Notifications
You must be signed in to change notification settings - Fork 57
/
measure.rb
789 lines (668 loc) · 39.8 KB
/
measure.rb
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
# frozen_string_literal: true
# see the URL below for information on how to write OpenStudio measures
# http://nrel.github.io/OpenStudio-user-documentation/reference/measure_writing_guide/
require 'openstudio'
require_relative 'resources/constants'
require_relative '../../resources/hpxml-measures/HPXMLtoOpenStudio/resources/meta_measure'
# start the measure
class ResStockArguments < OpenStudio::Measure::ModelMeasure
# human readable name
def name
# Measure name should be the title case of the class name.
return 'ResStock Arguments'
end
# human readable description
def description
return 'Measure that pre-processes the arguments passed to the BuildResidentialHPXML and BuildResidentialScheduleFile measures.'
end
# human readable description of modeling approach
def modeler_description
return 'Passes in all arguments from the options lookup, processes them, and then registers values to the runner to be used by other measures.'
end
# define the arguments that the user will input
def arguments(model)
measures_dir = File.absolute_path(File.join(File.dirname(__FILE__), '../../resources/hpxml-measures'))
args = OpenStudio::Measure::OSArgumentVector.new
# BuildResidentialHPXML
full_measure_path = File.join(measures_dir, 'BuildResidentialHPXML', 'measure.rb')
measure = get_measure_instance(full_measure_path)
measure.arguments(model).each do |arg|
next if Constants.build_residential_hpxml_excludes.include? arg.name
# Following are arguments with the same name but different options
next if arg.name == 'geometry_unit_cfa'
# Convert optional arguments to string arguments that allow Constants.Auto for defaulting
if !arg.required
case arg.type.valueName.downcase
when 'choice'
choices = arg.choiceValues.map(&:to_s)
choices.unshift(Constants.Auto)
new_arg = OpenStudio::Measure::OSArgument.makeChoiceArgument(arg.name, choices, false)
when 'boolean'
choices = [Constants.Auto, 'true', 'false']
new_arg = OpenStudio::Measure::OSArgument.makeChoiceArgument(arg.name, choices, false)
else
new_arg = OpenStudio::Measure::OSArgument.makeStringArgument(arg.name, false)
end
new_arg.setDisplayName(arg.displayName.to_s)
new_arg.setDescription(arg.description.to_s)
new_arg.setUnits(arg.units.to_s)
args << new_arg
else
args << arg
end
end
# BuildResidentialScheduleFile
full_measure_path = File.join(measures_dir, 'BuildResidentialScheduleFile', 'measure.rb')
measure = get_measure_instance(full_measure_path)
measure.arguments(model).each do |arg|
next if Constants.build_residential_schedule_file_excludes.include? arg.name
args << arg
end
# Additional arguments
arg = OpenStudio::Measure::OSArgument::makeStringArgument('geometry_unit_cfa_bin', true)
arg.setDisplayName('Geometry: Unit Conditioned Floor Area Bin')
arg.setDescription("E.g., '2000-2499'.")
arg.setDefaultValue('2000-2499')
args << arg
# Adds a geometry_unit_cfa argument similar to the BuildResidentialHPXML measure, but as a string with "auto" allowed
arg = OpenStudio::Measure::OSArgument::makeStringArgument('geometry_unit_cfa', true)
arg.setDisplayName('Geometry: Unit Conditioned Floor Area')
arg.setDescription("E.g., '2000' or '#{Constants.Auto}'.")
arg.setUnits('sqft')
arg.setDefaultValue('2000')
args << arg
arg = OpenStudio::Measure::OSArgument.makeStringArgument('vintage', false)
arg.setDisplayName('Building Construction: Vintage')
arg.setDescription('The building vintage, used for informational purposes only.')
args << arg
arg = OpenStudio::Measure::OSArgument.makeDoubleArgument('exterior_finish_r', true)
arg.setDisplayName('Building Construction: Exterior Finish R-Value')
arg.setUnits('h-ft^2-R/Btu')
arg.setDescription('R-value of the exterior finish.')
arg.setDefaultValue(0.6)
args << arg
level_choices = OpenStudio::StringVector.new
level_choices << 'Bottom'
level_choices << 'Middle'
level_choices << 'Top'
arg = OpenStudio::Measure::OSArgument::makeChoiceArgument('geometry_unit_level', level_choices, false)
arg.setDisplayName('Geometry: Unit Level')
arg.setDescription("The level of the unit. This is required for #{HPXML::ResidentialTypeApartment}s.")
args << arg
horizontal_location_choices = OpenStudio::StringVector.new
horizontal_location_choices << 'None'
horizontal_location_choices << 'Left'
horizontal_location_choices << 'Middle'
horizontal_location_choices << 'Right'
arg = OpenStudio::Measure::OSArgument::makeChoiceArgument('geometry_unit_horizontal_location', horizontal_location_choices, false)
arg.setDisplayName('Geometry: Unit Horizontal Location')
arg.setDescription("The horizontal location of the unit when viewing the front of the building. This is required for #{HPXML::ResidentialTypeSFA} and #{HPXML::ResidentialTypeApartment}s.")
args << arg
arg = OpenStudio::Measure::OSArgument::makeIntegerArgument('geometry_num_floors_above_grade', true)
arg.setDisplayName('Geometry: Number of Floors Above Grade')
arg.setUnits('#')
arg.setDescription("The number of floors above grade (in the unit if #{HPXML::ResidentialTypeSFD} or #{HPXML::ResidentialTypeSFA}, and in the building if #{HPXML::ResidentialTypeApartment}). Conditioned attics are included.")
