Skip to content

Modification History

SBF edited this page Feb 22, 2025 · 45 revisions

3.9.12 (22-FEB-2025) (bugfix release)

Fixes and improvements:

  • Added "include" keyword to config (See #720)
  • Fix SBFspot not completely quiet when using -q (See #721)
  • Tightened some debug messages
  • Fix #722 Data for Sunny Tripower 8.0 SE is not exported to 123Solar
  • Fix #723 Cannot build with Boost V1.87 (remove deprecated method from_string())

3.9.11 (18-JUN-2024) (bugfix release)

Fixes and improvements:

  • Fix #700 Partial ArchiveDayData after PacketID mismatch
  • Fix #695 Error compiling on recent Armbian / arm debian with mariadb reference to deprecated include <mysql/mysql.h>
  • Prepare for SMAdata2+ protocol decoder plugin

3.9.10 (14-JUN-2024) (bugfix release)

Fixes and improvements:

  • Fix regression (Month data shifted by one day on some systems)
  • #694 Corrupt data
  • Removed redundant events sorting
  • #701 Double data in Monthdata table

3.9.9 (25-FEB-2024) (bugfix release)

Regression test failed. Release retired.

Fixes and improvements:

  • #442 Failed to get current plant time
  • #532 SBFspotUpload service stops when remote SQL server is temporarily down
  • Added SqlQueryInterval to Upload service/daemon config option
  • Fix Y2038 issue (See #688 Not able to set inverter time)
  • #692 Compile failure on Debian 12 - 64 bit

3.9.8 (23-JAN-2024) (bugfix release)

Fixes and improvements:

  • MQTT stream to Custom CSV
  • Fail on incompatible firmware version when MIS_ENABLED=0 (See #37 #535 #678)
  • #578 Corrupted/Future data from Inverter
  • #635 The mystery of the sole 2.5 min interval datapoint... and it's corrupt
  • #637 addBatchStatus() returned Unsupported protocol in Windows install

3.9.7 (01-APR-2023) (bugfix release)

Fixes and improvements:

  • #567 Segmentation fault when connection address is missing
  • #599 Added https support for PVOutput uploads
  • #630 Battery related values all zero (Hybrid Inverter)
  • -version command line argument added
  • Taglists updated

3.9.6 (27-AUG-2022) (bugfix release)

Fixes and improvements:

  • #549 After upgrade to v395, the CSV file is no longer written
  • #559 SBFspotUploadDaemon log to stdout?

3.9.5 (05-JUN-2022) (bugfix release)

Fixes and improvements:

  • Fix Events not written to database introduced in V3.9.0 (MySQL/MariaDB only)
  • #527 Data too long for column 'OldValue'
  • #539 Garbage in battery CSV file
  • Improved event decoding
  • Add SBFspotVersion and Plantname to mqtt stream

3.9.4 (25-MAR-2022) (bugfix release)

Fixes:

  • Fail on incompatible firmware version (see iobroker.net)
  • Improved SPW device discovery
  • Handle returncode 21 (E_LRINOTAVAIL)
  • Handle returncode -1 (Implement retry comm)

3.9.3 (25-FEB-2022) (bugfix release)

Fixes:

  • Return real error code when logon failed (deprecated E_LOGONFAILED)
  • #519: SMA2500TLST values wrong in CSV
  • #520: Output format modified - earlier format had standard format with 2 MPPT's
  • #522: Redundant loop

3.9.2 (12-JAN-2022) (bugfix release)

Fixes:

  • #511: Segmentation fault on V3.9.1

3.9.1 (03-JAN-2022) (bugfix release)

Fixes:

  • #508: No contents written into the csv file: 'spot'

3.9.0 (28-DEC-2021) (minor release)

Fixes:

  • Fixed #3: Three string SMA inverters
  • Fixed #401: Multiple strings support
  • Fixed #421: SMA core2 has 12 strings
  • Fixed #496: WakeUp/Sleep time in MQTT
  • Fixed #419: SMA Energymeter & SMA Inverter: report current MeteringGridMsTotW*
  • Merged #420/#440: (manually merged) Add inverter power measurements from a connected energy meter

Other changes:

  • Removed Web Solar Log (WSL) support

3.8.4 (11-DEC-2021) (bugfix release)

Fixes:

Various issues fixed related to "Bad request 400: Power value too high for system size" Fix 384/137/381/313/... Bad request 400: Power value too high for system size

  • Fixed #137: workaround for: Power value too high for system size
  • Fixed #313: Bad request 400: Power value [15538XXXX] too high for system size [1212]
  • Fixed #381: Continual Error Loops - "Power value [XXXXXXXX] too high for system size [3640]
  • Fixed #384: No data received at pvoutput

Enhancements and other changes:

  • Improved event decoding
  • Dump events to console
  • Cleanup verbose/debug messages

3.8.3 (12-SEP-2021) (bugfix release)

Fixes:

  • Fixed #476: V3.8.2 fails to compile on Fedora 34
  • Fixed #467: Let executable return errors in Inverter::process()
  • Fixed #482: Some data missing on 2nd Inverter

3.8.2 (22-MAY-2021) (bugfix release)

Fixes:

  • Fixed #455: Voltages and Currents in .csv file swapped for battery inverter
  • Fixed #428: SBFspotUploadDaemon crash
  • Fixed #459: Incorrect Calculated EToday
  • Fixed #330: From Sqlite3 to MySQL
  • Fixed #457: Serial number too big for defined field

3.8.1 (18-APR-2021) (bugfix release)

Fixes:

  • Fixed #448: Error:sqlite3_exec() returned: "UNIQUE constraint failed"
  • Fixed #378: MQTT: Missing Parameter BT-Signal - PdcTot
  • Merged #450: MQTT: let sunrise/sunset timestamps obey configured format

Enhancements:

  • Added #402: How to specify bluetooth device on Raspbian?

3.8.0 (18-MAR-2021) (minor release)

Fixes:

  • Fixed #403: issue compiling with nosql (undefined reference)
  • Fixed memory leaks (see #318)
  • Fixed #7 MariaDB10 with Port 3307
  • Fixed SQL daydata export (for PVoutput) : Include zero record, just after production stopped
  • Fixed #395 Mix of ISO-8859-1 and UTF-8, CRLF and LF line endings
  • Merged #425 Move Inverter related stuff to dedicated class
  • Fixed #290 Etoday and temperature are shown as ZERO from STP6.0 inverter

3.7.1 (11-JAN-2021) (bugfix release)

Fixes:

  • Fixed makefile - make should copy ALL .sql files
  • Fixed undefined reference to 'boost::system::system_category()' introduced with PR #361
  • Fixed #403: issue compiling with nosql (undefined reference)
  • Fixed #409: Invalid timezone specified (updated date_time_zonespec.csv)
  • Fixed #412: skipping unresponsive inverter
  • Fixed #417: MQTT publishing issue
  • Merged #413: Add CMake support

3.7.0 (20-JUN-2020) (minor release)

Fixes:

  • Fixed #334: MQTT JSON Publish - different attribute notation on multiple instances
  • Fixed #337: Unknown Inverter Type SB7.7-1SP-US-41
  • Fixed #350: Limitation for MQTT keywords?
  • Fixed #352: Unknown Inverter Type SBS6.0-US-10
  • Merged #361: Openwrt
  • Merged #371: Some bugfixes with a SMA Home Manager 2.0 in the network
  • Merged #374: Fixed bug where efficiency was always 0 in ExportSpotDataToCSV
  • Fixed #390: sbfspot and mysql/mariadb
  • Fixed #391: Unknown Inverter: SMA Sunny Island 4.4M-13

Enhancements:

  • Added #367: Added support for SB 240 & Multigate-10 by merging 3.2.1 (Thanks to Rob Meerwijk)
  • Added Edimax Smart Plugs and some newer inverters
  • Renamed Optical Global Peak to SMA ShadeFix

3.6.0 (08-OCT-2019) (minor release)

Fixes:

  • Fixed : Error! Could not open file C?\C:\PathToConfig\SBFspot.cfg (Windows only - reported by mail)
  • Fixed #327: Unknown inverter: Sunny Boy Storage 5.0 (SBS5.0-10) & Sunny Tripower 10.0 (STP10.0-3AV-40)
  • Fixed #328: Unknown inverter type Sunny Boy Storage 6.0

Enhancements:


3.5.3 (07-JUL-2019) (unreleased bugfix)

Fixes:

  • Fixed #302: Unknown Inverter Type - SMA Sunny Tripower 3.0
  • Fixed #309: Unknown Inverter Type - SMA Sunny Tripower 8.0
  • Fix warnings [-Wformat-truncation=] Raspbian Buster (gcc 8.3)

3.5.2 (19-JUN-2019) (bugfix release)

Fixes:

  • Fixed #297: 0x000024BA and Inverter Type=SB3.6-1AV-41

3.5.1 (14-MAR-2019) (bugfix release)

Fixes:

  • Fixed #230: Unknown Inverter Type SBS3.7-10
  • Fixed #261: Unknown Inverter Type STP4.0-3AV-40
  • Fixed #269: SMA STP6.0-3AV-40 no readout with SBFspot?
  • Fixed #279: Unknown inverter type SMA STP6.0-3AV-40
  • Fixed #281: SBFspotUploadDaemon not uploading
  • Fixed #287: Unknown inverter type SMA STP5.0-3AV-40 (Added 12-APR-2019)

3.5.0 (22-JUL-2018) (minor release)

Fixes:

  • Fixed #215: Start SBFspotUpload.service failed because the control process exited with error code
  • Fixed #224: SBFSpotUpload.cfg - log level doesn't work
  • Fixed #230: Unknown Inverter Type SBS3.7-10

Improvements:

SBFspotUploadDaemon v2.0.0 - Redesigned for systemd (Thanks to Jonathan de Boyne Pollard)


3.4.1 (12-JUN-2018) (bugfix release)

Fixes:

  • Issue #207: How to collect battery statistics with v3.4.0
  • Issue #218: .out file not deleted when daemon stops
  • Fixed some warnings for VS2015

3.4.0 (25-FEB-2018) (bugfix release)

Fixes:

  • Issue #43 (CP37) : Line endings in UNIX are not CR/LF
  • Issue #58 (CP54) : SQL Support for battery inverters
  • Issue #98 (CP93) : Add PID-File for SBFspotUploadDaemon
  • Issue #158 (CP154): Reference to 'uint64_t' is ambiguous
  • Issue #171 (CP167): SMA SB6.0-US Communication Hanging (See also unreleased V3.3.3)
  • Issue #173 (CP169): fixed path "date_time_zonespec.csv"
  • Issue #174 (CP170): Not completely silent with -q
  • Issue #177 (CP173): MySQL EToday and ETotal as integer
  • Issue #183 (CP179): Not identifying new SMA SB 3.6-1 40-AV
  • Issue #184 (CP180): Unknown Inverter Type
  • Issue #185 (CP181): Tool goes to broadcast and search inverter when 10.1.1.1-9 IPs used
  • Issue #186 (CP182): New Sunny Boy inverters are unknown

Other fixes & improvements

  • Fix SayHello banner printed twice when using -?
  • Fix uncatched logon failure (Speedwire only)
  • Support for Smart Energy Inverters (Solar Inverters with battery)
  • "Invalid chk" (Bluetooth) (See also unreleased V3.3.5)

3.3.5 (10-OCT-2017) (unreleased bugfix)

Fixes:

  • "Invalid chk" (Bluetooth)

3.3.3 (09-JAN-2017) (unreleased bugfix)

Fixes:

  • Issue C167: SMA SB6.0-US Communication Hanging

3.3.2 (20-SEP-2016) (patch)

Fixes:

  • Issue C160: Doesn't compile with gcc 6.1.1 (Fedora 24)

3.3.1 (31-MAY-2016) (bugfix release - stable)

This release does not contain the functionalities of V3.2.0

Enhancements:

  • Changed functionality of SynchTime config parameter (can be a value of 0-30 instead of 0-1)
    • SynchTime=0 -> Time adjustment disabled
    • SynchTime=1 -> Time is adjusted once a day (if needed)
    • SynchTime=7 -> Time is adjusted once a week
    • SynchTime=30 -> Time is adjusted once a month

Fixes:

  • Issue C150: SBFspotUploadDaemon not uploading after upgrade to Ubuntu 16.04

3.3.0 (05-APR-2016) (minor release - beta)

Enhancements:

  • Added functionality to set plant time (Only for Bluetooth devices)
    • When enabled, keep plant time in sync with host time automatically (SynchTimeLow and SynchTimeHigh config options added)
    • Set plant time once per day/week with -settime command line argument

3.2.0 (beta)

Enhancements:

  • Added support for SB 240 & Multigate-10
  • Added XML export -xml

3.1.5 (05-APR-2016) (bugfix release)

Fixes:

  • Issue C126: Sync time issue
  • Issue C138: Segfault when SMA is not ready after sun up (was not fixed in 3.1.4)

3.1.4 (02-MAR-2016) (bugfix release)

Fixes:

  • Issue C115: Monthdata shifted 1 day
  • Issue C130: One inverter one day off in MIS mode
  • Issue C138: Segfault when SMA is not ready after sun up
  • Issue reported by e-mail: Energy Meter timeout fix

3.1.3 (26-SEP-2015) (Unreleased bugfix)

3.1.2 (22-SEP-2015) (bugfix release)

Changes:

  • Removed Active Power Control (-apl)

Fixes:

  • Issue C129: SBFspotUploadDaemon 3.1.1 gives error message
  • Issue C131: Donation status changes 'lost' in v3.1.1
  • Issue C133: 123Solar: There is no data to export!

3.1.1 (08-SEP-2015) (bugfix release)

❗ Read this thread about V3.1.1 retirement.

Enhancements:

  • Improved -apl command line switch (Set Active Power Limit)

Fixes:

  • Issue C113: Communication issues with Sunny Boy 1.5
  • Issue C127: SBFspot-3.1.0 doesn't build on CentOS_6

3.1.0 (29-JUL-2015) (beta)

Enhancements:

  • Multi Inverter Support for Speedwire devices (Add a comma separated list of IP adresses to your SBFspot.cfg)
  • More devices recognized (eg SB1.5-1VL-40)
  • Added Active Power Control (reduces the AC power of your inverter)
    • New -apl command line switch (Set Active Power Limit)
    • New -sn command line switch (Serial Number)
  • Better handling of "exec_query: database is locked" messages (Issue C114)

Fixes:

  • Issue C110: Arch Linux: SBFspot does not compile with BOOST 1.58
  • Issue C115: Monthdata shifted 1 day
  • Issue C118: Compile error in boost_ext.cpp

3.0.8 (24-MAY-2015) Bugfix Release (beta)

Fixes:

  • Issue C108: SBFspot v307 crashes for daily export
  • Issue C109: Bad request 400: Power value too high for system size

Enhancements:

  • Added -startdate CLI option

3.0.7 (19-APR-2015) Bugfix Release (beta)

Fixes:

  • Issue C90: SBFspot still creating 1970 .csv files
  • Issue C96: SBFspot generates '1970'-daily file
  • Issue C103: Eleminate confusion: apply name: session-id iso SN
  • Issue C105: Error in calculating Power Output - Too High
  • Issue C106: Compilation error of v307

3.0.6 (23-FEB-2015) Bugfix Release (unreleased beta)

Enhancements:

Although not tested by me, I've been told this SBFspot version compiles and runs successfully on MIPS router with OpenWRT

Fixes:

  • Issue C98: Inverter Serial wrong on big endian architecture

3.0.5 (30-DEC-2014) Bugfix Release (beta)

Fixes:

  • Issue C58: Crash when modif of user-defined params
  • Issue C79: Sigsegv using mysql export
  • ~~ Issue C89: Error during reading data from convertor~~

3.0.4 (21-DEC-2014) Bugfix Release (beta)

BT devices only

Fixes:

  • Issue C76: SBFspot in loop

3.0.3 (15-DEC-2014) Bugfix Release

Fixes:

  • Issue C77: SBFspotUploadDaemon 3.02 won't compile on raspberry
  • Issue C78: No SQL transactions with MySQL
  • Issue C84: Mismatch between extracted config in stdout and SBFspot.cfg
  • Issue C87: Unknown Inverter Type for SB7000TL-US-22
  • Issue C88: Version check problem MySQL

3.0.2 (09-NOV-2014) Bugfix Release

Fixes:

  • Issue C18: Efficiency value
  • Issue C60: PacTot is not populated
  • Issue C65: SBFspotUploadDaemon failed
  • Issue C72: 123solar and SMA - temperature
  • Issue C73: Endianness issue
  • Issue C74: Double data in Monthdata tables

3.0.1 (11-SEP-2014)

Enhancements:

  • -nosql command line parameter added to disable SQL export (Issue C51))
  • BTConnectRetries config parameter added to set max #connections for Bluetooth (Issue C28)
  • On 1st day of the month and -am1 specified, force to -am2 to get last day of previous month
  • ShowConfig() added (debugging aid)

Fixes:

  • Issue C54: Wrong data in month-output; Shifted 1 day
  • Issue C55: Upload error with SQLite

3.0.0 (29-AUG-2014) 2nd Anniversary Release

Enhancements:

  • SQL support
  • New Linux daemon or Windows service handles upload to PVoutput.org
  • Support for PVoutput configurable data fields V7-V12 (Issue C32)

Fixes:

  • Issue C40: Typo in Total DC Power
  • Issue C41: SB2000HF-30 - smaspot v > 2.06 - incorrect
  • Item: getSystemData() returned -1: Unknown error
  • Various items: Uninitialized inverterdata

2.4.5a (17-AUG-2014)

Fixes:

  • Issue C46: SBFspot not silent when running with -q (123Solar users only)

2.4.5 (28-MAY-2014)

In complex setups (including Webbox®, Sunny Home Manager®, SMA® radio-controlled sockets, etc...) it is now possible to connect directly to your inverter. To take advantage of this feature, you need to set MIS_Enabled=0 When you have multiple inverters, you will need a config for each inverter

Workaround for:

  • Issue C36: SBFspot >2.06a incompatible with SMA Webbox®
  • Issue C25: Fail to read 2nd Inverter
  • Issue C16: Problem with SMA homemanager®

2.4.4 (27-APR-2014)

Fixes:

  • Issue C30: Events incorrectly decoded (64-bit Linux only)

2.4.3 (Unreleased)

Fixes:

  • Fix for half hour timezones (eg Adelaide)

2.4.2 (31-MAR-2014)

Fixes:

  • Issue C17/C23: Day archive fails due to DST transition (Thanks Ruud_B for the fix provided)

2.4.1 (16-FEB-2014)

Fixes:

  • Issue C6: Install problem for v240 rc4203 - files to install
  • Issue C8: Config reference with Windows Version 2.4
  • Added DeviceClass Battery Inverter (8007) to TagList
  • Fixed date range for events CSV

Changes:

  • MIS disabled by default
  • Updated cfg file with new parameters
  • Added CSV export for battery inverters (Sunny Island)

2.4.0 (02-FEB-2014) (beta)

Contains code of 2.2.11 and 2.3.0 (unreleased) New dependency: boost You need to install libboost-all-dev

Fixes:

  • Issue G49: Extension demand for option read "archive daily" files (-ad##)
  • Issue G60: Wrong power calculation
  • Issue G61: PVoutput non-cum. Edaytotal vs cum. ETotal
    • Added CumulativeEnergy flag to config file
  • Issue G84: Enhance compatibility of daily .csv file with that of Sunny Explorer
  • Issue G90: Request to enhance the -cfg parameter
  • Issue G104: Enhance user information for contradicting settings: example pvoutput=0 <-> -u
  • Fixed "Packet ID mismatch" in superlong packet streams

Enhancements:

  • Added Readout of Inverter's Temperature
    • Added InverterTemp flag to config file to control upload to PVoutput
    • Added InverterTempMapTo option to enable use of Donation Mode
  • Added readout of user/installer Events
    • New commandline argument: -ae
    • New commandline arguments: -installer -password:xxxx
    • New config parameter: OutputPathEvents
  • Added localization of events
    • New config parameter: Locale
  • Added Error handling Speedwire INIT
  • Added -loadlive command line parameter for easy live upload to PVOutput
  • Preparation for better timezone handling
    • Added Timezone option to config file. See "date_time_zonespec.csv" for valid timezones.

2.2.11 (18-DEC-2013) (beta)

  • Fixed IP address supported

2.2.10 (02-DEC-2013)

  • bugfix: Application crash while retrieving archived monthdata (Speedwire only)

2.2.8 (26-NOV-2013)

Enhancements:

  • Speedwire support
  • Sunny Island support (limited)

2.1.1 (21-OCT-2013) (Interim Release)

Enhancements:

Added more inverter types

  • Issues 91,92,93,94,95,96,98

2.1.0 (Final) (21-SEP-2013)

Fixes:

  • Init function: small fix
  • Bug in CSV Spot Export when WebboxHeader enabled.

2.0.7 (18-SEP-2013) (Interim Release)

First attempt to support Speedwire/Ethernet.


2.1.0-RC5 (16-SEP-2013)

Fixes:

  • Init function redesigned (added code to rebuild network)
  • Introduced MIS_Enabled(0|1) config parameter
  • Issue G86: Added STP 9000 TL-20

2.0.6a (12-AUG-2013) (Interim Release)

Added support for 123solar (by Aldesr)


2.1.0-RC4 (17-JUL-2013)

Fixes:

Init function redesigned


2.1.0-RC3 (13-JUL-2013)

Fixes:

PacketID mismatch problem with MIS finally(?) solved

Remarks

There is still an issue when your SMA® network has more than 1 master (Webbox® / Sunnybeam® / SunnyExplorer®...)


2.1.0-RC2 (09-JUL-2013)

Fixes:

  • Issue G32: Commands have TimeOut - (BT interaction still active)
  • Issue G74: Not all command line arguments shown
  • Issue G78: Show the SusyId and Serial nmbr in the StdOut file
  • PacketID mismatch problem with MIS

Changes & Enhancements

  • Added SMC6000TL

2.1.0-RC1 (27-JUN-2013)

Fixes:

  • Issue 57: Create Unique SUSyID/Serial for application
  • Issue 62: New Inverters
  • Issue 63: Added VoltLogging=NONE to config
  • Issue 71: Webbox/Standard header configurable

Changes & Enhancements

  • Multi Inverter Support (MIS)
  • Added SB1300TL-10
  • Added STP7000TL-20
  • Webbox compatibility spotdata.csv (new header)
  • Disable spot csv export (-sp0)
  • "New CFG parameter: CSV_Spot_WebboxHeader"
  • Config parameter SynchTime defaults to 'ON'
  • Code cleanup

2.0.6 (09-JUN-2013)

Fixes:

  • Issues 50,51: sunrise/sunset problem
  • Issue 54: CSV exporting - wrong "delimiter" - "/" instead of "."
  • Issues 55,56: BT_Close() never called

Changes & Enhancements

  • Added STP5000TL-20
  • Added STP8000TL-20
  • Webbox compatibility spotdata.csv (new header)
  • WebSolarLog support (-wsl)
  • Quiet mode (-q)
  • Disable csv export (-nocsv)
  • "New CFG parameter: CSV_Spot_TimeSource (Inverter|Computer)"

2.0.5 (09-APR-2013)

Fixes:

  • Issue 33: buffer overflow detected: ./SBFspot terminated when exporting to csv
  • Issue 38: Add current time when sending errors to stderr (Enhancement)
  • Issue 41: Logon failed. Check 'USER' Password
  • Better protocol handling for multiple inverter plants

