boolean | | False | binary_sensor.thermostat_hc1_holiday_mode | binary_sensor.thermostat_hc1_holidaymode | 6 | 1 | 1 | 55 | 1 |
ES79 | thermostat | 156 | nofrosttemp | nofrost temperature | int8 (>=-20<=10) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp | 6 | 1 | 1 | 17 | 1 |
ES79 | thermostat | 156 | nofrostmode | nofrost mode | enum [off|outdoor|room] | | True | select.thermostat_hc1_nofrost_mode | select.thermostat_hc1_nofrostmode | 6 | 1 | 1 | 16 | 1 |
ES79 | thermostat | 156 | roominfluence | room influence | uint8 (>=0<=10) | C | True | number.thermostat_hc1_room_influence | number.thermostat_hc1_roominfluence | 6 | 1 | 1 | 13 | 1 |
ES79 | thermostat | 156 | minflowtemp | min flow temperature | uint8 (>=5<=70) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp | 6 | 1 | 1 | 11 | 1 |
ES79 | thermostat | 156 | maxflowtemp | max flow temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp | 6 | 1 | 1 | 12 | 1 |
ES79 | thermostat | 156 | flowtempoffset | flow temperature offset for mixer | uint8 (>=0<=20) | C | True | number.thermostat_hc1_flow_temperature_offset_for_mixer | number.thermostat_hc1_flowtempoffset | 6 | 1 | 1 | 56 | 1 |
ES79 | thermostat | 156 | heatingtype | heating type | enum [off|radiator|convector|floor] | | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | 6 | 1 | 1 | 19 | 1 |
ES79 | thermostat | 156 | reducemode | reduce mode | enum [nofrost|reduce|room|outdoor] | | True | select.thermostat_hc1_reduce_mode | select.thermostat_hc1_reducemode | 6 | 1 | 1 | 30 | 1 |
ES79 | thermostat | 156 | controlmode | control mode | enum [outdoor|room] | | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | 6 | 1 | 1 | 24 | 1 |
ES79 | thermostat | 156 | control | control device | enum [off|RC20|RC3x] | | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | 6 | 1 | 1 | 40 | 1 |
ES79 | thermostat | 156 | holidays | holiday dates | string | | True | sensor.thermostat_hc1_holiday_dates | sensor.thermostat_hc1_holidays | 6 | 1 | 1 | 57 | 13 |
ES79 | thermostat | 156 | vacations | vacation dates | string | | True | sensor.thermostat_hc1_vacation_dates | sensor.thermostat_hc1_vacations | 6 | 1 | 1 | 70 | 13 |
ES79 | thermostat | 156 | program | program | enum [own 1|family|morning|evening|am|pm|midday|singles|seniors|new|own 2] | | True | select.thermostat_hc1_program | select.thermostat_hc1_program | 6 | 1 | 1 | 25 | 1 |
ES79 | thermostat | 156 | pause | pause time | uint8 (>=0<=99) | hours | True | number.thermostat_hc1_pause_time | number.thermostat_hc1_pause | 6 | 1 | 1 | 83 | 1 |
ES79 | thermostat | 156 | party | party time | uint8 (>=0<=99) | hours | True | number.thermostat_hc1_party_time | number.thermostat_hc1_party | 6 | 1 | 1 | 84 | 1 |
ES79 | thermostat | 156 | tempautotemp | temporary set temperature automode | uint8 (>=0<=30) | C | True | number.thermostat_hc1_temporary_set_temperature_automode | number.thermostat_hc1_tempautotemp | 6 | 1 | 1/2 | 26 | 1 |
ES79 | thermostat | 156 | noreducetemp | no reduce below temperature | int8 (>=-31<=10) | C | True | number.thermostat_hc1_no_reduce_below_temperature | number.thermostat_hc1_noreducetemp | 6 | 1 | 1 | 31 | 1 |
ES79 | thermostat | 156 | reducetemp | off/reduce switch temperature | int8 (>=-20<=10) | C | True | number.thermostat_hc1_off/reduce_switch_temperature | number.thermostat_hc1_reducetemp | 6 | 1 | 1 | 32 | 1 |
ES79 | thermostat | 156 | vacreducetemp | vacations off/reduce switch temperature | int8 (>=-20<=10) | C | True | number.thermostat_hc1_vacations_off/reduce_switch_temperature | number.thermostat_hc1_vacreducetemp | 6 | 1 | 1 | 85 | 1 |
ES79 | thermostat | 156 | vacreducemode | vacations reduce mode | enum [nofrost|reduce|room|outdoor] | | True | select.thermostat_hc1_vacations_reduce_mode | select.thermostat_hc1_vacreducemode | 6 | 1 | 1 | 86 | 1 |
ES79 | thermostat | 156 | remotetemp | room temperature from remote | cmd [] (>=-1<=101) | C | True | sensor.thermostat_hc1_room_temperature_from_remote | sensor.thermostat_hc1_remotetemp | 6 | 1 | 1/10 | 41 | 1 |
ES79 | thermostat | 156 | dhwprio | dhw priority | boolean | | True | switch.thermostat_hc1_dhw_priority | switch.thermostat_hc1_dhwprio | 6 | 1 | 1 | 33 | 1 |
ES79 | thermostat | 156 | switchonoptimization | switch-on optimization | boolean | | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | 6 | 1 | 1 | 29 | 1 |
ES79 | thermostat | 156 | switchtime1 | own1 program switchtime | string | | True | sensor.thermostat_hc1_own1_program_switchtime | sensor.thermostat_hc1_switchtime1 | 6 | 1 | 1 | 87 | 8 |
ES79 | thermostat | 156 | switchtime2 | own2 program switchtime | string | | True | sensor.thermostat_hc1_own2_program_switchtime | sensor.thermostat_hc1_switchtime2 | 6 | 1 | 1 | 95 | 8 |
ES79 | thermostat | 156 | mode | operating mode | enum [off|on|auto] | | True | select.thermostat_dhw_operating_mode | select.thermostat_dhw_mode | 6 | 9 | 1 | 0 | 1 |
ES79 | thermostat | 156 | circmode | circulation pump mode | enum [off|on|auto] | | True | select.thermostat_dhw_circulation_pump_mode | select.thermostat_dhw_circmode | 6 | 9 | 1 | 3 | 1 |
ES79 | thermostat | 156 | progmode | program | enum [std prog|own prog] | | True | select.thermostat_dhw_program | select.thermostat_dhw_progmode | 6 | 9 | 1 | 12 | 1 |
ES79 | thermostat | 156 | circprog | circulation program | enum [std prog|own prog] | | True | select.thermostat_dhw_circulation_program | select.thermostat_dhw_circprog | 6 | 9 | 1 | 13 | 1 |
ES79 | thermostat | 156 | disinfecting | disinfecting | boolean | | True | switch.thermostat_dhw_disinfecting | switch.thermostat_dhw_disinfecting | 6 | 9 | 1 | 7 | 1 |
ES79 | thermostat | 156 | disinfectday | disinfection day | enum [mo|tu|we|th|fr|sa|su|all] | | True | select.thermostat_dhw_disinfection_day | select.thermostat_dhw_disinfectday | 6 | 9 | 1 | 8 | 1 |
ES79 | thermostat | 156 | disinfecthour | disinfection hour | uint8 (>=0<=23) | | True | number.thermostat_dhw_disinfection_hour | number.thermostat_dhw_disinfecthour | 6 | 9 | 1 | 14 | 1 |
ES79 | thermostat | 156 | maxtemp | maximum temperature | uint8 (>=60<=80) | C | True | number.thermostat_dhw_maximum_temperature | number.thermostat_dhw_maxtemp | 6 | 9 | 1 | 15 | 1 |
ES79 | thermostat | 156 | onetimekey | one time key function | boolean | | True | switch.thermostat_dhw_one_time_key_function | switch.thermostat_dhw_onetimekey | 6 | 9 | 1 | 16 | 1 |
ES79 | thermostat | 156 | switchtimeWW | program switchtime warm water | string | | True | sensor.thermostat_dhw_program_switchtime_warm_water | sensor.thermostat_dhw_switchtimeWW | 6 | 9 | 1 | 17 | 11 |
ES79 | thermostat | 156 | circswitchtime | circulation program switchtime | string | | True | sensor.thermostat_dhw_circulation_program_switchtime | sensor.thermostat_dhw_circswitchtime | 6 | 9 | 1 | 28 | 8 |
ES79 | thermostat | 156 | holidays | holiday dates | string | | True | sensor.thermostat_dhw_holiday_dates | sensor.thermostat_dhw_holidays | 6 | 9 | 1 | 36 | 13 |
ES79 | thermostat | 156 | vacations | vacation dates | string | | True | sensor.thermostat_dhw_vacation_dates | sensor.thermostat_dhw_vacations | 6 | 9 | 1 | 49 | 13 |
FW100 | thermostat | 105 | errorcode | error code | string | | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | 6 | 0 | 1 | 0 | 8 |
FW100 | thermostat | 105 | lastcode | last error code | string | | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | 6 | 0 | 1 | 8 | 25 |
FW100 | thermostat | 105 | datetime | date/time | string | | True | sensor.thermostat_date/time | sensor.thermostat_datetime | 6 | 0 | 1 | 33 | 13 |
FW100 | thermostat | 105 | hybridstrategy | hybrid control strategy | enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] | | True | select.thermostat_hybrid_control_strategy | select.thermostat_hybridstrategy | 6 | 0 | 1 | 53 | 1 |
FW100 | thermostat | 105 | switchovertemp | outside switchover temperature | int8 (>=-20<=20) | C | True | number.thermostat_outside_switchover_temperature | number.thermostat_switchovertemp | 6 | 0 | 1 | 54 | 1 |
FW100 | thermostat | 105 | energycostratio | energy cost ratio | uint8 (>=0<=20) | | True | number.thermostat_energy_cost_ratio | number.thermostat_energycostratio | 6 | 0 | 1/10 | 55 | 1 |
FW100 | thermostat | 105 | fossilefactor | fossile energy factor | uint8 (>=0<=5) | | True | number.thermostat_fossile_energy_factor | number.thermostat_fossilefactor | 6 | 0 | 1/10 | 56 | 1 |
FW100 | thermostat | 105 | electricfactor | electric energy factor | uint8 (>=0<=5) | | True | number.thermostat_electric_energy_factor | number.thermostat_electricfactor | 6 | 0 | 1/10 | 57 | 1 |
FW100 | thermostat | 105 | delayboiler | delay boiler support | uint8 (>=5<=120) | minutes | True | number.thermostat_delay_boiler_support | number.thermostat_delayboiler | 6 | 0 | 1 | 58 | 1 |
FW100 | thermostat | 105 | tempdiffboiler | temp diff boiler support | uint8 (>=1<=99) | C | True | number.thermostat_temp_diff_boiler_support | number.thermostat_tempdiffboiler | 6 | 0 | 1 | 59 | 1 |
FW100 | thermostat | 105 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp | 6 | 1 | 1/10 | 0 | 1 |
FW100 | thermostat | 105 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp | 6 | 1 | 1/10 | 1 | 1 |
FW100 | thermostat | 105 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | 6 | 1 | 1 | 2 | 1 |
FW100 | thermostat | 105 | mode | operating mode | enum [nofrost|eco|heat|auto] | | True | select.thermostat_hc1_operating_mode | select.thermostat_hc1_mode | 6 | 1 | 1 | 3 | 1 |
FW100 | thermostat | 105 | modetype | mode type | enum [nofrost|eco|heat] | | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | 6 | 1 | 1 | 4 | 1 |
FW100 | thermostat | 105 | heattemp | heat temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_heat_temperature | number.thermostat_hc1_heattemp | 6 | 1 | 1/2 | 194 | 1 |
FW100 | thermostat | 105 | ecotemp | eco temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_eco_temperature | number.thermostat_hc1_ecotemp | 6 | 1 | 1/2 | 5 | 1 |
FW100 | thermostat | 105 | nofrosttemp | nofrost temperature | int8 (>=-63<=63) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp | 6 | 1 | 1/2 | 17 | 1 |
FW100 | thermostat | 105 | control | control device | enum [off|FB10|FB100] | | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | 6 | 1 | 1 | 40 | 1 |
FW100 | thermostat | 105 | program | program | enum [prog a|prog b|prog c|prog d|prog e|prog f] | | True | select.thermostat_hc1_program | select.thermostat_hc1_program | 6 | 1 | 1 | 25 | 1 |
FW100 | thermostat | 105 | remotetemp | room temperature from remote | cmd [] (>=-1<=101) | C | True | sensor.thermostat_hc1_room_temperature_from_remote | sensor.thermostat_hc1_remotetemp | 6 | 1 | 1/10 | 41 | 1 |
FW100 | thermostat | 105 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp | 6 | 1 | 1 | 18 | 1 |
FW100 | thermostat | 105 | summertemp | summer temperature | uint8 (>=9<=25) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp | 6 | 1 | 1/2 | 8 | 1 |
FW100 | thermostat | 105 | roomsensor | room sensor | enum [extern|intern|auto] | | True | select.thermostat_hc1_room_sensor | select.thermostat_hc1_roomsensor | 6 | 1 | 1 | 195 | 1 |
FW100 | thermostat | 105 | holidaymode | holiday mode | enum [nofrost|eco|heat|auto] | | True | select.thermostat_hc1_holiday_mode | select.thermostat_hc1_holidaymode | 6 | 1 | 1 | 55 | 1 |
FW100 | thermostat | 105 | switchonoptimization | switch-on optimization | boolean | | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | 6 | 1 | 1 | 29 | 1 |
FW100 | thermostat | 105 | heatup | heatup | enum [slow|medium|fast] | | True | select.thermostat_hc1_heatup | select.thermostat_hc1_heatup | 6 | 1 | 1 | 196 | 1 |
FW100 | thermostat | 105 | minflowtemp | min flow temperature | uint8 (>=5<=70) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp | 6 | 1 | 1 | 11 | 1 |
FW100 | thermostat | 105 | maxflowtemp | max flow temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp | 6 | 1 | 1 | 12 | 1 |
FW100 | thermostat | 105 | designtemp | design temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp | 6 | 1 | 1 | 9 | 1 |
FW100 | thermostat | 105 | roominfluence | room influence | enum [off|intern|extern|auto] | | True | select.thermostat_hc1_room_influence | select.thermostat_hc1_roominfluence | 6 | 1 | 1 | 13 | 1 |
FW100 | thermostat | 105 | roominflfactor | room influence factor | uint8 (>=0<=100) | % | True | number.thermostat_hc1_room_influence_factor | number.thermostat_hc1_roominflfactor | 6 | 1 | 10 | 14 | 1 |
FW100 | thermostat | 105 | heatingtype | heating type | enum [off|heatingcurve|radiator|convector|floor] | | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | 6 | 1 | 1 | 19 | 1 |
FW100 | thermostat | 105 | controlmode | control mode | enum [off|unmixed|unmixed IPM|mixed IPM] | | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | 6 | 1 | 1 | 24 | 1 |
FW100 | thermostat | 105 | charge | charge | boolean | | True | switch.thermostat_dhw_charge | switch.thermostat_dhw_charge | 6 | 9 | 1 | 5 | 1 |
FW200 | thermostat | 106 | errorcode | error code | string | | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | 6 | 0 | 1 | 0 | 8 |
FW200 | thermostat | 106 | lastcode | last error code | string | | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | 6 | 0 | 1 | 8 | 25 |
FW200 | thermostat | 106 | datetime | date/time | string | | True | sensor.thermostat_date/time | sensor.thermostat_datetime | 6 | 0 | 1 | 33 | 13 |
FW200 | thermostat | 106 | hybridstrategy | hybrid control strategy | enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] | | True | select.thermostat_hybrid_control_strategy | select.thermostat_hybridstrategy | 6 | 0 | 1 | 53 | 1 |
FW200 | thermostat | 106 | switchovertemp | outside switchover temperature | int8 (>=-20<=20) | C | True | number.thermostat_outside_switchover_temperature | number.thermostat_switchovertemp | 6 | 0 | 1 | 54 | 1 |
FW200 | thermostat | 106 | energycostratio | energy cost ratio | uint8 (>=0<=20) | | True | number.thermostat_energy_cost_ratio | number.thermostat_energycostratio | 6 | 0 | 1/10 | 55 | 1 |
FW200 | thermostat | 106 | fossilefactor | fossile energy factor | uint8 (>=0<=5) | | True | number.thermostat_fossile_energy_factor | number.thermostat_fossilefactor | 6 | 0 | 1/10 | 56 | 1 |
FW200 | thermostat | 106 | electricfactor | electric energy factor | uint8 (>=0<=5) | | True | number.thermostat_electric_energy_factor | number.thermostat_electricfactor | 6 | 0 | 1/10 | 57 | 1 |
FW200 | thermostat | 106 | delayboiler | delay boiler support | uint8 (>=5<=120) | minutes | True | number.thermostat_delay_boiler_support | number.thermostat_delayboiler | 6 | 0 | 1 | 58 | 1 |
FW200 | thermostat | 106 | tempdiffboiler | temp diff boiler support | uint8 (>=1<=99) | C | True | number.thermostat_temp_diff_boiler_support | number.thermostat_tempdiffboiler | 6 | 0 | 1 | 59 | 1 |
FW200 | thermostat | 106 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp | 6 | 1 | 1/10 | 0 | 1 |
FW200 | thermostat | 106 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp | 6 | 1 | 1/10 | 1 | 1 |
FW200 | thermostat | 106 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | 6 | 1 | 1 | 2 | 1 |
FW200 | thermostat | 106 | mode | operating mode | enum [nofrost|eco|heat|auto] | | True | select.thermostat_hc1_operating_mode | select.thermostat_hc1_mode | 6 | 1 | 1 | 3 | 1 |
FW200 | thermostat | 106 | modetype | mode type | enum [nofrost|eco|heat] | | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | 6 | 1 | 1 | 4 | 1 |
FW200 | thermostat | 106 | heattemp | heat temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_heat_temperature | number.thermostat_hc1_heattemp | 6 | 1 | 1/2 | 194 | 1 |
FW200 | thermostat | 106 | ecotemp | eco temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_eco_temperature | number.thermostat_hc1_ecotemp | 6 | 1 | 1/2 | 5 | 1 |
FW200 | thermostat | 106 | nofrosttemp | nofrost temperature | int8 (>=-63<=63) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp | 6 | 1 | 1/2 | 17 | 1 |
FW200 | thermostat | 106 | control | control device | enum [off|FB10|FB100] | | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | 6 | 1 | 1 | 40 | 1 |
FW200 | thermostat | 106 | program | program | enum [prog a|prog b|prog c|prog d|prog e|prog f] | | True | select.thermostat_hc1_program | select.thermostat_hc1_program | 6 | 1 | 1 | 25 | 1 |
FW200 | thermostat | 106 | remotetemp | room temperature from remote | cmd [] (>=-1<=101) | C | True | sensor.thermostat_hc1_room_temperature_from_remote | sensor.thermostat_hc1_remotetemp | 6 | 1 | 1/10 | 41 | 1 |
FW200 | thermostat | 106 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp | 6 | 1 | 1 | 18 | 1 |
FW200 | thermostat | 106 | summertemp | summer temperature | uint8 (>=9<=25) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp | 6 | 1 | 1/2 | 8 | 1 |
FW200 | thermostat | 106 | roomsensor | room sensor | enum [extern|intern|auto] | | True | select.thermostat_hc1_room_sensor | select.thermostat_hc1_roomsensor | 6 | 1 | 1 | 195 | 1 |
FW200 | thermostat | 106 | holidaymode | holiday mode | enum [nofrost|eco|heat|auto] | | True | select.thermostat_hc1_holiday_mode | select.thermostat_hc1_holidaymode | 6 | 1 | 1 | 55 | 1 |
FW200 | thermostat | 106 | switchonoptimization | switch-on optimization | boolean | | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | 6 | 1 | 1 | 29 | 1 |
FW200 | thermostat | 106 | heatup | heatup | enum [slow|medium|fast] | | True | select.thermostat_hc1_heatup | select.thermostat_hc1_heatup | 6 | 1 | 1 | 196 | 1 |
FW200 | thermostat | 106 | minflowtemp | min flow temperature | uint8 (>=5<=70) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp | 6 | 1 | 1 | 11 | 1 |
FW200 | thermostat | 106 | maxflowtemp | max flow temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp | 6 | 1 | 1 | 12 | 1 |
FW200 | thermostat | 106 | designtemp | design temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp | 6 | 1 | 1 | 9 | 1 |
FW200 | thermostat | 106 | roominfluence | room influence | enum [off|intern|extern|auto] | | True | select.thermostat_hc1_room_influence | select.thermostat_hc1_roominfluence | 6 | 1 | 1 | 13 | 1 |
FW200 | thermostat | 106 | roominflfactor | room influence factor | uint8 (>=0<=100) | % | True | number.thermostat_hc1_room_influence_factor | number.thermostat_hc1_roominflfactor | 6 | 1 | 10 | 14 | 1 |
FW200 | thermostat | 106 | heatingtype | heating type | enum [off|heatingcurve|radiator|convector|floor] | | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | 6 | 1 | 1 | 19 | 1 |
FW200 | thermostat | 106 | controlmode | control mode | enum [off|unmixed|unmixed IPM|mixed IPM] | | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | 6 | 1 | 1 | 24 | 1 |
FW200 | thermostat | 106 | charge | charge | boolean | | True | switch.thermostat_dhw_charge | switch.thermostat_dhw_charge | 6 | 9 | 1 | 5 | 1 |
FR100 | thermostat | 107 | errorcode | error code | string | | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | 6 | 0 | 1 | 0 | 8 |
FR100 | thermostat | 107 | lastcode | last error code | string | | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | 6 | 0 | 1 | 8 | 25 |
FR100 | thermostat | 107 | datetime | date/time | string | | False | sensor.thermostat_date/time | sensor.thermostat_datetime | 6 | 0 | 1 | 33 | 13 |
FR100 | thermostat | 107 | hybridstrategy | hybrid control strategy | enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] | | True | select.thermostat_hybrid_control_strategy | select.thermostat_hybridstrategy | 6 | 0 | 1 | 53 | 1 |
FR100 | thermostat | 107 | switchovertemp | outside switchover temperature | int8 (>=-20<=20) | C | True | number.thermostat_outside_switchover_temperature | number.thermostat_switchovertemp | 6 | 0 | 1 | 54 | 1 |
FR100 | thermostat | 107 | energycostratio | energy cost ratio | uint8 (>=0<=20) | | True | number.thermostat_energy_cost_ratio | number.thermostat_energycostratio | 6 | 0 | 1/10 | 55 | 1 |
FR100 | thermostat | 107 | fossilefactor | fossile energy factor | uint8 (>=0<=5) | | True | number.thermostat_fossile_energy_factor | number.thermostat_fossilefactor | 6 | 0 | 1/10 | 56 | 1 |
FR100 | thermostat | 107 | electricfactor | electric energy factor | uint8 (>=0<=5) | | True | number.thermostat_electric_energy_factor | number.thermostat_electricfactor | 6 | 0 | 1/10 | 57 | 1 |
FR100 | thermostat | 107 | delayboiler | delay boiler support | uint8 (>=5<=120) | minutes | True | number.thermostat_delay_boiler_support | number.thermostat_delayboiler | 6 | 0 | 1 | 58 | 1 |
FR100 | thermostat | 107 | tempdiffboiler | temp diff boiler support | uint8 (>=1<=99) | C | True | number.thermostat_temp_diff_boiler_support | number.thermostat_tempdiffboiler | 6 | 0 | 1 | 59 | 1 |
FR100 | thermostat | 107 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp | 6 | 1 | 1/10 | 0 | 1 |
FR100 | thermostat | 107 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp | 6 | 1 | 1/10 | 1 | 1 |
FR100 | thermostat | 107 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | 6 | 1 | 1 | 2 | 1 |
FR100 | thermostat | 107 | mode | operating mode | enum [nofrost|eco|heat|auto] | | True | select.thermostat_hc1_operating_mode | select.thermostat_hc1_mode | 6 | 1 | 1 | 3 | 1 |
FR100 | thermostat | 107 | modetype | mode type | enum [nofrost|eco|heat] | | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | 6 | 1 | 1 | 4 | 1 |
FR100 | thermostat | 107 | heattemp | heat temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_heat_temperature | number.thermostat_hc1_heattemp | 6 | 1 | 1/2 | 194 | 1 |
FR100 | thermostat | 107 | ecotemp | eco temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_eco_temperature | number.thermostat_hc1_ecotemp | 6 | 1 | 1/2 | 5 | 1 |
FR100 | thermostat | 107 | nofrosttemp | nofrost temperature | int8 (>=-63<=63) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp | 6 | 1 | 1/2 | 17 | 1 |
FR100 | thermostat | 107 | control | control device | enum [off|FB10|FB100] | | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | 6 | 1 | 1 | 40 | 1 |
FR100 | thermostat | 107 | program | program | enum [prog a|prog b|prog c|prog d|prog e|prog f] | | True | select.thermostat_hc1_program | select.thermostat_hc1_program | 6 | 1 | 1 | 25 | 1 |
FR100 | thermostat | 107 | remotetemp | room temperature from remote | cmd [] (>=-1<=101) | C | True | sensor.thermostat_hc1_room_temperature_from_remote | sensor.thermostat_hc1_remotetemp | 6 | 1 | 1/10 | 41 | 1 |
FR100 | thermostat | 107 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp | 6 | 1 | 1 | 18 | 1 |
FR100 | thermostat | 107 | summertemp | summer temperature | uint8 (>=9<=25) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp | 6 | 1 | 1/2 | 8 | 1 |
FR100 | thermostat | 107 | roomsensor | room sensor | enum [extern|intern|auto] | | True | select.thermostat_hc1_room_sensor | select.thermostat_hc1_roomsensor | 6 | 1 | 1 | 195 | 1 |
FR100 | thermostat | 107 | holidaymode | holiday mode | enum [nofrost|eco|heat|auto] | | True | select.thermostat_hc1_holiday_mode | select.thermostat_hc1_holidaymode | 6 | 1 | 1 | 55 | 1 |
FR100 | thermostat | 107 | switchonoptimization | switch-on optimization | boolean | | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | 6 | 1 | 1 | 29 | 1 |
FR100 | thermostat | 107 | heatup | heatup | enum [slow|medium|fast] | | True | select.thermostat_hc1_heatup | select.thermostat_hc1_heatup | 6 | 1 | 1 | 196 | 1 |
FR100 | thermostat | 107 | minflowtemp | min flow temperature | uint8 (>=5<=70) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp | 6 | 1 | 1 | 11 | 1 |
FR100 | thermostat | 107 | maxflowtemp | max flow temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp | 6 | 1 | 1 | 12 | 1 |
FR100 | thermostat | 107 | designtemp | design temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp | 6 | 1 | 1 | 9 | 1 |
FR100 | thermostat | 107 | roominfluence | room influence | enum [off|intern|extern|auto] | | True | select.thermostat_hc1_room_influence | select.thermostat_hc1_roominfluence | 6 | 1 | 1 | 13 | 1 |
FR100 | thermostat | 107 | roominflfactor | room influence factor | uint8 (>=0<=100) | % | True | number.thermostat_hc1_room_influence_factor | number.thermostat_hc1_roominflfactor | 6 | 1 | 10 | 14 | 1 |
FR100 | thermostat | 107 | heatingtype | heating type | enum [off|heatingcurve|radiator|convector|floor] | | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | 6 | 1 | 1 | 19 | 1 |
FR100 | thermostat | 107 | controlmode | control mode | enum [off|unmixed|unmixed IPM|mixed IPM] | | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | 6 | 1 | 1 | 24 | 1 |
FR100 | thermostat | 107 | charge | charge | boolean | | True | switch.thermostat_dhw_charge | switch.thermostat_dhw_charge | 6 | 9 | 1 | 5 | 1 |
FR110 | thermostat | 108 | errorcode | error code | string | | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | 6 | 0 | 1 | 0 | 8 |
FR110 | thermostat | 108 | lastcode | last error code | string | | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | 6 | 0 | 1 | 8 | 25 |
FR110 | thermostat | 108 | datetime | date/time | string | | False | sensor.thermostat_date/time | sensor.thermostat_datetime | 6 | 0 | 1 | 33 | 13 |
FR110 | thermostat | 108 | hybridstrategy | hybrid control strategy | enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] | | True | select.thermostat_hybrid_control_strategy | select.thermostat_hybridstrategy | 6 | 0 | 1 | 53 | 1 |
FR110 | thermostat | 108 | switchovertemp | outside switchover temperature | int8 (>=-20<=20) | C | True | number.thermostat_outside_switchover_temperature | number.thermostat_switchovertemp | 6 | 0 | 1 | 54 | 1 |
FR110 | thermostat | 108 | energycostratio | energy cost ratio | uint8 (>=0<=20) | | True | number.thermostat_energy_cost_ratio | number.thermostat_energycostratio | 6 | 0 | 1/10 | 55 | 1 |
FR110 | thermostat | 108 | fossilefactor | fossile energy factor | uint8 (>=0<=5) | | True | number.thermostat_fossile_energy_factor | number.thermostat_fossilefactor | 6 | 0 | 1/10 | 56 | 1 |
FR110 | thermostat | 108 | electricfactor | electric energy factor | uint8 (>=0<=5) | | True | number.thermostat_electric_energy_factor | number.thermostat_electricfactor | 6 | 0 | 1/10 | 57 | 1 |
FR110 | thermostat | 108 | delayboiler | delay boiler support | uint8 (>=5<=120) | minutes | True | number.thermostat_delay_boiler_support | number.thermostat_delayboiler | 6 | 0 | 1 | 58 | 1 |
FR110 | thermostat | 108 | tempdiffboiler | temp diff boiler support | uint8 (>=1<=99) | C | True | number.thermostat_temp_diff_boiler_support | number.thermostat_tempdiffboiler | 6 | 0 | 1 | 59 | 1 |
FR110 | thermostat | 108 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp | 6 | 1 | 1/10 | 0 | 1 |
FR110 | thermostat | 108 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp | 6 | 1 | 1/10 | 1 | 1 |
FR110 | thermostat | 108 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | 6 | 1 | 1 | 2 | 1 |
FR110 | thermostat | 108 | mode | operating mode | enum [nofrost|eco|heat|auto] | | True | select.thermostat_hc1_operating_mode | select.thermostat_hc1_mode | 6 | 1 | 1 | 3 | 1 |
FR110 | thermostat | 108 | modetype | mode type | enum [nofrost|eco|heat] | | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | 6 | 1 | 1 | 4 | 1 |
FR110 | thermostat | 108 | heattemp | heat temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_heat_temperature | number.thermostat_hc1_heattemp | 6 | 1 | 1/2 | 194 | 1 |
FR110 | thermostat | 108 | ecotemp | eco temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_eco_temperature | number.thermostat_hc1_ecotemp | 6 | 1 | 1/2 | 5 | 1 |
FR110 | thermostat | 108 | nofrosttemp | nofrost temperature | int8 (>=-63<=63) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp | 6 | 1 | 1/2 | 17 | 1 |
FR110 | thermostat | 108 | control | control device | enum [off|FB10|FB100] | | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | 6 | 1 | 1 | 40 | 1 |
FR110 | thermostat | 108 | program | program | enum [prog a|prog b|prog c|prog d|prog e|prog f] | | True | select.thermostat_hc1_program | select.thermostat_hc1_program | 6 | 1 | 1 | 25 | 1 |
FR110 | thermostat | 108 | remotetemp | room temperature from remote | cmd [] (>=-1<=101) | C | True | sensor.thermostat_hc1_room_temperature_from_remote | sensor.thermostat_hc1_remotetemp | 6 | 1 | 1/10 | 41 | 1 |
FR110 | thermostat | 108 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp | 6 | 1 | 1 | 18 | 1 |
FR110 | thermostat | 108 | summertemp | summer temperature | uint8 (>=9<=25) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp | 6 | 1 | 1/2 | 8 | 1 |
FR110 | thermostat | 108 | roomsensor | room sensor | enum [extern|intern|auto] | | True | select.thermostat_hc1_room_sensor | select.thermostat_hc1_roomsensor | 6 | 1 | 1 | 195 | 1 |
FR110 | thermostat | 108 | holidaymode | holiday mode | enum [nofrost|eco|heat|auto] | | True | select.thermostat_hc1_holiday_mode | select.thermostat_hc1_holidaymode | 6 | 1 | 1 | 55 | 1 |
FR110 | thermostat | 108 | switchonoptimization | switch-on optimization | boolean | | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | 6 | 1 | 1 | 29 | 1 |
FR110 | thermostat | 108 | heatup | heatup | enum [slow|medium|fast] | | True | select.thermostat_hc1_heatup | select.thermostat_hc1_heatup | 6 | 1 | 1 | 196 | 1 |
FR110 | thermostat | 108 | minflowtemp | min flow temperature | uint8 (>=5<=70) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp | 6 | 1 | 1 | 11 | 1 |
FR110 | thermostat | 108 | maxflowtemp | max flow temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp | 6 | 1 | 1 | 12 | 1 |
FR110 | thermostat | 108 | designtemp | design temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp | 6 | 1 | 1 | 9 | 1 |
FR110 | thermostat | 108 | roominfluence | room influence | enum [off|intern|extern|auto] | | True | select.thermostat_hc1_room_influence | select.thermostat_hc1_roominfluence | 6 | 1 | 1 | 13 | 1 |
FR110 | thermostat | 108 | roominflfactor | room influence factor | uint8 (>=0<=100) | % | True | number.thermostat_hc1_room_influence_factor | number.thermostat_hc1_roominflfactor | 6 | 1 | 10 | 14 | 1 |
FR110 | thermostat | 108 | heatingtype | heating type | enum [off|heatingcurve|radiator|convector|floor] | | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | 6 | 1 | 1 | 19 | 1 |
FR110 | thermostat | 108 | controlmode | control mode | enum [off|unmixed|unmixed IPM|mixed IPM] | | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | 6 | 1 | 1 | 24 | 1 |
FR110 | thermostat | 108 | charge | charge | boolean | | True | switch.thermostat_dhw_charge | switch.thermostat_dhw_charge | 6 | 9 | 1 | 5 | 1 |
FB10 | thermostat | 109 | errorcode | error code | string | | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | 6 | 0 | 1 | 0 | 8 |
FB10 | thermostat | 109 | lastcode | last error code | string | | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | 6 | 0 | 1 | 8 | 25 |
FB10 | thermostat | 109 | datetime | date/time | string | | True | sensor.thermostat_date/time | sensor.thermostat_datetime | 6 | 0 | 1 | 33 | 13 |
FB10 | thermostat | 109 | hybridstrategy | hybrid control strategy | enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] | | True | select.thermostat_hybrid_control_strategy | select.thermostat_hybridstrategy | 6 | 0 | 1 | 53 | 1 |
FB10 | thermostat | 109 | switchovertemp | outside switchover temperature | int8 (>=-20<=20) | C | True | number.thermostat_outside_switchover_temperature | number.thermostat_switchovertemp | 6 | 0 | 1 | 54 | 1 |
FB10 | thermostat | 109 | energycostratio | energy cost ratio | uint8 (>=0<=20) | | True | number.thermostat_energy_cost_ratio | number.thermostat_energycostratio | 6 | 0 | 1/10 | 55 | 1 |
FB10 | thermostat | 109 | fossilefactor | fossile energy factor | uint8 (>=0<=5) | | True | number.thermostat_fossile_energy_factor | number.thermostat_fossilefactor | 6 | 0 | 1/10 | 56 | 1 |
FB10 | thermostat | 109 | electricfactor | electric energy factor | uint8 (>=0<=5) | | True | number.thermostat_electric_energy_factor | number.thermostat_electricfactor | 6 | 0 | 1/10 | 57 | 1 |
FB10 | thermostat | 109 | delayboiler | delay boiler support | uint8 (>=5<=120) | minutes | True | number.thermostat_delay_boiler_support | number.thermostat_delayboiler | 6 | 0 | 1 | 58 | 1 |
FB10 | thermostat | 109 | tempdiffboiler | temp diff boiler support | uint8 (>=1<=99) | C | True | number.thermostat_temp_diff_boiler_support | number.thermostat_tempdiffboiler | 6 | 0 | 1 | 59 | 1 |
FB10 | thermostat | 109 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp | 6 | 1 | 1/10 | 0 | 1 |
FB10 | thermostat | 109 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp | 6 | 1 | 1/10 | 1 | 1 |
FB10 | thermostat | 109 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | 6 | 1 | 1 | 2 | 1 |
FB10 | thermostat | 109 | mode | operating mode | enum [nofrost|eco|heat|auto] | | True | select.thermostat_hc1_operating_mode | select.thermostat_hc1_mode | 6 | 1 | 1 | 3 | 1 |
FB10 | thermostat | 109 | modetype | mode type | enum [nofrost|eco|heat] | | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | 6 | 1 | 1 | 4 | 1 |
FB10 | thermostat | 109 | heattemp | heat temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_heat_temperature | number.thermostat_hc1_heattemp | 6 | 1 | 1/2 | 194 | 1 |
FB10 | thermostat | 109 | ecotemp | eco temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_eco_temperature | number.thermostat_hc1_ecotemp | 6 | 1 | 1/2 | 5 | 1 |
FB10 | thermostat | 109 | nofrosttemp | nofrost temperature | int8 (>=-63<=63) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp | 6 | 1 | 1/2 | 17 | 1 |
FB10 | thermostat | 109 | control | control device | enum [off|FB10|FB100] | | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | 6 | 1 | 1 | 40 | 1 |
FB10 | thermostat | 109 | program | program | enum [prog a|prog b|prog c|prog d|prog e|prog f] | | True | select.thermostat_hc1_program | select.thermostat_hc1_program | 6 | 1 | 1 | 25 | 1 |
FB10 | thermostat | 109 | remotetemp | room temperature from remote | cmd [] (>=-1<=101) | C | True | sensor.thermostat_hc1_room_temperature_from_remote | sensor.thermostat_hc1_remotetemp | 6 | 1 | 1/10 | 41 | 1 |
FB10 | thermostat | 109 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp | 6 | 1 | 1 | 18 | 1 |
FB10 | thermostat | 109 | summertemp | summer temperature | uint8 (>=9<=25) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp | 6 | 1 | 1/2 | 8 | 1 |
FB10 | thermostat | 109 | roomsensor | room sensor | enum [extern|intern|auto] | | True | select.thermostat_hc1_room_sensor | select.thermostat_hc1_roomsensor | 6 | 1 | 1 | 195 | 1 |
FB10 | thermostat | 109 | holidaymode | holiday mode | enum [nofrost|eco|heat|auto] | | True | select.thermostat_hc1_holiday_mode | select.thermostat_hc1_holidaymode | 6 | 1 | 1 | 55 | 1 |
FB10 | thermostat | 109 | switchonoptimization | switch-on optimization | boolean | | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | 6 | 1 | 1 | 29 | 1 |
FB10 | thermostat | 109 | heatup | heatup | enum [slow|medium|fast] | | True | select.thermostat_hc1_heatup | select.thermostat_hc1_heatup | 6 | 1 | 1 | 196 | 1 |
FB10 | thermostat | 109 | minflowtemp | min flow temperature | uint8 (>=5<=70) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp | 6 | 1 | 1 | 11 | 1 |