arg.setDefaultValue(2)
args << arg
corridor_position_choices = OpenStudio::StringVector.new
corridor_position_choices << 'Double-Loaded Interior'
corridor_position_choices << 'Double Exterior'
corridor_position_choices << 'Single Exterior (Front)'
corridor_position_choices << 'None'
arg = OpenStudio::Measure::OSArgument::makeChoiceArgument('geometry_corridor_position', corridor_position_choices, true)
arg.setDisplayName('Geometry: Corridor Position')
arg.setDescription("The position of the corridor. Only applies to #{HPXML::ResidentialTypeSFA} and #{HPXML::ResidentialTypeApartment}s. Exterior corridors are shaded, but not enclosed. Interior corridors are enclosed and conditioned.")
arg.setDefaultValue('Inside')
args << arg
arg = OpenStudio::Measure::OSArgument::makeDoubleArgument('geometry_corridor_width', true)
arg.setDisplayName('Geometry: Corridor Width')
arg.setUnits('ft')
arg.setDescription("The width of the corridor. Only applies to #{HPXML::ResidentialTypeApartment}s.")
arg.setDefaultValue(10.0)
args << arg
arg = OpenStudio::Measure::OSArgument::makeDoubleArgument('wall_continuous_exterior_r', false)
arg.setDisplayName('Wall: Continuous Exterior Insulation Nominal R-value')
arg.setUnits('h-ft^2-R/Btu')
arg.setDescription('Nominal R-value for the wall continuous exterior insulation.')
args << arg
arg = OpenStudio::Measure::OSArgument::makeDoubleArgument('ceiling_insulation_r', true)
arg.setDisplayName('Ceiling: Insulation Nominal R-value')
arg.setUnits('h-ft^2-R/Btu')
arg.setDescription('Nominal R-value for the ceiling (attic floor).')
arg.setDefaultValue(0)
args << arg
arg = OpenStudio::Measure::OSArgument::makeDoubleArgument('rim_joist_continuous_exterior_r', true)
arg.setDisplayName('Rim Joist: Continuous Exterior Insulation Nominal R-value')
arg.setUnits('h-ft^2-R/Btu')
arg.setDescription('Nominal R-value for the rim joist continuous exterior insulation. Only applies to basements/crawlspaces.')
arg.setDefaultValue(0)
args << arg
arg = OpenStudio::Measure::OSArgument::makeDoubleArgument('rim_joist_continuous_interior_r', true)
arg.setDisplayName('Rim Joist: Continuous Interior Insulation Nominal R-value')
arg.setUnits('h-ft^2-R/Btu')
arg.setDescription('Nominal R-value for the rim joist continuous interior insulation that runs parallel to floor joists. Only applies to basements/crawlspaces.')
arg.setDefaultValue(0)
args << arg
arg = OpenStudio::Measure::OSArgument::makeDoubleArgument('rim_joist_assembly_interior_r', true)
arg.setDisplayName('Rim Joist: Interior Assembly R-value')
arg.setUnits('h-ft^2-R/Btu')
arg.setDescription('Assembly R-value for the rim joist assembly interior insulation that runs perpendicular to floor joists. Only applies to basements/crawlspaces.')
arg.setDefaultValue(0)
args << arg
arg = OpenStudio::Measure::OSArgument::makeDoubleArgument('air_leakage_percent_reduction', false)
arg.setDisplayName('Air Leakage: Value Reduction')
arg.setDescription('Reduction (%) on the air exchange rate value.')
args << arg
arg = OpenStudio::Measure::OSArgument::makeDoubleArgument('misc_plug_loads_television_2_usage_multiplier', true)
arg.setDisplayName('Plug Loads: Television Usage Multiplier 2')
arg.setDescription('Additional multiplier on the television energy usage that can reflect, e.g., high/low usage occupants.')
arg.setDefaultValue(1.0)
args << arg
arg = OpenStudio::Measure::OSArgument::makeDoubleArgument('misc_plug_loads_other_2_usage_multiplier', true)
arg.setDisplayName('Plug Loads: Other Usage Multiplier 2')
arg.setDescription('Additional multiplier on the other energy usage that can reflect, e.g., high/low usage occupants.')
arg.setDefaultValue(1.0)
args << arg
arg = OpenStudio::Measure::OSArgument::makeDoubleArgument('misc_plug_loads_well_pump_2_usage_multiplier', true)
arg.setDisplayName('Plug Loads: Well Pump Usage Multiplier 2')
arg.setDescription('Additional multiplier on the well pump energy usage that can reflect, e.g., high/low usage occupants.')
arg.setDefaultValue(0.0)
args << arg
arg = OpenStudio::Measure::OSArgument::makeDoubleArgument('misc_plug_loads_vehicle_2_usage_multiplier', true)
arg.setDisplayName('Plug Loads: Vehicle Usage Multiplier 2')
arg.setDescription('Additional multiplier on the electric vehicle energy usage that can reflect, e.g., high/low usage occupants.')
arg.setDefaultValue(0.0)
args << arg
arg = OpenStudio::Measure::OSArgument::makeDoubleArgument('hvac_control_heating_weekday_setpoint_temp', true)
arg.setDisplayName('Heating Setpoint: Weekday Temperature')
arg.setDescription('Specify the weekday heating setpoint temperature.')
