You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
I've been receiving thousands of errors in the HA log, and have noted that the water temperature sensor is continually stale requiring a restart of the Omnilogic Local integration to get a fresh reading.
Error below with diagnostics; any ideas on what may be the issue?
This error originated from a custom integration.
Logger: homeassistant
Source: custom_components/omnilogic_local/sensor.py:193
integration: OmniLogic Local (documentation, issues)
First occurred: 7:40:18 AM (30 occurrences)
Last logged: 7:46:11 AM
Error doing job: Task exception was never retrieved (None)
Traceback (most recent call last):
File "/usr/src/homeassistant/homeassistant/helpers/update_coordinator.py", line 258, in _handle_refresh_interval
await self._async_refresh(log_failures=True, scheduled=True)
File "/usr/src/homeassistant/homeassistant/helpers/update_coordinator.py", line 453, in _async_refresh
self.async_update_listeners()
File "/usr/src/homeassistant/homeassistant/helpers/update_coordinator.py", line 168, in async_update_listeners
update_callback()
File "/config/custom_components/omnilogic_local/entity.py", line 47, in _handle_coordinator_update
self.async_write_ha_state()
File "/usr/src/homeassistant/homeassistant/helpers/entity.py", line 1005, in async_write_ha_state
self._async_write_ha_state()
File "/usr/src/homeassistant/homeassistant/helpers/entity.py", line 1130, in _async_write_ha_state
self.__async_calculate_state()
File "/usr/src/homeassistant/homeassistant/helpers/entity.py", line 1067, in __async_calculate_state
state = self._stringify_state(available)
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
File "/usr/src/homeassistant/homeassistant/helpers/entity.py", line 1011, in _stringify_state
if (state := self.state) is None:
^^^^^^^^^^
File "/usr/src/homeassistant/homeassistant/components/sensor/__init__.py", line 542, in state
value = self.native_value
^^^^^^^^^^^^^^^^^
File "/config/custom_components/omnilogic_local/sensor.py", line 228, in native_value
temp = self.sensed_data.telemetry.water_temp
^^^^^^^^^^^^^^^^
File "/config/custom_components/omnilogic_local/sensor.py", line 187, in sensed_data
return cast(T, self.coordinator.data[self.sensed_system_id])
^^^^^^^^^^^^^^^^^^^^^
File "/config/custom_components/omnilogic_local/sensor.py", line 193, in sensed_system_id
raise NotImplementedError
NotImplementedError
From looking at your config, this is likely caused because you have a water temp sensor named "Chiller Temp" which isn't assigned to a BodyOfWater. This isn't something that I knew could be done (how would you sense the temperature of water if you aren't assigned to any water).
Can you give me a description of what this water temp sensor does so that I can think about how to best support it?
Great catch, this looks to have been the issue; very much appreciate your’ looking into this. I deleted the Chiller Temp sensor, reloaded the device and the repeating errors have cleared. Will continue to monitor.
The Omnilogic and OmniPL have three temperature inputs; two are typically always used for ambient and water temp, and the third is most typically used for a Solar system temperature. I installed a Glacier Chiller a few years ago with a return temp sensor and had hoped to use that third input to monitor and do some automations within HA; the API however has never returned that temp, so I abandoned it and created my own temperature input using an ESP32. I still had the configuration in the Omni there with the temp sensor assigned to the Backyard only, as you can’t assign it to the Heater/Chiller config within the Omni.
If I remember correctly, the API config request will pull in the third sensor definition if enabled when the MSP config is read, but the API won’t return a live reading. There was a request submitted to Hayward maybe a year ago but it’s still functionality that’s never been added to my knowledge.
Thanks again and feel free to mark this as resolved; I’d think my use case would be pretty uncommon and probably not worth modification to the integration.
I've been receiving thousands of errors in the HA log, and have noted that the water temperature sensor is continually stale requiring a restart of the Omnilogic Local integration to get a fresh reading.
Error below with diagnostics; any ideas on what may be the issue?
config_entry-omnilogic_local-e444094b4cd81f54f2adb25fdc924c1c.json
The text was updated successfully, but these errors were encountered: