Netdata's health watchdog is highly configurable, with support for dynamic thresholds, hysteresis, alarm templates, and more. You can tweak any of the existing alarms based on your infrastructure's topology or specific monitoring needs, or create new entities.
You can use health alarms in conjunction with any of Netdata's collectors (see the supported collector list) to monitor the health of your systems, containers, and applications in real time.
While you can see active alarms both on the local dashboard and Netdata Cloud, all health alarms are configured per node via individual Netdata Agents. If you want to deploy a new alarm across your infrastructure, you must configure each node with the same health configuration files.
All of Netdata's health configuration files are in Netdata's config
directory, inside the health.d/
directory. Navigate to your Netdata config directory and
use edit-config
to make changes to any of these files.
For example, to edit the cpu.conf
health configuration file, run:
sudo ./edit-config health.d/cpu.conf
Each health configuration file contains one or more health entities, which always begin with alarm:
or template:
.
For example, here is the first health entity in health.d/cpu.conf
:
template: 10min_cpu_usage
on: system.cpu
os: linux
hosts: *
lookup: average -10m unaligned of user,system,softirq,irq,guest
units: %
every: 1m
warn: $this > (($status >= $WARNING) ? (75) : (85))
crit: $this > (($status == $CRITICAL) ? (85) : (95))
delay: down 15m multiplier 1.5 max 1h
info: average cpu utilization for the last 10 minutes (excluding iowait, nice and steal)
to: sysadmin
To tune this alarm to trigger warning and critical alarms at a lower CPU utilization, change the warn
and crit
lines
to the values of your choosing. For example:
warn: $this > (($status >= $WARNING) ? (60) : (75))
crit: $this > (($status == $CRITICAL) ? (75) : (85))
Save the file and reload Netdata's health configuration to make your changes live.
Instead of disabling an alarm altogether, or even disabling all alarms, you can silence individual alarms by changing
one line in a given health entity. To silence any single alarm, change the to:
line in its entity to silent
.
to: silent
While tuning existing alarms may work in some cases, you may need to write entirely new health entities based on how your systems, containers, and applications work.
Read Netdata's health reference for a full listing of the format, syntax, and functionality of health entities.
To write a new health entity into a new file, navigate to your Netdata config directory,
then use touch
to create a new file in the health.d/
directory. Use edit-config
to start editing the file.
As an example, let's create a ram-usage.conf
file.
sudo touch health.d/ram-usage.conf
sudo ./edit-config health.d/ram-usage.conf
For example, here is a health entity that triggers a warning alarm when a node's RAM usage rises above 80%, and a critical alarm above 90%:
alarm: ram_usage
on: system.ram
lookup: average -1m percentage of used
units: %
every: 1m
warn: $this > 80
crit: $this > 90
info: The percentage of RAM being used by the system.
Let's look into each of the lines to see how they create a working health entity.
alarm
: The name for your new entity. The name needs to follow these requirements:- Any alphabet letter or number.
- The symbols
.
and_
. - Cannot be
chart name
,dimension name
,family name
, orchart variable names
.
on
: Which chart the entity listens to.lookup
: Which metrics the alarm monitors, the duration of time to monitor, and how to process the metrics into a usable format.average
: Calculate the average of all the metrics collected.-1m
: Use metrics from 1 minute ago until now to calculate that average.percentage
: Clarify that we're calculating a percentage of RAM usage.of used
: Specify which dimension (used
) on thesystem.ram
chart you want to monitor with this entity.
units
: Use percentages rather than absolute units.every
: How often to perform thelookup
calculation to decide whether or not to trigger this alarm.warn
/crit
: The value at which Netdata should trigger a warning or critical alarm. This example uses simple syntax, but most pre-configured health entities use hysteresis to avoid superfluous notifications.info
: A description of the alarm, which will appear in the dashboard and notifications.
In human-readable format:
This health entity, named ram_usage, watches the system.ram chart. It looks up the last 1 minute of metrics from the used dimension and calculates the average of all those metrics in a percentage format, using a % unit. The entity performs this lookup every minute.
If the average RAM usage percentage over the last 1 minute is more than 80%, the entity triggers a warning alarm. If the usage is more than 90%, the entity triggers a critical alarm.
When you finish writing this new health entity, reload Netdata's health configuration to see it live on the local dashboard or Netdata Cloud.
To make any changes to your health configuration live, you must reload Netdata's health monitoring system. To do that
without restarting all of Netdata, run netdatacli reload-health
or killall -USR2 netdata
.
With your health entities configured properly, it's time to enable notifications to get notified whenever a node reaches a warning or critical state.