arg.setUnits('deg-F')
arg.setDefaultValue(71)
args << arg
arg = OpenStudio::Measure::OSArgument::makeDoubleArgument('hvac_control_heating_weekend_setpoint_temp', true)
arg.setDisplayName('Heating Setpoint: Weekend Temperature')
arg.setDescription('Specify the weekend heating setpoint temperature.')
arg.setUnits('deg-F')
arg.setDefaultValue(71)
args << arg
arg = OpenStudio::Measure::OSArgument::makeDoubleArgument('hvac_control_heating_weekday_setpoint_offset_magnitude', true)
arg.setDisplayName('Heating Setpoint: Weekday Offset Magnitude')
arg.setDescription('Specify the weekday heating offset magnitude.')
arg.setUnits('deg-F')
arg.setDefaultValue(0)
args << arg
arg = OpenStudio::Measure::OSArgument::makeDoubleArgument('hvac_control_heating_weekend_setpoint_offset_magnitude', true)
arg.setDisplayName('Heating Setpoint: Weekend Offset Magnitude')
arg.setDescription('Specify the weekend heating offset magnitude.')
arg.setUnits('deg-F')
arg.setDefaultValue(0)
args << arg
arg = OpenStudio::Measure::OSArgument::makeStringArgument('hvac_control_heating_weekday_setpoint_schedule', true)
arg.setDisplayName('Heating Setpoint: Weekday Schedule')
arg.setDescription('Specify the 24-hour comma-separated weekday heating schedule of 0s and 1s.')
arg.setDefaultValue('0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0')
args << arg
arg = OpenStudio::Measure::OSArgument::makeStringArgument('hvac_control_heating_weekend_setpoint_schedule', true)
arg.setDisplayName('Heating Setpoint: Weekend Schedule')
arg.setDescription('Specify the 24-hour comma-separated weekend heating schedule of 0s and 1s.')
arg.setDefaultValue('0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0')
args << arg
arg = OpenStudio::Measure::OSArgument::makeBoolArgument('use_auto_heating_season', true)
arg.setDisplayName('Use Auto Heating Season')
arg.setDescription('Specifies whether to automatically define the heating season based on the weather file.')
arg.setDefaultValue(false)
args << arg
arg = OpenStudio::Measure::OSArgument::makeDoubleArgument('hvac_control_cooling_weekday_setpoint_temp', true)
arg.setDisplayName('Cooling Setpoint: Weekday Temperature')
arg.setDescription('Specify the weekday cooling setpoint temperature.')
arg.setUnits('deg-F')
arg.setDefaultValue(76)
args << arg
arg = OpenStudio::Measure::OSArgument::makeDoubleArgument('hvac_control_cooling_weekend_setpoint_temp', true)
arg.setDisplayName('Cooling Setpoint: Weekend Temperature')
arg.setDescription('Specify the weekend cooling setpoint temperature.')
arg.setUnits('deg-F')
arg.setDefaultValue(76)
args << arg
arg = OpenStudio::Measure::OSArgument::makeDoubleArgument('hvac_control_cooling_weekday_setpoint_offset_magnitude', true)
arg.setDisplayName('Cooling Setpoint: Weekday Offset Magnitude')
arg.setDescription('Specify the weekday cooling offset magnitude.')
arg.setUnits('deg-F')
arg.setDefaultValue(0)
args << arg
arg = OpenStudio::Measure::OSArgument::makeDoubleArgument('hvac_control_cooling_weekend_setpoint_offset_magnitude', true)
arg.setDisplayName('Cooling Setpoint: Weekend Offset Magnitude')
arg.setDescription('Specify the weekend cooling offset magnitude.')
arg.setUnits('deg-F')
arg.setDefaultValue(0)
args << arg
arg = OpenStudio::Measure::OSArgument::makeStringArgument('hvac_control_cooling_weekday_setpoint_schedule', true)
arg.setDisplayName('Cooling Setpoint: Weekday Schedule')
arg.setDescription('Specify the 24-hour comma-separated weekday cooling schedule of 0s and 1s.')
arg.setDefaultValue('0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0')
args << arg
arg = OpenStudio::Measure::OSArgument::makeStringArgument('hvac_control_cooling_weekend_setpoint_schedule', true)
arg.setDisplayName('Cooling Setpoint: Weekend Schedule')
arg.setDescription('Specify the 24-hour comma-separated weekend cooling schedule of 0s and 1s.')
arg.setDefaultValue('0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0')
args << arg
arg = OpenStudio::Measure::OSArgument::makeBoolArgument('use_auto_cooling_season', true)
arg.setDisplayName('Use Auto Cooling Season')
arg.setDescription('Specifies whether to automatically define the cooling season based on the weather file.')
arg.setDefaultValue(false)
args << arg
arg = OpenStudio::Measure::OSArgument::makeStringArgument('heating_system_has_flue_or_chimney', true)
arg.setDisplayName('Heating System: Has Flue or Chimney')
arg.setDescription('Whether the heating system has a flue or chimney.')
arg.setDefaultValue(Constants.Auto)
args << arg
arg = OpenStudio::Measure::OSArgument::makeStringArgument('heating_system_2_has_flue_or_chimney', true)
arg.setDisplayName('Heating System 2: Has Flue or Chimney')
arg.setDescription('Whether the second heating system has a flue or chimney.')
