Triton: run IOC on Triton control PC: implementation #3125
Comments
I guess configuring the IOC will be via globals.txt ? |
Setting the instrument will be done via a PV, see comments of #3091 For the triton there are no other configuration options to worry about (it will always connect to the triton on |
This solution is also of interest to the Cryogenics group (as part of a small project) so that they can monitor the systems centrally (not part of the HLM work). |
Re-requested by Cryogenics group, so re-proposing. They say that better remote diagnostics would help them to prevent somewhere around ~1 problem/cycle (where a "problem" has a lost beamtime impact of multiple hours and sometimes days). Things to do in this ticket:
|
After discussion with @John-Holt-Tessella regarding MySQL (instrument) archives specifically:
|
How inportant is archiving the PVS? The central archive server is not critical for instrument operation and is also not on a system that is under our direct control. |
If the central archive server is not related to the ISIS data archive (where all cite-able data from ISIS is archived) and is not something under our direct control in IBEX where/what on earth is it ? |
@Tom-Willemsen do we need to update the |
I think last time this was discussed we said that the I'm happy to change it if I've misremembered though, let me know. Either way, we should document the decision on the wiki... |
I don't remember, either we should have written it down my bad. Do we run the upgrade script over a new config set by default? If not we should add it to base because other wise new configs won't get that change. |
Is master regularly merged into instrument configs? It seems rather counter intuitive to me that master is actually incorrect and you need to run an additional script to correct it. |
Yes, I think the deploy script automatically merges master into the instrument configs every time we deploy (see https://github.com/ISISComputingGroup/ibex_utils/blob/master/installation_and_upgrade/ibex_install_utils/install_tasks.py#L519 ). That might not be the best solution though. |
As a member of the cryogenics team, I would like the Triton IOC to run on the Triton control PC rather than the instrument PC so that I can run diagnostics easily, without depending on which beamline the fridge is on.
Acceptance criteria
Notes