You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Hi,
as the title says, pairing a cu0007 dongle flashed with the G700 firmware doesn't work with the April Brother. I didn't know where to put this issue, in the munifying repo or here, so if this is the wrong place please just inform me and I will create the issue in the other repo as well.
LOGITacker Version: 0.2.1
munifying Version: current git status
Log:
./munifying info
Found CU0007 Dongle for G700/G700s mouse
Using dongle USB config: Configuration 1
Resetting dongle in order to release it from kernel (connected devices won't be usable)
EP descr: ep #1 IN (address 0x81) interrupt - undefined usage [8 bytes]
EP descr: ep #2 IN (address 0x82) interrupt - undefined usage [20 bytes]
HID++ interface: vid=046d,pid=c531,bus=2,addr=5,config=1,if=1,alt=0
HID++ interface IN endpoint: ep #2 IN (address 0x82) interrupt - undefined usage [20 bytes]
Dongle Info
Closing Logitech receiver in Firmware mode (not bootloader)...
./munifying pair
Found CU0007 Dongle for G700/G700s mouse
Using dongle USB config: Configuration 1
Resetting dongle in order to release it from kernel (connected devices won't be usable)
EP descr: ep #1 IN (address 0x81) interrupt - undefined usage [8 bytes]
EP descr: ep #2 IN (address 0x82) interrupt - undefined usage [20 bytes]
HID++ interface: vid=046d,pid=c531,bus=2,addr=5,config=1,if=1,alt=0
HID++ interface IN endpoint: ep #2 IN (address 0x82) interrupt - undefined usage [20 bytes]
Enable pairing for 60 seconds
USB Report type: HID++ short message, DeviceID: 0xff, SubID: SET REGISTER SHORT, Params: 0xb2 0x00 0x00 0x00
Register address: REGISTER PAIRING
Value: 0x00 0x00 0x00
... Enable pairing response (should be enabled)
Printing follow up reports ...
LOGITacker (discover) $ pair device run
Trying to pair using Unifying global pairing address
LOGITACKER_RADIO: Channel hopping stopped
LOGITACKER_PROCESSOR_PAIR_DEVICE: Try to pair new device on target address BB:0A:DC:A5:75
LOGITACKER_RADIO: Channel hopping stopped
ESB_ILLEGALMOD: Using channel table 'Unifying pairing'
ESB_ILLEGALMOD: New channel table with length 11
LOGITACKER_PROCESSOR_PAIR_DEVICE: phase before TX: 0
LOGITACKER_PROCESSOR_PAIR_DEVICE: phase after TX: 1
LOGITACKER_PROCESSOR_PAIR_DEVICE: E1 5F 01 DE AD BE EF 82|._......
LOGITACKER_PROCESSOR_PAIR_DEVICE: 08 13 37 04 00 01 05 0 |......
LOGITACKER_PROCESSOR_PAIR_DEVICE: 00 00 00 00 00 A9 |......
LOGITACKER_PROCESSOR_PAIR_DEVICE: TX'ed to BB:0A:DC:A5:75
LOGITACKER_PROCESSOR_PAIR_DEVICE: Phase before RX: 1
LOGITACKER_PROCESSOR_PAIR_DEVICE: |
LOGITACKER_PROCESSOR_PAIR_DEVICE: RX phase after parsing: 2
LOGITACKER_PROCESSOR_PAIR_DEVICE: phase before TX: 2
LOGITACKER_PROCESSOR_PAIR_DEVICE: phase after TX: 3
LOGITACKER_PROCESSOR_PAIR_DEVICE: E1 40 01 DE 00 |.@...
LOGITACKER_PROCESSOR_PAIR_DEVICE: TX'ed to BB:0A:DC:A5:75
LOGITACKER_PROCESSOR_PAIR_DEVICE: Phase before RX: 3
LOGITACKER_PROCESSOR_PAIR_DEVICE: |
LOGITACKER_PROCESSOR_PAIR_DEVICE: phase before TX: 3
LOGITACKER_PROCESSOR_PAIR_DEVICE: update TX payload called for unknown pairing phase: 3
LOGITACKER_PROCESSOR_PAIR_DEVICE: phase after TX: 3
LOGITACKER_PROCESSOR_PAIR_DEVICE: E1 40 01 DE 00 |.@...
LOGITACKER_PROCESSOR_PAIR_DEVICE: TX'ed to BB:0A:DC:A5:75
LOGITACKER_PROCESSOR_PAIR_DEVICE: Phase before RX: 3
LOGITACKER_PROCESSOR_PAIR_DEVICE: |
LOGITACKER_PROCESSOR_PAIR_DEVICE: phase before TX: 3
LOGITACKER_PROCESSOR_PAIR_DEVICE: update TX payload called for unknown pairing phase: 3
LOGITACKER_PROCESSOR_PAIR_DEVICE: phase after TX: 3
LOGITACKER_PROCESSOR_PAIR_DEVICE: E1 40 01 DE 00 |.@...
LOGITACKER_PROCESSOR_PAIR_DEVICE: TX'ed to BB:0A:DC:A5:75
LOGITACKER_PROCESSOR_PAIR_DEVICE: Phase before RX: 3
LOGITACKER_PROCESSOR_PAIR_DEVICE: |
LOGITACKER_PROCESSOR_PAIR_DEVICE: phase before TX: 3
LOGITACKER_PROCESSOR_PAIR_DEVICE: update TX payload called for unknown pairing phase: 3
LOGITACKER_PROCESSOR_PAIR_DEVICE: phase after TX: 3
LOGITACKER_PROCESSOR_PAIR_DEVICE: E1 40 01 DE 00 |.@...
LOGITACKER_PROCESSOR_PAIR_DEVICE: TX'ed to BB:0A:DC:A5:75
After executing "pair device run" nothing happens in the muifying pairing process ("Printing follow up reports ..."). I tried this procedure in standard workmode and in g700 workmode and with different OS-setups:
Kali VM with Vmware
Laptop with pure Kali OS
Android and April Dongle connected via OTG
The text was updated successfully, but these errors were encountered:
Hi,
as the title says, pairing a cu0007 dongle flashed with the G700 firmware doesn't work with the April Brother. I didn't know where to put this issue, in the munifying repo or here, so if this is the wrong place please just inform me and I will create the issue in the other repo as well.
LOGITacker Version: 0.2.1
munifying Version: current git status
Log:
After executing "pair device run" nothing happens in the muifying pairing process ("Printing follow up reports ..."). I tried this procedure in standard workmode and in g700 workmode and with different OS-setups:
The text was updated successfully, but these errors were encountered: