question Calibration.estimate_bg_at_time_of_calibration never assigned a value #361

Open
JohanDegraeve opened this issue Jul 8, 2016 · 3 comments

Comments

@JohanDegraeve
Copy link
Contributor

question, in Calibration.java there's an attribute named estimate_bg_at_time_of_calibration
If I "find Usages" for that attribute, it seems to be read only but never written ?

@AdrianLxM
Copy link
Collaborator

Yea, this is the reason why the SlopeOOB-Handler never (or rarely) returns the slope from before but always defaults to the default values. :(

@petersayeghpeter
Copy link

#359

@AdrianLxM
Copy link
Collaborator

@petersayeghpeter, I don't see Calibration.java changed in the PR you linked?