You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Describe the bug
Nozzle temperature reads 30C too high.
To Reproduce
Install the Slice Engineering High Temp thermistor and the HT firmware variant. Turn the printer on. The printer shows the bed temperature at 25C (correct ambient temperature) but the nozzle temperature reads 55C, which is 30C too high.
(I contacted Slice Eng and they advised I measure the resistance at the thermistor. Resistance shows as 550kOhms at an ambient temperature of 25C. This should be correct resistance at that temp. Thermistor seems to be operating correctly which suggests issue with the firmware)
Expected behavior
Printer should show nozzle temperature at same ambient temperature as the bed.
The text was updated successfully, but these errors were encountered:
The 450°C Thermistor should not be used with printers that use a RAMBo Mini V1.3a or any older version of this board. Common printers with this board include the Prusa MK2.5s, the Prusa MK2.5, the Prusa MK2s, and the Prusa MK2.
I could not find a reason why though. Maybe Bondtech just should not offer firmware for the combination MK2*+SliceHT.
Please, before you create a new bug report, please make sure you searched in open and closed issues and couldn't find anything that matches.
Mk2.5S
FW390-Build3922-Bondtech-MK25S-RAMBo13a-SliceE_HT-Mosquito
Describe the bug
Nozzle temperature reads 30C too high.
To Reproduce
Install the Slice Engineering High Temp thermistor and the HT firmware variant. Turn the printer on. The printer shows the bed temperature at 25C (correct ambient temperature) but the nozzle temperature reads 55C, which is 30C too high.
(I contacted Slice Eng and they advised I measure the resistance at the thermistor. Resistance shows as 550kOhms at an ambient temperature of 25C. This should be correct resistance at that temp. Thermistor seems to be operating correctly which suggests issue with the firmware)
Expected behavior
Printer should show nozzle temperature at same ambient temperature as the bed.