* File: config.h
* Version: 1.0
* Date: 2017
* License: GPL v3
* Description: Config header for Geiger.Counter.1 firmware
* Project: Geiger.Counter.1, Logging, USB Interface and low power field operations.
*
* Copyright 2017 by Gelidus Research Inc, [email protected]
*
* This program is free software: you can redistribute it and/or modify
* it under the terms of the GNU General Public License as published by
* the Free Software Foundation, either version 3 of the License, or
* (at your option) any later version.
*
* This program is distributed in the hope that it will be useful,
* but WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
* GNU General Public License for more details.
*
* You should have received a copy of the GNU General Public License
* along with this program. If not, see <http://www.gnu.org/licenses/>.
*/
#pragma once
#ifndef F_CPU
#define F_CPU 8000000UL // 8MHz internal clock - only set if the env does not already do it
#endif
#define DEV_CLASS 0x1
#define VER_SW 1.0
#define VER_HW 1.0
// constants for this device
#define P_TUBEVOLFB_PIN PC2 // voltage divider input adc pin
#define P_TUBEVOLFB_R1 10000 // voltage divider resistance used to measure high voltage 10M Ohm
#define P_TUBEVOLFB_R2 47 // voltage divider to measure high voltage 47K Ohm
#define GEIGER_TUBE GEIGER_TUBE_SBM20 //Default Tube
#define WARMUP 0 // initial warm up interval before sensors are ready, use only if needed
#define READ_INTERVAL 5 // interval in seconds to read sensors
// user interaction
#define LONG_PRESS 64 // RTC clock ticks on central button counts as a long press ~ .5 sec
#define SHORT_PRESS 16
#define BACKLIGHT_TIMEOUT 15 // turn back light in 15 seconds of inactivity to conserve power
// geiger tube radiation dose thresholds
#define DOSE_THRESHOLD_LOW 0.11
#define DOSE_THRESHOLD_NORMAL 0.21
#define DOSE_THRESHOLD_HIGH 1.01
#define EEPROM_ADDR_BEGIN 0x00
#define EEPROM_ADDR_END 0x28 //Startup struct 40 bytes
// inverter control
#define INVERTER_DUTY_MIN 100 // inverter duty cycle will not go below 10%
#define INVERTER_DUTY_MAX 800 // inverter duty cycle will not go above 90%
#define INVERTER_FREQUENCY 7000UL // inverter frequency in Hertz
#define INVERTER_THRESHOLD 400 // inverter output voltage target
#define INVERTER_TOLERANCE 2 // tolerance for adjusting the duty cycle to control the voltage
// log settings
#define LOG_FILENAME "gc1.log"
enum {
UI_LOG_INTERVAL_1M,
UI_LOG_INTERVAL_5M,
UI_LOG_INTERVAL_15M,
UI_LOG_INTERVAL_30M,
UI_LOG_INTERVAL_1H,
UI_LOG_INTERVAL_2H,
UI_LOG_INTERVAL_4H,
UI_LOG_INTERVAL_8H,
UI_LOG_INTERVAL_12H,
UI_LOG_INTERVAL_24H,
};
#define CLOCK_12MHZ
#define JSMN_STRICT
//**********FUSES***************
//BODLEVEL = DISABLED
//RSTDISBL = [ ]
//DWEN = [ ]
//SPIEN = [X]
//WDTON = [ ]
//EESAVE = [ ]
//BOOTSZ = 2048W_3800
//BOOTRST = [ ]
//CKDIV8 = [X]
//CKOUT = [ ]
//SUT_CKSEL = INTRCOSC_8MHZ_6CK_14CK_65MS
//EXTENDED = 0xFF
//HIGH = 0xD9
//LOW = 0xE2
//AT+UART_DEF=38400,8,1,0,1
//avrdude -c stk500v2 -p m328p -V -P COMn -U lfuse:w:0xe2:m -U hfuse:w:0xd9:m -U efuse:w:0xff:m