how to calculate x(qualicty) #6
Comments
I'll be happy to do so. Just give me a little time to get around to it. |
Right, finally have time to get to this. Now, just to clarify: Are you looking for utility functions that return the quality, given for example P and h (Quality_Ph) or functions that take the quality as an input, for example SpecificG_Px? |
right |
OK, finally. I added four quality functions. You can get the qualioty with any combination of T/P with h/s. The saturated properties where added from IAPWS SR1-86(1992). This introduced an alternative Psat correlation, of which I needed the derivative. Interestingly, even though there is next to no difference between this Psat and the one I used, the derivatives are different enough to affect the specific enthalpy of the liquid at Tc to a few decimal places. I therefore included both models and call the new one only in the saturated property methods. I'll tag a new version that will close this issue. |
I am using SteamTable for project,but can't find relate to x(quality) function, could you provide some function relate to quality, like phx ,sat liquid and steam enthalpy and pqh pqs
The text was updated successfully, but these errors were encountered: