Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Fix energy calibration parameters #208

Closed
steinnymir opened this issue Oct 24, 2023 · 4 comments
Closed

Fix energy calibration parameters #208

steinnymir opened this issue Oct 24, 2023 · 4 comments
Assignees

Comments

@steinnymir
Copy link
Member

@rettigl Is is currently possible to fix a parameter in the energy calibration fit function?

At FLASH we would like to use this to fix the time_offset of the tof by measuring the position of the photon peak. Is there a way to fix this parameter and leave the other free in the energy calibration fit procedure?

@rettigl
Copy link
Member

rettigl commented Oct 24, 2023

I think this is not implemented. There is a limit set on this parameter, I think, so adding some keywords and respective code for fixing parameters is certainly a good idea. Maybe also parameters to add starting values, right now they are kind of fixed, I think, or taken from the boundaries of the provided TOF range or so.

@steinnymir
Copy link
Member Author

Ok, I'll try go through this and implement it within the HEXTOF calibration PR

@steinnymir steinnymir self-assigned this Oct 24, 2023
@steinnymir
Copy link
Member Author

Implemented in #169

@steinnymir
Copy link
Member Author

cosed in #169

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment