Notifications
You must be signed in to change notification settings - Fork 15
/
RFLink Protocol Reference.txt
132 lines (120 loc) · 6.16 KB
/
RFLink Protocol Reference.txt
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
Nodo - RFLink Commands and Data fields
The use of this protocol is free for both server and client sides of the implementation
Data is send serial (via USB) as "text" at a speed of 57600 baud (N,8,1)
It is sufficient to open a port and listen to the data.
Each text line contains information that has been received via RF signals.
Packet structure - Received data from RF:
-----------------------------------------
20;ID=9999;Name;LABEL=data;
20 => Node number 20 means from RFLink to the master, 10 means from the master to RFLink
; => field separator
NAME => Device name (can be used to display in applications etc.)
LABEL=data => contains the field type and data for that field, can be present multiple times per device
Packet structure - Send data via RF:
------------------------------------
10;Name;device;action;
10;Kaku;A1;ON; => protocol;address;action (ON/OFF)
10;NewKaku;00c142;1;ON; => protocol;address;button number (hexadecimal 0x0-0x0f);action (ON/OFF/ALLON/ALLOFF/15 - 1 to 15 for direct dim level)
10;HomeEasy;7900b100;3;ON; => protocol;address;action (ON/OFF/ALLON/ALLOFF)
10;SmokeAlert;123456;ON; => protocol;address;action
10;FA500;12345678;ON; => protocol;address;action (ON/OFF)
10;Eurodomest;123456;01;ON; => protocol;address;button number;action (ON/OFF/ALLON/ALLOFF)
10;Selectplus;1234; => protocol;address
10;Byron;1234;01 => protocol;address;ringtone;
10;Blyss;ff98;A1;OFF; => protocol;address;button;action (ON/OFF/ALLON/ALLOFF)
Control Commands - Send:
--------------------------
10;REBOOT; => Reboot RFLink hardware
10;PING; => Is replied with: 20;99;PONG;
10;VERSION; => Is replied with: 20;99;"RFLink software version";
10;RFDEBUG=ON; => ON/OFF to Enable/Disable showing of RF packets. Is replied with: 20;99;RFDEBUG="state";
10;RFUDEBUG=ON; => ON/OFF to Enable/Disable showing of undecoded RF packets. Is replied with: 20;99;RFUDEBUG="state";
10;QRFDEBUG=ON; => ON/OFF to Enable/Disable showing of undecoded RF packets. Is replied with: 20;99;QRFDEBUG="state";
QRFDEBUG is a faster version of RFUDEBUG but all pulse times are shown in hexadecimal and need to be multiplied by 25
Data Fields: (LABEL=data)
------------
ID=9999 => device ID (often a rolling code and/or device channel number)
SWITCH=A16 => House/Unit code like A1, P2, B16 or a button number etc.
CMD=ON => Command (ON/OFF/ALLON/ALLOFF)
TEMP=9999 => Temperature (hexadecimal), high bit contains negative sign, needs devision by 10
HUM=99 => Humidity (hexadecimal)
BARO=9999 => Barometric pressure (hexadecimal)
HSTATUS=99 => 0=Normal, 1=Comfortable, 2=Dry, 3=Wet
BFORECAST=99 => 0=No Info/Unknown, 1=Sunny, 2=Partly Cloudy, 3=Cloudy, 4=Rain
UV=9999 => UV intensity (hexadecimal)
LUX=9999 => Light intensity (hexadecimal)
BAT=OK => Battery status indicator (OK/LOW)
RAIN=1234 => rain rate in mm. (hexadecimal)
RAINTOT=1234 => total rain in mm. (hexadecimal)
WINSP=9999 => Wind speed in km. p/h (hexadecimal) needs devision by 10
AWINSP=9999 => Average Wind speed in km. p/h (hexadecimal) needs devision by 10
WINGS=9999 => Wind Gust in km. p/h (hexadecimal)
WINDIR=123 => Wind direction 0-15 reflecting 0-360 degrees in 22.5 degree steps (decimal)
WINCHL => wind chill (hexadecimal)
WINTMP=1234 => Wind meter temperature reading (hexadecimal)
CHIME=123 => Chime/Doorbell melody number
SMOKEALERT=ON => ON/OFF
PIR=ON => ON/OFF
CO2=1234 => CO2 air quality
SOUND=1234 => Noise level
KWATT=1234 => KWatt
WATT=1234 => Watt
DIST=1234 => Distance
METER=1234 => Water flow meter
VOLT=1234 => Voltage
CURRENT=1234 => Current
Sample data:
------------
20;2D;UPM/Esic;ID=0001;TEMP=00cf;HUM=16;BAT=OK;
20;6A;UPM/Esic;ID=1002;WINSP=0041;WINDIR=5A;BAT=OK;
20;08;UPM/Esic;ID=1003;RAIN=0010;BAT=OK;
20;31;Mebus;ID=c201;TEMP=00cf;
20;32;Auriol;ID=008f;TEMP=00d3;BAT=OK;
20;A2;Auriol V2;ID=008f;TEMP=00a3;BAT=LOW;
20;33;Cresta;ID=3001;TEMP=00b0;HUM=50;
20;0C;Cresta;ID=8001;RAIN=001c;
20;47;Cresta;ID=8001;WINDIR=0002;WINSP=0060;WINGS=0088;WINCHL=b0;
20;47;Cresta;ID=8001;TEMP=00b0;UV=00d0;
20;36;Alecto V1;ID=ec02;TEMP=00d1;HUM=14;
20;07;Mebus;ID=ea01;TEMP=0017;
20;3D;Alecto V1;ID=2000;TEMP=0011;HUM=61;
20;26;Alecto V1;ID=0086;RAIN=02ac;
20;30;Alecto V1;ID=0020;WINSP=0068;
20;16;Alecto V1;ID=0020;WINSP=0020;
20;17;Alecto V1;ID=0020;WINDIR=0002;WINGS=0088;
20;36;Alecto V1;ID=0020;WINDIR=0002;WINGS=0040;
20;74;Oregon TempHygro;ID=0ACC;TEMP=00be;HUM=40;BAT=OK;
20;b3;Oregon TempHygro;ID=1a2d;TEMP=00dd;HUM=43;BAT=OK;
20;e5;Oregon BTHR;ID=5a6d;TEMP=00be;HUM=40;BARO=03d7;BAT=OK;
20;46;Oregon Rain;ID=2a1d;RAIN=0012;RAINTOT=0012;BAT=OK;
20;83;Oregon Rain2;ID=2a19;RAIN=002a;RAINTOT=0054;BAT=OK;
20;32;Oregon Wind;ID=1a89;WDIR=0045;WINSP=0068;AWINSP=0050;BAT=OK;
20;4a;Oregon Wind2;ID=3a0d;WDIR=0021;WINSP=0040;AWINSP=005a;BAT=OK;
20;ba;Oregon UVN128/138;ID=ea7c;UV=0030;BAT=OK;
20;AF;SelectPlus;ID=1bb4;CHIME=01;
20;FC;Plieger York;ID=dd01;CHIME=02;
20;47;Byron SX;ID=a66a;CHIME=A9;
20;12;Pir;ID=aa66;PIR=ON;
20;63;SmokeAlert;ID=123456;SMOKEALERT=ON;
20;06;Kaku;ID=41;SWITCH=1;CMD=ON;
20;0C;Kaku;ID=41;SWITCH=2;CMD=OFF;
20;0D;Kaku;ID=41;SWITCH=2;CMD=ON;
20;46;Kaku;ID=44;SWITCH=4;CMD=OFF;
20;E0;NewKaku;ID=cac142;SWITCH=1;CMD=ALLOFF;
20;3B;NewKaku;ID=cac142;SWITCH=3;CMD=OFF;
20;0B;NewKaku;ID=000005;SWITCH=2;CMD=ON;
20;0E;NewKaku;ID=000005;SWITCH=2;CMD=OFF;
20;12;NewKaku;ID=000002;SWITCH=2;CMD=OFF;
20;1E;NewKaku;ID=00000a;SWITCH=2;CMD=OFF;
20;1F;NewKaku;ID=00000a;SWITCH=2;CMD=ON;
20;01;NewKaku;ID=000007;SWITCH=2;CMD=OFF;
20;04;NewKaku;ID=000007;SWITCH=2;CMD=ON;
20;04;NewKaku;ID=000007;SWITCH=2;CMD=SET_LEVEL=14;
20;0C;HomeEasy;ID=7900b200;SWITCH=0b;CMD=ALLON;
20;AD;FA500;ID=0d00b900;SWITCH=0001;CMD=UNKOWN;
20;AE;FA500;ID=0a01;SWITCH=0a01;CMD=OFF;
20;03;Eurodomest;ID=03696b;SWITCH=00;CMD=OFF;
20;04;Eurodomest;ID=03696b;SWITCH=07;CMD=ALLOFF;
20;41;Conrad RSL2;ID=010002;SWITCH=03;CMD=ON;
20;47;Blyss;ID=ff98;SWITCH=A1;CMD=ON;
20;73;Kambrook;ID=010203;SWITCH=A1;CMD=OFF;