diff --git a/bundles/org.openhab.binding.teleinfo/README.md b/bundles/org.openhab.binding.teleinfo/README.md
index 7ebd4b22d555c..04b7f27346b3c 100755
--- a/bundles/org.openhab.binding.teleinfo/README.md
+++ b/bundles/org.openhab.binding.teleinfo/README.md
@@ -65,8 +65,8 @@ Once the serial controller added, electricity meters will automatically appear a
| Thing type | Parameter | Meaning | Possible values |
|----------------------|--------------|---------------------------------------|---------------------------------|
| `serialcontroller` | `serialport` | Path to the serial controller | /dev/ttyXXXX, rfc2217://ip:port |
-| `*_electricitymeter` | `adco` | Electricity meter identifier | 12 digits number |
| | `ticMode` | TIC mode | `STANDARD`, `HISTORICAL` (default) |
+| `*_electricitymeter` | `adco` | Electricity meter identifier | 12 digits number |
## Channels
@@ -110,57 +110,83 @@ Channel availability depends on the electricity connection (single or three-phas
### Standard TIC mode
-| Channel | Type | Description | Connection | Mode |
-|----------|---------------------------|----------------------------------------------------------|--------|-------|
-| ngtf | `String` | Provider schedule name | All | All |
-| ltarf | `String` | Current pricing label | All | All |
-| east | `Number:Energy` | Total active energy withdrawn | All | All |
-| easf*XX* | `Number:Energy` | Active energy withdrawn from provider on index | All | All |
-| easd*XX* | `Number:Energy` | Active energy withdrawn from distributor on index | All | All |
-| irms*X* | `Number:ElectricCurrent` | RMS Current on phase *X* | All for , Three-phase for | All |
-| urms*X* | `Number:Potential` | RMS Voltage on phase *X* | All for , Three-phase for | All |
-| pref | `Number:Power` | Reference apparent power | All | All |
-| pcoup | `Number:Power` | Apparent power rupture capacity | All | All |
-| sinsts | `Number:Power` | Instantaneous withdrawn apparent power | Single-phase | All |
-| smaxsn | `Number:Power` | Maximum withdrawn apparent power of the day | Single-phase | All |
-| smaxsnMinus1 | `Number:Power` | Maximum withdrawn apparent power of the previous day | Single-phase | All |
-| ccasn | `Number:Power` | Active charge point N | All | All |
-| ccasnMinus1 | `Number:Power` | Active charge point N-1 | All | All |
-| umoy*X* | `Number:Potential` | Mean Voltage on phase *X* | All for , Three-phase for | All |
-| dpm*X* | `String` | Start of mobile peak period | All | All |
-| fpm*X* | `String` | End of mobile peak period | All | All |
-| msg1 | `String` | Short message | All | All |
-| msg2 | `String` | Very short message | All | All |
-| ntarf | `String` | Index of current pricing | All | All |
-| njourf | `String` | Number of current provider schedule | All | All |
-| njourfPlus1 | `String` | Number of next day provider schedule | All | All |
-| pjourfPlus1 | `String` | Profile of next day provider schedule | All | All |
-| ppointe | `String` | Profile of next rush day | All | All |
-| date | `DateTime` | Date and Time | All | All |
-| smaxsnDate | `DateTime` | Timestamp of SMAXSN value | All | All |
-| smaxsnMinus1Date | `DateTime` | Timestamp of SMAXSN-1 value | All | All |
-| ccasnDate | `DateTime` | Timestamp of CCASN value | All | All |
-| ccasnMinus1Date | `DateTime` | Timestamp of CCASN-1 value | All | All |
-| umoy*X*Date | `DateTime` | Timestamp of UMOY*X* value | All for , Three-phase for | All |
-| dpm*X*Date | `DateTime` | Date of DPM*X* | All | All |
-| fpm*X*Date | `DateTime` | Date of FPM*X* | All | All |
-| relais*X* | `Switch` | relais status ( ) | All | All |