arg.setDefaultValue(Constants.Auto)
args << arg
arg = OpenStudio::Measure::OSArgument::makeStringArgument('water_heater_has_flue_or_chimney', true)
arg.setDisplayName('Water Heater: Has Flue or Chimney')
arg.setDescription('Whether the water heater has a flue or chimney.')
arg.setDefaultValue(Constants.Auto)
args << arg
arg = OpenStudio::Measure::OSArgument::makeDoubleArgument('heating_system_rated_cfm_per_ton', false)
arg.setDisplayName('Heating System: Rated CFM Per Ton')
arg.setDescription('The rated cfm per ton of the heating system.')
arg.setUnits('cfm/ton')
args << arg
arg = OpenStudio::Measure::OSArgument::makeDoubleArgument('heating_system_actual_cfm_per_ton', false)
arg.setDisplayName('Heating System: Actual CFM Per Ton')
arg.setDescription('The actual cfm per ton of the heating system.')
arg.setUnits('cfm/ton')
args << arg
arg = OpenStudio::Measure::OSArgument::makeDoubleArgument('cooling_system_rated_cfm_per_ton', false)
arg.setDisplayName('Cooling System: Rated CFM Per Ton')
arg.setDescription('The rated cfm per ton of the cooling system.')
arg.setUnits('cfm/ton')
args << arg
arg = OpenStudio::Measure::OSArgument::makeDoubleArgument('cooling_system_actual_cfm_per_ton', false)
arg.setDisplayName('Cooling System: Actual CFM Per Ton')
arg.setDescription('The actual cfm per ton of the cooling system.')
arg.setUnits('cfm/ton')
args << arg
arg = OpenStudio::Measure::OSArgument::makeDoubleArgument('cooling_system_frac_manufacturer_charge', false)
arg.setDisplayName('Cooling System: Fraction of Manufacturer Recommended Charge')
arg.setDescription('The fraction of manufacturer recommended charge of the cooling system.')
arg.setUnits('Frac')
args << arg
arg = OpenStudio::Measure::OSArgument::makeDoubleArgument('heat_pump_rated_cfm_per_ton', false)
arg.setDisplayName('Heat Pump: Rated CFM Per Ton')
arg.setDescription('The rated cfm per ton of the heat pump.')
arg.setUnits('cfm/ton')
args << arg
arg = OpenStudio::Measure::OSArgument::makeDoubleArgument('heat_pump_actual_cfm_per_ton', false)
arg.setDisplayName('Heat Pump: Actual CFM Per Ton')
arg.setDescription('The actual cfm per ton of the heat pump.')
arg.setUnits('cfm/ton')
args << arg
arg = OpenStudio::Measure::OSArgument::makeDoubleArgument('heat_pump_frac_manufacturer_charge', false)
arg.setDisplayName('Heat Pump: Fraction of Manufacturer Recommended Charge')
arg.setDescription('The fraction of manufacturer recommended charge of the heat pump.')
arg.setUnits('Frac')
args << arg
arg = OpenStudio::Measure::OSArgument::makeBoolArgument('heat_pump_backup_use_existing_system', false)
arg.setDisplayName('Heat Pump: Backup Use Existing System')
arg.setDescription('Whether the heat pump uses the existing system as backup.')
args << arg
return args
end
# define what happens when the measure is run
def run(model, runner, user_arguments)
super(model, runner, user_arguments)
# use the built-in error checking
if !runner.validateUserArguments(arguments(model), user_arguments)
return false
end
# assign the user inputs to variables
args = runner.getArgumentValues(arguments(model), user_arguments)
measures_dir = File.absolute_path(File.join(File.dirname(__FILE__), '../../resources/hpxml-measures'))
arg_names = []
{ 'BuildResidentialHPXML' => Constants.build_residential_hpxml_excludes,
'BuildResidentialScheduleFile' => Constants.build_residential_schedule_file_excludes }.each do |measure_name, measure_excludes|
full_measure_path = File.join(measures_dir, measure_name, 'measure.rb')
measure = get_measure_instance(full_measure_path)
measure.arguments(model).each do |arg|
next if measure_excludes.include? arg.name
arg_names << arg.name.to_sym
end
end
args_to_delete = args.keys - arg_names # these are the extra ones added in the arguments section
# Conditioned floor area
if args[:geometry_unit_cfa] == Constants.Auto
cfas = { ['0-499', HPXML::ResidentialTypeSFD] => 298, # AHS 2021, 1 detached and mobile home weighted average
['0-499', HPXML::ResidentialTypeSFA] => 273, # AHS 2021, 1 detached and mobile home weighted average
['0-499', HPXML::ResidentialTypeApartment] => 322, # AHS 2021, multi-family weighted average
['500-749', HPXML::ResidentialTypeSFD] => 634, # AHS 2021, 1 detached and mobile home weighted average
['500-749', HPXML::ResidentialTypeSFA] => 625, # AHS 2021, 1 attached
['500-749', HPXML::ResidentialTypeApartment] => 623, # AHS 2021, multi-family weighted average
['750-999', HPXML::ResidentialTypeSFD] => 881, # AHS 2021, 1 detached and mobile home weighted average