Changes & Enhancements

  • Added Inverter Status (Condition) and GridRelay Status to Spotdata.cfg
  • Added VoltageLogging parameter to config file to log AC or DC to PVoutput

2.0.4 (19-MAR-2013)

Fixes:

  • Issues 27: Unknown Inverter Type in version 2.03
  • Issues 28: CSV Extended header delimiter is hard coded to "semicolon"
  • minor issue with Firmware version printout

2.0.3 (12-MAR-2013)

Special thanks to Gerd Schnuff

Fixes:

  • Issue 10: false inverter name
  • Issue 25: Exporting/Collecting data cuts off a bit too early
  • A lot of code changes to improve protocol handling

Changes & Enhancements

  • New config item: SunRSOffset -> Offset to start before sunrise and end after sunset (0-3600 - default 900 seconds)
  • Login as "installer" (special request)

2.0.2 (07-MAR-2013)

Fixes:

  • Issue 20: Version 2.0.1 has lost a grip of time
  • Issue 23: AC voltage not uploaded to PVoutput

Changes & Enhancements

  • Support for PVDiary OutputPath: %Y expanded to year (See config file for details) - PVDiary is an online monitoring tool for Belgium and The Netherlands only

2.0.1 (28-FEB-2013)

Changes & Enhancements

  • Added -finq command line argument (see help -?)

2.0.0 (22-FEB-2013)

Changes & Enhancements

Uploads Power/Energy/AC Voltage to PVoutput.org


1.5.6 (21-FEB-2013)

Fixes:

  • Issue 16: Arbitrary "Logon failed. Check 'USER' Password" errors

1.5.4 (14-FEB-2013) - Quick fix for V153

Fixes:

Issue Archived daydata stops at 03:05


1.5.3 (12-FEB-2013)

Changes & Enhancements

  • Code refactoring
  • Better protocol handling

1.4.4 (19-DEC-2012)

Fixes:

  • Issue 12: Synchtime works now - Users with inverters without RT clock like 1600TL should upgrade

Changes & Enhancements

  • -ad90 and -am60 request implemented (5000TL-20)
  • added different config parameters to tailor csv files for manual output to pvoutput

1.4.3 (09-DEC-2012)

Changes & Enhancements

  • Issue 12: This release implements issue 12 (feature request)
  • A new config setting has been created to enable/disable this feature: SynchTime

1.4.2 (01-DEC-2012)

Fixes:

  • Issue 9: Missing a day (monthdata export bug)

1.4.1 (07-NOV-2012)

Changes & Enhancements

  • New option in config file: DecimalPoint=comma|point

1.4.0 (30-OCT-2012)

Fixes:

  • Issue 2: ArchiveDataRec struct members - Last day is included in Arch Month data
  • Issue 4: Program crash when BT signal is low
  • Strange "Checksum 7E" bug fixed in Arch Day/Month data
  • More robust parameter checking

Changes & Enhancements

  • db# & -mb# command line arguments replaced by -ad# & -am# (see help -?)

1.3.7 (26-OCT-2012)

Fixes:

  • This version fixes some issues introduced in 1.3.6

Changes & Enhancements

2 extra commandline parameters are added:

  • -db# gets the Archive data of #Days Back (if omitted or 0=today's values, 1=yesterday and so on...
  • -mb# gets the Archive data of #Months Back (if omitted or 0=this month's values, 1=previous month and so on...

1.3.6 (24-OCT-2012)

Changes not tracked


1.3.4 (04-OCT-2012)

Changes not tracked


1.2.0 (13-SEP-2012)

Changes not tracked


1.1.0 (11-SEP-2012)

Changes not tracked


The very first version was released 29-AUG-2012


Registered Trademarks

SMA, Speedwire, Sunny Webbox, Sunny Home Manager, Sunny Beam, Sunny Boy, Windy Boy, Sunny Island, ShadeFix and Sunny Explorer are registered trademarks of SMA Solar Technology AG


Clone this wiki locally