There seem to be no shadow bits für the SG inputs in the protocol. At least i didn't find any changes in the heatpump reply.
Also the SG function is pretty useless for heishamon users. Increasing/decreasing heatcurve or dhw temp shifts can be derived with existing TOPs much better. No need to put any effort on it
Celphor
changed the title
Protocol description for SG is mixup up
Protocol description for SG is mixed up
Nov 17, 2024
Descriptions in the decyption document for byte 71 and 72 are swapped, as well as 73 and 74
Correct is:
71 = SG Setting 1 DHW Capacity
72 = SG Setting 1 Heating Capacity
73 = SG Setting 2 DHW Capacity
74 = SG Setting 2 Heating Capacity
I can confirm SG works according to the manual when external SG switches are applied