forked from psvanstrom/esphome-p1reader
-
Notifications
You must be signed in to change notification settings - Fork 32
/
Copy pathp1mini.yaml
350 lines (335 loc) · 9.63 KB
/
p1mini.yaml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
substitutions:
device_name: p1mini
device_password: !secret p1mini_password
device_api_key: !secret p1mini_api_key
esphome:
name: ${device_name}
esp8266:
board: d1_mini
wifi:
ssid: !secret wifi_ssid
password: !secret wifi_password
# Enable fallback hotspot (captive portal) in case wifi connection fails
ap:
ssid: "esp-${device_name}"
password: "${device_password}"
captive_portal:
# Enable logging
logger:
level: INFO # Set to DEBUG if you are having issues!
baud_rate: 0 # disable logging over uart
# Enable Home Assistant API
api:
#password: "${device_password}" ### Deprecated
encryption:
key: "${device_api_key}"
ota:
platform: esphome # Remove this line to run on ESPHome versions earlier than 2024.6.0
password: "${device_password}"
web_server:
port: 80
ota: false
# auth:
# username: admin
# password: "${device_password}"
external_components:
- source: components
switch:
- platform: gpio
id: p1_rts # Not needed if the RTS signal is not connected to a GPIO
pin:
number: D2
- platform: gpio
id: status_led
pin:
number: D4
inverted: true
binary_sensor:
- platform: gpio
id: secondary_p1_rts # Currently not used, but make sure D0 is configured as input in case it is connected.
pin:
number: D0
mode: INPUT_PULLDOWN
inverted: false
uart:
- id: my_uart_1
tx_pin:
number: TX
inverted: true
mode: OUTPUT_OPEN_DRAIN
rx_pin:
number: RX
inverted: true # Set to false if inverting in hardware
mode: INPUT_PULLUP # Set to INPUT if inverting in hardware
baud_rate: 115200
rx_buffer_size: 512 # Probably not needed, but it is good to have some margin.
# - id: my_uart_2
# ...
p1_mini:
- id: p1_mini_1
uart_id: my_uart_1
minimum_period: 2s # Should be 0 (zero) if the RTS signal is not used.
buffer_size: 3072 # Needs to be large enough to hold one entire update from the meter.
secondary_p1: false
on_ready_to_receive:
then:
- switch.turn_on: p1_rts
- switch.turn_on: status_led
on_receiving_update:
then:
on_update_received:
then:
- switch.turn_off: p1_rts
- switch.turn_off: status_led
on_update_processed:
then:
on_communication_error:
then:
- switch.turn_off: p1_rts
- switch.turn_off: status_led
# - id: p1_mini_2
# uart_id: my_uart_2
# ...
text_sensor:
- platform: p1_mini
name: "Meter ID"
icon: "mdi:identifier"
p1_mini_id: p1_mini_1
identifier: "/"
filters:
- substitute: "/ -> "
# - platform: p1_mini
# name: "Date+Time"
# icon: "mdi:calendar-range"
# p1_mini_id: p1_mini_1
# identifier: "0-0:1.0.0("
# filters:
# - substitute: "0-0:1.0.0( -> "
# - substitute: ") -> "
sensor:
- platform: wifi_signal
name: "${device_name} WiFi Signal"
update_interval: 10s
- platform: p1_mini
p1_mini_id: p1_mini_1
obis_code: "1.8.0"
name: "Cumulative Active Import"
icon: "mdi:transmission-tower-export"
unit_of_measurement: kWh
accuracy_decimals: 3
state_class: "total_increasing"
device_class: "energy"
- platform: p1_mini
p1_mini_id: p1_mini_1
obis_code: "2.8.0"
name: "Cumulative Active Export"
icon: "mdi:transmission-tower-import"
unit_of_measurement: kWh
accuracy_decimals: 3
state_class: "total_increasing"
device_class: "energy"
- platform: p1_mini
p1_mini_id: p1_mini_1
obis_code: "3.8.0"
name: "Cumulative Reactive Import"
icon: "mdi:transmission-tower-export"
unit_of_measurement: kvarh
accuracy_decimals: 3
- platform: p1_mini
p1_mini_id: p1_mini_1
obis_code: "4.8.0"
name: "Cumulative Reactive Export"
icon: "mdi:transmission-tower-import"
unit_of_measurement: kvarh
accuracy_decimals: 3
- platform: p1_mini
p1_mini_id: p1_mini_1
obis_code: "1.7.0"
name: "Momentary Active Import"
icon: "mdi:transmission-tower-export"
unit_of_measurement: kW
accuracy_decimals: 3
device_class: "power"
state_class: "measurement"
- platform: p1_mini
p1_mini_id: p1_mini_1
obis_code: "2.7.0"
name: "Momentary Active Export"
icon: "mdi:transmission-tower-import"
unit_of_measurement: kW
accuracy_decimals: 3
device_class: "power"
state_class: "measurement"
- platform: p1_mini
p1_mini_id: p1_mini_1
obis_code: "3.7.0"
name: "Momentary Reactive Import"
icon: "mdi:transmission-tower-export"
unit_of_measurement: kvar
accuracy_decimals: 3
- platform: p1_mini
p1_mini_id: p1_mini_1
obis_code: "4.7.0"
name: "Momentary Reactive Export"
icon: "mdi:transmission-tower-import"
unit_of_measurement: kvar
accuracy_decimals: 3
- platform: p1_mini
p1_mini_id: p1_mini_1
obis_code: "21.7.0"
name: "Momentary Active Import Phase 1"
icon: "mdi:transmission-tower-export"
unit_of_measurement: kW
accuracy_decimals: 3
device_class: "power"
state_class: "measurement"
- platform: p1_mini
p1_mini_id: p1_mini_1
obis_code: "22.7.0"
name: "Momentary Active Export Phase 1"
icon: "mdi:transmission-tower-import"
unit_of_measurement: kW
accuracy_decimals: 3
device_class: "power"
state_class: "measurement"
- platform: p1_mini
p1_mini_id: p1_mini_1
obis_code: "41.7.0"
name: "Momentary Active Import Phase 2"
icon: "mdi:transmission-tower-export"
unit_of_measurement: kW
accuracy_decimals: 3
device_class: "power"
state_class: "measurement"
- platform: p1_mini
p1_mini_id: p1_mini_1
obis_code: "42.7.0"
name: "Momentary Active Export Phase 2"
icon: "mdi:transmission-tower-import"
unit_of_measurement: kW
accuracy_decimals: 3
device_class: "power"
state_class: "measurement"
- platform: p1_mini
p1_mini_id: p1_mini_1
obis_code: "61.7.0"
name: "Momentary Active Import Phase 3"
icon: "mdi:transmission-tower-export"
unit_of_measurement: kW
accuracy_decimals: 3
device_class: "power"
state_class: "measurement"
- platform: p1_mini
p1_mini_id: p1_mini_1
obis_code: "62.7.0"
name: "Momentary Active Export Phase 3"
icon: "mdi:transmission-tower-import"
unit_of_measurement: kW
accuracy_decimals: 3
device_class: "power"
state_class: "measurement"
- platform: p1_mini
p1_mini_id: p1_mini_1
obis_code: "23.7.0"
name: "Momentary Reactive Import Phase 1"
icon: "mdi:transmission-tower-export"
unit_of_measurement: kvar
accuracy_decimals: 3
- platform: p1_mini
p1_mini_id: p1_mini_1
obis_code: "24.7.0"
name: "Momentary Reactive Export Phase 1"
icon: "mdi:transmission-tower-import"
unit_of_measurement: kvar
accuracy_decimals: 3
- platform: p1_mini
p1_mini_id: p1_mini_1
obis_code: "43.7.0"
name: "Momentary Reactive Import Phase 2"
icon: "mdi:transmission-tower-export"
unit_of_measurement: kvar
accuracy_decimals: 3
- platform: p1_mini
p1_mini_id: p1_mini_1
obis_code: "44.7.0"
name: "Momentary Reactive Export Phase 2"
icon: "mdi:transmission-tower-import"
unit_of_measurement: kvar
accuracy_decimals: 3
- platform: p1_mini
p1_mini_id: p1_mini_1
obis_code: "63.7.0"
name: "Momentary Reactive Import Phase 3"
icon: "mdi:transmission-tower-export"
unit_of_measurement: kvar
accuracy_decimals: 3
- platform: p1_mini
p1_mini_id: p1_mini_1
obis_code: "64.7.0"
name: "Momentary Reactive Export Phase 3"
icon: "mdi:transmission-tower-import"
unit_of_measurement: kvar
accuracy_decimals: 3
- platform: p1_mini
p1_mini_id: p1_mini_1
obis_code: "32.7.0"
name: "Voltage Phase 1"
icon: "mdi:lightning-bolt-outline"
unit_of_measurement: V
accuracy_decimals: 1
device_class: "voltage"
state_class: "measurement"
- platform: p1_mini
p1_mini_id: p1_mini_1
obis_code: "52.7.0"
name: "Voltage Phase 2"
icon: "mdi:lightning-bolt-outline"
unit_of_measurement: V
accuracy_decimals: 1
device_class: "voltage"
state_class: "measurement"
- platform: p1_mini
p1_mini_id: p1_mini_1
obis_code: "72.7.0"
name: "Voltage Phase 3"
icon: "mdi:lightning-bolt-outline"
unit_of_measurement: V
accuracy_decimals: 1
device_class: "voltage"
state_class: "measurement"
- platform: p1_mini
p1_mini_id: p1_mini_1
obis_code: "31.7.0"
name: "Current Phase 1"
icon: "mdi:lightning-bolt"
unit_of_measurement: A
accuracy_decimals: 1
device_class: "current"
state_class: "measurement"
- platform: p1_mini
p1_mini_id: p1_mini_1
obis_code: "51.7.0"
name: "Current Phase 2"
icon: "mdi:lightning-bolt"
unit_of_measurement: A
accuracy_decimals: 1
device_class: "current"
state_class: "measurement"
- platform: p1_mini
p1_mini_id: p1_mini_1
obis_code: "71.7.0"
name: "Current Phase 3"
icon: "mdi:lightning-bolt"
unit_of_measurement: A
accuracy_decimals: 1
device_class: "current"
state_class: "measurement"
# - platform: p1_mini
# p1_mini_id: p1_mini_2
# obis_code: "1.8.0"
# name: "Cumulative Active Import, meter 2"
# unit_of_measurement: kWh
# accuracy_decimals: 3
# state_class: "total_increasing"
# device_class: "energy"
# ...