Special instructions: PIXEL repeatedly in sof error recovery #196

Closed
Tracked by #195
gladky opened this issue May 8, 2018 · 4 comments
Closed
Tracked by #195

Special instructions: PIXEL repeatedly in sof error recovery #196

gladky opened this issue May 8, 2018 · 4 comments

Comments

@gladky
Copy link
Collaborator

gladky commented May 8, 2018

  • Pixel
    • when pixel goes repeatedly in SoftErrorRecovery check DCS. If problem in DCS (sectors turned off) ask DCS shifter to call Pixel DOC. If no problem in DCS call Pixel DOC immediately.
@gladky gladky changed the title Special instructions: repeatedly in sof error recovery Special instructions: PIXEL repeatedly in sof error recovery May 8, 2018
@gladky
Copy link
Collaborator Author

gladky commented May 8, 2018

  1. is this up to date?
  2. shall we include this into expert?

@andreh12
Copy link
Contributor

andreh12 commented May 8, 2018

on 2.: it's already implemented, see

action.addContextSteps("Pixel", "Check DCS",
"If problem in DCS (sectors turned off) ask DCS shifter to call Pixel DOC",
"If no problem in DCS call Pixel DOC immediately");

@gladky
Copy link
Collaborator Author

gladky commented May 8, 2018

Thank you @andreh12 I missed that. Let's wait for PIXEL experts to confirm that it's up to date. Later I will move it to the section "Covered by Expert"

@gladky
Copy link
Collaborator Author

gladky commented May 14, 2018

up to date - confirmed by PIXEL