FB10 | thermostat | 109 | maxflowtemp | max flow temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp | 6 | 1 | 1 | 12 | 1 |
FB10 | thermostat | 109 | designtemp | design temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp | 6 | 1 | 1 | 9 | 1 |
FB10 | thermostat | 109 | roominfluence | room influence | enum [off|intern|extern|auto] | | True | select.thermostat_hc1_room_influence | select.thermostat_hc1_roominfluence | 6 | 1 | 1 | 13 | 1 |
FB10 | thermostat | 109 | roominflfactor | room influence factor | uint8 (>=0<=100) | % | True | number.thermostat_hc1_room_influence_factor | number.thermostat_hc1_roominflfactor | 6 | 1 | 10 | 14 | 1 |
FB10 | thermostat | 109 | heatingtype | heating type | enum [off|heatingcurve|radiator|convector|floor] | | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | 6 | 1 | 1 | 19 | 1 |
FB10 | thermostat | 109 | controlmode | control mode | enum [off|unmixed|unmixed IPM|mixed IPM] | | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | 6 | 1 | 1 | 24 | 1 |
FB10 | thermostat | 109 | charge | charge | boolean | | True | switch.thermostat_dhw_charge | switch.thermostat_dhw_charge | 6 | 9 | 1 | 5 | 1 |
FB100 | thermostat | 110 | errorcode | error code | string | | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | 6 | 0 | 1 | 0 | 8 |
FB100 | thermostat | 110 | lastcode | last error code | string | | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | 6 | 0 | 1 | 8 | 25 |
FB100 | thermostat | 110 | datetime | date/time | string | | True | sensor.thermostat_date/time | sensor.thermostat_datetime | 6 | 0 | 1 | 33 | 13 |
FB100 | thermostat | 110 | hybridstrategy | hybrid control strategy | enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] | | True | select.thermostat_hybrid_control_strategy | select.thermostat_hybridstrategy | 6 | 0 | 1 | 53 | 1 |
FB100 | thermostat | 110 | switchovertemp | outside switchover temperature | int8 (>=-20<=20) | C | True | number.thermostat_outside_switchover_temperature | number.thermostat_switchovertemp | 6 | 0 | 1 | 54 | 1 |
FB100 | thermostat | 110 | energycostratio | energy cost ratio | uint8 (>=0<=20) | | True | number.thermostat_energy_cost_ratio | number.thermostat_energycostratio | 6 | 0 | 1/10 | 55 | 1 |
FB100 | thermostat | 110 | fossilefactor | fossile energy factor | uint8 (>=0<=5) | | True | number.thermostat_fossile_energy_factor | number.thermostat_fossilefactor | 6 | 0 | 1/10 | 56 | 1 |
FB100 | thermostat | 110 | electricfactor | electric energy factor | uint8 (>=0<=5) | | True | number.thermostat_electric_energy_factor | number.thermostat_electricfactor | 6 | 0 | 1/10 | 57 | 1 |
FB100 | thermostat | 110 | delayboiler | delay boiler support | uint8 (>=5<=120) | minutes | True | number.thermostat_delay_boiler_support | number.thermostat_delayboiler | 6 | 0 | 1 | 58 | 1 |
FB100 | thermostat | 110 | tempdiffboiler | temp diff boiler support | uint8 (>=1<=99) | C | True | number.thermostat_temp_diff_boiler_support | number.thermostat_tempdiffboiler | 6 | 0 | 1 | 59 | 1 |
FB100 | thermostat | 110 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp | 6 | 1 | 1/10 | 0 | 1 |
FB100 | thermostat | 110 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp | 6 | 1 | 1/10 | 1 | 1 |
FB100 | thermostat | 110 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | 6 | 1 | 1 | 2 | 1 |
FB100 | thermostat | 110 | mode | operating mode | enum [nofrost|eco|heat|auto] | | True | select.thermostat_hc1_operating_mode | select.thermostat_hc1_mode | 6 | 1 | 1 | 3 | 1 |
FB100 | thermostat | 110 | modetype | mode type | enum [nofrost|eco|heat] | | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | 6 | 1 | 1 | 4 | 1 |
FB100 | thermostat | 110 | heattemp | heat temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_heat_temperature | number.thermostat_hc1_heattemp | 6 | 1 | 1/2 | 194 | 1 |
FB100 | thermostat | 110 | ecotemp | eco temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_eco_temperature | number.thermostat_hc1_ecotemp | 6 | 1 | 1/2 | 5 | 1 |
FB100 | thermostat | 110 | nofrosttemp | nofrost temperature | int8 (>=-63<=63) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp | 6 | 1 | 1/2 | 17 | 1 |
FB100 | thermostat | 110 | control | control device | enum [off|FB10|FB100] | | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | 6 | 1 | 1 | 40 | 1 |
FB100 | thermostat | 110 | program | program | enum [prog a|prog b|prog c|prog d|prog e|prog f] | | True | select.thermostat_hc1_program | select.thermostat_hc1_program | 6 | 1 | 1 | 25 | 1 |
FB100 | thermostat | 110 | remotetemp | room temperature from remote | cmd [] (>=-1<=101) | C | True | sensor.thermostat_hc1_room_temperature_from_remote | sensor.thermostat_hc1_remotetemp | 6 | 1 | 1/10 | 41 | 1 |
FB100 | thermostat | 110 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp | 6 | 1 | 1 | 18 | 1 |
FB100 | thermostat | 110 | summertemp | summer temperature | uint8 (>=9<=25) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp | 6 | 1 | 1/2 | 8 | 1 |
FB100 | thermostat | 110 | roomsensor | room sensor | enum [extern|intern|auto] | | True | select.thermostat_hc1_room_sensor | select.thermostat_hc1_roomsensor | 6 | 1 | 1 | 195 | 1 |
FB100 | thermostat | 110 | holidaymode | holiday mode | enum [nofrost|eco|heat|auto] | | True | select.thermostat_hc1_holiday_mode | select.thermostat_hc1_holidaymode | 6 | 1 | 1 | 55 | 1 |
FB100 | thermostat | 110 | switchonoptimization | switch-on optimization | boolean | | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | 6 | 1 | 1 | 29 | 1 |
FB100 | thermostat | 110 | heatup | heatup | enum [slow|medium|fast] | | True | select.thermostat_hc1_heatup | select.thermostat_hc1_heatup | 6 | 1 | 1 | 196 | 1 |
FB100 | thermostat | 110 | minflowtemp | min flow temperature | uint8 (>=5<=70) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp | 6 | 1 | 1 | 11 | 1 |
FB100 | thermostat | 110 | maxflowtemp | max flow temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp | 6 | 1 | 1 | 12 | 1 |
FB100 | thermostat | 110 | designtemp | design temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp | 6 | 1 | 1 | 9 | 1 |
FB100 | thermostat | 110 | roominfluence | room influence | enum [off|intern|extern|auto] | | True | select.thermostat_hc1_room_influence | select.thermostat_hc1_roominfluence | 6 | 1 | 1 | 13 | 1 |
FB100 | thermostat | 110 | roominflfactor | room influence factor | uint8 (>=0<=100) | % | True | number.thermostat_hc1_room_influence_factor | number.thermostat_hc1_roominflfactor | 6 | 1 | 10 | 14 | 1 |
FB100 | thermostat | 110 | heatingtype | heating type | enum [off|heatingcurve|radiator|convector|floor] | | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | 6 | 1 | 1 | 19 | 1 |
FB100 | thermostat | 110 | controlmode | control mode | enum [off|unmixed|unmixed IPM|mixed IPM] | | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | 6 | 1 | 1 | 24 | 1 |
FB100 | thermostat | 110 | charge | charge | boolean | | True | switch.thermostat_dhw_charge | switch.thermostat_dhw_charge | 6 | 9 | 1 | 5 | 1 |
FR10 | thermostat | 111 | errorcode | error code | string | | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | 6 | 0 | 1 | 0 | 8 |
FR10 | thermostat | 111 | lastcode | last error code | string | | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | 6 | 0 | 1 | 8 | 25 |
FR10 | thermostat | 111 | datetime | date/time | string | | False | sensor.thermostat_date/time | sensor.thermostat_datetime | 6 | 0 | 1 | 33 | 13 |
FR10 | thermostat | 111 | hybridstrategy | hybrid control strategy | enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] | | True | select.thermostat_hybrid_control_strategy | select.thermostat_hybridstrategy | 6 | 0 | 1 | 53 | 1 |
FR10 | thermostat | 111 | switchovertemp | outside switchover temperature | int8 (>=-20<=20) | C | True | number.thermostat_outside_switchover_temperature | number.thermostat_switchovertemp | 6 | 0 | 1 | 54 | 1 |
FR10 | thermostat | 111 | energycostratio | energy cost ratio | uint8 (>=0<=20) | | True | number.thermostat_energy_cost_ratio | number.thermostat_energycostratio | 6 | 0 | 1/10 | 55 | 1 |
FR10 | thermostat | 111 | fossilefactor | fossile energy factor | uint8 (>=0<=5) | | True | number.thermostat_fossile_energy_factor | number.thermostat_fossilefactor | 6 | 0 | 1/10 | 56 | 1 |
FR10 | thermostat | 111 | electricfactor | electric energy factor | uint8 (>=0<=5) | | True | number.thermostat_electric_energy_factor | number.thermostat_electricfactor | 6 | 0 | 1/10 | 57 | 1 |
FR10 | thermostat | 111 | delayboiler | delay boiler support | uint8 (>=5<=120) | minutes | True | number.thermostat_delay_boiler_support | number.thermostat_delayboiler | 6 | 0 | 1 | 58 | 1 |
FR10 | thermostat | 111 | tempdiffboiler | temp diff boiler support | uint8 (>=1<=99) | C | True | number.thermostat_temp_diff_boiler_support | number.thermostat_tempdiffboiler | 6 | 0 | 1 | 59 | 1 |
FR10 | thermostat | 111 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp | 6 | 1 | 1/10 | 0 | 1 |
FR10 | thermostat | 111 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp | 6 | 1 | 1/10 | 1 | 1 |
FR10 | thermostat | 111 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | 6 | 1 | 1 | 2 | 1 |
FR10 | thermostat | 111 | mode | operating mode | enum [nofrost|eco|heat|auto] | | True | select.thermostat_hc1_operating_mode | select.thermostat_hc1_mode | 6 | 1 | 1 | 3 | 1 |
FR10 | thermostat | 111 | modetype | mode type | enum [nofrost|eco|heat] | | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | 6 | 1 | 1 | 4 | 1 |
FR10 | thermostat | 111 | heattemp | heat temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_heat_temperature | number.thermostat_hc1_heattemp | 6 | 1 | 1/2 | 194 | 1 |
FR10 | thermostat | 111 | ecotemp | eco temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_eco_temperature | number.thermostat_hc1_ecotemp | 6 | 1 | 1/2 | 5 | 1 |
FR10 | thermostat | 111 | nofrosttemp | nofrost temperature | int8 (>=-63<=63) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp | 6 | 1 | 1/2 | 17 | 1 |
FR10 | thermostat | 111 | control | control device | enum [off|FB10|FB100] | | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | 6 | 1 | 1 | 40 | 1 |
FR10 | thermostat | 111 | program | program | enum [prog a|prog b|prog c|prog d|prog e|prog f] | | True | select.thermostat_hc1_program | select.thermostat_hc1_program | 6 | 1 | 1 | 25 | 1 |
FR10 | thermostat | 111 | remotetemp | room temperature from remote | cmd [] (>=-1<=101) | C | True | sensor.thermostat_hc1_room_temperature_from_remote | sensor.thermostat_hc1_remotetemp | 6 | 1 | 1/10 | 41 | 1 |
FR10 | thermostat | 111 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp | 6 | 1 | 1 | 18 | 1 |
FR10 | thermostat | 111 | summertemp | summer temperature | uint8 (>=9<=25) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp | 6 | 1 | 1/2 | 8 | 1 |
FR10 | thermostat | 111 | roomsensor | room sensor | enum [extern|intern|auto] | | True | select.thermostat_hc1_room_sensor | select.thermostat_hc1_roomsensor | 6 | 1 | 1 | 195 | 1 |
FR10 | thermostat | 111 | holidaymode | holiday mode | enum [nofrost|eco|heat|auto] | | True | select.thermostat_hc1_holiday_mode | select.thermostat_hc1_holidaymode | 6 | 1 | 1 | 55 | 1 |
FR10 | thermostat | 111 | switchonoptimization | switch-on optimization | boolean | | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | 6 | 1 | 1 | 29 | 1 |
FR10 | thermostat | 111 | heatup | heatup | enum [slow|medium|fast] | | True | select.thermostat_hc1_heatup | select.thermostat_hc1_heatup | 6 | 1 | 1 | 196 | 1 |
FR10 | thermostat | 111 | minflowtemp | min flow temperature | uint8 (>=5<=70) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp | 6 | 1 | 1 | 11 | 1 |
FR10 | thermostat | 111 | maxflowtemp | max flow temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp | 6 | 1 | 1 | 12 | 1 |
FR10 | thermostat | 111 | designtemp | design temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp | 6 | 1 | 1 | 9 | 1 |
FR10 | thermostat | 111 | roominfluence | room influence | enum [off|intern|extern|auto] | | True | select.thermostat_hc1_room_influence | select.thermostat_hc1_roominfluence | 6 | 1 | 1 | 13 | 1 |
FR10 | thermostat | 111 | roominflfactor | room influence factor | uint8 (>=0<=100) | % | True | number.thermostat_hc1_room_influence_factor | number.thermostat_hc1_roominflfactor | 6 | 1 | 10 | 14 | 1 |
FR10 | thermostat | 111 | heatingtype | heating type | enum [off|heatingcurve|radiator|convector|floor] | | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | 6 | 1 | 1 | 19 | 1 |
FR10 | thermostat | 111 | controlmode | control mode | enum [off|unmixed|unmixed IPM|mixed IPM] | | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | 6 | 1 | 1 | 24 | 1 |
FR10 | thermostat | 111 | charge | charge | boolean | | True | switch.thermostat_dhw_charge | switch.thermostat_dhw_charge | 6 | 9 | 1 | 5 | 1 |
FW500 | thermostat | 116 | errorcode | error code | string | | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | 6 | 0 | 1 | 0 | 8 |
FW500 | thermostat | 116 | lastcode | last error code | string | | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | 6 | 0 | 1 | 8 | 25 |
FW500 | thermostat | 116 | datetime | date/time | string | | True | sensor.thermostat_date/time | sensor.thermostat_datetime | 6 | 0 | 1 | 33 | 13 |
FW500 | thermostat | 116 | hybridstrategy | hybrid control strategy | enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] | | True | select.thermostat_hybrid_control_strategy | select.thermostat_hybridstrategy | 6 | 0 | 1 | 53 | 1 |
FW500 | thermostat | 116 | switchovertemp | outside switchover temperature | int8 (>=-20<=20) | C | True | number.thermostat_outside_switchover_temperature | number.thermostat_switchovertemp | 6 | 0 | 1 | 54 | 1 |
FW500 | thermostat | 116 | energycostratio | energy cost ratio | uint8 (>=0<=20) | | True | number.thermostat_energy_cost_ratio | number.thermostat_energycostratio | 6 | 0 | 1/10 | 55 | 1 |
FW500 | thermostat | 116 | fossilefactor | fossile energy factor | uint8 (>=0<=5) | | True | number.thermostat_fossile_energy_factor | number.thermostat_fossilefactor | 6 | 0 | 1/10 | 56 | 1 |
FW500 | thermostat | 116 | electricfactor | electric energy factor | uint8 (>=0<=5) | | True | number.thermostat_electric_energy_factor | number.thermostat_electricfactor | 6 | 0 | 1/10 | 57 | 1 |
FW500 | thermostat | 116 | delayboiler | delay boiler support | uint8 (>=5<=120) | minutes | True | number.thermostat_delay_boiler_support | number.thermostat_delayboiler | 6 | 0 | 1 | 58 | 1 |
FW500 | thermostat | 116 | tempdiffboiler | temp diff boiler support | uint8 (>=1<=99) | C | True | number.thermostat_temp_diff_boiler_support | number.thermostat_tempdiffboiler | 6 | 0 | 1 | 59 | 1 |
FW500 | thermostat | 116 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp | 6 | 1 | 1/10 | 0 | 1 |
FW500 | thermostat | 116 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp | 6 | 1 | 1/10 | 1 | 1 |
FW500 | thermostat | 116 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | 6 | 1 | 1 | 2 | 1 |
FW500 | thermostat | 116 | mode | operating mode | enum [nofrost|eco|heat|auto] | | True | select.thermostat_hc1_operating_mode | select.thermostat_hc1_mode | 6 | 1 | 1 | 3 | 1 |
FW500 | thermostat | 116 | modetype | mode type | enum [nofrost|eco|heat] | | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | 6 | 1 | 1 | 4 | 1 |
FW500 | thermostat | 116 | heattemp | heat temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_heat_temperature | number.thermostat_hc1_heattemp | 6 | 1 | 1/2 | 194 | 1 |
FW500 | thermostat | 116 | ecotemp | eco temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_eco_temperature | number.thermostat_hc1_ecotemp | 6 | 1 | 1/2 | 5 | 1 |
FW500 | thermostat | 116 | nofrosttemp | nofrost temperature | int8 (>=-63<=63) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp | 6 | 1 | 1/2 | 17 | 1 |
FW500 | thermostat | 116 | control | control device | enum [off|FB10|FB100] | | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | 6 | 1 | 1 | 40 | 1 |
FW500 | thermostat | 116 | program | program | enum [prog a|prog b|prog c|prog d|prog e|prog f] | | True | select.thermostat_hc1_program | select.thermostat_hc1_program | 6 | 1 | 1 | 25 | 1 |
FW500 | thermostat | 116 | remotetemp | room temperature from remote | cmd [] (>=-1<=101) | C | True | sensor.thermostat_hc1_room_temperature_from_remote | sensor.thermostat_hc1_remotetemp | 6 | 1 | 1/10 | 41 | 1 |
FW500 | thermostat | 116 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp | 6 | 1 | 1 | 18 | 1 |
FW500 | thermostat | 116 | summertemp | summer temperature | uint8 (>=9<=25) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp | 6 | 1 | 1/2 | 8 | 1 |
FW500 | thermostat | 116 | roomsensor | room sensor | enum [extern|intern|auto] | | True | select.thermostat_hc1_room_sensor | select.thermostat_hc1_roomsensor | 6 | 1 | 1 | 195 | 1 |
FW500 | thermostat | 116 | holidaymode | holiday mode | enum [nofrost|eco|heat|auto] | | True | select.thermostat_hc1_holiday_mode | select.thermostat_hc1_holidaymode | 6 | 1 | 1 | 55 | 1 |
FW500 | thermostat | 116 | switchonoptimization | switch-on optimization | boolean | | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | 6 | 1 | 1 | 29 | 1 |
FW500 | thermostat | 116 | heatup | heatup | enum [slow|medium|fast] | | True | select.thermostat_hc1_heatup | select.thermostat_hc1_heatup | 6 | 1 | 1 | 196 | 1 |
FW500 | thermostat | 116 | minflowtemp | min flow temperature | uint8 (>=5<=70) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp | 6 | 1 | 1 | 11 | 1 |
FW500 | thermostat | 116 | maxflowtemp | max flow temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp | 6 | 1 | 1 | 12 | 1 |
FW500 | thermostat | 116 | designtemp | design temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp | 6 | 1 | 1 | 9 | 1 |
FW500 | thermostat | 116 | roominfluence | room influence | enum [off|intern|extern|auto] | | True | select.thermostat_hc1_room_influence | select.thermostat_hc1_roominfluence | 6 | 1 | 1 | 13 | 1 |
FW500 | thermostat | 116 | roominflfactor | room influence factor | uint8 (>=0<=100) | % | True | number.thermostat_hc1_room_influence_factor | number.thermostat_hc1_roominflfactor | 6 | 1 | 10 | 14 | 1 |
FW500 | thermostat | 116 | heatingtype | heating type | enum [off|heatingcurve|radiator|convector|floor] | | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | 6 | 1 | 1 | 19 | 1 |
FW500 | thermostat | 116 | controlmode | control mode | enum [off|unmixed|unmixed IPM|mixed IPM] | | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | 6 | 1 | 1 | 24 | 1 |
FW500 | thermostat | 116 | charge | charge | boolean | | True | switch.thermostat_dhw_charge | switch.thermostat_dhw_charge | 6 | 9 | 1 | 5 | 1 |
FR50 | thermostat | 147 | errorcode | error code | string | | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | 6 | 0 | 1 | 0 | 8 |
FR50 | thermostat | 147 | lastcode | last error code | string | | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | 6 | 0 | 1 | 8 | 25 |
FR50 | thermostat | 147 | datetime | date/time | string | | False | sensor.thermostat_date/time | sensor.thermostat_datetime | 6 | 0 | 1 | 33 | 13 |
FR50 | thermostat | 147 | hybridstrategy | hybrid control strategy | enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] | | True | select.thermostat_hybrid_control_strategy | select.thermostat_hybridstrategy | 6 | 0 | 1 | 53 | 1 |
FR50 | thermostat | 147 | switchovertemp | outside switchover temperature | int8 (>=-20<=20) | C | True | number.thermostat_outside_switchover_temperature | number.thermostat_switchovertemp | 6 | 0 | 1 | 54 | 1 |
FR50 | thermostat | 147 | energycostratio | energy cost ratio | uint8 (>=0<=20) | | True | number.thermostat_energy_cost_ratio | number.thermostat_energycostratio | 6 | 0 | 1/10 | 55 | 1 |
FR50 | thermostat | 147 | fossilefactor | fossile energy factor | uint8 (>=0<=5) | | True | number.thermostat_fossile_energy_factor | number.thermostat_fossilefactor | 6 | 0 | 1/10 | 56 | 1 |
FR50 | thermostat | 147 | electricfactor | electric energy factor | uint8 (>=0<=5) | | True | number.thermostat_electric_energy_factor | number.thermostat_electricfactor | 6 | 0 | 1/10 | 57 | 1 |
FR50 | thermostat | 147 | delayboiler | delay boiler support | uint8 (>=5<=120) | minutes | True | number.thermostat_delay_boiler_support | number.thermostat_delayboiler | 6 | 0 | 1 | 58 | 1 |
FR50 | thermostat | 147 | tempdiffboiler | temp diff boiler support | uint8 (>=1<=99) | C | True | number.thermostat_temp_diff_boiler_support | number.thermostat_tempdiffboiler | 6 | 0 | 1 | 59 | 1 |
FR50 | thermostat | 147 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp | 6 | 1 | 1/10 | 0 | 1 |
FR50 | thermostat | 147 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp | 6 | 1 | 1/10 | 1 | 1 |
FR50 | thermostat | 147 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | 6 | 1 | 1 | 2 | 1 |
FR50 | thermostat | 147 | mode | operating mode | enum [nofrost|eco|heat|auto] | | True | select.thermostat_hc1_operating_mode | select.thermostat_hc1_mode | 6 | 1 | 1 | 3 | 1 |
FR50 | thermostat | 147 | modetype | mode type | enum [nofrost|eco|heat] | | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | 6 | 1 | 1 | 4 | 1 |
FR50 | thermostat | 147 | heattemp | heat temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_heat_temperature | number.thermostat_hc1_heattemp | 6 | 1 | 1/2 | 194 | 1 |
FR50 | thermostat | 147 | ecotemp | eco temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_eco_temperature | number.thermostat_hc1_ecotemp | 6 | 1 | 1/2 | 5 | 1 |
FR50 | thermostat | 147 | nofrosttemp | nofrost temperature | int8 (>=-63<=63) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp | 6 | 1 | 1/2 | 17 | 1 |
FR50 | thermostat | 147 | control | control device | enum [off|FB10|FB100] | | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | 6 | 1 | 1 | 40 | 1 |
FR50 | thermostat | 147 | program | program | enum [prog a|prog b|prog c|prog d|prog e|prog f] | | True | select.thermostat_hc1_program | select.thermostat_hc1_program | 6 | 1 | 1 | 25 | 1 |
FR50 | thermostat | 147 | remotetemp | room temperature from remote | cmd [] (>=-1<=101) | C | True | sensor.thermostat_hc1_room_temperature_from_remote | sensor.thermostat_hc1_remotetemp | 6 | 1 | 1/10 | 41 | 1 |
FR50 | thermostat | 147 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp | 6 | 1 | 1 | 18 | 1 |
FR50 | thermostat | 147 | summertemp | summer temperature | uint8 (>=9<=25) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp | 6 | 1 | 1/2 | 8 | 1 |
FR50 | thermostat | 147 | roomsensor | room sensor | enum [extern|intern|auto] | | True | select.thermostat_hc1_room_sensor | select.thermostat_hc1_roomsensor | 6 | 1 | 1 | 195 | 1 |
FR50 | thermostat | 147 | holidaymode | holiday mode | enum [nofrost|eco|heat|auto] | | True | select.thermostat_hc1_holiday_mode | select.thermostat_hc1_holidaymode | 6 | 1 | 1 | 55 | 1 |
FR50 | thermostat | 147 | switchonoptimization | switch-on optimization | boolean | | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | 6 | 1 | 1 | 29 | 1 |
FR50 | thermostat | 147 | heatup | heatup | enum [slow|medium|fast] | | True | select.thermostat_hc1_heatup | select.thermostat_hc1_heatup | 6 | 1 | 1 | 196 | 1 |
FR50 | thermostat | 147 | minflowtemp | min flow temperature | uint8 (>=5<=70) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp | 6 | 1 | 1 | 11 | 1 |
FR50 | thermostat | 147 | maxflowtemp | max flow temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp | 6 | 1 | 1 | 12 | 1 |
FR50 | thermostat | 147 | designtemp | design temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp | 6 | 1 | 1 | 9 | 1 |
FR50 | thermostat | 147 | roominfluence | room influence | enum [off|intern|extern|auto] | | True | select.thermostat_hc1_room_influence | select.thermostat_hc1_roominfluence | 6 | 1 | 1 | 13 | 1 |
FR50 | thermostat | 147 | roominflfactor | room influence factor | uint8 (>=0<=100) | % | True | number.thermostat_hc1_room_influence_factor | number.thermostat_hc1_roominflfactor | 6 | 1 | 10 | 14 | 1 |
FR50 | thermostat | 147 | heatingtype | heating type | enum [off|heatingcurve|radiator|convector|floor] | | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | 6 | 1 | 1 | 19 | 1 |
FR50 | thermostat | 147 | controlmode | control mode | enum [off|unmixed|unmixed IPM|mixed IPM] | | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | 6 | 1 | 1 | 24 | 1 |
FR50 | thermostat | 147 | charge | charge | boolean | | True | switch.thermostat_dhw_charge | switch.thermostat_dhw_charge | 6 | 9 | 1 | 5 | 1 |
FR120 | thermostat | 191 | errorcode | error code | string | | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | 6 | 0 | 1 | 0 | 8 |
FR120 | thermostat | 191 | lastcode | last error code | string | | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | 6 | 0 | 1 | 8 | 25 |
FR120 | thermostat | 191 | datetime | date/time | string | | False | sensor.thermostat_date/time | sensor.thermostat_datetime | 6 | 0 | 1 | 33 | 13 |
FR120 | thermostat | 191 | hybridstrategy | hybrid control strategy | enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] | | True | select.thermostat_hybrid_control_strategy | select.thermostat_hybridstrategy | 6 | 0 | 1 | 53 | 1 |
FR120 | thermostat | 191 | switchovertemp | outside switchover temperature | int8 (>=-20<=20) | C | True | number.thermostat_outside_switchover_temperature | number.thermostat_switchovertemp | 6 | 0 | 1 | 54 | 1 |
FR120 | thermostat | 191 | energycostratio | energy cost ratio | uint8 (>=0<=20) | | True | number.thermostat_energy_cost_ratio | number.thermostat_energycostratio | 6 | 0 | 1/10 | 55 | 1 |
FR120 | thermostat | 191 | fossilefactor | fossile energy factor | uint8 (>=0<=5) | | True | number.thermostat_fossile_energy_factor | number.thermostat_fossilefactor | 6 | 0 | 1/10 | 56 | 1 |
FR120 | thermostat | 191 | electricfactor | electric energy factor | uint8 (>=0<=5) | | True | number.thermostat_electric_energy_factor | number.thermostat_electricfactor | 6 | 0 | 1/10 | 57 | 1 |
FR120 | thermostat | 191 | delayboiler | delay boiler support | uint8 (>=5<=120) | minutes | True | number.thermostat_delay_boiler_support | number.thermostat_delayboiler | 6 | 0 | 1 | 58 | 1 |
FR120 | thermostat | 191 | tempdiffboiler | temp diff boiler support | uint8 (>=1<=99) | C | True | number.thermostat_temp_diff_boiler_support | number.thermostat_tempdiffboiler | 6 | 0 | 1 | 59 | 1 |
FR120 | thermostat | 191 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp | 6 | 1 | 1/10 | 0 | 1 |
FR120 | thermostat | 191 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp | 6 | 1 | 1/10 | 1 | 1 |
FR120 | thermostat | 191 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | 6 | 1 | 1 | 2 | 1 |
FR120 | thermostat | 191 | mode | operating mode | enum [nofrost|eco|heat|auto] | | True | select.thermostat_hc1_operating_mode | select.thermostat_hc1_mode | 6 | 1 | 1 | 3 | 1 |
FR120 | thermostat | 191 | modetype | mode type | enum [nofrost|eco|heat] | | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | 6 | 1 | 1 | 4 | 1 |
FR120 | thermostat | 191 | heattemp | heat temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_heat_temperature | number.thermostat_hc1_heattemp | 6 | 1 | 1/2 | 194 | 1 |
FR120 | thermostat | 191 | ecotemp | eco temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_eco_temperature | number.thermostat_hc1_ecotemp | 6 | 1 | 1/2 | 5 | 1 |
FR120 | thermostat | 191 | nofrosttemp | nofrost temperature | int8 (>=-63<=63) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp | 6 | 1 | 1/2 | 17 | 1 |
FR120 | thermostat | 191 | control | control device | enum [off|FB10|FB100] | | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | 6 | 1 | 1 | 40 | 1 |
FR120 | thermostat | 191 | program | program | enum [prog a|prog b|prog c|prog d|prog e|prog f] | | True | select.thermostat_hc1_program | select.thermostat_hc1_program | 6 | 1 | 1 | 25 | 1 |
FR120 | thermostat | 191 | remotetemp | room temperature from remote | cmd [] (>=-1<=101) | C | True | sensor.thermostat_hc1_room_temperature_from_remote | sensor.thermostat_hc1_remotetemp | 6 | 1 | 1/10 | 41 | 1 |
FR120 | thermostat | 191 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp | 6 | 1 | 1 | 18 | 1 |
FR120 | thermostat | 191 | summertemp | summer temperature | uint8 (>=9<=25) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp | 6 | 1 | 1/2 | 8 | 1 |
FR120 | thermostat | 191 | roomsensor | room sensor | enum [extern|intern|auto] | | True | select.thermostat_hc1_room_sensor | select.thermostat_hc1_roomsensor | 6 | 1 | 1 | 195 | 1 |
FR120 | thermostat | 191 | holidaymode | holiday mode | enum [nofrost|eco|heat|auto] | | True | select.thermostat_hc1_holiday_mode | select.thermostat_hc1_holidaymode | 6 | 1 | 1 | 55 | 1 |
FR120 | thermostat | 191 | switchonoptimization | switch-on optimization | boolean | | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | 6 | 1 | 1 | 29 | 1 |
FR120 | thermostat | 191 | heatup | heatup | enum [slow|medium|fast] | | True | select.thermostat_hc1_heatup | select.thermostat_hc1_heatup | 6 | 1 | 1 | 196 | 1 |
FR120 | thermostat | 191 | minflowtemp | min flow temperature | uint8 (>=5<=70) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp | 6 | 1 | 1 | 11 | 1 |
FR120 | thermostat | 191 | maxflowtemp | max flow temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp | 6 | 1 | 1 | 12 | 1 |
FR120 | thermostat | 191 | designtemp | design temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp | 6 | 1 | 1 | 9 | 1 |
FR120 | thermostat | 191 | roominfluence | room influence | enum [off|intern|extern|auto] | | True | select.thermostat_hc1_room_influence | select.thermostat_hc1_roominfluence | 6 | 1 | 1 | 13 | 1 |
FR120 | thermostat | 191 | roominflfactor | room influence factor | uint8 (>=0<=100) | % | True | number.thermostat_hc1_room_influence_factor | number.thermostat_hc1_roominflfactor | 6 | 1 | 10 | 14 | 1 |
FR120 | thermostat | 191 | heatingtype | heating type | enum [off|heatingcurve|radiator|convector|floor] | | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | 6 | 1 | 1 | 19 | 1 |
FR120 | thermostat | 191 | controlmode | control mode | enum [off|unmixed|unmixed IPM|mixed IPM] | | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | 6 | 1 | 1 | 24 | 1 |
FR120 | thermostat | 191 | charge | charge | boolean | | True | switch.thermostat_dhw_charge | switch.thermostat_dhw_charge | 6 | 9 | 1 | 5 | 1 |
FW120 | thermostat | 192 | errorcode | error code | string | | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | 6 | 0 | 1 | 0 | 8 |
FW120 | thermostat | 192 | lastcode | last error code | string | | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | 6 | 0 | 1 | 8 | 25 |
FW120 | thermostat | 192 | datetime | date/time | string | | True | sensor.thermostat_date/time | sensor.thermostat_datetime | 6 | 0 | 1 | 33 | 13 |
FW120 | thermostat | 192 | hybridstrategy | hybrid control strategy | enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] | | True | select.thermostat_hybrid_control_strategy | select.thermostat_hybridstrategy | 6 | 0 | 1 | 53 | 1 |
FW120 | thermostat | 192 | switchovertemp | outside switchover temperature | int8 (>=-20<=20) | C | True | number.thermostat_outside_switchover_temperature | number.thermostat_switchovertemp | 6 | 0 | 1 | 54 | 1 |
FW120 | thermostat | 192 | energycostratio | energy cost ratio | uint8 (>=0<=20) | | True | number.thermostat_energy_cost_ratio | number.thermostat_energycostratio | 6 | 0 | 1/10 | 55 | 1 |
FW120 | thermostat | 192 | fossilefactor | fossile energy factor | uint8 (>=0<=5) | | True | number.thermostat_fossile_energy_factor | number.thermostat_fossilefactor | 6 | 0 | 1/10 | 56 | 1 |
FW120 | thermostat | 192 | electricfactor | electric energy factor | uint8 (>=0<=5) | | True | number.thermostat_electric_energy_factor | number.thermostat_electricfactor | 6 | 0 | 1/10 | 57 | 1 |
FW120 | thermostat | 192 | delayboiler | delay boiler support | uint8 (>=5<=120) | minutes | True | number.thermostat_delay_boiler_support | number.thermostat_delayboiler | 6 | 0 | 1 | 58 | 1 |
FW120 | thermostat | 192 | tempdiffboiler | temp diff boiler support | uint8 (>=1<=99) | C | True | number.thermostat_temp_diff_boiler_support | number.thermostat_tempdiffboiler | 6 | 0 | 1 | 59 | 1 |
FW120 | thermostat | 192 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp | 6 | 1 | 1/10 | 0 | 1 |
FW120 | thermostat | 192 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp | 6 | 1 | 1/10 | 1 | 1 |
FW120 | thermostat | 192 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | 6 | 1 | 1 | 2 | 1 |
FW120 | thermostat | 192 | mode | operating mode | enum [nofrost|eco|heat|auto] | | True | select.thermostat_hc1_operating_mode | select.thermostat_hc1_mode | 6 | 1 | 1 | 3 | 1 |
FW120 | thermostat | 192 | modetype | mode type | enum [nofrost|eco|heat] | | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | 6 | 1 | 1 | 4 | 1 |
FW120 | thermostat | 192 | heattemp | heat temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_heat_temperature | number.thermostat_hc1_heattemp | 6 | 1 | 1/2 | 194 | 1 |
FW120 | thermostat | 192 | ecotemp | eco temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_eco_temperature | number.thermostat_hc1_ecotemp | 6 | 1 | 1/2 | 5 | 1 |
FW120 | thermostat | 192 | nofrosttemp | nofrost temperature | int8 (>=-63<=63) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp | 6 | 1 | 1/2 | 17 | 1 |
FW120 | thermostat | 192 | control | control device | enum [off|FB10|FB100] | | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | 6 | 1 | 1 | 40 | 1 |
FW120 | thermostat | 192 | program | program | enum [prog a|prog b|prog c|prog d|prog e|prog f] | | True | select.thermostat_hc1_program | select.thermostat_hc1_program | 6 | 1 | 1 | 25 | 1 |
FW120 | thermostat | 192 | remotetemp | room temperature from remote | cmd [] (>=-1<=101) | C | True | sensor.thermostat_hc1_room_temperature_from_remote | sensor.thermostat_hc1_remotetemp | 6 | 1 | 1/10 | 41 | 1 |
FW120 | thermostat | 192 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp | 6 | 1 | 1 | 18 | 1 |
FW120 | thermostat | 192 | summertemp | summer temperature | uint8 (>=9<=25) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp | 6 | 1 | 1/2 | 8 | 1 |
FW120 | thermostat | 192 | roomsensor | room sensor | enum [extern|intern|auto] | | True | select.thermostat_hc1_room_sensor | select.thermostat_hc1_roomsensor | 6 | 1 | 1 | 195 | 1 |
FW120 | thermostat | 192 | holidaymode | holiday mode | enum [nofrost|eco|heat|auto] | | True | select.thermostat_hc1_holiday_mode | select.thermostat_hc1_holidaymode | 6 | 1 | 1 | 55 | 1 |
FW120 | thermostat | 192 | switchonoptimization | switch-on optimization | boolean | | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | 6 | 1 | 1 | 29 | 1 |
FW120 | thermostat | 192 | heatup | heatup | enum [slow|medium|fast] | | True | select.thermostat_hc1_heatup | select.thermostat_hc1_heatup | 6 | 1 | 1 | 196 | 1 |
FW120 | thermostat | 192 | minflowtemp | min flow temperature | uint8 (>=5<=70) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp | 6 | 1 | 1 | 11 | 1 |
FW120 | thermostat | 192 | maxflowtemp | max flow temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp | 6 | 1 | 1 | 12 | 1 |
FW120 | thermostat | 192 | designtemp | design temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp | 6 | 1 | 1 | 9 | 1 |
FW120 | thermostat | 192 | roominfluence | room influence | enum [off|intern|extern|auto] | | True | select.thermostat_hc1_room_influence | select.thermostat_hc1_roominfluence | 6 | 1 | 1 | 13 | 1 |
FW120 | thermostat | 192 | roominflfactor | room influence factor | uint8 (>=0<=100) | % | True | number.thermostat_hc1_room_influence_factor | number.thermostat_hc1_roominflfactor | 6 | 1 | 10 | 14 | 1 |
FW120 | thermostat | 192 | heatingtype | heating type | enum [off|heatingcurve|radiator|convector|floor] | | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | 6 | 1 | 1 | 19 | 1 |
FW120 | thermostat | 192 | controlmode | control mode | enum [off|unmixed|unmixed IPM|mixed IPM] | | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | 6 | 1 | 1 | 24 | 1 |
FW120 | thermostat | 192 | charge | charge | boolean | | True | switch.thermostat_dhw_charge | switch.thermostat_dhw_charge | 6 | 9 | 1 | 5 | 1 |
RT800, RC220 | thermostat | 3 | errorcode | error code | string | | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | 6 | 0 | 1 | 0 | 8 |
RT800, RC220 | thermostat | 3 | lastcode | last error code | string | | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | 6 | 0 | 1 | 8 | 25 |
RT800, RC220 | thermostat | 3 | datetime | date/time | string | | False | sensor.thermostat_date/time | sensor.thermostat_datetime | 6 | 0 | 1 | 33 | 13 |
RT800, RC220 | thermostat | 3 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp | 6 | 1 | 1/2 | 0 | 1 |
RT800, RC220 | thermostat | 3 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp | 6 | 1 | 1/10 | 1 | 1 |
RT800, RC220 | thermostat | 3 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | 6 | 1 | 1 | 2 | 1 |
RC100H, CR10H | thermostat | 200 | errorcode | error code | string | | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | 6 | 0 | 1 | 0 | 8 |
RC100H, CR10H | thermostat | 200 | lastcode | last error code | string | | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | 6 | 0 | 1 | 8 | 25 |
RC100H, CR10H | thermostat | 200 | datetime | date/time | string | | False | sensor.thermostat_date/time | sensor.thermostat_datetime | 6 | 0 | 1 | 33 | 13 |
RC100H, CR10H | thermostat | 200 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp | 6 | 1 | 1/2 | 0 | 1 |
RC100H, CR10H | thermostat | 200 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp | 6 | 1 | 1/10 | 1 | 1 |
RC100H, CR10H | thermostat | 200 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | 6 | 1 | 1 | 2 | 1 |
TR120RF, CR20RF | thermostat | 249 | errorcode | error code | string | | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | 6 | 0 | 1 | 0 | 8 |
TR120RF, CR20RF | thermostat | 249 | lastcode | last error code | string | | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | 6 | 0 | 1 | 8 | 25 |
TR120RF, CR20RF | thermostat | 249 | datetime | date/time | string | | False | sensor.thermostat_date/time | sensor.thermostat_datetime | 6 | 0 | 1 | 33 | 13 |
TR120RF, CR20RF | thermostat | 249 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp | 6 | 1 | 1/2 | 0 | 1 |
TR120RF, CR20RF | thermostat | 249 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp | 6 | 1 | 1/10 | 1 | 1 |
TR120RF, CR20RF | thermostat | 249 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | 6 | 1 | 1 | 2 | 1 |
MM10 | mixer | 69 | flowtemphc | flow temperature (TC1) | uint16 (>=0<=3199) | C | False | sensor.mixer_hc1_flow_temperature_(TC1) | sensor.mixer_hc1_flowtemphc | 7 | 1 | 1/10 | 0 | 1 |
MM10 | mixer | 69 | valvestatus | mixing valve actuator (VC1) | int8 (>=-100<=100) | % | False | sensor.mixer_hc1_mixing_valve_actuator_(VC1) | sensor.mixer_hc1_valvestatus | 7 | 1 | 1 | 1 | 1 |
MM10 | mixer | 69 | flowsettemp | setpoint flow temperature | uint8 (>=0<=254) | C | True | number.mixer_hc1_setpoint_flow_temperature | number.mixer_hc1_flowsettemp | 7 | 1 | 1 | 2 | 1 |
MM10 | mixer | 69 | pumpstatus | pump status (PC1) | boolean | | True | switch.mixer_hc1_pump_status_(PC1) | switch.mixer_hc1_pumpstatus | 7 | 1 | 1 | 3 | 1 |
MM10 | mixer | 69 | activated | activated | boolean | | True | switch.mixer_hc1_activated | switch.mixer_hc1_activated | 7 | 1 | 1 | 4 | 1 |
MM10 | mixer | 69 | valvesettime | time to set valve | uint8 (>=10<=600) | seconds | True | number.mixer_hc1_time_to_set_valve | number.mixer_hc1_valvesettime | 7 | 1 | 10 | 5 | 1 |
IPM | mixer | 100 | flowtemphc | flow temperature (TC1) | uint16 (>=0<=3199) | C | False | sensor.mixer_hc1_flow_temperature_(TC1) | sensor.mixer_hc1_flowtemphc | 7 | 1 | 1/10 | 0 | 1 |
IPM | mixer | 100 | valvestatus | mixing valve actuator (VC1) | uint8 (>=0<=100) | % | False | sensor.mixer_hc1_mixing_valve_actuator_(VC1) | sensor.mixer_hc1_valvestatus | 7 | 1 | 1 | 1 | 1 |
IPM | mixer | 100 | flowsettemp | setpoint flow temperature | uint8 (>=0<=254) | C | True | number.mixer_hc1_setpoint_flow_temperature | number.mixer_hc1_flowsettemp | 7 | 1 | 1 | 2 | 1 |
IPM | mixer | 100 | pumpstatus | pump status (PC1) | boolean | | True | switch.mixer_hc1_pump_status_(PC1) | switch.mixer_hc1_pumpstatus | 7 | 1 | 1 | 3 | 1 |
IPM | mixer | 100 | flowtempvf | flow temperature in header (T0/Vf) | uint16 (>=0<=3199) | C | False | sensor.mixer_hc1_flow_temperature_in_header_(T0/Vf) | sensor.mixer_hc1_flowtempvf | 7 | 1 | 1/10 | 6 | 1 |
IPM | mixer | 102 | flowtemphc | flow temperature (TC1) | uint16 (>=0<=3199) | C | False | sensor.mixer_hc1_flow_temperature_(TC1) | sensor.mixer_hc1_flowtemphc | 7 | 1 | 1/10 | 0 | 1 |
IPM | mixer | 102 | valvestatus | mixing valve actuator (VC1) | uint8 (>=0<=100) | % | False | sensor.mixer_hc1_mixing_valve_actuator_(VC1) | sensor.mixer_hc1_valvestatus | 7 | 1 | 1 | 1 | 1 |
IPM | mixer | 102 | flowsettemp | setpoint flow temperature | uint8 (>=0<=254) | C | True | number.mixer_hc1_setpoint_flow_temperature | number.mixer_hc1_flowsettemp | 7 | 1 | 1 | 2 | 1 |
IPM | mixer | 102 | pumpstatus | pump status (PC1) | boolean | | True | switch.mixer_hc1_pump_status_(PC1) | switch.mixer_hc1_pumpstatus | 7 | 1 | 1 | 3 | 1 |
IPM | mixer | 102 | flowtempvf | flow temperature in header (T0/Vf) | uint16 (>=0<=3199) | C | False | sensor.mixer_hc1_flow_temperature_in_header_(T0/Vf) | sensor.mixer_hc1_flowtempvf | 7 | 1 | 1/10 | 6 | 1 |
MM50 | mixer | 159 | flowtemphc | flow temperature (TC1) | uint16 (>=0<=3199) | C | False | sensor.mixer_hc1_flow_temperature_(TC1) | sensor.mixer_hc1_flowtemphc | 7 | 1 | 1/10 | 0 | 1 |
MM50 | mixer | 159 | valvestatus | mixing valve actuator (VC1) | uint8 (>=0<=100) | % | False | sensor.mixer_hc1_mixing_valve_actuator_(VC1) | sensor.mixer_hc1_valvestatus | 7 | 1 | 1 | 1 | 1 |
MM50 | mixer | 159 | flowsettemp | setpoint flow temperature | uint8 (>=0<=254) | C | True | number.mixer_hc1_setpoint_flow_temperature | number.mixer_hc1_flowsettemp | 7 | 1 | 1 | 2 | 1 |
MM50 | mixer | 159 | pumpstatus | pump status (PC1) | boolean | | True | switch.mixer_hc1_pump_status_(PC1) | switch.mixer_hc1_pumpstatus | 7 | 1 | 1 | 3 | 1 |
MM50 | mixer | 159 | activated | activated | boolean | | True | switch.mixer_hc1_activated | switch.mixer_hc1_activated | 7 | 1 | 1 | 4 | 1 |
MM50 | mixer | 159 | valvesettime | time to set valve | uint8 (>=10<=600) | seconds | True | number.mixer_hc1_time_to_set_valve | number.mixer_hc1_valvesettime | 7 | 1 | 10 | 5 | 1 |
MM50 | mixer | 159 | flowtempoffset | flow temperature offset for mixer | uint8 (>=0<=20) | K | True | number.mixer_hc1_flow_temperature_offset_for_mixer | number.mixer_hc1_flowtempoffset | 7 | 1 | 1 | 7 | 1 |
MM100 | mixer | 160 | flowtemphc | flow temperature (TC1) | uint16 (>=0<=3199) | C | False | sensor.mixer_dhw_flow_temperature_(TC1) | sensor.mixer_dhw_flowtemphc | 7 | 9 | 1/10 | 0 | 1 |
MM100 | mixer | 160 | valvestatus | mixing valve actuator (VC1) | uint8 (>=0<=100) | % | False | sensor.mixer_dhw_mixing_valve_actuator_(VC1) | sensor.mixer_dhw_valvestatus | 7 | 9 | 1 | 1 | 1 |
MM100 | mixer | 160 | flowsettemp | setpoint flow temperature | uint8 (>=0<=254) | C | True | number.mixer_dhw_setpoint_flow_temperature | number.mixer_dhw_flowsettemp | 7 | 9 | 1 | 2 | 1 |
MM100 | mixer | 160 | pumpstatus | pump status (PC1) | boolean | | True | switch.mixer_dhw_pump_status_(PC1) | switch.mixer_dhw_pumpstatus | 7 | 9 | 1 | 3 | 1 |
MM100 | mixer | 160 | activated | activated | boolean | | True | switch.mixer_dhw_activated | switch.mixer_dhw_activated | 7 | 9 | 1 | 4 | 1 |
MM100 | mixer | 160 | valvesettime | time to set valve | uint8 (>=10<=600) | seconds | True | number.mixer_dhw_time_to_set_valve | number.mixer_dhw_valvesettime | 7 | 9 | 10 | 5 | 1 |
MM100 | mixer | 160 | flowtempoffset | flow temperature offset for mixer | uint8 (>=0<=20) | K | True | number.mixer_dhw_flow_temperature_offset_for_mixer | number.mixer_dhw_flowtempoffset | 7 | 9 | 1 | 6 | 1 |
MM200 | mixer | 161 | flowtemphc | flow temperature (TC1) | uint16 (>=0<=3199) | C | False | sensor.mixer_hc1_flow_temperature_(TC1) | sensor.mixer_hc1_flowtemphc | 7 | 1 | 1/10 | 0 | 1 |
MM200 | mixer | 161 | valvestatus | mixing valve actuator (VC1) | uint8 (>=0<=100) | % | False | sensor.mixer_hc1_mixing_valve_actuator_(VC1) | sensor.mixer_hc1_valvestatus | 7 | 1 | 1 | 1 | 1 |
MM200 | mixer | 161 | flowsettemp | setpoint flow temperature | uint8 (>=0<=254) | C | True | number.mixer_hc1_setpoint_flow_temperature | number.mixer_hc1_flowsettemp | 7 | 1 | 1 | 2 | 1 |
MM200 | mixer | 161 | pumpstatus | pump status (PC1) | boolean | | True | switch.mixer_hc1_pump_status_(PC1) | switch.mixer_hc1_pumpstatus | 7 | 1 | 1 | 3 | 1 |
MM200 | mixer | 161 | activated | activated | boolean | | True | switch.mixer_hc1_activated | switch.mixer_hc1_activated | 7 | 1 | 1 | 4 | 1 |
MM200 | mixer | 161 | valvesettime | time to set valve | uint8 (>=10<=600) | seconds | True | number.mixer_hc1_time_to_set_valve | number.mixer_hc1_valvesettime | 7 | 1 | 10 | 5 | 1 |
MM200 | mixer | 161 | flowtempoffset | flow temperature offset for mixer | uint8 (>=0<=20) | K | True | number.mixer_hc1_flow_temperature_offset_for_mixer | number.mixer_hc1_flowtempoffset | 7 | 1 | 1 | 7 | 1 |
MZ100 | mixer | 193 | flowtemphc | flow temperature (TC1) | uint16 (>=0<=3199) | C | False | sensor.mixer_hc1_flow_temperature_(TC1) | sensor.mixer_hc1_flowtemphc | 7 | 1 | 1/10 | 0 | 1 |
MZ100 | mixer | 193 | valvestatus | mixing valve actuator (VC1) | uint8 (>=0<=100) | % | False | sensor.mixer_hc1_mixing_valve_actuator_(VC1) | sensor.mixer_hc1_valvestatus | 7 | 1 | 1 | 1 | 1 |
MZ100 | mixer | 193 | flowsettemp | setpoint flow temperature | uint8 (>=0<=254) | C | True | number.mixer_hc1_setpoint_flow_temperature | number.mixer_hc1_flowsettemp | 7 | 1 | 1 | 2 | 1 |
MZ100 | mixer | 193 | pumpstatus | pump status (PC1) | boolean | | True | switch.mixer_hc1_pump_status_(PC1) | switch.mixer_hc1_pumpstatus | 7 | 1 | 1 | 3 | 1 |
MZ100 | mixer | 193 | activated | activated | boolean | | True | switch.mixer_hc1_activated | switch.mixer_hc1_activated | 7 | 1 | 1 | 4 | 1 |
MZ100 | mixer | 193 | valvesettime | time to set valve | uint8 (>=10<=600) | seconds | True | number.mixer_hc1_time_to_set_valve | number.mixer_hc1_valvesettime | 7 | 1 | 10 | 5 | 1 |
MZ100 | mixer | 193 | flowtempoffset | flow temperature offset for mixer | uint8 (>=0<=20) | K | True | number.mixer_hc1_flow_temperature_offset_for_mixer | number.mixer_hc1_flowtempoffset | 7 | 1 | 1 | 7 | 1 |
SM10 | solar | 73 | collectortemp | collector temperature (TS1) | int16 (>=-3199<=3199) | C | False | sensor.solar_collector_temperature_(TS1) | sensor.solar_collectortemp | 8 | 0 | 1/10 | 0 | 1 |
SM10 | solar | 73 | cylbottomtemp | cylinder bottom temperature (TS2) | int16 (>=-3199<=3199) | C | False | sensor.solar_cylinder_bottom_temperature_(TS2) | sensor.solar_cylbottomtemp | 8 | 0 | 1/10 | 1 | 1 |
SM10 | solar | 73 | solarpump | pump (PS1) | boolean | | False | binary_sensor.solar_pump_(PS1) | binary_sensor.solar_solarpump | 8 | 0 | 1 | 2 | 1 |
SM10 | solar | 73 | pumpworktime | pump working time | time (>=0<=16777213) | minutes | False | sensor.solar_pump_working_time | sensor.solar_pumpworktime | 8 | 0 | 1 | 3 | 2 |
SM10 | solar | 73 | cylmaxtemp | maximum cylinder temperature | uint8 (>=0<=254) | C | True | number.solar_maximum_cylinder_temperature | number.solar_cylmaxtemp | 8 | 0 | 1 | 5 | 1 |
SM10 | solar | 73 | collectorshutdown | collector shutdown | boolean | | False | binary_sensor.solar_collector_shutdown | binary_sensor.solar_collectorshutdown | 8 | 0 | 1 | 6 | 1 |
SM10 | solar | 73 | cylheated | cyl heated | boolean | | False | binary_sensor.solar_cyl_heated | binary_sensor.solar_cylheated | 8 | 0 | 1 | 7 | 1 |
SM10 | solar | 73 | solarpumpmod | pump modulation (PS1) | uint8 (>=0<=100) | % | False | sensor.solar_pump_modulation_(PS1) | sensor.solar_solarpumpmod | 8 | 0 | 1 | 8 | 1 |
SM10 | solar | 73 | pumpminmod | minimum pump modulation | uint8 (>=0<=100) | % | True | number.solar_minimum_pump_modulation | number.solar_pumpminmod | 8 | 0 | 1 | 9 | 1 |
SM10 | solar | 73 | turnondiff | pump turn on difference | uint8 (>=0<=254) | C | True | number.solar_pump_turn_on_difference | number.solar_turnondiff | 8 | 0 | 1 | 10 | 1 |
SM10 | solar | 73 | turnoffdiff | pump turn off difference | uint8 (>=0<=254) | C | True | number.solar_pump_turn_off_difference | number.solar_turnoffdiff | 8 | 0 | 1 | 11 | 1 |
SM10 | solar | 73 | solarpower | actual solar power | int16 (>=-31999<=31999) | W | False | sensor.solar_actual_solar_power | sensor.solar_solarpower | 8 | 0 | 1 | 12 | 1 |
SM10 | solar | 73 | energylasthour | energy last hour | uint24 (>=0<=1677721) | Wh | False | sensor.solar_energy_last_hour | sensor.solar_energylasthour | 8 | 0 | 1/10 | 13 | 2 |
SM10 | solar | 73 | maxflow | maximum solar flow | uint8 (>=0<=25) | l/min | True | number.solar_maximum_solar_flow | number.solar_maxflow | 8 | 0 | 1/10 | 15 | 1 |
SM10 | solar | 73 | mintemp | minimum temperature | uint8 (>=0<=254) | C | True | number.solar_dhw_minimum_temperature | number.solar_dhw_mintemp | 8 | 9 | 1 | 0 | 1 |
SM10 | solar | 73 | solarenabled | solarmodule enabled | boolean | | True | switch.solar_solarmodule_enabled | switch.solar_solarenabled | 8 | 0 | 1 | 16 | 1 |
ISM1 | solar | 101 | collectortemp | collector temperature (TS1) | int16 (>=-3199<=3199) | C | False | sensor.solar_collector_temperature_(TS1) | sensor.solar_collectortemp | 8 | 0 | 1/10 | 0 | 1 |
ISM1 | solar | 101 | cylbottomtemp | cylinder bottom temperature (TS2) | int16 (>=-3199<=3199) | C | False | sensor.solar_cylinder_bottom_temperature_(TS2) | sensor.solar_cylbottomtemp | 8 | 0 | 1/10 | 1 | 1 |
ISM1 | solar | 101 | solarpump | pump (PS1) | boolean | | False | binary_sensor.solar_pump_(PS1) | binary_sensor.solar_solarpump | 8 | 0 | 1 | 2 | 1 |
ISM1 | solar | 101 | pumpworktime | pump working time | time (>=0<=16777213) | minutes | False | sensor.solar_pump_working_time | sensor.solar_pumpworktime | 8 | 0 | 1 | 3 | 2 |
ISM1 | solar | 101 | cylmaxtemp | maximum cylinder temperature | uint8 (>=0<=254) | C | True | number.solar_maximum_cylinder_temperature | number.solar_cylmaxtemp | 8 | 0 | 1 | 5 | 1 |
ISM1 | solar | 101 | collectorshutdown | collector shutdown | boolean | | False | binary_sensor.solar_collector_shutdown | binary_sensor.solar_collectorshutdown | 8 | 0 | 1 | 6 | 1 |
ISM1 | solar | 101 | cylheated | cyl heated | boolean | | False | binary_sensor.solar_cyl_heated | binary_sensor.solar_cylheated | 8 | 0 | 1 | 7 | 1 |
ISM1 | solar | 101 | cylmiddletemp | cylinder middle temperature (TS3) | int16 (>=-3199<=3199) | C | False | sensor.solar_cylinder_middle_temperature_(TS3) | sensor.solar_cylmiddletemp | 8 | 0 | 1/10 | 17 | 1 |
ISM1 | solar | 101 | retheatassist | return temperature heat assistance (TS4) | int16 (>=-3199<=3199) | C | False | sensor.solar_return_temperature_heat_assistance_(TS4) | sensor.solar_retheatassist | 8 | 0 | 1/10 | 18 | 1 |
ISM1 | solar | 101 | heatassistvalve | heat assistance valve (M1) | boolean | | False | binary_sensor.solar_heat_assistance_valve_(M1) | binary_sensor.solar_heatassistvalve | 8 | 0 | 1 | 19 | 1 |
ISM1 | solar | 101 | energylasthour | energy last hour | uint24 (>=0<=1677721) | Wh | False | sensor.solar_energy_last_hour | sensor.solar_energylasthour | 8 | 0 | 1/10 | 13 | 2 |
ISM2 | solar | 103 | collectortemp | collector temperature (TS1) | int16 (>=-3199<=3199) | C | False | sensor.solar_collector_temperature_(TS1) | sensor.solar_collectortemp | 8 | 0 | 1/10 | 0 | 1 |
ISM2 | solar | 103 | cylbottomtemp | cylinder bottom temperature (TS2) | int16 (>=-3199<=3199) | C | False | sensor.solar_cylinder_bottom_temperature_(TS2) | sensor.solar_cylbottomtemp | 8 | 0 | 1/10 | 1 | 1 |
ISM2 | solar | 103 | solarpump | pump (PS1) | boolean | | False | binary_sensor.solar_pump_(PS1) | binary_sensor.solar_solarpump | 8 | 0 | 1 | 2 | 1 |
ISM2 | solar | 103 | pumpworktime | pump working time | time (>=0<=16777213) | minutes | False | sensor.solar_pump_working_time | sensor.solar_pumpworktime | 8 | 0 | 1 | 3 | 2 |
ISM2 | solar | 103 | cylmaxtemp | maximum cylinder temperature | uint8 (>=0<=254) | C | True | number.solar_maximum_cylinder_temperature | number.solar_cylmaxtemp | 8 | 0 | 1 | 5 | 1 |
ISM2 | solar | 103 | collectorshutdown | collector shutdown | boolean | | False | binary_sensor.solar_collector_shutdown | binary_sensor.solar_collectorshutdown | 8 | 0 | 1 | 6 | 1 |
ISM2 | solar | 103 | cylheated | cyl heated | boolean | | False | binary_sensor.solar_cyl_heated | binary_sensor.solar_cylheated | 8 | 0 | 1 | 7 | 1 |
ISM2 | solar | 103 | cylmiddletemp | cylinder middle temperature (TS3) | int16 (>=-3199<=3199) | C | False | sensor.solar_cylinder_middle_temperature_(TS3) | sensor.solar_cylmiddletemp | 8 | 0 | 1/10 | 17 | 1 |
ISM2 | solar | 103 | retheatassist | return temperature heat assistance (TS4) | int16 (>=-3199<=3199) | C | False | sensor.solar_return_temperature_heat_assistance_(TS4) | sensor.solar_retheatassist | 8 | 0 | 1/10 | 18 | 1 |
ISM2 | solar | 103 | heatassistvalve | heat assistance valve (M1) | boolean | | False | binary_sensor.solar_heat_assistance_valve_(M1) | binary_sensor.solar_heatassistvalve | 8 | 0 | 1 | 19 | 1 |
ISM2 | solar | 103 | energylasthour | energy last hour | uint24 (>=0<=1677721) | Wh | False | sensor.solar_energy_last_hour | sensor.solar_energylasthour | 8 | 0 | 1/10 | 13 | 2 |
SM50 | solar | 162 | collectortemp | collector temperature (TS1) | int16 (>=-3199<=3199) | C | False | sensor.solar_collector_temperature_(TS1) | sensor.solar_collectortemp | 8 | 0 | 1/10 | 0 | 1 |
SM50 | solar | 162 | cylbottomtemp | cylinder bottom temperature (TS2) | int16 (>=-3199<=3199) | C | False | sensor.solar_cylinder_bottom_temperature_(TS2) | sensor.solar_cylbottomtemp | 8 | 0 | 1/10 | 1 | 1 |
SM50 | solar | 162 | solarpump | pump (PS1) | boolean | | False | binary_sensor.solar_pump_(PS1) | binary_sensor.solar_solarpump | 8 | 0 | 1 | 2 | 1 |
SM50 | solar | 162 | pumpworktime | pump working time | time (>=0<=16777213) | minutes | False | sensor.solar_pump_working_time | sensor.solar_pumpworktime | 8 | 0 | 1 | 3 | 2 |
SM50 | solar | 162 | cylmaxtemp | maximum cylinder temperature | uint8 (>=0<=254) | C | True | number.solar_maximum_cylinder_temperature | number.solar_cylmaxtemp | 8 | 0 | 1 | 5 | 1 |
SM50 | solar | 162 | collectorshutdown | collector shutdown | boolean | | False | binary_sensor.solar_collector_shutdown | binary_sensor.solar_collectorshutdown | 8 | 0 | 1 | 6 | 1 |
SM50 | solar | 162 | cylheated | cyl heated | boolean | | False | binary_sensor.solar_cyl_heated | binary_sensor.solar_cylheated | 8 | 0 | 1 | 7 | 1 |
SM50 | solar | 162 | solarpumpmod | pump modulation (PS1) | uint8 (>=0<=100) | % | False | sensor.solar_pump_modulation_(PS1) | sensor.solar_solarpumpmod | 8 | 0 | 1 | 8 | 1 |
SM50 | solar | 162 | pumpminmod | minimum pump modulation | uint8 (>=0<=100) | % | True | number.solar_minimum_pump_modulation | number.solar_pumpminmod | 8 | 0 | 5 | 9 | 1 |
SM50 | solar | 162 | turnondiff | pump turn on difference | uint8 (>=0<=25) | C | True | number.solar_pump_turn_on_difference | number.solar_turnondiff | 8 | 0 | 1/10 | 10 | 1 |
SM50 | solar | 162 | turnoffdiff | pump turn off difference | uint8 (>=0<=25) | C | True | number.solar_pump_turn_off_difference | number.solar_turnoffdiff | 8 | 0 | 1/10 | 11 | 1 |
SM50 | solar | 162 | collector2temp | collector 2 temperature (TS7) | int16 (>=-3199<=3199) | C | False | sensor.solar_collector_2_temperature_(TS7) | sensor.solar_collector2temp | 8 | 0 | 1/10 | 20 | 1 |
SM50 | solar | 162 | cylmiddletemp | cylinder middle temperature (TS3) | int16 (>=-3199<=3199) | C | False | sensor.solar_cylinder_middle_temperature_(TS3) | sensor.solar_cylmiddletemp | 8 | 0 | 1/10 | 17 | 1 |
SM50 | solar | 162 | retheatassist | return temperature heat assistance (TS4) | int16 (>=-3199<=3199) | C | False | sensor.solar_return_temperature_heat_assistance_(TS4) | sensor.solar_retheatassist | 8 | 0 | 1/10 | 18 | 1 |
SM50 | solar | 162 | heatassistvalve | heat assistance valve (M1) | boolean | | False | binary_sensor.solar_heat_assistance_valve_(M1) | binary_sensor.solar_heatassistvalve | 8 | 0 | 1 | 19 | 1 |
SM50 | solar | 162 | heatassistpower | heat assistance valve power (M1) | uint8 (>=0<=100) | % | False | sensor.solar_heat_assistance_valve_power_(M1) | sensor.solar_heatassistpower | 8 | 0 | 1 | 21 | 1 |
SM50 | solar | 162 | solarpump2 | pump 2 (PS4) | boolean | | False | binary_sensor.solar_pump_2_(PS4) | binary_sensor.solar_solarpump2 | 8 | 0 | 1 | 22 | 1 |
SM50 | solar | 162 | solarpump2mod | pump 2 modulation (PS4) | uint8 (>=0<=100) | % | False | sensor.solar_pump_2_modulation_(PS4) | sensor.solar_solarpump2mod | 8 | 0 | 1 | 23 | 1 |
SM50 | solar | 162 | cyl2bottomtemp | second cylinder bottom temperature (TS5) | int16 (>=-3199<=3199) | C | False | sensor.solar_second_cylinder_bottom_temperature_(TS5) | sensor.solar_cyl2bottomtemp | 8 | 0 | 1/10 | 24 | 1 |
SM50 | solar | 162 | heatexchangertemp | heat exchanger temperature (TS6) | int16 (>=-3199<=3199) | C | False | sensor.solar_heat_exchanger_temperature_(TS6) | sensor.solar_heatexchangertemp | 8 | 0 | 1/10 | 25 | 1 |
SM50 | solar | 162 | cylpumpmod | cylinder pump modulation (PS5) | uint8 (>=0<=100) | % | False | sensor.solar_cylinder_pump_modulation_(PS5) | sensor.solar_cylpumpmod | 8 | 0 | 1 | 26 | 1 |
SM50 | solar | 162 | valvestatus | valve status | boolean | | False | binary_sensor.solar_valve_status | binary_sensor.solar_valvestatus | 8 | 0 | 1 | 27 | 1 |
SM50 | solar | 162 | vs1status | valve status VS1 | boolean | | False | binary_sensor.solar_valve_status_VS1 | binary_sensor.solar_vs1status | 8 | 0 | 1 | 28 | 1 |
SM50 | solar | 162 | collectormaxtemp | maximum collector temperature | uint8 (>=0<=254) | C | True | number.solar_maximum_collector_temperature | number.solar_collectormaxtemp | 8 | 0 | 1 | 29 | 1 |
SM50 | solar | 162 | collectormintemp | minimum collector temperature | uint8 (>=0<=254) | C | True | number.solar_minimum_collector_temperature | number.solar_collectormintemp | 8 | 0 | 1 | 30 | 1 |
SM50 | solar | 162 | energylasthour | energy last hour | uint24 (>=0<=1677721) | Wh | False | sensor.solar_energy_last_hour | sensor.solar_energylasthour | 8 | 0 | 1/10 | 13 | 2 |
SM50 | solar | 162 | energytoday | total energy today | uint24 (>=0<=16777213) | Wh | False | sensor.solar_total_energy_today | sensor.solar_energytoday | 8 | 0 | 1 | 31 | 2 |
SM50 | solar | 162 | energytotal | total energy | uint24 (>=0<=1677721) | kWh | False | sensor.solar_total_energy | sensor.solar_energytotal | 8 | 0 | 1/10 | 33 | 2 |
SM50 | solar | 162 | pump2worktime | pump 2 working time | time (>=0<=16777213) | minutes | False | sensor.solar_pump_2_working_time | sensor.solar_pump2worktime | 8 | 0 | 1 | 35 | 2 |
SM50 | solar | 162 | m1worktime | differential control working time | time (>=0<=16777213) | minutes | False | sensor.solar_differential_control_working_time | sensor.solar_m1worktime | 8 | 0 | 1 | 37 | 2 |
SM50 | solar | 162 | heattransfersystem | heattransfer system | boolean | | True | switch.solar_heattransfer_system | switch.solar_heattransfersystem | 8 | 0 | 1 | 39 | 1 |
SM50 | solar | 162 | externalcyl | external cylinder | boolean | | True | switch.solar_external_cylinder | switch.solar_externalcyl | 8 | 0 | 1 | 40 | 1 |
SM50 | solar | 162 | thermaldisinfect | thermal disinfection | boolean | | True | switch.solar_thermal_disinfection | switch.solar_thermaldisinfect | 8 | 0 | 1 | 41 | 1 |
SM50 | solar | 162 | heatmetering | heatmetering | boolean | | True | switch.solar_heatmetering | switch.solar_heatmetering | 8 | 0 | 1 | 42 | 1 |
SM50 | solar | 162 | activated | activated | boolean | | True | switch.solar_activated | switch.solar_activated | 8 | 0 | 1 | 43 | 1 |
SM50 | solar | 162 | solarpumpmode | solar pump mode | enum [constant|pwm|analog] | | True | select.solar_solar_pump_mode | select.solar_solarpumpmode | 8 | 0 | 1 | 44 | 1 |
SM50 | solar | 162 | solarpumpkick | solar pump kick | boolean | | True | switch.solar_solar_pump_kick | switch.solar_solarpumpkick | 8 | 0 | 1 | 45 | 1 |
SM50 | solar | 162 | plainwatermode | plain water mode | boolean | | True | switch.solar_plain_water_mode | switch.solar_plainwatermode | 8 | 0 | 1 | 46 | 1 |
SM50 | solar | 162 | doublematchflow | doublematchflow | boolean | | True | switch.solar_doublematchflow | switch.solar_doublematchflow | 8 | 0 | 1 | 47 | 1 |
SM50 | solar | 162 | pump2minmod | minimum pump 2 modulation | uint8 (>=0<=100) | % | True | number.solar_minimum_pump_2_modulation | number.solar_pump2minmod | 8 | 0 | 1 | 48 | 1 |
SM50 | solar | 162 | turnondiff2 | pump 2 turn on difference | uint8 (>=0<=25) | C | True | number.solar_pump_2_turn_on_difference | number.solar_turnondiff2 | 8 | 0 | 1/10 | 49 | 1 |
SM50 | solar | 162 | turnoffdiff2 | pump 2 turn off difference | uint8 (>=0<=25) | C | True | number.solar_pump_2_turn_off_difference | number.solar_turnoffdiff2 | 8 | 0 | 1/10 | 50 | 1 |
SM50 | solar | 162 | pump2kick | pump kick 2 | boolean | | True | switch.solar_pump_kick_2 | switch.solar_pump2kick | 8 | 0 | 1 | 51 | 1 |
SM50 | solar | 162 | climatezone | climate zone | uint8 (>=0<=254) | | True | number.solar_climate_zone | number.solar_climatezone | 8 | 0 | 1 | 52 | 1 |
SM50 | solar | 162 | collector1area | collector 1 area | uint16 (>=0<=3199) | m² | True | number.solar_collector_1_area | number.solar_collector1area | 8 | 0 | 1/10 | 53 | 1 |
SM50 | solar | 162 | collector1type | collector 1 type | enum [flat|vacuum] | | True | select.solar_collector_1_type | select.solar_collector1type | 8 | 0 | 1 | 54 | 1 |
SM50 | solar | 162 | collector2area | collector 2 area | uint16 (>=0<=3199) | m² | True | number.solar_collector_2_area | number.solar_collector2area | 8 | 0 | 1/10 | 55 | 1 |
SM50 | solar | 162 | collector2type | collector 2 type | enum [flat|vacuum] | | True | select.solar_collector_2_type | select.solar_collector2type | 8 | 0 | 1 | 56 | 1 |
SM50 | solar | 162 | cylpriority | cylinder priority | enum [cyl 1|cyl 2] | | True | select.solar_cylinder_priority | select.solar_cylpriority | 8 | 0 | 1 | 57 | 1 |
SM50 | solar | 162 | heatcntflowtemp | heat counter flow temperature | uint16 (>=0<=3199) | C | False | sensor.solar_heat_counter_flow_temperature | sensor.solar_heatcntflowtemp | 8 | 0 | 1/10 | 58 | 1 |
SM50 | solar | 162 | heatcntrettemp | heat counter return temperature | uint16 (>=0<=3199) | C | False | sensor.solar_heat_counter_return_temperature | sensor.solar_heatcntrettemp | 8 | 0 | 1/10 | 59 | 1 |
SM50 | solar | 162 | heatcnt | heat counter impulses | uint8 (>=0<=254) | | False | sensor.solar_heat_counter_impulses | sensor.solar_heatcnt | 8 | 0 | 1 | 60 | 1 |
SM50 | solar | 162 | swapflowtemp | swap flow temperature (TS14) | uint16 (>=0<=3199) | C | False | sensor.solar_swap_flow_temperature_(TS14) | sensor.solar_swapflowtemp | 8 | 0 | 1/10 | 61 | 1 |
SM50 | solar | 162 | swaprettemp | swap return temperature (TS15) | uint16 (>=0<=3199) | C | False | sensor.solar_swap_return_temperature_(TS15) | sensor.solar_swaprettemp | 8 | 0 | 1/10 | 62 | 1 |
SM100, MS100 | solar | 163 | collectortemp | collector temperature (TS1) | int16 (>=-3199<=3199) | C | False | sensor.solar_collector_temperature_(TS1) | sensor.solar_collectortemp | 8 | 0 | 1/10 | 0 | 1 |
SM100, MS100 | solar | 163 | cylbottomtemp | cylinder bottom temperature (TS2) | int16 (>=-3199<=3199) | C | False | sensor.solar_cylinder_bottom_temperature_(TS2) | sensor.solar_cylbottomtemp | 8 | 0 | 1/10 | 1 | 1 |
SM100, MS100 | solar | 163 | solarpump | pump (PS1) | boolean | | False | binary_sensor.solar_pump_(PS1) | binary_sensor.solar_solarpump | 8 | 0 | 1 | 2 | 1 |
SM100, MS100 | solar | 163 | pumpworktime | pump working time | time (>=0<=16777213) | minutes | False | sensor.solar_pump_working_time | sensor.solar_pumpworktime | 8 | 0 | 1 | 3 | 2 |
SM100, MS100 | solar | 163 | cylmaxtemp | maximum cylinder temperature | uint8 (>=0<=254) | C | True | number.solar_maximum_cylinder_temperature | number.solar_cylmaxtemp | 8 | 0 | 1 | 5 | 1 |
SM100, MS100 | solar | 163 | collectorshutdown | collector shutdown | boolean | | False | binary_sensor.solar_collector_shutdown | binary_sensor.solar_collectorshutdown | 8 | 0 | 1 | 6 | 1 |
SM100, MS100 | solar | 163 | cylheated | cyl heated | boolean | | False | binary_sensor.solar_cyl_heated | binary_sensor.solar_cylheated | 8 | 0 | 1 | 7 | 1 |
SM100, MS100 | solar | 163 | solarpumpmod | pump modulation (PS1) | uint8 (>=0<=100) | % | False | sensor.solar_pump_modulation_(PS1) | sensor.solar_solarpumpmod | 8 | 0 | 1 | 8 | 1 |
SM100, MS100 | solar | 163 | pumpminmod | minimum pump modulation | uint8 (>=0<=100) | % | True | number.solar_minimum_pump_modulation | number.solar_pumpminmod | 8 | 0 | 5 | 9 | 1 |
SM100, MS100 | solar | 163 | turnondiff | pump turn on difference | uint8 (>=0<=25) | C | True | number.solar_pump_turn_on_difference | number.solar_turnondiff | 8 | 0 | 1/10 | 10 | 1 |
SM100, MS100 | solar | 163 | turnoffdiff | pump turn off difference | uint8 (>=0<=25) | C | True | number.solar_pump_turn_off_difference | number.solar_turnoffdiff | 8 | 0 | 1/10 | 11 | 1 |
SM100, MS100 | solar | 163 | collector2temp | collector 2 temperature (TS7) | int16 (>=-3199<=3199) | C | False | sensor.solar_collector_2_temperature_(TS7) | sensor.solar_collector2temp | 8 | 0 | 1/10 | 20 | 1 |
SM100, MS100 | solar | 163 | cylmiddletemp | cylinder middle temperature (TS3) | int16 (>=-3199<=3199) | C | False | sensor.solar_cylinder_middle_temperature_(TS3) | sensor.solar_cylmiddletemp | 8 | 0 | 1/10 | 17 | 1 |
SM100, MS100 | solar | 163 | retheatassist | return temperature heat assistance (TS4) | int16 (>=-3199<=3199) | C | False | sensor.solar_return_temperature_heat_assistance_(TS4) | sensor.solar_retheatassist | 8 | 0 | 1/10 | 18 | 1 |
SM100, MS100 | solar | 163 | heatassistvalve | heat assistance valve (M1) | boolean | | False | binary_sensor.solar_heat_assistance_valve_(M1) | binary_sensor.solar_heatassistvalve | 8 | 0 | 1 | 19 | 1 |
SM100, MS100 | solar | 163 | heatassistpower | heat assistance valve power (M1) | uint8 (>=0<=100) | % | False | sensor.solar_heat_assistance_valve_power_(M1) | sensor.solar_heatassistpower | 8 | 0 | 1 | 21 | 1 |
SM100, MS100 | solar | 163 | solarpump2 | pump 2 (PS4) | boolean | | False | binary_sensor.solar_pump_2_(PS4) | binary_sensor.solar_solarpump2 | 8 | 0 | 1 | 22 | 1 |
SM100, MS100 | solar | 163 | solarpump2mod | pump 2 modulation (PS4) | uint8 (>=0<=100) | % | False | sensor.solar_pump_2_modulation_(PS4) | sensor.solar_solarpump2mod | 8 | 0 | 1 | 23 | 1 |
SM100, MS100 | solar | 163 | cyl2bottomtemp | second cylinder bottom temperature (TS5) | int16 (>=-3199<=3199) | C | False | sensor.solar_second_cylinder_bottom_temperature_(TS5) | sensor.solar_cyl2bottomtemp | 8 | 0 | 1/10 | 24 | 1 |
SM100, MS100 | solar | 163 | heatexchangertemp | heat exchanger temperature (TS6) | int16 (>=-3199<=3199) | C | False | sensor.solar_heat_exchanger_temperature_(TS6) | sensor.solar_heatexchangertemp | 8 | 0 | 1/10 | 25 | 1 |
SM100, MS100 | solar | 163 | cylpumpmod | cylinder pump modulation (PS5) | uint8 (>=0<=100) | % | False | sensor.solar_cylinder_pump_modulation_(PS5) | sensor.solar_cylpumpmod | 8 | 0 | 1 | 26 | 1 |
SM100, MS100 | solar | 163 | valvestatus | valve status | boolean | | False | binary_sensor.solar_valve_status | binary_sensor.solar_valvestatus | 8 | 0 | 1 | 27 | 1 |
SM100, MS100 | solar | 163 | vs1status | valve status VS1 | boolean | | False | binary_sensor.solar_valve_status_VS1 | binary_sensor.solar_vs1status | 8 | 0 | 1 | 28 | 1 |
SM100, MS100 | solar | 163 | collectormaxtemp | maximum collector temperature | uint8 (>=0<=254) | C | True | number.solar_maximum_collector_temperature | number.solar_collectormaxtemp | 8 | 0 | 1 | 29 | 1 |
SM100, MS100 | solar | 163 | collectormintemp | minimum collector temperature | uint8 (>=0<=254) | C | True | number.solar_minimum_collector_temperature | number.solar_collectormintemp | 8 | 0 | 1 | 30 | 1 |
SM100, MS100 | solar | 163 | energylasthour | energy last hour | uint24 (>=0<=1677721) | Wh | False | sensor.solar_energy_last_hour | sensor.solar_energylasthour | 8 | 0 | 1/10 | 13 | 2 |
SM100, MS100 | solar | 163 | energytoday | total energy today | uint24 (>=0<=16777213) | Wh | False | sensor.solar_total_energy_today | sensor.solar_energytoday | 8 | 0 | 1 | 31 | 2 |
SM100, MS100 | solar | 163 | energytotal | total energy | uint24 (>=0<=1677721) | kWh | False | sensor.solar_total_energy | sensor.solar_energytotal | 8 | 0 | 1/10 | 33 | 2 |
SM100, MS100 | solar | 163 | pump2worktime | pump 2 working time | time (>=0<=16777213) | minutes | False | sensor.solar_pump_2_working_time | sensor.solar_pump2worktime | 8 | 0 | 1 | 35 | 2 |
SM100, MS100 | solar | 163 | m1worktime | differential control working time | time (>=0<=16777213) | minutes | False | sensor.solar_differential_control_working_time | sensor.solar_m1worktime | 8 | 0 | 1 | 37 | 2 |
SM100, MS100 | solar | 163 | heattransfersystem | heattransfer system | boolean | | True | switch.solar_heattransfer_system | switch.solar_heattransfersystem | 8 | 0 | 1 | 39 | 1 |
SM100, MS100 | solar | 163 | externalcyl | external cylinder | boolean | | True | switch.solar_external_cylinder | switch.solar_externalcyl | 8 | 0 | 1 | 40 | 1 |
SM100, MS100 | solar | 163 | thermaldisinfect | thermal disinfection | boolean | | True | switch.solar_thermal_disinfection | switch.solar_thermaldisinfect | 8 | 0 | 1 | 41 | 1 |
SM100, MS100 | solar | 163 | heatmetering | heatmetering | boolean | | True | switch.solar_heatmetering | switch.solar_heatmetering | 8 | 0 | 1 | 42 | 1 |
SM100, MS100 | solar | 163 | activated | activated | boolean | | True | switch.solar_activated | switch.solar_activated | 8 | 0 | 1 | 43 | 1 |
SM100, MS100 | solar | 163 | solarpumpmode | solar pump mode | enum [constant|pwm|analog] | | True | select.solar_solar_pump_mode | select.solar_solarpumpmode | 8 | 0 | 1 | 44 | 1 |
SM100, MS100 | solar | 163 | solarpumpkick | solar pump kick | boolean | | True | switch.solar_solar_pump_kick | switch.solar_solarpumpkick | 8 | 0 | 1 | 45 | 1 |