['750-999', HPXML::ResidentialTypeSFA] => 872, # AHS 2021, 1 attached
['750-999', HPXML::ResidentialTypeApartment] => 854, # AHS 2021, multi-family weighted average
['1000-1499', HPXML::ResidentialTypeSFD] => 1228, # AHS 2021, 1 detached and mobile home weighted average
['1000-1499', HPXML::ResidentialTypeSFA] => 1207, # AHS 2021, 1 attached
['1000-1499', HPXML::ResidentialTypeApartment] => 1138, # AHS 2021, multi-family weighted average
['1500-1999', HPXML::ResidentialTypeSFD] => 1698, # AHS 2021, 1 detached and mobile home weighted average
['1500-1999', HPXML::ResidentialTypeSFA] => 1678, # AHS 2021, 1 attached
['1500-1999', HPXML::ResidentialTypeApartment] => 1682, # AHS 2021, multi-family weighted average
['2000-2499', HPXML::ResidentialTypeSFD] => 2179, # AHS 2021, 1 detached and mobile home weighted average
['2000-2499', HPXML::ResidentialTypeSFA] => 2152, # AHS 2021, 1 attached
['2000-2499', HPXML::ResidentialTypeApartment] => 2115, # AHS 2021, multi-family weighted average
['2500-2999', HPXML::ResidentialTypeSFD] => 2678, # AHS 2021, 1 detached and mobile home weighted average
['2500-2999', HPXML::ResidentialTypeSFA] => 2663, # AHS 2021, 1 attached
['2500-2999', HPXML::ResidentialTypeApartment] => 2648, # AHS 2021, multi-family weighted average
['3000-3999', HPXML::ResidentialTypeSFD] => 3310, # AHS 2021, 1 detached and mobile home weighted average
['3000-3999', HPXML::ResidentialTypeSFA] => 3228, # AHS 2021, 1 attached
['3000-3999', HPXML::ResidentialTypeApartment] => 3171, # AHS 2021, multi-family weighted average
['4000+', HPXML::ResidentialTypeSFD] => 5587, # AHS 2021, 1 detached and mobile home weighted average
['4000+', HPXML::ResidentialTypeSFA] => 7414, # AHS 2019, 1 attached
['4000+', HPXML::ResidentialTypeApartment] => 6348 } # AHS 2021, 4,000 or more all unit average
cfa = cfas[[args[:geometry_unit_cfa_bin], args[:geometry_unit_type]]]
if cfa.nil?
runner.registerError("ResStockArguments: Could not look up conditioned floor area for '#{args[:geometry_unit_cfa_bin]}' and '#{args[:geometry_unit_type]}'.")
return false
end
args[:geometry_unit_cfa] = Float(cfa)
else
args[:geometry_unit_cfa] = Float(args[:geometry_unit_cfa])
end
# Vintage
if !args[:vintage].nil? && args[:year_built].to_s == Constants.Auto
args[:year_built] = Integer(Float(args[:vintage].gsub(/[^0-9]/, ''))) # strip non-numeric
end
# Num Occupants
if args[:geometry_unit_num_occupants].to_s == Constants.Auto
args[:geometry_unit_num_occupants] = Geometry.get_occupancy_default_num(args[:geometry_unit_num_bedrooms])
else
args[:geometry_unit_num_occupants] = Integer(args[:geometry_unit_num_occupants].to_s)
end
# Plug Loads
args[:misc_plug_loads_television_usage_multiplier] = Float(args[:misc_plug_loads_television_usage_multiplier].to_s) * args[:misc_plug_loads_television_2_usage_multiplier]
args[:misc_plug_loads_other_usage_multiplier] = Float(args[:misc_plug_loads_other_usage_multiplier].to_s) * args[:misc_plug_loads_other_2_usage_multiplier]
args[:misc_plug_loads_well_pump_usage_multiplier] = Float(args[:misc_plug_loads_well_pump_usage_multiplier].to_s) * args[:misc_plug_loads_well_pump_2_usage_multiplier]
args[:misc_plug_loads_vehicle_usage_multiplier] = Float(args[:misc_plug_loads_vehicle_usage_multiplier].to_s) * args[:misc_plug_loads_vehicle_2_usage_multiplier]
# Other
if args[:misc_plug_loads_other_annual_kwh].to_s == Constants.Auto
if [HPXML::ResidentialTypeSFD].include?(args[:geometry_unit_type])
args[:misc_plug_loads_other_annual_kwh] = 863.26 + 219.26 * args[:geometry_unit_num_occupants] + 0.33 * args[:geometry_unit_cfa] # RECS 2020
elsif [HPXML::ResidentialTypeSFA].include?(args[:geometry_unit_type])
args[:misc_plug_loads_other_annual_kwh] = 654.92 + 206.52 * args[:geometry_unit_num_occupants] + 0.21 * args[:geometry_unit_cfa] # RECS 2020
elsif [HPXML::ResidentialTypeApartment].include?(args[:geometry_unit_type])
args[:misc_plug_loads_other_annual_kwh] = 706.6 + 149.27 * args[:geometry_unit_num_occupants] + 0.1 * args[:geometry_unit_cfa] # RECS 2020
end
end
# PV
if args[:pv_system_present] == 'true'
args[:pv_system_num_bedrooms_served] = Integer(args[:geometry_unit_num_bedrooms])
else
args[:pv_system_num_bedrooms_served] = 0
end
# Battery
if args[:battery_present] == 'true'
args[:battery_num_bedrooms_served] = Integer(args[:geometry_unit_num_bedrooms])
else
args[:battery_num_bedrooms_served] = 0
end
# Setpoints
weekday_heating_setpoints = [args[:hvac_control_heating_weekday_setpoint_temp]] * 24
