Notifications
You must be signed in to change notification settings - Fork 20
/
Copy paththermosyphon.jl
182 lines (171 loc) · 9.85 KB
/
thermosyphon.jl
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
# *********************************************************************************
# REopt, Copyright (c) 2019-2020, Alliance for Sustainable Energy, LLC.
# All rights reserved.
#
# Redistribution and use in source and binary forms, with or without modification,
# are permitted provided that the following conditions are met:
#
# Redistributions of source code must retain the above copyright notice, this list
# of conditions and the following disclaimer.
#
# Redistributions in binary form must reproduce the above copyright notice, this
# list of conditions and the following disclaimer in the documentation and/or other
# materials provided with the distribution.
#
# Neither the name of the copyright holder nor the names of its contributors may be
# used to endorse or promote products derived from this software without specific
# prior written permission.
#
# THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND
# ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED
# WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED.
# IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT,
# INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING,
# BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
# DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF
# LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE
# OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED
# OF THE POSSIBILITY OF SUCH DAMAGE.
# *********************************************************************************
"""
Thermosyphon
struct with inner constructor:
```julia
function Thermosyphon(;
ambient_temp_degF::Array{<:Real,1} = Real[],
ground_temp_degF::Real=25,
passive_to_active_cutoff_temp_degF::Real=20,
effective_conductance_btu_per_degF::Real=141,
fixed_active_cooling_rate_kw::Real=0.345, # average cooling rate from most recent data, was 0.197 kw
COP_curve_points_ambient_temp_degF::Array{<:Real,1} = Real[], #ordered from lowest to highest temperature
COP_curve_points_COP_kw_per_kw::Union{Real,Array{<:Real,1}} = Real[], #one-to-one with COP_curve_points_ambient_temp_degF
structure_heat_to_ground_mmbtu_per_year::Real=5.9,
latitude::Float64,
longitude::Float64
design_active_cooling_rate_btu_per_hour::Real=0.197, #TODO: change # to from kw to btu/hour
)
```
"""
struct Thermosyphon <: AbstractTech
min_annual_active_cooling_mmbtu
min_monthly_active_cooling_mmbtu
coefficient_of_performance_series_mmbtu_per_kwh
active_cooling_rate_mmbtu_per_hour
time_steps_can_actively_cool
time_steps_passively_cooling
function Thermosyphon(;
ambient_temp_degF::Array{<:Real,1} = Real[],
ground_temp_degF::Real=25,
passive_to_active_cutoff_temp_degF::Real=20,
effective_conductance_btu_per_degF::Real=141,
fixed_active_cooling_rate_kw::Real=0.345, # average cooling rate from most recent data, was 0.197 kw
COP_curve_points_ambient_temp_degF::Array{<:Real,1} = Real[], #ordered from lowest to highest temperature
COP_curve_points_COP_kw_per_kw::Union{Real,Array{<:Real,1}} = Real[], #one-to-one with COP_curve_points_ambient_temp_degF
structure_heat_to_ground_mmbtu_per_year::Real=5.9,
latitude::Float64,
longitude::Float64
)
# validate inputs
invalid_args = String[]
if !isempty(ambient_temp_degF) && length(ambient_temp_degF) != 8760
push!(invalid_args, "if ambient_temp_degF is provided it's length must be 8760, got length of $(length(ambient_temp_degF))")
end
if !(0 <= effective_conductance_btu_per_degF)
push!(invalid_args, "effective_conductance_btu_per_degF must satisfy 0 <= effective_conductance_btu_per_degF, got $(effective_conductance_btu_per_degF)")
end
if !(0 <= fixed_active_cooling_rate_kw)
push!(invalid_args, "design_active_cooling_rate_kw must satisfy 0 <= design_active_cooling_rate_kw, got $(design_active_cooling_rate_kw)")
end
if !(0 <= structure_heat_to_ground_mmbtu_per_year)
push!(invalid_args, "structure_heat_to_ground_mmbtu_per_year must satisfy 0 <= structure_heat_to_ground_mmbtu_per_year, got $(structure_heat_to_ground_mmbtu_per_year)")
end
if typeof(COP_curve_points_COP_kw_per_kw) <: Real
COP_curve_points_COP_kw_per_kw = [COP_curve_points_COP_kw_per_kw]
if isempty(COP_curve_points_ambient_temp_degF)
COP_curve_points_ambient_temp_degF = Real[0] #does't matter what value is in here because with only one point the COP curve is a flat line
end
end
if length(COP_curve_points_COP_kw_per_kw) != length(COP_curve_points_ambient_temp_degF)
push!(invalid_args, "COP_curve_points_COP_kw_per_kw and COP_curve_points_ambient_temp_degF must be the same length, got $(length(COP_curve_points_COP_kw_per_kw)) and $(length(COP_curve_points_ambient_temp_degF))")
end
if length(invalid_args) > 0
error("Invalid argument values: $(invalid_args)")
end
if isempty(ambient_temp_degF)
# Call PVWatts for hourly dry-bulb outdoor air temperature
ambient_temp_degF = ambient_temp(latitude, longitude)
end
if fixed_active_cooling_rate_kw > 0
# Calculate passive cooling (only for time steps T_amb < cutoff temp)
passive_cooling = ((ground_temp_degF .- filter(t -> t <= passive_to_active_cutoff_temp_degF, ambient_temp_degF)) .* (effective_conductance_btu_per_degF / 1000000))
# Calculate annual cooling requirement
min_annual_active_cooling_mmbtu = max(0,structure_heat_to_ground_mmbtu_per_year - sum(passive_cooling))
# Calculate COP timeseries: could also interpolate linearly outside where we have data
if isempty(COP_curve_points_ambient_temp_degF)
COP_curve_points_ambient_temp_degF = [46,52,63]
COP_curve_points_COP_kw_per_kw = [9,6,3]
end
coefficient_of_performance_series_mmbtu_per_kwh = zeros(length(ambient_temp_degF))
for i in 1:length(coefficient_of_performance_series_mmbtu_per_kwh)
temp = ambient_temp_degF[i] #< 45 ? 45 : ambient_temp_degF[i]
curve_point_temp_is_LTOET = searchsortedfirst(COP_curve_points_ambient_temp_degF, temp)
if curve_point_temp_is_LTOET == 1
coefficient_of_performance_series_mmbtu_per_kwh[i] = COP_curve_points_COP_kw_per_kw[1] / KWH_PER_MMBTU
elseif curve_point_temp_is_LTOET > length(COP_curve_points_ambient_temp_degF)
coefficient_of_performance_series_mmbtu_per_kwh[i] = COP_curve_points_COP_kw_per_kw[curve_point_temp_is_LTOET-1] / KWH_PER_MMBTU
else
coefficient_of_performance_series_mmbtu_per_kwh[i] = (COP_curve_points_COP_kw_per_kw[curve_point_temp_is_LTOET]
- (
(COP_curve_points_ambient_temp_degF[curve_point_temp_is_LTOET] - temp)
* (COP_curve_points_COP_kw_per_kw[curve_point_temp_is_LTOET] - COP_curve_points_COP_kw_per_kw[curve_point_temp_is_LTOET-1])
/ (COP_curve_points_ambient_temp_degF[curve_point_temp_is_LTOET] - COP_curve_points_ambient_temp_degF[curve_point_temp_is_LTOET-1])
)
) / KWH_PER_MMBTU
end
end
coefficient_of_performance_series_mmbtu_per_kwh = round.(coefficient_of_performance_series_mmbtu_per_kwh, digits=8)
# Calculate const active cooling rate:
active_cooling_rate_mmbtu_per_hour = fixed_active_cooling_rate_kw / KWH_PER_MMBTU
# Calculate timesteps where active cooling is and isn't possible:
time_steps_can_actively_cool = findall(>(passive_to_active_cutoff_temp_degF), ambient_temp_degF)
time_steps_passively_cooling = findall(<=(passive_to_active_cutoff_temp_degF), ambient_temp_degF)
else
min_annual_active_cooling_mmbtu = 0
coefficient_of_performance_series_mmbtu_per_kwh = zeros(length(ambient_temp_degF))
active_cooling_rate_mmbtu_per_hour = 0
time_steps_can_actively_cool = Real[]
time_steps_passively_cooling = Real[] #or all time steps?
end
min_monthly_active_cooling_mmbtu = [0,0,0,0,0,0,0,0,0,0,0,0]
new(
min_annual_active_cooling_mmbtu,
min_monthly_active_cooling_mmbtu,
coefficient_of_performance_series_mmbtu_per_kwh,
active_cooling_rate_mmbtu_per_hour,
time_steps_can_actively_cool,
time_steps_passively_cooling
)
end
end
function ambient_temp(latitude::Real, longitude::Real; timeframe="hourly")
url = string("https://developer.nrel.gov/api/pvwatts/v6.json", "?api_key=", nrel_developer_key,
"&lat=", latitude , "&lon=", longitude,
"&tilt=45&system_capacity=1&azimuth=180&module_type=0&array_type=0&losses=0.14&dc_ac_ratio=1.1&gcr=0.4&inv_eff=96&timeframe=", timeframe
)
try
@info "Querying PVWatts for ambient temperature for thermosyphon"
r = HTTP.get(url)
response = JSON.parse(String(r.body))
if r.status != 200
error("Bad response from PVWatts: $(response["errors"])")
end
@info "PVWatts success."
amb_temp_f = get(response["outputs"], "tamb", []) .* 1.8 .+ 32.0
if length(amb_temp_f) != 8760
@error "PVWatts did not return a valid ambient temperature. Got $amb_temp_f"
end
return amb_temp_f
catch e
@error "Error occurred when calling PVWatts: $e"
end
end