Modem charge mAh with different configuration #61

Closed
RobTWTG opened this issue May 16, 2024 · 1 comment
Closed

Modem charge mAh with different configuration #61

RobTWTG opened this issue May 16, 2024 · 1 comment

Comments

@RobTWTG
Copy link

RobTWTG commented May 16, 2024

I noticed that when ral_get_lora_rx_consumption_in_ua is called. rx_boosted is always set to false.

Our PCB uses the sx1261 powered with a 1.8V power supply, the implementation to track consumption only uses the table for a 3.3V power supply.

Will there be an implementation in the future to track the power using rx_boosted and 1.8V?

@opeyrard
Copy link

This limitation is confirmed and will be fixed in the next SWL2001 release.