weekend_heating_setpoints = [args[:hvac_control_heating_weekend_setpoint_temp]] * 24
weekday_cooling_setpoints = [args[:hvac_control_cooling_weekday_setpoint_temp]] * 24
weekend_cooling_setpoints = [args[:hvac_control_cooling_weekend_setpoint_temp]] * 24
hvac_control_heating_weekday_setpoint_offset_magnitude = args[:hvac_control_heating_weekday_setpoint_offset_magnitude]
hvac_control_heating_weekday_setpoint_schedule = args[:hvac_control_heating_weekday_setpoint_schedule].split(',').map { |i| Float(i) }
weekday_heating_setpoints = modify_setpoint_schedule(weekday_heating_setpoints, hvac_control_heating_weekday_setpoint_offset_magnitude, hvac_control_heating_weekday_setpoint_schedule)
hvac_control_heating_weekend_setpoint_offset_magnitude = args[:hvac_control_heating_weekend_setpoint_offset_magnitude]
hvac_control_heating_weekend_setpoint_schedule = args[:hvac_control_heating_weekend_setpoint_schedule].split(',').map { |i| Float(i) }
weekend_heating_setpoints = modify_setpoint_schedule(weekend_heating_setpoints, hvac_control_heating_weekend_setpoint_offset_magnitude, hvac_control_heating_weekend_setpoint_schedule)
hvac_control_cooling_weekday_setpoint_offset_magnitude = args[:hvac_control_cooling_weekday_setpoint_offset_magnitude]
hvac_control_cooling_weekday_setpoint_schedule = args[:hvac_control_cooling_weekday_setpoint_schedule].split(',').map { |i| Float(i) }
weekday_cooling_setpoints = modify_setpoint_schedule(weekday_cooling_setpoints, hvac_control_cooling_weekday_setpoint_offset_magnitude, hvac_control_cooling_weekday_setpoint_schedule)
hvac_control_cooling_weekend_setpoint_offset_magnitude = args[:hvac_control_cooling_weekend_setpoint_offset_magnitude]
hvac_control_cooling_weekend_setpoint_schedule = args[:hvac_control_cooling_weekend_setpoint_schedule].split(',').map { |i| Float(i) }
weekend_cooling_setpoints = modify_setpoint_schedule(weekend_cooling_setpoints, hvac_control_cooling_weekend_setpoint_offset_magnitude, hvac_control_cooling_weekend_setpoint_schedule)
args[:hvac_control_heating_weekday_setpoint] = weekday_heating_setpoints.join(', ')
args[:hvac_control_heating_weekend_setpoint] = weekend_heating_setpoints.join(', ')
args[:hvac_control_cooling_weekday_setpoint] = weekday_cooling_setpoints.join(', ')
args[:hvac_control_cooling_weekend_setpoint] = weekend_cooling_setpoints.join(', ')
# Seasons
if args[:use_auto_heating_season] && args[:hvac_control_heating_season_period].to_s == Constants.Auto
args[:hvac_control_heating_season_period] = HPXML::BuildingAmerica
end
if args[:use_auto_cooling_season] && args[:hvac_control_cooling_season_period].to_s == Constants.Auto
args[:hvac_control_cooling_season_period] = HPXML::BuildingAmerica
end
# Flue or Chimney
if (args[:heating_system_has_flue_or_chimney] == 'false') &&
(args[:heating_system_2_has_flue_or_chimney] == 'false') &&
(args[:water_heater_has_flue_or_chimney] == 'false')
args[:air_leakage_has_flue_or_chimney_in_conditioned_space] = false
elsif (args[:heating_system_type] != 'none' && args[:heating_system_has_flue_or_chimney] == 'true') ||
(args[:heating_system_2_type] != 'none' && args[:heating_system_2_has_flue_or_chimney] == 'true') ||
(args[:water_heater_type] != 'none' && args[:water_heater_has_flue_or_chimney] == 'true')
args[:air_leakage_has_flue_or_chimney_in_conditioned_space] = true
end
# HVAC Secondary
if args[:heating_system_2_type] != 'none'
if args[:heating_system_type] != 'none'
if ((args[:heating_system_fraction_heat_load_served] + args[:heating_system_2_fraction_heat_load_served]) > 1.0)
info_msg = "Adjusted fraction of heat load served by the primary heating system (#{args[:heating_system_fraction_heat_load_served]}"
args[:heating_system_fraction_heat_load_served] = 1.0 - args[:heating_system_2_fraction_heat_load_served]
info_msg += " to #{args[:heating_system_fraction_heat_load_served]}) to allow for a secondary heating system (#{args[:heating_system_2_fraction_heat_load_served]})."
runner.registerInfo(info_msg)
end
elsif args[:heat_pump_type] != 'none'
if ((args[:heat_pump_fraction_heat_load_served] + args[:heating_system_2_fraction_heat_load_served]) > 1.0)
info_msg = "Adjusted fraction of heat load served by the primary heating system (#{args[:heat_pump_fraction_heat_load_served]}"
args[:heat_pump_fraction_heat_load_served] = 1.0 - args[:heating_system_2_fraction_heat_load_served]
info_msg += " to #{args[:heat_pump_fraction_heat_load_served]}) to allow for a secondary heating system (#{args[:heating_system_2_fraction_heat_load_served]})."