-| sinsts*X* | `Number:Power` | Instantaneous withdrawn apparent power on phase *X* | Three-phase | All |
-| smaxsn*X* | `Number:Power` | Maximum withdrawn apparent power of the day on phase *X* | Three-phase | All |
-| smaxsn*X*Minus1 | `Number:Power` | Maximum withdrawn apparent power on the previous day on phase *X* | Three-phase | All |
-| smaxs*X*nDate | `DateTime` | Timestamp of SMAXSN*X* value | Three-phase | All |
-| smaxsn*X*Minus1Date | `DateTime` | Timestamp of SMAXSN*X*-1 value | Three-phase | All |
-| eait | `Number:Energy` | Total active energy withdrawn | All | All |
-| erq*X* | `Number:Energy` | Active energy withdrawn from provider on index | All | All |
-| sinsti | `Number:Energy` | Active energy withdrawn from distributor on index | All | All |
-| smaxin | `Number:Power` | Maximum injected apparent power of the day | All for , Three-phase for | All |
-| smaxinMinus1 | `Number:Power` | Maximum injected apparent power of the previous day | All for , Three-phase for | All |
-| ccain | `Number:Power` | Injected active charge point N | All | Producer |
-| ccainMinus1 | `Number:Power` | Injected active charge point N-1 | All | Producer |
-| smaxinDate | `DateTime` | Timestamp of SMAXIN value | All | Producer |
-| smaxinMinus1Date | `DateTime` | Timestamp of SMAXIN-1 value | All | Producer |
-| ccainDate | `DateTime` | Timestamp of CCAIN value | All | Producer |
-| ccainMinus1Date | `DateTime` | Timestamp of CCAIN-1 value | All | Producer |
+#### Common channels
+
+The following channels are available on all Linky telemeters in standard TIC mode.
+
+| Channel | Type | Description |
+|---------------------------------|---------------------------|-----------------------------------------------------------------------------|
+| commonLSMGroup#ngtf | `String` | Provider schedule name |
+| commonLSMGroup#ltarf | `String` | Current pricing label |
+| commonLSMGroup#east | `Number:Energy` | Total active energy withdrawn |
+| commonLSMGroup#easf*XX* | `Number:Energy` | Active energy withdrawn from provider on index *XX*, *XX* in {01,...,10} |
+| commonLSMGroup#easd*XX* | `Number:Energy` | Active energy withdrawn from distributor on index *XX*, *XX* in {01,...,04} |
+| commonLSMGroup#irms1 | `Number:ElectricCurrent` | RMS Current on phase 1 |
+| commonLSMGroup#urms1 | `Number:Potential` | RMS Voltage on phase 1 |
+| commonLSMGroup#pref | `Number:Power` | Reference apparent power |
+| commonLSMGroup#pcoup | `Number:Power` | Apparent power rupture capacity |
+| commonLSMGroup#sinsts | `Number:Power` | Instantaneous withdrawn apparent power |
+| commonLSMGroup#smaxsn | `Number:Power` | Maximum withdrawn apparent power of the day |
+| commonLSMGroup#smaxsnMinus1 | `Number:Power` | Maximum withdrawn apparent power of the previous day |
+| commonLSMGroup#ccasn | `Number:Power` | Active charge point N |
+| commonLSMGroup#ccasnMinus1 | `Number:Power` | Active charge point N-1 |
+| commonLSMGroup#umoy1 | `Number:Potential` | Mean Voltage on phase 1 |
+| commonLSMGroup#dpm*X* | `String` | Start of mobile peak period *X*, *X* in {1,2,3} |
+| commonLSMGroup#fpm*X* | `String` | End of mobile peak period *X*, *X* in {1,2,3} |
+| commonLSMGroup#msg1 | `String` | Short message |
+| commonLSMGroup#msg2 | `String` | Very short message |
+| commonLSMGroup#ntarf | `String` | Index of current pricing |
+| commonLSMGroup#njourf | `String` | Number of current provider schedule |
+| commonLSMGroup#njourfPlus1 | `String` | Number of next day provider schedule |
+| commonLSMGroup#pjourfPlus1 | `String` | Profile of next day provider schedule |
