The VISA session of the Serial slave is often left open even though shutdown was called.

This is due to the serial daemon performing a VISA read while VISA close is called. The VISA session is held open by the VISA read.

To fix this, VISA close should be called within the Serial Daemon during shutdown.

@rfporter
Copy link
Author

rfporter commented Mar 6, 2020

Capture

@rfporter
Copy link
Author

rfporter commented Mar 6, 2020

Workaround: call VISA close on the serial port 11 seconds after calling shutdown.