runner.registerInfo(info_msg)
end
end
end
# HVAC Faults
if !args[:heating_system_rated_cfm_per_ton].nil? && !args[:heating_system_actual_cfm_per_ton].nil?
args[:heating_system_airflow_defect_ratio] = (args[:heating_system_actual_cfm_per_ton] - args[:heating_system_rated_cfm_per_ton]) / args[:heating_system_rated_cfm_per_ton]
end
if !args[:cooling_system_rated_cfm_per_ton].nil? && !args[:cooling_system_actual_cfm_per_ton].nil?
args[:cooling_system_airflow_defect_ratio] = (args[:cooling_system_actual_cfm_per_ton] - args[:cooling_system_rated_cfm_per_ton]) / args[:cooling_system_rated_cfm_per_ton]
end
if !args[:cooling_system_frac_manufacturer_charge].nil?
args[:cooling_system_charge_defect_ratio] = args[:cooling_system_frac_manufacturer_charge] - 1.0
end
if !args[:heat_pump_rated_cfm_per_ton].nil? && !args[:heat_pump_actual_cfm_per_ton].nil?
args[:heat_pump_airflow_defect_ratio] = (args[:heat_pump_actual_cfm_per_ton] - args[:heat_pump_rated_cfm_per_ton]) / args[:heat_pump_rated_cfm_per_ton]
end
if !args[:heat_pump_frac_manufacturer_charge].nil?
args[:heat_pump_charge_defect_ratio] = args[:heat_pump_frac_manufacturer_charge] - 1.0
end
# Error check geometry inputs
corridor_width = args[:geometry_corridor_width]
corridor_position = args[:geometry_corridor_position].to_s
if (corridor_width == 0) && (corridor_position != 'None')
corridor_position = 'None'
end
if corridor_position == 'None'
corridor_width = 0
end
if corridor_width < 0
runner.registerError('ResStockArguments: Invalid corridor width entered.')
return false
end
# Adiabatic Walls
args[:geometry_unit_left_wall_is_adiabatic] = false
args[:geometry_unit_right_wall_is_adiabatic] = false
args[:geometry_unit_front_wall_is_adiabatic] = false
args[:geometry_unit_back_wall_is_adiabatic] = false
# Map corridor arguments to adiabatic walls and shading
n_floors = Float(args[:geometry_num_floors_above_grade].to_s)
if [HPXML::ResidentialTypeApartment, HPXML::ResidentialTypeSFA].include? args[:geometry_unit_type]
n_units = Float(args[:geometry_building_num_units].to_s)
horiz_location = args[:geometry_unit_horizontal_location].to_s
aspect_ratio = Float(args[:geometry_unit_aspect_ratio].to_s)
if args[:geometry_unit_type] == HPXML::ResidentialTypeApartment
n_units_per_floor = n_units / n_floors
if n_units_per_floor >= 4 && (corridor_position == 'Double Exterior' || corridor_position == 'None')
has_rear_units = true
args[:geometry_unit_back_wall_is_adiabatic] = true
elsif n_units_per_floor >= 4 && (corridor_position == 'Double-Loaded Interior')
has_rear_units = true
args[:geometry_unit_front_wall_is_adiabatic] = true
elsif (n_units_per_floor == 2) && (horiz_location == 'None') && (corridor_position == 'Double Exterior' || corridor_position == 'None')
has_rear_units = true
args[:geometry_unit_back_wall_is_adiabatic] = true
elsif (n_units_per_floor == 2) && (horiz_location == 'None') && (corridor_position == 'Double-Loaded Interior')
has_rear_units = true
args[:geometry_unit_front_wall_is_adiabatic] = true
elsif corridor_position == 'Single Exterior (Front)'
has_rear_units = false
args[:geometry_unit_front_wall_is_adiabatic] = false
else
has_rear_units = false
args[:geometry_unit_front_wall_is_adiabatic] = false
end
# Error check MF & SFA geometry
if !has_rear_units && ((corridor_position == 'Double-Loaded Interior') || (corridor_position == 'Double Exterior'))
corridor_position = 'Single Exterior (Front)'
runner.registerWarning("Specified incompatible corridor; setting corridor position to '#{corridor_position}'.")
end
# Model exterior corridors as overhangs
if (corridor_position.include? 'Exterior') && corridor_width > 0
args[:overhangs_front_depth] = corridor_width
args[:overhangs_front_distance_to_top_of_window] = 1
end
elsif args[:geometry_unit_type] == HPXML::ResidentialTypeSFA
n_floors = 1.0
n_units_per_floor = n_units
has_rear_units = false
end
if has_rear_units
unit_width = n_units_per_floor / 2
else
unit_width = n_units_per_floor
end
if (unit_width <= 1) && (horiz_location != 'None')
runner.registerWarning("No #{horiz_location} location exists, setting horizontal location to 'None'")
horiz_location = 'None'
end
if (unit_width > 1) && (horiz_location == 'None')
runner.registerError('ResStockArguments: Specified incompatible horizontal location for the corridor and unit configuration.')
return false
end
if (unit_width <= 2) && (horiz_location == 'Middle')
runner.registerError('ResStockArguments: Invalid horizontal location entered, no middle location exists.')
