Condensed CellML 2.0 rules

This is a selection of rules from CellML 2.0 used as a basis for the CellML 2.0 test set.

General document rules

  • 1.2.1.1 CellML documents must be well-formed XML 1.1.

  • 1.2.2.2 Elements and attributes can only appear where the spec explicitly allows them.

  • 1.2.3.2 CellML elements must not contain character items other than whitespace.

  • 1.2.4.1 All elements must be either in the CellML or the MathML namespace.

  • 1.2.4.2 Unless explicitly stated otherwise, attributes are unnamespaced.

  • 1.2.5 Every element in the CellML namespace may contain an id attribute.

  • 1.3.1.1 Identifiers are only letters, numbers, or underscores.

  • 1.3.1.1 Identifiers must begin with a letter.

  • 1.3.2.1 Integer strings are base ten.

  • 1.3.2.2 Integer string may start with + or -.

  • 1.3.2.3 Integer strings can only contain optional sign, plus one or more digits.

  • 1.3.3.1 Basic real number strings are base ten.

  • 1.3.3.2 Basic real number strings may start with + or -.

  • 1.3.3.3 Basic real number strings may contain a ..

  • 1.3.3.4 Basic real number strings can only contain an optional + or -., an optional ., and one or more digits.

  • 1.3.4.2 Real number strings are a basic real number string, optionally followed by an exponent.

  • 1.3.4.4 The exponent is e or E, followed by an integer string.

Elements

  • 2.1 The top-level element must be a <model>.

  • 2.1.1 A model must have a name attribute.

  • 2.1.1 A model name must be an identifier.

  • 2.1.2.1 A model may contain one or more component elements.

  • 2.1.2.2 A model may contain one or more connection elements.

  • 2.1.2.3 A model may contain an encapsulation element.

  • 2.1.2.4 A model may contain one or more import elements.

  • 2.1.2.5 A model may contain one or more units elements.

  • 2.1.3 A model must not contain more than one encapsulation element.

  • 2.2.1 An import must have an xlink:href attribute.

  • 2.2.1 An import xlink:href must be a valid xlink locator.

  • 2.2.2.1 An import may contain one or more import units elements.

  • 2.2.2.2 An import may contain one or more import component elements.

  • 2.2.3 The imported model must be different from the importing model.

  • 2.3.1 An import units element (<units>) must have a name attribute.

  • 2.3.1 An import units name must be an identifier.

  • 2.3.1 An import units name must not match the name of any other units or import units.

  • 2.3.2 An import units must have a units_ref attribute.

  • 2.3.2 An import units units_ref` must be an identifier.

  • 2.3.2 An import units units_refmust match thenameof aunitsorimport units` in the imported model.

  • Missing rule: An import units name must not match the name of a built-in unit.

  • 2.4.1 An import component element (<component>) must have a name attribute.

  • 2.4.1 An import component name must be an identifier.

  • 2.4.1 An import component name must not match the name of any other component or import component.

  • 2.4.2 An import component must have a component_ref attribute.

  • 2.4.2 An import component component_ref must be an identifier.

  • 2.4.2 An import component component_ref must match the name of a component or import component in the imported model.

  • 2.5.1 A units must have a name attribute.

  • 2.5.1 A units name must be an identifier.

  • 2.5.1 A units name must not match the name of any other units or import units.

  • 2.5.2 A units name must not match the name of a built-in unit.

  • 2.5.3 A units may contain one or more unit elements.

  • 2.6.1 A unit must have a units attribute.

  • 2.6.1 A unit units must be a valid units reference.

  • 2.6.1.2 A unit definition must not be cyclical.

  • 2.6.2.1 A units may have a prefix attribute.

  • 2.6.2.1 A units prefix must be an integer string or a prefix string.

  • 2.6.2.2 A units may have a multiplier attribute.

  • 2.6.2.2 A units multiplier must be a real number string.

  • 2.6.2.3 A units may have an exponent attribute.

  • 2.6.2.3 A units exponent must be a real number string.

  • 2.7.1 A component must have a name attribute.

  • 2.7.1 A component name must be an identifier.

  • 2.7.1 A component name must not match the name of any other component or import component.

  • 2.7.2.1 A component may contain one or more mathml:math elements.

  • 2.7.2.2 A component may contain one or more reset elements.

  • 2.7.2.3 A component may contain one or more variable elements.

  • 2.8.1.1 A variable must have a name attribute.

  • 2.8.1.1 A variable name must be an identifier.

  • 2.8.1.1 A variable name must be unique within the component.

  • 2.8.1.2 A variable must have a units attribute.

  • 2.8.1.2 A variable units must be a valid units reference.

  • 2.8.2.1 A variable may have an interface attribute.

  • 2.8.2.1 A variable interface must be "public", "private", "public_and_private", or "none".

  • 2.8.2.2 A variable may have an initial_value attribute.

  • 2.8.2.2 A variable initial_value must be a number of the name of a local variable.

  • 2.9.1.1 A reset must have a variable attribute.

  • 2.9.1.1 A reset variable must match the name of a variable in the same component.

  • 2.9.1.2 A reset must have a test_variable attribute.

  • 2.9.1.2 A reset test_variable must match the name of a variable in the same component.

  • 2.9.1.3 A reset must have an order attribute.

  • 2.9.1.3 A reset order must be an integer string.

  • 2.9.1.3 A reset order must be unique for all resets on the same variable (including connected variables).

  • 2.9.2.1 A reset must contain exactly one reset_value element.

  • 2.9.2.2 A reset must contain exactly one test_value element.

  • 2.10.1 A test_value must contain exactly one mathml:math element.

  • 2.11.1 A reset_value must contain exactly one mathml:math element.

  • 2.12.1 A mathml:math must contain content MathML.

  • 2.12.2 Only elements from the supported subset are allowed.

  • 2.12.3 All mathml:ci elements must contain the name of a variable in the same component.

  • 2.12.4 All mathml:cn elements must have a cellml:units attribute.

  • 2.12.4 The value of a cellml:units attribute must be a valid units reference.

  • 2.12.5 All mathml:cn elements must be of type "real" or "e-notation".

  • 2.12.5 All mathml:cn elements must be base ten.

  • 2.13.1 An encapsulation may contain one or more component_ref elements.

  • 2.14.1 A component_ref must have a component attribute.

  • 2.14.1 A component_ref component must match the name of a component or an import component.

  • 2.14.1 A component_ref component must be unique.

  • 2.14.2 A component_ref may contain further component_ref elements.

  • 2.15.1 A connection must have a component_1 attribute.

  • 2.15.1 A connection component_1 must match the name of a component or import component.

  • 2.15.2 A connection must have a component_2 attribute.

  • 2.15.2 A connection component_2 must match the name of a component or import component.

  • 2.15.3 A connection component_1 and component_2 cannot have the same value.

  • 2.15.4 For any two components, there can be at most one connection.

  • 2.15.5 A connection may contain one or more map_variables elements.

  • 2.16.1 A map_variables must have a variable_1 attribute.

  • 2.16.1 A map_variables variable_1 must match the name of a variable in component_1.

  • 2.16.2 A map_variables must have a variable_2 attribute.

  • 2.16.2 A map_variables variable_2 must match the name of a variable in component_2.

  • 2.16.3 The pair (variable_1, variable_2) must be unique within the connection.

Interpretation

  • 3.1.1 Each import units or import components creates a distinct infoset.

  • 3.1.2 A units reference in an import element is resolved within its infoset.

  • 3.1.3.1 Connections can be made from local to imported components.

  • 3.1.3.2 Connections to child components in the imported model are maintained, connections to sibiling and/or parents are not.

  • 3.2.1 A units reference must be an identifier.

  • 3.2.2 A units reference must be the name of units defined or imported in the model, or one of the built-in units.

  • 3.3.1.1 The prefix attribute has default value 0.

  • 3.3.1.1 If the prefix is an integer, the "prefix value" is that integer.

  • 3.3.1.1 If the prefix is a string, the "prefix value" is given by the prefix values table.

  • 3.3.1.2 The exponent attribute has default value 1.

  • 3.3.1.3 The multiplier attribute has default value 1.

  • 3.3.3.1 Empty units elements define a new base unit (with exponent 1)

  • 3.10.4 Connections cannot connect two variables twice.

  • 3.10.5 The connection network must not contain any cycles.

  • 3.10.7.1 Connections between sibling components use the public interface.

  • 3.10.7.2 In parent-child relations, the parent variable uses the private interface.

  • 3.10.7.2 In parent-child relations, the child variable uses the public interface.

  • 3.10.9 Connected variables must have compatible units.

  • 3.10.10 If two units differ by a scaling factor, this must be taken into account when evaluating the model's mathematics.

  • Missing rule: Variables can't have value true or false