Improvement: Reset alarm and clear alarm history list #1695
Comments
and if there is no active alarm... it also complains. Which I think is pretty obvious. :) |
Thanks, the first command is same as |
yes, let's rename! |
Hmm, i see that maintenance reset also verifies the reset by reading the maintenance message, that is not nessesery for message reset, so maybe better two options? |
yes we have to then. |
This works on bosch 3800i at least...could work on other systems also.
What I noticed sometimes it's not possible to write 255, I wonder if it's somehow related if the alarm is really active or not.
Because in those cases, I can not even reset it on the pump, it does not go away.
controller(0x09) -W-> boiler(0x08), ?(0x05), data: FF (offset 8)
But it seems to work, had alarm on the UI code 3071 and run this custom entity with value 255:
and the alarm went away
controller(0x09) -W-> boiler(0x08), ?(0x05), data: 01 (offset 42)
And this clears the alarm history list from the UI/pump:
with value 1