return false
end
# Infiltration adjustment for SFA/MF units
# Calculate exposed wall area ratio for the unit (unit exposed wall area
# divided by average unit exposed wall area)
if (n_units_per_floor <= 2) || (n_units_per_floor == 4 && has_rear_units) # No middle unit(s)
exposed_wall_area_ratio = 1.0 # all units have same exterior wall area
else # Has middle unit(s)
if has_rear_units
n_end_units = 4 * n_floors
n_mid_units = n_units - n_end_units
n_bldg_fronts_backs = n_end_units + n_mid_units
n_bldg_sides = n_end_units
else
n_end_units = 2 * n_floors
n_mid_units = n_units - n_end_units
n_bldg_fronts_backs = n_end_units * 2 + n_mid_units * 2
n_bldg_sides = n_end_units
end
if has_rear_units
n_unit_fronts_backs = 1
else
n_unit_fronts_backs = 2
end
if ['Middle'].include? horiz_location
n_unit_sides = 0
elsif ['Left', 'Right'].include? horiz_location
n_unit_sides = 1
end
n_bldg_sides_equivalent = n_bldg_sides + n_bldg_fronts_backs * aspect_ratio
n_unit_sides_equivalent = n_unit_sides + n_unit_fronts_backs * aspect_ratio
exposed_wall_area_ratio = n_unit_sides_equivalent / (n_bldg_sides_equivalent / n_units)
end
# Apply adjustment to infiltration value
args[:air_leakage_value] *= exposed_wall_area_ratio
if horiz_location == 'Left'
args[:geometry_unit_right_wall_is_adiabatic] = true
elsif horiz_location == 'Middle'
args[:geometry_unit_left_wall_is_adiabatic] = true
args[:geometry_unit_right_wall_is_adiabatic] = true
elsif horiz_location == 'Right'
args[:geometry_unit_left_wall_is_adiabatic] = true
end
end
# Infiltration Reduction
if not args[:air_leakage_percent_reduction].nil?
args[:air_leakage_value] *= (1.0 - args[:air_leakage_percent_reduction] / 100.0)
end
# Num Floors
if args[:geometry_unit_type] == HPXML::ResidentialTypeApartment
args[:geometry_unit_num_floors_above_grade] = 1
else
args[:geometry_unit_num_floors_above_grade] = Integer(args[:geometry_num_floors_above_grade])
end
# Adiabatic Floor/Ceiling
if not args[:geometry_unit_level].nil?
if args[:geometry_unit_level] == 'Bottom'
if args[:geometry_num_floors_above_grade] > 1 # this could be "bottom" of a 1-story building
args[:geometry_attic_type] = HPXML::AtticTypeBelowApartment
end
elsif args[:geometry_unit_level] == 'Middle'
args[:geometry_foundation_type] = HPXML::FoundationTypeAboveApartment
args[:geometry_attic_type] = HPXML::AtticTypeBelowApartment
elsif args[:geometry_unit_level] == 'Top'
args[:geometry_foundation_type] = HPXML::FoundationTypeAboveApartment
end
end
# Wall Assembly R-Value
args[:wall_assembly_r] += args[:exterior_finish_r]
if not args[:wall_continuous_exterior_r].nil?
args[:wall_assembly_r] += args[:wall_continuous_exterior_r]
end
# Rim Joist Assembly R-Value
rim_joist_assembly_r = 0
if Float(args[:geometry_rim_joist_height].to_s) > 0
drywall_assembly_r = 0.9
uninsulated_wall_assembly_r = 3.4
assembly_exterior_r = args[:exterior_finish_r] + args[:rim_joist_continuous_exterior_r]
if args[:rim_joist_continuous_interior_r] > 0 && args[:rim_joist_assembly_interior_r] > 0
# rim joist assembly = siding + half continuous interior insulation + half rim joist assembly - drywall
# (rim joist assembly = nominal cavity + 1/2 in sheathing + 1/2 in drywall)
assembly_interior_r = (args[:rim_joist_continuous_interior_r] + uninsulated_wall_assembly_r - drywall_assembly_r) / 2.0 # parallel to floor joists
assembly_interior_r += (args[:rim_joist_assembly_interior_r]) / 2.0 # derated
elsif args[:rim_joist_continuous_interior_r] > 0 || args[:rim_joist_assembly_interior_r] > 0
runner.registerError('ResStockArguments: For rim joist interior insulation, must provide both continuous and assembly R-values.')
return false
else # uninsulated interior
# rim joist assembly = siding + continuous foundation insulation + uninsulated wall - drywall
# (uninsulated wall is nominal cavity + 1/2 in sheathing + 1/2 in drywall)
assembly_interior_r = uninsulated_wall_assembly_r - drywall_assembly_r
end
rim_joist_assembly_r = assembly_exterior_r + assembly_interior_r
end
args[:rim_joist_assembly_r] = rim_joist_assembly_r
args.each do |arg_name, arg_value|
if args_to_delete.include?(arg_name) || (arg_value == Constants.Auto)
arg_value = '' # don't assign these to BuildResidentialHPXML or BuildResidentialScheduleFile
end
register_value(runner, arg_name.to_s, arg_value)
end
return true
end
def modify_setpoint_schedule(schedule, offset_magnitude, offset_schedule)
offset_schedule.each_with_index do |direction, i|
schedule[i] += offset_magnitude * direction
end
return schedule
end
end
# register the measure to be used by the application
ResStockArguments.new.registerWithApplication