+| commonLSMGroup#ppointe | `String` | Profile of next rush day |
+| commonLSMGroup#date | `DateTime` | Date and Time |
+| commonLSMGroup#smaxsnDate | `DateTime` | Timestamp of SMAXSN value |
+| commonLSMGroup#smaxsnMinus1Date | `DateTime` | Timestamp of SMAXSN-1 value |
+| commonLSMGroup#ccasnDate | `DateTime` | Timestamp of CCASN value |
+| commonLSMGroup#ccasnMinus1Date | `DateTime` | Timestamp of CCASN-1 value |
+| commonLSMGroup#umoy1Date | `DateTime` | Timestamp of UMOY1 value |
+| commonLSMGroup#dpm*X*Date | `DateTime` | Date of DPM*X*, *X* in {1,2,3} |
+| commonLSMGroup#fpm*X*Date | `DateTime` | Date of FPM*X*, *X* in {1,2,3} |
+| commonLSMGroup#relais*X* | `Switch` | state of relais *X*, *X* in {1,...,8} |
+
+#### Three phase only channels
+
+These channels are available on the following telemeters:
+* lstm_electricitymeter
+* lsmt_prod_electricitymeter
+
+| Channel | Type | Description |
+|-----------------------------------------|---------------------------|-----------------------------------------------------------------------------------|
+| threePhasedLSMGroup#irms*X* | `Number:ElectricCurrent` | RMS Current on phase *X*, *X* in {2,3} |
+| threePhasedLSMGroup#urms*X* | `Number:Potential` | RMS Voltage on phase *X*, *X* in {2,3} |
+| threePhasedLSMGroup#umoy*X* | `Number:Potential` | Mean Voltage on phase *X*, *X* in {2,3} |
+| threePhasedLSMGroup#sinsts*X* | `Number:Power` | Instantaneous withdrawn apparent power on phase *X*, *X* in {1,2,3} |
+| threePhasedLSMGroup#smaxsn*X* | `Number:Power` | Maximum withdrawn apparent power of the day on phase *X*, *X* in {1,2,3} |
+| commonLSMGroup#umoy*X*Date | `DateTime` | Timestamp of UMOY*X* value, *X* in {2,3} |
+| threePhasedLSMGroup#smaxsn*X*Minus1 | `Number:Power` | Maximum withdrawn apparent power on the previous day on phase *X*, *X* in {1,2,3} |
+| threePhasedLSMGroup#smaxs*X*nDate | `DateTime` | Timestamp of SMAXSN*X* value, *X* in {1,2,3} |
+| threePhasedLSMGroup#smaxsn*X*Minus1Date | `DateTime` | Timestamp of SMAXSN*X*-1 value, *X* in {1,2,3} |
+
+#### Producer only channels
+
+These channels are available on the following telemeters:
+* lsmm_prod_electricitymeter
+* lsmt_prod_electricitymeter
+
+| Channel | Type | Description |
+|-----------------------------------|-----------------|----------------------------------------------------------|
+| producerLSMGroup#eait | `Number:Energy` | Total active energy injected |
+| producerLSMGroup#erq*X* | `Number:Energy` | Total reactive energy on index *X*, *X* in {1,...,4} |
+| producerLSMGroup#sinsti | `Number:Energy` | Instantaneous injected apparent power |
+| producerLSMGroup#smaxin | `Number:Power` | Maximum injected apparent power of the day |
+| producerLSMGroup#smaxinMinus1 | `Number:Power` | Maximum injected apparent power of the previous day |
+| producerLSMGroup#ccain | `Number:Power` | Injected active charge point N |
+| producerLSMGroup#ccainMinus1 | `Number:Power` | Injected active charge point N-1 |
+| producerLSMGroup#smaxinDate | `DateTime` | Timestamp of SMAXIN value |
+| producerLSMGroup#smaxinMinus1Date | `DateTime` | Timestamp of SMAXIN-1 value |
+| producerLSMGroup#ccainDate | `DateTime` | Timestamp of CCAIN value |
+| producerLSMGroup#ccainMinus1Date | `DateTime` | Timestamp of CCAIN-1 value |
## Full Example
@@ -190,14 +216,40 @@ Number:Energy TLInfoEDF_HCHP "HCHP" {channel="teleinfo:cbemm_evolution_
String TLInfoEDF_HHPHC "HHPHC" {channel="teleinfo:cbemm_evolution_icc_hc_electricitymeter:teleinfoUSB:myElectricityMeter:hhphc"}
```
+### Standard TIC mode
+
+The following `things` file declare a serial USB controller on `/dev/ttyUSB0` for a Linky Single-phase Electricity meter in standard TIC mode and adsc `031528042289` :
+
+```
+Bridge teleinfo:serialcontroller:teleinfoUSB [ serialport="/dev/ttyUSB0", ticMode="STANDARD" ]{
+ Thing lsmm_electricitymeter myElectricityMeter [ adco="031528042289"]
+}
+```
+
+This `items` file links some supported channels to items:
+
+```
+Number:Power TLInfoEDF_SINSTS "SINSTS" ["Measurement","Power"] {channel="teleinfo:lsmm_electricitymeter:teleinfoUSB:myElectricityMeter:commonLSMGroup#sinsts"}
+Number:ElectricCurrent TLInfoEDF_PREF "PREF" ["Measurement","Power"] {channel="teleinfo:lsmm_electricitymeter:teleinfoUSB:myElectricityMeter:commonLSMGroup#pref"}
+String TLInfoEDF_LTARF "LTARF" ["Status"] {channel="teleinfo:lsmm_electricitymeter:teleinfoUSB:myElectricityMeter:commonLSMGroup#ltarf"}
+Number:ElectricCurrent TLInfoEDF_SMAXSN "SMAXSN" ["Measurement","Energy"] {channel="teleinfo:lsmm_electricitymeter:teleinfoUSB:myElectricityMeter:commonLSMGroup#smaxsn"}
+Number:ElectricCurrent TLInfoEDF_IRMS1 "IRMS1" ["Measurement","Current"] {channel="teleinfo:lsmm_electricitymeter:teleinfoUSB:myElectricityMeter:commonLSMGroup#irms1"}
+Number:Energy TLInfoEDF_EASF01 "EASF01" ["Measurement","Energy"] {channel="teleinfo:lsmm_electricitymeter:teleinfoUSB:myElectricityMeter:commonLSMGroup#easf01"}
+Number:Energy TLInfoEDF_EASF02 "EASF02" ["Measurement","Energy"] {channel="teleinfo:lsmm_electricitymeter:teleinfoUSB:myElectricityMeter:commonLSMGroup#easf02"}
+String TLInfoEDF_NGTF "NGTF" ["Status"] {channel="teleinfo:lsmm_electricitymeter:teleinfoUSB:myElectricityMeter:commonLSMGroup#ngtf"}
+DateTime TLInfoEDF_SMAXSN_DATE "SMAXSN_DATE" ["Measurement","Energy"] {channel="teleinfo:lsmm_electricitymeter:teleinfoUSB:myElectricityMeter:commonLSMGroup#smaxsnDate"}
+```
+
## Tested hardware
The Teleinfo binding has been successfully validated with below hardware configuration:
-| Serial interface | Power Energy Meter model | Mode(s) |
-|----------|--------|------------------------------|
-| GCE Electronics USB Teleinfo module [(more details)](https://gce-electronics.com/fr/usb/655-module-teleinfo-usb.html) | Actaris A14C5 | Single-phase HCHP & Base |
-| Cartelectronic USB Teleinfo modem [(more details)](https://www.cartelectronic.fr/teleinfo-compteur-enedis/17-teleinfo-1-compteur-usb-rail-din-3760313520028.html) | Sagem S10C4 | Single-phase HCHP |
+| Serial interface | Power Energy Meter model | Mode(s) | TIC mode |
+|------------------|-----------------------------|---------------------------|----------|
+| GCE Electronics USB Teleinfo module [(more details)](https://gce-electronics.com/fr/usb/655-module-teleinfo-usb.html) | Actaris A14C5 | Single-phase HCHP & Base | Historical |
+| Cartelectronic USB Teleinfo modem [(more details)](https://www.cartelectronic.fr/teleinfo-compteur-enedis/17-teleinfo-1-compteur-usb-rail-din-3760313520028.html) | Sagem S10C4 | Single-phase HCHP | Historical |
+| GCE Electronics USB Teleinfo module [(more details)](https://gce-electronics.com/fr/usb/655-module-teleinfo-usb.html) | Linky | Single-phase HCHP | Standard |
+| Cartelectronic USB Teleinfo modem [(more details)](https://www.cartelectronic.fr/teleinfo-compteur-enedis/17-teleinfo-1-compteur-usb-rail-din-3760313520028.html) | Linky | Three-phase TEMPO | Standard |
On Linky telemeters, only *historical* TIC mode is currently supported.
The method for changing the TIC mode of a Linky telemeter is explained [here](https://forum.gce-electronics.com/t/comment-passer-un-cpt-linky-en-mode-standard/8206/7).