SM100, MS100 | solar | 163 | plainwatermode | plain water mode | boolean | | True | switch.solar_plain_water_mode | switch.solar_plainwatermode | 8 | 0 | 1 | 46 | 1 |
SM100, MS100 | solar | 163 | doublematchflow | doublematchflow | boolean | | True | switch.solar_doublematchflow | switch.solar_doublematchflow | 8 | 0 | 1 | 47 | 1 |
SM100, MS100 | solar | 163 | pump2minmod | minimum pump 2 modulation | uint8 (>=0<=100) | % | True | number.solar_minimum_pump_2_modulation | number.solar_pump2minmod | 8 | 0 | 1 | 48 | 1 |
SM100, MS100 | solar | 163 | turnondiff2 | pump 2 turn on difference | uint8 (>=0<=25) | C | True | number.solar_pump_2_turn_on_difference | number.solar_turnondiff2 | 8 | 0 | 1/10 | 49 | 1 |
SM100, MS100 | solar | 163 | turnoffdiff2 | pump 2 turn off difference | uint8 (>=0<=25) | C | True | number.solar_pump_2_turn_off_difference | number.solar_turnoffdiff2 | 8 | 0 | 1/10 | 50 | 1 |
SM100, MS100 | solar | 163 | pump2kick | pump kick 2 | boolean | | True | switch.solar_pump_kick_2 | switch.solar_pump2kick | 8 | 0 | 1 | 51 | 1 |
SM100, MS100 | solar | 163 | climatezone | climate zone | uint8 (>=0<=254) | | True | number.solar_climate_zone | number.solar_climatezone | 8 | 0 | 1 | 52 | 1 |
SM100, MS100 | solar | 163 | collector1area | collector 1 area | uint16 (>=0<=3199) | m² | True | number.solar_collector_1_area | number.solar_collector1area | 8 | 0 | 1/10 | 53 | 1 |
SM100, MS100 | solar | 163 | collector1type | collector 1 type | enum [flat|vacuum] | | True | select.solar_collector_1_type | select.solar_collector1type | 8 | 0 | 1 | 54 | 1 |
SM100, MS100 | solar | 163 | collector2area | collector 2 area | uint16 (>=0<=3199) | m² | True | number.solar_collector_2_area | number.solar_collector2area | 8 | 0 | 1/10 | 55 | 1 |
SM100, MS100 | solar | 163 | collector2type | collector 2 type | enum [flat|vacuum] | | True | select.solar_collector_2_type | select.solar_collector2type | 8 | 0 | 1 | 56 | 1 |
SM100, MS100 | solar | 163 | cylpriority | cylinder priority | enum [cyl 1|cyl 2] | | True | select.solar_cylinder_priority | select.solar_cylpriority | 8 | 0 | 1 | 57 | 1 |
SM100, MS100 | solar | 163 | heatcntflowtemp | heat counter flow temperature | uint16 (>=0<=3199) | C | False | sensor.solar_heat_counter_flow_temperature | sensor.solar_heatcntflowtemp | 8 | 0 | 1/10 | 58 | 1 |
SM100, MS100 | solar | 163 | heatcntrettemp | heat counter return temperature | uint16 (>=0<=3199) | C | False | sensor.solar_heat_counter_return_temperature | sensor.solar_heatcntrettemp | 8 | 0 | 1/10 | 59 | 1 |
SM100, MS100 | solar | 163 | heatcnt | heat counter impulses | uint8 (>=0<=254) | | False | sensor.solar_heat_counter_impulses | sensor.solar_heatcnt | 8 | 0 | 1 | 60 | 1 |
SM100, MS100 | solar | 163 | swapflowtemp | swap flow temperature (TS14) | uint16 (>=0<=3199) | C | False | sensor.solar_swap_flow_temperature_(TS14) | sensor.solar_swapflowtemp | 8 | 0 | 1/10 | 61 | 1 |
SM100, MS100 | solar | 163 | swaprettemp | swap return temperature (TS15) | uint16 (>=0<=3199) | C | False | sensor.solar_swap_return_temperature_(TS15) | sensor.solar_swaprettemp | 8 | 0 | 1/10 | 62 | 1 |
SM200, MS200 | solar | 164 | collectortemp | collector temperature (TS1) | int16 (>=-3199<=3199) | C | False | sensor.solar_collector_temperature_(TS1) | sensor.solar_collectortemp | 8 | 0 | 1/10 | 0 | 1 |
SM200, MS200 | solar | 164 | cylbottomtemp | cylinder bottom temperature (TS2) | int16 (>=-3199<=3199) | C | False | sensor.solar_cylinder_bottom_temperature_(TS2) | sensor.solar_cylbottomtemp | 8 | 0 | 1/10 | 1 | 1 |
SM200, MS200 | solar | 164 | solarpump | pump (PS1) | boolean | | False | binary_sensor.solar_pump_(PS1) | binary_sensor.solar_solarpump | 8 | 0 | 1 | 2 | 1 |
SM200, MS200 | solar | 164 | pumpworktime | pump working time | time (>=0<=16777213) | minutes | False | sensor.solar_pump_working_time | sensor.solar_pumpworktime | 8 | 0 | 1 | 3 | 2 |
SM200, MS200 | solar | 164 | cylmaxtemp | maximum cylinder temperature | uint8 (>=0<=254) | C | True | number.solar_maximum_cylinder_temperature | number.solar_cylmaxtemp | 8 | 0 | 1 | 5 | 1 |
SM200, MS200 | solar | 164 | collectorshutdown | collector shutdown | boolean | | False | binary_sensor.solar_collector_shutdown | binary_sensor.solar_collectorshutdown | 8 | 0 | 1 | 6 | 1 |
SM200, MS200 | solar | 164 | cylheated | cyl heated | boolean | | False | binary_sensor.solar_cyl_heated | binary_sensor.solar_cylheated | 8 | 0 | 1 | 7 | 1 |
SM200, MS200 | solar | 164 | solarpumpmod | pump modulation (PS1) | uint8 (>=0<=100) | % | False | sensor.solar_pump_modulation_(PS1) | sensor.solar_solarpumpmod | 8 | 0 | 1 | 8 | 1 |
SM200, MS200 | solar | 164 | pumpminmod | minimum pump modulation | uint8 (>=0<=100) | % | True | number.solar_minimum_pump_modulation | number.solar_pumpminmod | 8 | 0 | 5 | 9 | 1 |
SM200, MS200 | solar | 164 | turnondiff | pump turn on difference | uint8 (>=0<=25) | C | True | number.solar_pump_turn_on_difference | number.solar_turnondiff | 8 | 0 | 1/10 | 10 | 1 |
SM200, MS200 | solar | 164 | turnoffdiff | pump turn off difference | uint8 (>=0<=25) | C | True | number.solar_pump_turn_off_difference | number.solar_turnoffdiff | 8 | 0 | 1/10 | 11 | 1 |
SM200, MS200 | solar | 164 | collector2temp | collector 2 temperature (TS7) | int16 (>=-3199<=3199) | C | False | sensor.solar_collector_2_temperature_(TS7) | sensor.solar_collector2temp | 8 | 0 | 1/10 | 20 | 1 |
SM200, MS200 | solar | 164 | cylmiddletemp | cylinder middle temperature (TS3) | int16 (>=-3199<=3199) | C | False | sensor.solar_cylinder_middle_temperature_(TS3) | sensor.solar_cylmiddletemp | 8 | 0 | 1/10 | 17 | 1 |
SM200, MS200 | solar | 164 | retheatassist | return temperature heat assistance (TS4) | int16 (>=-3199<=3199) | C | False | sensor.solar_return_temperature_heat_assistance_(TS4) | sensor.solar_retheatassist | 8 | 0 | 1/10 | 18 | 1 |
SM200, MS200 | solar | 164 | heatassistvalve | heat assistance valve (M1) | boolean | | False | binary_sensor.solar_heat_assistance_valve_(M1) | binary_sensor.solar_heatassistvalve | 8 | 0 | 1 | 19 | 1 |
SM200, MS200 | solar | 164 | heatassistpower | heat assistance valve power (M1) | uint8 (>=0<=100) | % | False | sensor.solar_heat_assistance_valve_power_(M1) | sensor.solar_heatassistpower | 8 | 0 | 1 | 21 | 1 |
SM200, MS200 | solar | 164 | solarpump2 | pump 2 (PS4) | boolean | | False | binary_sensor.solar_pump_2_(PS4) | binary_sensor.solar_solarpump2 | 8 | 0 | 1 | 22 | 1 |
SM200, MS200 | solar | 164 | solarpump2mod | pump 2 modulation (PS4) | uint8 (>=0<=100) | % | False | sensor.solar_pump_2_modulation_(PS4) | sensor.solar_solarpump2mod | 8 | 0 | 1 | 23 | 1 |
SM200, MS200 | solar | 164 | cyl2bottomtemp | second cylinder bottom temperature (TS5) | int16 (>=-3199<=3199) | C | False | sensor.solar_second_cylinder_bottom_temperature_(TS5) | sensor.solar_cyl2bottomtemp | 8 | 0 | 1/10 | 24 | 1 |
SM200, MS200 | solar | 164 | heatexchangertemp | heat exchanger temperature (TS6) | int16 (>=-3199<=3199) | C | False | sensor.solar_heat_exchanger_temperature_(TS6) | sensor.solar_heatexchangertemp | 8 | 0 | 1/10 | 25 | 1 |
SM200, MS200 | solar | 164 | cylpumpmod | cylinder pump modulation (PS5) | uint8 (>=0<=100) | % | False | sensor.solar_cylinder_pump_modulation_(PS5) | sensor.solar_cylpumpmod | 8 | 0 | 1 | 26 | 1 |
SM200, MS200 | solar | 164 | valvestatus | valve status | boolean | | False | binary_sensor.solar_valve_status | binary_sensor.solar_valvestatus | 8 | 0 | 1 | 27 | 1 |
SM200, MS200 | solar | 164 | vs1status | valve status VS1 | boolean | | False | binary_sensor.solar_valve_status_VS1 | binary_sensor.solar_vs1status | 8 | 0 | 1 | 28 | 1 |
SM200, MS200 | solar | 164 | collectormaxtemp | maximum collector temperature | uint8 (>=0<=254) | C | True | number.solar_maximum_collector_temperature | number.solar_collectormaxtemp | 8 | 0 | 1 | 29 | 1 |
SM200, MS200 | solar | 164 | collectormintemp | minimum collector temperature | uint8 (>=0<=254) | C | True | number.solar_minimum_collector_temperature | number.solar_collectormintemp | 8 | 0 | 1 | 30 | 1 |
SM200, MS200 | solar | 164 | energylasthour | energy last hour | uint24 (>=0<=1677721) | Wh | False | sensor.solar_energy_last_hour | sensor.solar_energylasthour | 8 | 0 | 1/10 | 13 | 2 |
SM200, MS200 | solar | 164 | energytoday | total energy today | uint24 (>=0<=16777213) | Wh | False | sensor.solar_total_energy_today | sensor.solar_energytoday | 8 | 0 | 1 | 31 | 2 |
SM200, MS200 | solar | 164 | energytotal | total energy | uint24 (>=0<=1677721) | kWh | False | sensor.solar_total_energy | sensor.solar_energytotal | 8 | 0 | 1/10 | 33 | 2 |
SM200, MS200 | solar | 164 | pump2worktime | pump 2 working time | time (>=0<=16777213) | minutes | False | sensor.solar_pump_2_working_time | sensor.solar_pump2worktime | 8 | 0 | 1 | 35 | 2 |
SM200, MS200 | solar | 164 | m1worktime | differential control working time | time (>=0<=16777213) | minutes | False | sensor.solar_differential_control_working_time | sensor.solar_m1worktime | 8 | 0 | 1 | 37 | 2 |
SM200, MS200 | solar | 164 | heattransfersystem | heattransfer system | boolean | | True | switch.solar_heattransfer_system | switch.solar_heattransfersystem | 8 | 0 | 1 | 39 | 1 |
SM200, MS200 | solar | 164 | externalcyl | external cylinder | boolean | | True | switch.solar_external_cylinder | switch.solar_externalcyl | 8 | 0 | 1 | 40 | 1 |
SM200, MS200 | solar | 164 | thermaldisinfect | thermal disinfection | boolean | | True | switch.solar_thermal_disinfection | switch.solar_thermaldisinfect | 8 | 0 | 1 | 41 | 1 |
SM200, MS200 | solar | 164 | heatmetering | heatmetering | boolean | | True | switch.solar_heatmetering | switch.solar_heatmetering | 8 | 0 | 1 | 42 | 1 |
SM200, MS200 | solar | 164 | activated | activated | boolean | | True | switch.solar_activated | switch.solar_activated | 8 | 0 | 1 | 43 | 1 |
SM200, MS200 | solar | 164 | solarpumpmode | solar pump mode | enum [constant|pwm|analog] | | True | select.solar_solar_pump_mode | select.solar_solarpumpmode | 8 | 0 | 1 | 44 | 1 |
SM200, MS200 | solar | 164 | solarpumpkick | solar pump kick | boolean | | True | switch.solar_solar_pump_kick | switch.solar_solarpumpkick | 8 | 0 | 1 | 45 | 1 |
SM200, MS200 | solar | 164 | plainwatermode | plain water mode | boolean | | True | switch.solar_plain_water_mode | switch.solar_plainwatermode | 8 | 0 | 1 | 46 | 1 |
SM200, MS200 | solar | 164 | doublematchflow | doublematchflow | boolean | | True | switch.solar_doublematchflow | switch.solar_doublematchflow | 8 | 0 | 1 | 47 | 1 |
SM200, MS200 | solar | 164 | pump2minmod | minimum pump 2 modulation | uint8 (>=0<=100) | % | True | number.solar_minimum_pump_2_modulation | number.solar_pump2minmod | 8 | 0 | 1 | 48 | 1 |
SM200, MS200 | solar | 164 | turnondiff2 | pump 2 turn on difference | uint8 (>=0<=25) | C | True | number.solar_pump_2_turn_on_difference | number.solar_turnondiff2 | 8 | 0 | 1/10 | 49 | 1 |
SM200, MS200 | solar | 164 | turnoffdiff2 | pump 2 turn off difference | uint8 (>=0<=25) | C | True | number.solar_pump_2_turn_off_difference | number.solar_turnoffdiff2 | 8 | 0 | 1/10 | 50 | 1 |
SM200, MS200 | solar | 164 | pump2kick | pump kick 2 | boolean | | True | switch.solar_pump_kick_2 | switch.solar_pump2kick | 8 | 0 | 1 | 51 | 1 |
SM200, MS200 | solar | 164 | climatezone | climate zone | uint8 (>=0<=254) | | True | number.solar_climate_zone | number.solar_climatezone | 8 | 0 | 1 | 52 | 1 |
SM200, MS200 | solar | 164 | collector1area | collector 1 area | uint16 (>=0<=3199) | m² | True | number.solar_collector_1_area | number.solar_collector1area | 8 | 0 | 1/10 | 53 | 1 |
SM200, MS200 | solar | 164 | collector1type | collector 1 type | enum [flat|vacuum] | | True | select.solar_collector_1_type | select.solar_collector1type | 8 | 0 | 1 | 54 | 1 |
SM200, MS200 | solar | 164 | collector2area | collector 2 area | uint16 (>=0<=3199) | m² | True | number.solar_collector_2_area | number.solar_collector2area | 8 | 0 | 1/10 | 55 | 1 |
SM200, MS200 | solar | 164 | collector2type | collector 2 type | enum [flat|vacuum] | | True | select.solar_collector_2_type | select.solar_collector2type | 8 | 0 | 1 | 56 | 1 |
SM200, MS200 | solar | 164 | cylpriority | cylinder priority | enum [cyl 1|cyl 2] | | True | select.solar_cylinder_priority | select.solar_cylpriority | 8 | 0 | 1 | 57 | 1 |
SM200, MS200 | solar | 164 | heatcntflowtemp | heat counter flow temperature | uint16 (>=0<=3199) | C | False | sensor.solar_heat_counter_flow_temperature | sensor.solar_heatcntflowtemp | 8 | 0 | 1/10 | 58 | 1 |
SM200, MS200 | solar | 164 | heatcntrettemp | heat counter return temperature | uint16 (>=0<=3199) | C | False | sensor.solar_heat_counter_return_temperature | sensor.solar_heatcntrettemp | 8 | 0 | 1/10 | 59 | 1 |
SM200, MS200 | solar | 164 | heatcnt | heat counter impulses | uint8 (>=0<=254) | | False | sensor.solar_heat_counter_impulses | sensor.solar_heatcnt | 8 | 0 | 1 | 60 | 1 |
SM200, MS200 | solar | 164 | swapflowtemp | swap flow temperature (TS14) | uint16 (>=0<=3199) | C | False | sensor.solar_swap_flow_temperature_(TS14) | sensor.solar_swapflowtemp | 8 | 0 | 1/10 | 61 | 1 |
SM200, MS200 | solar | 164 | swaprettemp | swap return temperature (TS15) | uint16 (>=0<=3199) | C | False | sensor.solar_swap_return_temperature_(TS15) | sensor.solar_swaprettemp | 8 | 0 | 1/10 | 62 | 1 |
HP Module | heatpump | 252 | airhumidity | relative air humidity | uint8 (>=0<=100) | % | False | sensor.heatpump_relative_air_humidity | sensor.heatpump_airhumidity | 9 | 0 | 1 | 0 | 1 |
HP Module | heatpump | 252 | dewtemperature | dew point temperature | uint8 (>=0<=254) | C | False | sensor.heatpump_dew_point_temperature | sensor.heatpump_dewtemperature | 9 | 0 | 1 | 1 | 1 |
HP Module | heatpump | 252 | curflowtemp | current flow temperature | int16 (>=-3199<=3199) | C | False | sensor.heatpump_current_flow_temperature | sensor.heatpump_curflowtemp | 9 | 0 | 1/10 | 2 | 1 |
HP Module | heatpump | 252 | rettemp | return temperature | int16 (>=-3199<=3199) | C | False | sensor.heatpump_return_temperature | sensor.heatpump_rettemp | 9 | 0 | 1/10 | 3 | 1 |
HP Module | heatpump | 252 | sysrettemp | system return temperature | int16 (>=-3199<=3199) | C | False | sensor.heatpump_system_return_temperature | sensor.heatpump_sysrettemp | 9 | 0 | 1/10 | 4 | 1 |
HP Module | heatpump | 252 | hpta4 | drain pan temp (TA4) | int16 (>=-3199<=3199) | C | False | sensor.heatpump_drain_pan_temp_(TA4) | sensor.heatpump_hpta4 | 9 | 0 | 1/10 | 5 | 1 |
HP Module | heatpump | 252 | hptr1 | compressor temperature (TR1) | int16 (>=-3199<=3199) | C | False | sensor.heatpump_compressor_temperature_(TR1) | sensor.heatpump_hptr1 | 9 | 0 | 1/10 | 6 | 1 |
HP Module | heatpump | 252 | hptr3 | refrigerant temperature liquid side (condenser output) (TR3) | int16 (>=-3199<=3199) | C | False | sensor.heatpump_refrigerant_temperature_liquid_side_(condenser_output)_(TR3) | sensor.heatpump_hptr3 | 9 | 0 | 1/10 | 7 | 1 |
HP Module | heatpump | 252 | hptr4 | evaporator inlet temperature (TR4) | int16 (>=-3199<=3199) | C | False | sensor.heatpump_evaporator_inlet_temperature_(TR4) | sensor.heatpump_hptr4 | 9 | 0 | 1/10 | 8 | 1 |
HP Module | heatpump | 252 | hptr5 | compressor inlet temperature (TR5) | int16 (>=-3199<=3199) | C | False | sensor.heatpump_compressor_inlet_temperature_(TR5) | sensor.heatpump_hptr5 | 9 | 0 | 1/10 | 9 | 1 |
HP Module | heatpump | 252 | hptr6 | compressor outlet temperature (TR6) | int16 (>=-3199<=3199) | C | False | sensor.heatpump_compressor_outlet_temperature_(TR6) | sensor.heatpump_hptr6 | 9 | 0 | 1/10 | 10 | 1 |
HP Module | heatpump | 252 | hptl2 | air inlet temperature (TL2) | int16 (>=-3199<=3199) | C | False | sensor.heatpump_air_inlet_temperature_(TL2) | sensor.heatpump_hptl2 | 9 | 0 | 1/10 | 11 | 1 |
HP Module | heatpump | 252 | hppl1 | low pressure side temperature (PL1) | int16 (>=-3199<=3199) | C | False | sensor.heatpump_low_pressure_side_temperature_(PL1) | sensor.heatpump_hppl1 | 9 | 0 | 1/10 | 12 | 1 |
HP Module | heatpump | 252 | hpph1 | high pressure side temperature (PH1) | int16 (>=-3199<=3199) | C | False | sensor.heatpump_high_pressure_side_temperature_(PH1) | sensor.heatpump_hpph1 | 9 | 0 | 1/10 | 13 | 1 |
HP Module | heatpump | 252 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.heatpump_heating_pump_modulation | sensor.heatpump_heatingpumpmod | 9 | 0 | 1 | 14 | 1 |
HP Module | heatpump | 252 | hpcompspd | compressor speed | uint8 (>=0<=100) | % | False | sensor.heatpump_compressor_speed | sensor.heatpump_hpcompspd | 9 | 0 | 1 | 15 | 1 |
HP Module | heatpump | 252 | hybridstrategy | hybrid control strategy | enum [cost optimized|co2 optimized|outside temperature alt.|outside temperature parallel|heatpump prefered|boiler only] | | True | select.heatpump_hybrid_control_strategy | select.heatpump_hybridstrategy | 9 | 0 | 1 | 16 | 1 |
HP Module | heatpump | 252 | lownoisemode | low noise mode | enum [off|reduced output|switch off hp|perm. reduced] | | True | select.heatpump_low_noise_mode | select.heatpump_lownoisemode | 9 | 0 | 1 | 17 | 1 |
HP Module | heatpump | 252 | lownoisestart | low noise starttime | uint8 (>=0<=23) | | True | number.heatpump_low_noise_starttime | number.heatpump_lownoisestart | 9 | 0 | 1 | 18 | 1 |
HP Module | heatpump | 252 | lownoisestop | low noise stoptime | uint8 (>=0<=23) | | True | number.heatpump_low_noise_stoptime | number.heatpump_lownoisestop | 9 | 0 | 1 | 19 | 1 |
HP Module | heatpump | 252 | hybriddhw | hybrid DHW | enum [eco|high comfort] | | True | select.heatpump_hybrid_DHW | select.heatpump_hybriddhw | 9 | 0 | 1 | 20 | 1 |
HP Module | heatpump | 252 | energypricegas | energy price gas | uint8 (>=0<=254) | | True | number.heatpump_energy_price_gas | number.heatpump_energypricegas | 9 | 0 | 1 | 21 | 1 |
HP Module | heatpump | 252 | energypriceel | energy price electric | uint8 (>=0<=254) | | True | number.heatpump_energy_price_electric | number.heatpump_energypriceel | 9 | 0 | 1 | 22 | 1 |
HP Module | heatpump | 252 | energyfeedpv | feed in PV | uint8 (>=0<=254) | | True | number.heatpump_feed_in_PV | number.heatpump_energyfeedpv | 9 | 0 | 1 | 23 | 1 |
HP Module | heatpump | 252 | switchovertemp | outside switchover temperature | int8 (>=-126<=126) | | True | number.heatpump_outside_switchover_temperature | number.heatpump_switchovertemp | 9 | 0 | 1 | 24 | 1 |
HP Module | heatpump | 252 | airpurgemode | air purge mode | boolean | | True | switch.heatpump_air_purge_mode | switch.heatpump_airpurgemode | 9 | 0 | 1 | 25 | 1 |
HP Module | heatpump | 252 | heatpumpoutput | heatpump output | uint8 (>=0<=100) | % | True | number.heatpump_heatpump_output | number.heatpump_heatpumpoutput | 9 | 0 | 1 | 26 | 1 |
HP Module | heatpump | 252 | coolingcircuit | cooling circuit | boolean | | True | switch.heatpump_cooling_circuit | switch.heatpump_coolingcircuit | 9 | 0 | 1 | 27 | 1 |
HP Module | heatpump | 252 | compstartmod | compressor start modulation | uint8 (>=0<=100) | % | True | number.heatpump_compressor_start_modulation | number.heatpump_compstartmod | 9 | 0 | 1 | 28 | 1 |
HP Module | heatpump | 252 | heatdrainpan | heat drain pan | boolean | | True | switch.heatpump_heat_drain_pan | switch.heatpump_heatdrainpan | 9 | 0 | 1 | 29 | 1 |
HP Module | heatpump | 252 | heatcable | heating cable | boolean | | True | switch.heatpump_heating_cable | switch.heatpump_heatcable | 9 | 0 | 1 | 30 | 1 |
HP Module | heatpump | 252 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.heatpump_total_energy | sensor.heatpump_nrgtotal | 9 | 0 | 1/100 | 31 | 2 |
HP Module | heatpump | 252 | nrg | energy | uint24 (>=0<=167772) | kWh | False | sensor.heatpump_dhw_energy | sensor.heatpump_dhw_nrg | 9 | 9 | 1/100 | 0 | 2 |
HP Module | heatpump | 252 | nrgheat | energy heating | uint24 (>=0<=167772) | kWh | False | sensor.heatpump_energy_heating | sensor.heatpump_nrgheat | 9 | 0 | 1/100 | 33 | 2 |
HP Module | heatpump | 252 | metertotal | meter total | uint24 (>=0<=167772) | kWh | False | sensor.heatpump_meter_total | sensor.heatpump_metertotal | 9 | 0 | 1/100 | 35 | 2 |
HP Module | heatpump | 252 | metercomp | meter compressor | uint24 (>=0<=167772) | kWh | False | sensor.heatpump_meter_compressor | sensor.heatpump_metercomp | 9 | 0 | 1/100 | 37 | 2 |
HP Module | heatpump | 252 | metereheat | meter e-heater | uint24 (>=0<=167772) | kWh | False | sensor.heatpump_meter_e-heater | sensor.heatpump_metereheat | 9 | 0 | 1/100 | 39 | 2 |
HP Module | heatpump | 252 | meterheat | meter heating | uint24 (>=0<=167772) | kWh | False | sensor.heatpump_meter_heating | sensor.heatpump_meterheat | 9 | 0 | 1/100 | 41 | 2 |
HP Module | heatpump | 252 | meter | meter | uint24 (>=0<=167772) | kWh | False | sensor.heatpump_dhw_meter | sensor.heatpump_dhw_meter | 9 | 9 | 1/100 | 2 | 2 |
Hybrid Manager HM200 | heatpump | 248 | airhumidity | relative air humidity | uint8 (>=0<=100) | % | False | sensor.heatpump_relative_air_humidity | sensor.heatpump_airhumidity | 9 | 0 | 1 | 0 | 1 |
Hybrid Manager HM200 | heatpump | 248 | dewtemperature | dew point temperature | uint8 (>=0<=254) | C | False | sensor.heatpump_dew_point_temperature | sensor.heatpump_dewtemperature | 9 | 0 | 1 | 1 | 1 |
Hybrid Manager HM200 | heatpump | 248 | curflowtemp | current flow temperature | int16 (>=-3199<=3199) | C | False | sensor.heatpump_current_flow_temperature | sensor.heatpump_curflowtemp | 9 | 0 | 1/10 | 2 | 1 |
Hybrid Manager HM200 | heatpump | 248 | rettemp | return temperature | int16 (>=-3199<=3199) | C | False | sensor.heatpump_return_temperature | sensor.heatpump_rettemp | 9 | 0 | 1/10 | 3 | 1 |
Hybrid Manager HM200 | heatpump | 248 | sysrettemp | system return temperature | int16 (>=-3199<=3199) | C | False | sensor.heatpump_system_return_temperature | sensor.heatpump_sysrettemp | 9 | 0 | 1/10 | 4 | 1 |
Hybrid Manager HM200 | heatpump | 248 | hpta4 | drain pan temp (TA4) | int16 (>=-3199<=3199) | C | False | sensor.heatpump_drain_pan_temp_(TA4) | sensor.heatpump_hpta4 | 9 | 0 | 1/10 | 5 | 1 |
Hybrid Manager HM200 | heatpump | 248 | hptr1 | compressor temperature (TR1) | int16 (>=-3199<=3199) | C | False | sensor.heatpump_compressor_temperature_(TR1) | sensor.heatpump_hptr1 | 9 | 0 | 1/10 | 6 | 1 |
Hybrid Manager HM200 | heatpump | 248 | hptr3 | refrigerant temperature liquid side (condenser output) (TR3) | int16 (>=-3199<=3199) | C | False | sensor.heatpump_refrigerant_temperature_liquid_side_(condenser_output)_(TR3) | sensor.heatpump_hptr3 | 9 | 0 | 1/10 | 7 | 1 |
Hybrid Manager HM200 | heatpump | 248 | hptr4 | evaporator inlet temperature (TR4) | int16 (>=-3199<=3199) | C | False | sensor.heatpump_evaporator_inlet_temperature_(TR4) | sensor.heatpump_hptr4 | 9 | 0 | 1/10 | 8 | 1 |
Hybrid Manager HM200 | heatpump | 248 | hptr5 | compressor inlet temperature (TR5) | int16 (>=-3199<=3199) | C | False | sensor.heatpump_compressor_inlet_temperature_(TR5) | sensor.heatpump_hptr5 | 9 | 0 | 1/10 | 9 | 1 |
Hybrid Manager HM200 | heatpump | 248 | hptr6 | compressor outlet temperature (TR6) | int16 (>=-3199<=3199) | C | False | sensor.heatpump_compressor_outlet_temperature_(TR6) | sensor.heatpump_hptr6 | 9 | 0 | 1/10 | 10 | 1 |
Hybrid Manager HM200 | heatpump | 248 | hptl2 | air inlet temperature (TL2) | int16 (>=-3199<=3199) | C | False | sensor.heatpump_air_inlet_temperature_(TL2) | sensor.heatpump_hptl2 | 9 | 0 | 1/10 | 11 | 1 |
Hybrid Manager HM200 | heatpump | 248 | hppl1 | low pressure side temperature (PL1) | int16 (>=-3199<=3199) | C | False | sensor.heatpump_low_pressure_side_temperature_(PL1) | sensor.heatpump_hppl1 | 9 | 0 | 1/10 | 12 | 1 |
Hybrid Manager HM200 | heatpump | 248 | hpph1 | high pressure side temperature (PH1) | int16 (>=-3199<=3199) | C | False | sensor.heatpump_high_pressure_side_temperature_(PH1) | sensor.heatpump_hpph1 | 9 | 0 | 1/10 | 13 | 1 |
Hybrid Manager HM200 | heatpump | 248 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.heatpump_heating_pump_modulation | sensor.heatpump_heatingpumpmod | 9 | 0 | 1 | 14 | 1 |
Hybrid Manager HM200 | heatpump | 248 | hpcompspd | compressor speed | uint8 (>=0<=100) | % | False | sensor.heatpump_compressor_speed | sensor.heatpump_hpcompspd | 9 | 0 | 1 | 15 | 1 |
Hybrid Manager HM200 | heatpump | 248 | hybridstrategy | hybrid control strategy | enum [cost optimized|co2 optimized|outside temperature alt.|outside temperature parallel|heatpump prefered|boiler only] | | True | select.heatpump_hybrid_control_strategy | select.heatpump_hybridstrategy | 9 | 0 | 1 | 16 | 1 |
Hybrid Manager HM200 | heatpump | 248 | lownoisemode | low noise mode | enum [off|reduced output|switch off hp|perm. reduced] | | True | select.heatpump_low_noise_mode | select.heatpump_lownoisemode | 9 | 0 | 1 | 17 | 1 |
Hybrid Manager HM200 | heatpump | 248 | lownoisestart | low noise starttime | uint8 (>=0<=23) | | True | number.heatpump_low_noise_starttime | number.heatpump_lownoisestart | 9 | 0 | 1 | 18 | 1 |
Hybrid Manager HM200 | heatpump | 248 | lownoisestop | low noise stoptime | uint8 (>=0<=23) | | True | number.heatpump_low_noise_stoptime | number.heatpump_lownoisestop | 9 | 0 | 1 | 19 | 1 |
Hybrid Manager HM200 | heatpump | 248 | hybriddhw | hybrid DHW | enum [eco|high comfort] | | True | select.heatpump_hybrid_DHW | select.heatpump_hybriddhw | 9 | 0 | 1 | 20 | 1 |
Hybrid Manager HM200 | heatpump | 248 | energypricegas | energy price gas | uint8 (>=0<=254) | | True | number.heatpump_energy_price_gas | number.heatpump_energypricegas | 9 | 0 | 1 | 21 | 1 |
Hybrid Manager HM200 | heatpump | 248 | energypriceel | energy price electric | uint8 (>=0<=254) | | True | number.heatpump_energy_price_electric | number.heatpump_energypriceel | 9 | 0 | 1 | 22 | 1 |
Hybrid Manager HM200 | heatpump | 248 | energyfeedpv | feed in PV | uint8 (>=0<=254) | | True | number.heatpump_feed_in_PV | number.heatpump_energyfeedpv | 9 | 0 | 1 | 23 | 1 |
Hybrid Manager HM200 | heatpump | 248 | switchovertemp | outside switchover temperature | int8 (>=-126<=126) | | True | number.heatpump_outside_switchover_temperature | number.heatpump_switchovertemp | 9 | 0 | 1 | 24 | 1 |
Hybrid Manager HM200 | heatpump | 248 | airpurgemode | air purge mode | boolean | | True | switch.heatpump_air_purge_mode | switch.heatpump_airpurgemode | 9 | 0 | 1 | 25 | 1 |
Hybrid Manager HM200 | heatpump | 248 | heatpumpoutput | heatpump output | uint8 (>=0<=100) | % | True | number.heatpump_heatpump_output | number.heatpump_heatpumpoutput | 9 | 0 | 1 | 26 | 1 |
Hybrid Manager HM200 | heatpump | 248 | coolingcircuit | cooling circuit | boolean | | True | switch.heatpump_cooling_circuit | switch.heatpump_coolingcircuit | 9 | 0 | 1 | 27 | 1 |
Hybrid Manager HM200 | heatpump | 248 | compstartmod | compressor start modulation | uint8 (>=0<=100) | % | True | number.heatpump_compressor_start_modulation | number.heatpump_compstartmod | 9 | 0 | 1 | 28 | 1 |
Hybrid Manager HM200 | heatpump | 248 | heatdrainpan | heat drain pan | boolean | | True | switch.heatpump_heat_drain_pan | switch.heatpump_heatdrainpan | 9 | 0 | 1 | 29 | 1 |
Hybrid Manager HM200 | heatpump | 248 | heatcable | heating cable | boolean | | True | switch.heatpump_heating_cable | switch.heatpump_heatcable | 9 | 0 | 1 | 30 | 1 |
Hybrid Manager HM200 | heatpump | 248 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.heatpump_total_energy | sensor.heatpump_nrgtotal | 9 | 0 | 1/100 | 31 | 2 |
Hybrid Manager HM200 | heatpump | 248 | nrg | energy | uint24 (>=0<=167772) | kWh | False | sensor.heatpump_dhw_energy | sensor.heatpump_dhw_nrg | 9 | 9 | 1/100 | 0 | 2 |
Hybrid Manager HM200 | heatpump | 248 | nrgheat | energy heating | uint24 (>=0<=167772) | kWh | False | sensor.heatpump_energy_heating | sensor.heatpump_nrgheat | 9 | 0 | 1/100 | 33 | 2 |
Hybrid Manager HM200 | heatpump | 248 | metertotal | meter total | uint24 (>=0<=167772) | kWh | False | sensor.heatpump_meter_total | sensor.heatpump_metertotal | 9 | 0 | 1/100 | 35 | 2 |
Hybrid Manager HM200 | heatpump | 248 | metercomp | meter compressor | uint24 (>=0<=167772) | kWh | False | sensor.heatpump_meter_compressor | sensor.heatpump_metercomp | 9 | 0 | 1/100 | 37 | 2 |
Hybrid Manager HM200 | heatpump | 248 | metereheat | meter e-heater | uint24 (>=0<=167772) | kWh | False | sensor.heatpump_meter_e-heater | sensor.heatpump_metereheat | 9 | 0 | 1/100 | 39 | 2 |
Hybrid Manager HM200 | heatpump | 248 | meterheat | meter heating | uint24 (>=0<=167772) | kWh | False | sensor.heatpump_meter_heating | sensor.heatpump_meterheat | 9 | 0 | 1/100 | 41 | 2 |
Hybrid Manager HM200 | heatpump | 248 | meter | meter | uint24 (>=0<=167772) | kWh | False | sensor.heatpump_dhw_meter | sensor.heatpump_dhw_meter | 9 | 9 | 1/100 | 2 | 2 |
WM10 | switch | 71 | activated | activated | boolean | | False | binary_sensor.switch_activated | binary_sensor.switch_activated | 11 | 0 | 1 | 0 | 1 |
WM10 | switch | 71 | flowtemphc | flow temperature (TC1) | uint16 (>=0<=3199) | C | False | sensor.switch_flow_temperature_(TC1) | sensor.switch_flowtemphc | 11 | 0 | 1/10 | 1 | 1 |
WM10 | switch | 71 | status | status | int8 (>=-126<=126) | | False | sensor.switch_status | sensor.switch_status | 11 | 0 | 1 | 2 | 1 |
Rego 3000 | controller | 240 | datetime | date/time | string | | False | sensor.controller_date/time | sensor.controller_datetime | 12 | 0 | 1 | 0 | 13 |
EM10 | alert | 74 | setflowtemp | set flow temperature | uint8 (>=0<=254) | C | False | sensor.alert_set_flow_temperature | sensor.alert_setflowtemp | 14 | 0 | 1 | 0 | 1 |
EM10 | alert | 74 | setburnpow | burner set power | uint8 (>=0<=100) | % | False | sensor.alert_burner_set_power | sensor.alert_setburnpow | 14 | 0 | 1 | 1 | 1 |
EM10, EM100 | extension | 243 | flowtempvf | flow temperature in header (T0/Vf) | int16 (>=-3199<=3199) | C | False | sensor.extension_flow_temperature_in_header_(T0/Vf) | sensor.extension_flowtempvf | 15 | 0 | 1/10 | 0 | 1 |
EM10, EM100 | extension | 243 | input | input | uint8 (>=0<=25) | V | False | sensor.extension_input | sensor.extension_input | 15 | 0 | 1/10 | 1 | 1 |
EM10, EM100 | extension | 243 | outpow | output IO1 | uint8 (>=0<=100) | % | False | sensor.extension_output_IO1 | sensor.extension_outpow | 15 | 0 | 1 | 2 | 1 |
EM10, EM100 | extension | 243 | setpower | request power | uint8 (>=0<=100) | % | False | sensor.extension_request_power | sensor.extension_setpower | 15 | 0 | 1 | 3 | 1 |
EM10, EM100 | extension | 243 | setpoint | set temp. | uint8 (>=0<=254) | C | False | sensor.extension_set_temp. | sensor.extension_setpoint | 15 | 0 | 1 | 4 | 1 |
EM10, EM100 | extension | 243 | minv | min volt. | uint8 (>=0<=25) | V | True | number.extension_min_volt. | number.extension_minv | 15 | 0 | 1/10 | 5 | 1 |
EM10, EM100 | extension | 243 | maxv | max volt. | uint8 (>=0<=25) | V | True | number.extension_max_volt. | number.extension_maxv | 15 | 0 | 1/10 | 6 | 1 |
EM10, EM100 | extension | 243 | mint | min temp. | uint8 (>=0<=254) | C | True | number.extension_min_temp. | number.extension_mint | 15 | 0 | 1 | 7 | 1 |
EM10, EM100 | extension | 243 | maxt | max temp. | uint8 (>=0<=254) | C | True | number.extension_max_temp. | number.extension_maxt | 15 | 0 | 1 | 8 | 1 |
EM10, EM100 | extension | 243 | mode | operating mode | uint8 (>=0<=254) | | False | sensor.extension_operating_mode | sensor.extension_mode | 15 | 0 | 1 | 9 | 1 |
T1RF | extension | 220 | flowtempvf | flow temperature in header (T0/Vf) | int16 (>=-3199<=3199) | C | False | sensor.extension_flow_temperature_in_header_(T0/Vf) | sensor.extension_flowtempvf | 15 | 0 | 1/10 | 0 | 1 |
T1RF | extension | 220 | input | input | uint8 (>=0<=25) | V | False | sensor.extension_input | sensor.extension_input | 15 | 0 | 1/10 | 1 | 1 |
T1RF | extension | 220 | outpow | output IO1 | uint8 (>=0<=100) | % | False | sensor.extension_output_IO1 | sensor.extension_outpow | 15 | 0 | 1 | 2 | 1 |
T1RF | extension | 220 | setpower | request power | uint8 (>=0<=100) | % | False | sensor.extension_request_power | sensor.extension_setpower | 15 | 0 | 1 | 3 | 1 |
T1RF | extension | 220 | setpoint | set temp. | uint8 (>=0<=254) | C | False | sensor.extension_set_temp. | sensor.extension_setpoint | 15 | 0 | 1 | 4 | 1 |
T1RF | extension | 220 | minv | min volt. | uint8 (>=0<=25) | V | True | number.extension_min_volt. | number.extension_minv | 15 | 0 | 1/10 | 5 | 1 |
T1RF | extension | 220 | maxv | max volt. | uint8 (>=0<=25) | V | True | number.extension_max_volt. | number.extension_maxv | 15 | 0 | 1/10 | 6 | 1 |
T1RF | extension | 220 | mint | min temp. | uint8 (>=0<=254) | C | True | number.extension_min_temp. | number.extension_mint | 15 | 0 | 1 | 7 | 1 |
T1RF | extension | 220 | maxt | max temp. | uint8 (>=0<=254) | C | True | number.extension_max_temp. | number.extension_maxt | 15 | 0 | 1 | 8 | 1 |
T1RF | extension | 220 | mode | operating mode | uint8 (>=0<=254) | | False | sensor.extension_operating_mode | sensor.extension_mode | 15 | 0 | 1 | 9 | 1 |
Logavent HRV176 | ventilation | 231 | outfresh | outdoor fresh air | int16 (>=-3199<=3199) | C | False | sensor.ventilation_outdoor_fresh_air | sensor.ventilation_outfresh | 18 | 0 | 1/10 | 0 | 1 |
Logavent HRV176 | ventilation | 231 | infresh | indoor fresh air | int16 (>=-3199<=3199) | C | False | sensor.ventilation_indoor_fresh_air | sensor.ventilation_infresh | 18 | 0 | 1/10 | 1 | 1 |
Logavent HRV176 | ventilation | 231 | outexhaust | outdoor exhaust air | int16 (>=-3199<=3199) | C | False | sensor.ventilation_outdoor_exhaust_air | sensor.ventilation_outexhaust | 18 | 0 | 1/10 | 2 | 1 |
Logavent HRV176 | ventilation | 231 | inexhaust | indoor exhaust air | int16 (>=-3199<=3199) | C | False | sensor.ventilation_indoor_exhaust_air | sensor.ventilation_inexhaust | 18 | 0 | 1/10 | 3 | 1 |
Logavent HRV176 | ventilation | 231 | ventinspeed | in blower speed | uint8 (>=0<=100) | % | False | sensor.ventilation_in_blower_speed | sensor.ventilation_ventinspeed | 18 | 0 | 1 | 4 | 1 |
Logavent HRV176 | ventilation | 231 | ventoutspeed | out blower speed | uint8 (>=0<=100) | % | False | sensor.ventilation_out_blower_speed | sensor.ventilation_ventoutspeed | 18 | 0 | 1 | 5 | 1 |
Logavent HRV176 | ventilation | 231 | ventmode | ventilation mode | enum [auto|off|L1|L2|L3|L4|demand|sleep|intense|bypass|party|fireplace] | | True | select.ventilation_ventilation_mode | select.ventilation_ventmode | 18 | 0 | 1 | 6 | 1 |
Logavent HRV176 | ventilation | 231 | airquality | air quality (voc) | uint16 (>=0<=31999) | | False | sensor.ventilation_air_quality_(voc) | sensor.ventilation_airquality | 18 | 0 | 1 | 7 | 1 |
Logavent HRV176 | ventilation | 231 | airhumidity | relative air humidity | uint8 (>=0<=100) | % | False | sensor.ventilation_relative_air_humidity | sensor.ventilation_airhumidity | 18 | 0 | 1 | 8 | 1 |
MP100 | pool | 204 | pooltemp | pool temperature | int16 (>=-3199<=3199) | C | False | sensor.pool_pool_temperature | sensor.pool_pooltemp | 20 | 0 | 1/10 | -1 | 1 |
MP100 | pool | 204 | poolshuntstatus | pool shunt status opening/closing | enum [stopped|opening|closing|open|close] | | False | sensor.pool_pool_shunt_status_opening/closing | sensor.pool_poolshuntstatus | 20 | 0 | 1 | -1 | 1 |
MP100 | pool | 204 | poolshunt | pool shunt open/close (0% = pool / 100% = heat) | uint8 (>=0<=100) | % | False | sensor.pool_pool_shunt_open/close_(0%=_pool/100%=_heat) | sensor.pool_poolshunt | 20 | 0 | 1 | -1 | 1 |