From cf6a6caa68a9e37def668d88c69f539d7c1d8fff Mon Sep 17 00:00:00 2001 From: Scott Lahteine Date: Mon, 30 Jan 2023 22:22:42 -0600 Subject: [PATCH] clear wait_for_heatup when current_temp >= ambient_temp --- Marlin/src/module/temperature.cpp | 1 + 1 file changed, 1 insertion(+) diff --git a/Marlin/src/module/temperature.cpp b/Marlin/src/module/temperature.cpp index a64f51ce20989..b5d1a99cfe36a 100644 --- a/Marlin/src/module/temperature.cpp +++ b/Marlin/src/module/temperature.cpp @@ -974,6 +974,7 @@ volatile bool Temperature::raw_temps_ready = false; next_test_ms += 10000UL; } } + wait_for_heatup = false; #if HAS_FAN set_fan_speed(EITHER(MPC_FAN_0_ALL_HOTENDS, MPC_FAN_0_ACTIVE_HOTEND) ? 0 : active_extruder, 0);